3RT10642XB460LA2

3RT10642XB460LA2

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    CONTACTOR AC3:110 KW/400V 2NO+2N

  • 数据手册
  • 价格&库存
3RT10642XB460LA2 数据手册
Data sheet 3RT1064-2XB46-0LA2 Traction contactor, AC-3 225 A, 110 kW / 400 V Coil 24 V DC x (0.7-1.25) PLC input 24-110 V DC Auxiliary contacts 2 NO + 2 NC 3-pole size S10 Busbar connections Coil connection: Spring-type terminal product brand name SIRIUS product designation Contactor design of the product With extended operating range product type designation 3RT1 General technical data size of contactor S10 product extension ● function module for communication No ● auxiliary switch Yes power loss [W] for rated value of the current at AC in hot operating state ● per pole power loss [W] for rated value of the current without load current share typical 51 W 17 W 3.4 W insulation voltage ● of main circuit with degree of pollution 3 rated value 1 000 V ● of auxiliary circuit with degree of pollution 3 rated value 690 V surge voltage resistance ● of main circuit rated value 8 kV ● of auxiliary circuit rated value 6 kV maximum permissible voltage for safe isolation between coil and main contacts acc. to EN 60947-1 690 V shock resistance for railway applications acc. to DIN EN 61373 Category 1, Class B shock resistance at rectangular impulse ● at DC 8,5g / 5 ms, 4,2g / 10 ms shock resistance with sine pulse ● at DC 13,4g / 5 ms, 6,5g / 10 ms mechanical service life (switching cycles) ● of contactor typical 10 000 000 ● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code acc. to IEC 81346-2 Q Substance Prohibitance (Date) 06.09.2016 00:00:00 Ambient conditions installation altitude at height above sea level maximum 3RT10642XB460LA2 Page 1/2 2 000 m 1.21.2021 Subject to change without notice © Copyright Siemens ● ambient temperature during operation -40 ... +70 °C ● ambient temperature during storage -55 ... +80 °C Main circuit number of poles for main current circuit 3 number of NO contacts for main contacts 3 number of NC contacts for main contacts 0 ● operating voltage at AC-3 rated value maximum 1 000 V operational current ● at AC-1 at 400 V at ambient temperature 40 °C rated value 275 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 275 A — up to 690 V at ambient temperature 60 °C rated value 250 A — up to 1000 V at ambient temperature 60 °C rated value 100 A ● at AC-2 at 400 V rated value 225 A ● at AC-3 — at 400 V rated value 225 A — at 500 V rated value 225 A — at 690 V rated value 225 A — at 1000 V rated value 68 A ● at AC-4 at 400 V rated value 195 A minimum cross-section in main circuit ● at maximum AC-1 rated value 150 mm² ● at maximum Ith rated value 150 mm² operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 96 A ● at 690 V rated value 85 A operational current ● at 1 current path at DC-1 — at 24 V rated value 200 A — at 110 V rated value 18 A — at 220 V rated value 3.4 A — at 440 V rated value 0.8 A — at 600 V rated value 0.5 A ● with 2 current paths in series at DC-1 — at 24 V rated value 200 A — at 110 V rated value 200 A — at 220 V rated value 20 A — at 440 V rated value 3.2 A — at 600 V rated value 1.6 A ● with 3 current paths in series at DC-1 — at 24 V rated value 200 A — at 110 V rated value 200 A — at 220 V rated value 200 A — at 440 V rated value 11.5 A — at 600 V rated value 4A operational current ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 200 A — at 110 V rated value 2.5 A — at 220 V rated value 0.6 A — at 440 V rated value 0.17 A — at 600 V rated value 0.12 A ● with 2 current paths in series at DC-3 at DC-5 — at 24 V rated value 3RT10642XB460LA2 Page 2/3 200 A 1.21.2021 Subject to change without notice © Copyright Siemens — at 110 V rated value 200 A — at 220 V rated value 2.5 A — at 440 V rated value 0.65 A — at 600 V rated value 0.37 A ● with 3 current paths in series at DC-3 at DC-5 — at 24 V rated value 200 A — at 110 V rated value 200 A — at 220 V rated value 200 A — at 440 V rated value 1.4 A — at 600 V rated value 0.75 A operating power ● at AC-2 at 400 V rated value 110 kW ● at AC-3 — at 230 V rated value 73 kW — at 400 V rated value 110 kW — at 500 V rated value 160 kW — at 690 V rated value 200 kW — at 1000 V rated value 90 kW operating power for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 54 kW ● at 690 V rated value 82 kW short-time withstand current in cold operating state up to 40 °C ● limited to 1 s switching at zero current maximum 4 000 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 5 s switching at zero current maximum 2 807 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 10 s switching at zero current maximum 2 082 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 30 s switching at zero current maximum 1 397 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 60 s switching at zero current maximum 1 144 A; Use minimum cross-section acc. to AC-1 rated value no-load switching frequency ● at DC 700 1/h operating frequency ● at AC-1 maximum 700 1/h ● at AC-2 maximum 250 1/h ● at AC-3 maximum 500 1/h ● at AC-4 maximum 130 1/h operating frequency ● at DC-1 maximum 350 1/h ● at DC-3 maximum 250 1/h ● at DC-5 maximum 250 1/h Ratings for railway applications thermal current (Ith) up to 690 V ● up to 40 °C according to IEC 60077 rated value 275 A ● up to 70 °C according to IEC 60077 rated value 215 A Control circuit/ Control type of voltage DC type of voltage of the control supply voltage DC control supply voltage at DC ● rated value 24 V consumed current at PLC-control input acc. to IEC 60947-1 maximum 2 mA voltage at PLC-control input rated value 24 V operating range factor control supply voltage rated value of magnet coil at DC ● initial value 0.7 ● full-scale value 1.25 design of the surge suppressor with varistor closing power of magnet coil at DC 580 W holding power of magnet coil at DC 3.4 W 3RT10642XB460LA2 Page 3/4 1.21.2021 Subject to change without notice © Copyright Siemens closing delay ● at DC 45 ... 80 ms opening delay ● at DC 80 ... 100 ms arcing time 10 ... 15 ms control version of the switch operating mechanism PLC-IN or Standard A1 - A2 (adjustable) Auxiliary circuit number of NC contacts for auxiliary contacts ● instantaneous contact number of NO contacts for auxiliary contacts ● instantaneous contact operational current at AC-12 maximum 2 2 2 2 10 A operational current at AC-15 ● at 230 V rated value 6A ● at 400 V rated value 3A ● at 500 V rated value 2A operational current at DC-12 ● at 24 V rated value 10 A ● at 48 V rated value 6A ● at 60 V rated value 6A ● at 110 V rated value 3A ● at 125 V rated value 2A ● at 220 V rated value 1A ● at 600 V rated value 0.15 A operational current at DC-13 ● at 24 V rated value 6A ● at 48 V rated value 2A ● at 60 V rated value 2A ● at 110 V rated value 1A ● at 125 V rated value 0.9 A ● at 220 V rated value 0.3 A ● at 600 V rated value 0.1 A contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 180 A ● at 600 V rated value 182 A yielded mechanical performance [hp] ● for 3-phase AC motor — at 200/208 V rated value 60 hp — at 220/230 V rated value 75 hp — at 460/480 V rated value 150 hp — at 575/600 V rated value 200 hp contact rating of auxiliary contacts according to UL A600 / Q600 Short-circuit protection product function short circuit protection No design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 500 A (690 V, 100 kA) — with type of assignment 2 required gG: 400 A (690 V, 100 kA), aM: 315 A (690 V, 50 kA), BS88: 400 A (415 V, 50 kA) ● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions mounting position with vertical mounting surface +/-90° rotatable, with vertical mounting surface +/- 22.5° tiltable to the front and back fastening method screw fixing ● side-by-side mounting 3RT10642XB460LA2 Page 4/5 Yes 1.21.2021 Subject to change without notice © Copyright Siemens height 210 mm width 145 mm depth 202 mm required spacing ● with side-by-side mounting — forwards 20 mm — upwards 10 mm — downwards 10 mm — at the side 10 mm ● for grounded parts — forwards 20 mm — upwards 10 mm — at the side 10 mm — downwards 10 mm ● for live parts — forwards 20 mm — upwards 10 mm — downwards 10 mm — at the side 10 mm Connections/ Terminals width of connection bar 25 mm thickness of connection bar 6 mm diameter of holes 11 mm number of holes 1 type of electrical connection ● for main current circuit screw-type terminals ● for auxiliary and control circuit spring-loaded terminals type of connectable conductor cross-sections ● for main contacts — solid or stranded ● at AWG cables for main contacts 2x (70 ... 240 mm²) 2/0 ... 500 kcmil type of connectable conductor cross-sections ● for auxiliary contacts — solid 2x (0.25 ... 2.5 mm²) — solid or stranded 2x (0,25 ... 2,5 mm²) — finely stranded with core end processing 2x (0.25 ... 1.5 mm²) — finely stranded without core end processing 2x (0.25 ... 2.5 mm²) ● at AWG cables for auxiliary contacts 2x (24 ... 14) ● AWG number as coded connectable conductor cross section for auxiliary contacts 24 ... 14 Safety related data B10 value with high demand rate acc. to SN 31920 1 000 000 product function ● mirror contact acc. to IEC 60947-4-1 Yes ● positively driven operation acc. to IEC 60947-5-1 No protection class IP on the front acc. to IEC 60529 IP00; IP20 with box terminal/cover touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front with box terminal/cover suitability for use safety-related switching OFF Yes Communication/ Protocol product function bus communication No Certificates/ approvals General Product Approval EMC KC 3RT10642XB460LA2 Page 5/6 1.21.2021 Subject to change without notice © Copyright Siemens Declaration of Conformity Miscellaneous other Miscellaneous Test Certificates Special Test Certificate other Type Test Certificates/Test Report Confirmation Miscellaneous Railway Type Test Certificates/Test Report Special Test Certificate Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT1064-2XB46-0LA2 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT1064-2XB46-0LA2 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT1064-2XB46-0LA2 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT1064-2XB46-0LA2&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT1064-2XB46-0LA2/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT1064-2XB46-0LA2&objecttype=14&gridview=view1 3RT10642XB460LA2 Page 6/7 1.21.2021 Subject to change without notice © Copyright Siemens 3RT10642XB460LA2 Page 7/8 1.21.2021 Subject to change without notice © Copyright Siemens last modified: 3RT10642XB460LA2 Page 8/8 1/12/2021 1.21.2021 Subject to change without notice © Copyright Siemens
3RT10642XB460LA2 价格&库存

很抱歉,暂时无法提供与“3RT10642XB460LA2”相匹配的价格&库存,您可以联系我们找货

免费人工找货