0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RA22101GD152AK6

3RA22101GD152AK6

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    STARTER REV FB S00 4.5-6.3A 120V

  • 数据手册
  • 价格&库存
3RA22101GD152AK6 数据手册
Data sheet 3RA2210-1GD15-2AK6 FUSELESS LOAD FEEDER REVERSING OPERATION, AC 400V, S00 4.5...6.3A, AC 110/120V 50/60HZ SCREW TERMINAL FOR BUSBAR SYSTEMS 60MM TYPE OF ASSIGNMENT 1,IQ = 150KA 1NC (CONTACTOR) product brand name SIRIUS product designation non-fused load feeders 3RA2 design of the product reversing starter manufacturer's article number ● of the supplied contactor 3RT2015-1AK62 ● of the supplied circuit-breakers 3RV2011-1GA10 ● of the supplied RS assembly kit 8US1250-5AS10 ● of the supplied busbar adapter 8US1251-5DS10 ● of the supplied link module 3RA1921-1DA00 General technical data size of the circuit-breaker S00 size of load feeder S00 product extension auxiliary switch Yes insulation voltage with degree of pollution 3 at AC rated value 690 V degree of pollution 3 surge voltage resistance rated value 6 kV shock resistance acc. to IEC 60068-2-27 6g / 11 ms mechanical service life (switching cycles) of contactor typical 30 000 000 type of assignment 1 Substance Prohibitance (Date) 01.10.2009 00:00:00 Ambient conditions ● ambient temperature during operation -20 ... +60 °C ● ambient temperature during storage -50 ... +80 °C ● ambient temperature during transport -50 ... +80 °C Main circuit number of poles for main current circuit 3 design of the switching contact electromechanical adjustable current response value current of the current-dependent overload release 4.5 ... 6.3 A ● operating voltage rated value 690 V ● operating voltage at AC-3 rated value maximum 690 V operating frequency rated value 50 ... 60 Hz operational current at AC-3 at 400 V rated value 4.9 A operating power at AC-3 ● at 400 V rated value 2 200 W ● at 500 V rated value 3 000 W 3RA22101GD152AK6 Page 1/2 1.21.2021 Subject to change without notice © Copyright Siemens ● at 690 V rated value 4 000 W Control circuit/ Control control supply voltage at AC ● at 50 Hz rated value 110 V ● at 60 Hz rated value 120 V apparent holding power of magnet coil at AC 4.2 V·A Protective and monitoring functions trip class CLASS 10 design of the overload release thermal (bimetallic) response value current of instantaneous short-circuit trip unit 81.9 A UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 4.8 A ● at 600 V rated value 6.1 A yielded mechanical performance [hp] ● for single-phase AC motor — at 110/120 V rated value 0.25 hp — at 230 V rated value 0.5 hp ● for 3-phase AC motor — at 200/208 V rated value 1 hp — at 220/230 V rated value 1.5 hp — at 460/480 V rated value 3 hp — at 575/600 V rated value 5 hp Short-circuit protection product function short circuit protection Yes design of the short-circuit trip magnetic conditional short-circuit current (Iq) ● at 690 V acc. to IEC 60947-4-1 rated value 4 000 A ● at 400 V acc. to IEC 60947-4-1 rated value 153 000 A ● at 500 V acc. to IEC 60947-4-1 rated value 100 000 A Installation/ mounting/ dimensions mounting position vertical fastening method for snapping onto 60 mm busbar systems height 200 mm width 90 mm depth 155.1 mm required spacing ● for grounded parts — forwards 0 mm — backwards 0 mm — upwards 20 mm — at the side 9 mm — downwards 10 mm ● for live parts — forwards 0 mm — backwards 0 mm — upwards 20 mm — downwards 10 mm — at the side 9 mm Connections/ Terminals type of electrical connection for main current circuit screw-type terminals type of connectable conductor cross-sections ● for main contacts stranded 0.5 ... 4 mm², 2x (0.75 ... 2.5 mm²) ● at AWG cables for main contacts 2x (20 ... 16), only for contactor 2x (18 ... 14), 2x 12 ● connectable conductor cross-section for main contacts finely stranded with core end processing 0.5 ... 2.5 mm² Safety related data 3RA22101GD152AK6 Page 2/3 1.21.2021 Subject to change without notice © Copyright Siemens B10 value with high demand rate acc. to SN 31920 1 000 000 proportion of dangerous failures with high demand rate acc. to SN 31920 73 % protection class IP on the front acc. to IEC 60529 IP20 touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front Certificates/ approvals For use in hazardous locations General Product Approval Declaration of Conformity Miscellaneous Test Certificates Type Test Certificates/Test Report Marine / Shipping Marine / Shipping Special Test Certificate other Confirmation Railway Vibration and Shock Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RA2210-1GD15-2AK6 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RA2210-1GD15-2AK6 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RA2210-1GD15-2AK6 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RA2210-1GD15-2AK6&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RA2210-1GD15-2AK6/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RA2210-1GD15-2AK6&objecttype=14&gridview=view1 3RA22101GD152AK6 Page 3/4 1.21.2021 Subject to change without notice © Copyright Siemens 3RA22101GD152AK6 Page 4/5 1.21.2021 Subject to change without notice © Copyright Siemens 3RA22101GD152AK6 Page 5/6 1.21.2021 Subject to change without notice © Copyright Siemens last modified: 3RA22101GD152AK6 Page 6/6 12/15/2020 1.21.2021 Subject to change without notice © Copyright Siemens
3RA22101GD152AK6 价格&库存

很抱歉,暂时无法提供与“3RA22101GD152AK6”相匹配的价格&库存,您可以联系我们找货

免费人工找货