0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RT20252AP00

3RT20252AP00

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIEMENS - 3RT20252AP00 - Contactor, 13 A, DIN Rail, Panel, 690 VAC, 3PST-NO, 3 Pole, 11 kW

  • 数据手册
  • 价格&库存
3RT20252AP00 数据手册
Data sheet 3RT2025-2AP00 power contactor, AC-3e/AC-3, 17 A, 7.5 kW / 400 V, 3-pole, 230 V AC, 50 Hz, auxiliary contacts: 1 NO + 1 NC, spring-loaded terminal, size: S0 product brand name SIRIUS product designation Power contactor product type designation 3RT2 General technical data size of contactor S0 product extension ● function module for communication No ● auxiliary switch Yes power loss [W] for rated value of the current ● at AC in hot operating state 1.8 W ● at AC in hot operating state per pole 0.6 W ● without load current share typical 1.9 W type of calculation of power loss depending on pole quadratic insulation voltage ● of main circuit with degree of pollution 3 rated value 690 V ● of auxiliary circuit with degree of pollution 3 rated value 690 V surge voltage resistance ● of main circuit rated value 6 kV ● of auxiliary circuit rated value 6 kV maximum permissible voltage for protective separation between coil and main contacts according to EN 60947-1 400 V shock resistance at rectangular impulse ● at AC 7,5g / 5 ms, 4,7g / 10 ms shock resistance with sine pulse ● at AC 11,8g / 5 ms, 7,4g / 10 ms mechanical service life (operating cycles) ● of contactor typical 10 000 000 ● of the contactor with added electronically optimized auxiliary switch block typical 5 000 000 ● of the contactor with added auxiliary switch block typical 10 000 000 reference code according to IEC 81346-2 Q Substance Prohibitance (Date) 10/01/2009 Ambient conditions installation altitude at height above sea level maximum 2 000 m ambient temperature ● during operation -25 ... +60 °C ● during storage -55 ... +80 °C relative humidity minimum 10 % relative humidity at 55 °C according to IEC 60068-2-30 maximum 95 % Environmental footprint 3RT20252AP00 Page 1/9 4/23/2024 Subject to change without notice © Copyright Siemens Environmental Product Declaration(EPD) Yes Global Warming Potential [CO2 eq] total 74.2 kg Global Warming Potential [CO2 eq] during manufacturing 1.9 kg Global Warming Potential [CO2 eq] during operation 72.4 kg Global Warming Potential [CO2 eq] after end of life -0.117 kg Main circuit number of poles for main current circuit 3 number of NO contacts for main contacts 3 operating voltage ● at AC-3 rated value maximum 690 V ● at AC-3e rated value maximum 690 V operational current ● at AC-1 at 400 V at ambient temperature 40 °C rated value 40 A ● at AC-1 — up to 690 V at ambient temperature 40 °C rated value 40 A — up to 690 V at ambient temperature 60 °C rated value 35 A ● at AC-3 — at 400 V rated value 17 A — at 500 V rated value 17 A — at 690 V rated value 13 A ● at AC-3e — at 400 V rated value 17 A — at 500 V rated value 17 A — at 690 V rated value 13 A ● at AC-4 at 400 V rated value 15.5 A ● at AC-5a up to 690 V rated value 35.2 A ● at AC-5b up to 400 V rated value 14.1 A ● at AC-6a — up to 230 V for current peak value n=20 rated value 11.4 A — up to 400 V for current peak value n=20 rated value 11.4 A — up to 500 V for current peak value n=20 rated value 11.4 A — up to 690 V for current peak value n=20 rated value 11.3 A ● at AC-6a — up to 230 V for current peak value n=30 rated value 7.6 A — up to 400 V for current peak value n=30 rated value 7.6 A — up to 500 V for current peak value n=30 rated value 7.6 A — up to 690 V for current peak value n=30 rated value 7.6 A minimum cross-section in main circuit at maximum AC-1 rated value 10 mm² operational current for approx. 200000 operating cycles at AC-4 ● at 400 V rated value 7.7 A ● at 690 V rated value 7.7 A operational current ● at 1 current path at DC-1 — at 24 V rated value 35 A — at 60 V rated value 20 A — at 110 V rated value 4.5 A — at 220 V rated value 1A — at 440 V rated value 0.4 A — at 600 V rated value 0.25 A ● with 2 current paths in series at DC-1 — at 24 V rated value 35 A — at 60 V rated value 35 A — at 110 V rated value 35 A — at 220 V rated value 5A — at 440 V rated value 1A — at 600 V rated value 0.8 A ● with 3 current paths in series at DC-1 3RT20252AP00 Page 2/9 4/23/2024 Subject to change without notice © Copyright Siemens — at 24 V rated value 35 A — at 60 V rated value 35 A — at 110 V rated value 35 A — at 220 V rated value 35 A — at 440 V rated value 2.9 A — at 600 V rated value 1.4 A ● at 1 current path at DC-3 at DC-5 — at 24 V rated value 20 A — at 60 V rated value 5A — at 220 V rated value 1A — at 440 V rated value 0.09 A — at 600 V rated value 0.06 A ● with 2 current paths in series at DC-3 at DC-5 — at 24 V rated value 35 A — at 60 V rated value 35 A — at 110 V rated value 15 A — at 220 V rated value 3A — at 440 V rated value 0.27 A — at 600 V rated value 0.16 A ● with 3 current paths in series at DC-3 at DC-5 — at 24 V rated value 35 A — at 60 V rated value 35 A — at 110 V rated value 35 A — at 220 V rated value 10 A — at 440 V rated value 0.6 A — at 600 V rated value 0.6 A operating power ● at AC-3 — at 230 V rated value 4 kW — at 400 V rated value 7.5 kW — at 500 V rated value 7.5 kW — at 690 V rated value 11 kW ● at AC-3e — at 230 V rated value 4 kW — at 400 V rated value 7.5 kW — at 500 V rated value 7.5 kW — at 690 V rated value 11 kW operating power for approx. 200000 operating cycles at AC4 ● at 400 V rated value 3.5 kW ● at 690 V rated value 6 kW operating apparent power at AC-6a ● up to 230 V for current peak value n=20 rated value 4.5 kVA ● up to 400 V for current peak value n=20 rated value 7.8 kVA ● up to 500 V for current peak value n=20 rated value 9.9 kVA ● up to 690 V for current peak value n=20 rated value 13.6 kVA operating apparent power at AC-6a ● up to 230 V for current peak value n=30 rated value 3 kVA ● up to 400 V for current peak value n=30 rated value 5.2 kVA ● up to 500 V for current peak value n=30 rated value 6.6 kVA ● up to 690 V for current peak value n=30 rated value 9.1 kVA short-time withstand current in cold operating state up to 40 °C ● limited to 1 s switching at zero current maximum 225 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 5 s switching at zero current maximum 225 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 10 s switching at zero current maximum 189 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 30 s switching at zero current maximum 140 A; Use minimum cross-section acc. to AC-1 rated value ● limited to 60 s switching at zero current maximum 115 A; Use minimum cross-section acc. to AC-1 rated value no-load switching frequency ● at AC 5 000 1/h operating frequency 3RT20252AP00 Page 3/9 4/23/2024 Subject to change without notice © Copyright Siemens ● at AC-1 maximum 1 000 1/h ● at AC-2 maximum 1 000 1/h ● at AC-3 maximum 1 000 1/h ● at AC-3e maximum 1 000 1/h ● at AC-4 maximum 300 1/h Control circuit/ Control type of voltage of the control supply voltage AC control supply voltage at AC ● at 50 Hz rated value 230 V operating range factor control supply voltage rated value of magnet coil at AC ● at 50 Hz 0.8 ... 1.1 apparent pick-up power of magnet coil at AC ● at 50 Hz 65 VA inductive power factor with closing power of the coil ● at 50 Hz 0.82 apparent holding power of magnet coil at AC ● at 50 Hz 7.6 VA inductive power factor with the holding power of the coil ● at 50 Hz 0.25 closing delay ● at AC 8 ... 40 ms opening delay ● at AC 4 ... 16 ms arcing time 10 ... 10 ms control version of the switch operating mechanism Standard A1 - A2 Auxiliary circuit number of NC contacts for auxiliary contacts instantaneous contact 1 number of NO contacts for auxiliary contacts instantaneous contact 1 operational current at AC-12 maximum 10 A operational current at AC-15 ● at 230 V rated value 10 A ● at 400 V rated value 3A ● at 500 V rated value 2A ● at 690 V rated value 1A operational current at DC-12 ● at 24 V rated value 10 A ● at 48 V rated value 6A ● at 60 V rated value 6A ● at 110 V rated value 3A ● at 125 V rated value 2A ● at 220 V rated value 1A ● at 600 V rated value 0.15 A operational current at DC-13 ● at 24 V rated value 10 A ● at 48 V rated value 2A ● at 60 V rated value 2A ● at 110 V rated value 1A ● at 125 V rated value 0.9 A ● at 220 V rated value 0.3 A ● at 600 V rated value 0.1 A contact reliability of auxiliary contacts 1 faulty switching per 100 million (17 V, 1 mA) UL/CSA ratings full-load current (FLA) for 3-phase AC motor ● at 480 V rated value 14 A ● at 600 V rated value 17 A yielded mechanical performance [hp] ● for single-phase AC motor — at 110/120 V rated value 3RT20252AP00 Page 4/9 1 hp 4/23/2024 Subject to change without notice © Copyright Siemens — at 230 V rated value 3 hp ● for 3-phase AC motor — at 200/208 V rated value 3 hp — at 220/230 V rated value 5 hp — at 460/480 V rated value 10 hp — at 575/600 V rated value 15 hp contact rating of auxiliary contacts according to UL A600 / P600 Short-circuit protection design of the fuse link ● for short-circuit protection of the main circuit — with type of coordination 1 required gG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA) — with type of assignment 2 required gG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA) ● for short-circuit protection of the auxiliary switch required gG: 10 A (500 V, 1 kA) Installation/ mounting/ dimensions mounting position +/-180° rotation possible on vertical mounting surface; can be tilted forward and backward by +/- 22.5° on vertical mounting surface fastening method screw and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715 height 102 mm width 45 mm depth 97 mm required spacing ● with side-by-side mounting — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 0 mm ● for grounded parts — forwards 10 mm — upwards 10 mm — at the side 6 mm — downwards 10 mm ● for live parts — forwards 10 mm — upwards 10 mm — downwards 10 mm — at the side 6 mm Connections/ Terminals type of electrical connection ● for main current circuit spring-loaded terminals ● for auxiliary and control circuit spring-loaded terminals ● at contactor for auxiliary contacts Spring-type terminals ● of magnet coil Spring-type terminals type of connectable conductor cross-sections ● for main contacts — solid 2x (1 ... 10 mm²) — solid or stranded 2x (1 ... 10 mm²) — finely stranded with core end processing 2x (1 ... 6 mm²) — finely stranded without core end processing 2x (1 ... 6 mm²) ● for AWG cables for main contacts 2x (18 ... 8) connectable conductor cross-section for main contacts ● solid 1 ... 10 mm² ● stranded 1 ... 10 mm² ● finely stranded with core end processing 1 ... 6 mm² ● finely stranded without core end processing 1 ... 6 mm² connectable conductor cross-section for auxiliary contacts ● solid or stranded 0.5 ... 2.5 mm² ● finely stranded with core end processing 0.5 ... 1.5 mm² ● finely stranded without core end processing 0.5 ... 2.5 mm² type of connectable conductor cross-sections ● for auxiliary contacts — solid or stranded 3RT20252AP00 Page 5/9 2x (0.5 ... 2.5 mm²) 4/23/2024 Subject to change without notice © Copyright Siemens — finely stranded with core end processing 2x (0.5 ... 1.5 mm²) — finely stranded without core end processing 2x (0.5 ... 2.5 mm²) ● for AWG cables for auxiliary contacts 2x (20 ... 14) AWG number as coded connectable conductor cross section ● for main contacts 18 ... 8 ● for auxiliary contacts 20 ... 14 Safety related data product function ● mirror contact according to IEC 60947-4-1 Yes suitability for use safety-related switching OFF Yes; applies only to contactor operating mechanism proportion of dangerous failures ● with low demand rate according to SN 31920 40 % ● with high demand rate according to SN 31920 73 % B10 value with high demand rate according to SN 31920 1 000 000 failure rate [FIT] with low demand rate according to SN 31920 100 FIT IEC 61508 T1 value ● for proof test interval or service life according to IEC 61508 20 a Electrical Safety protection class IP on the front according to IEC 60529 IP20 touch protection on the front according to IEC 60529 finger-safe, for vertical contact from the front Approvals Certificates General Product Approval Confirmation General Product Approval EMV Functional Saftey KC Type Examination Certificate Test Certificates Special Test Certificate Type Test Certificates/Test Report Marine / Shipping Marine / Shipping other Miscellaneous Railway Confirmation Confirmation Environment Special Test Certificate Environment Environmental Confirmations Further information 3RT20252AP00 Page 6/9 4/23/2024 Subject to change without notice © Copyright Siemens Information on the packaging https://support.industry.siemens.com/cs/ww/en/view/109813875 Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RT2025-2AP00 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RT2025-2AP00 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RT2025-2AP00 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RT2025-2AP00&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RT2025-2AP00/char Further characteristics (e.g. electrical endurance, switching frequency) http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RT2025-2AP00&objecttype=14&gridview=view1 3RT20252AP00 Page 7/9 4/23/2024 Subject to change without notice © Copyright Siemens 3RT20252AP00 Page 8/9 4/23/2024 Subject to change without notice © Copyright Siemens 3/L2 5/L3 13 4/T2 6/T3 14 21 1/L1 2/T1 A1 last modified: 3RT20252AP00 Page 9/9 22 A2 -Q 3/15/2024 4/23/2024 Subject to change without notice © Copyright Siemens
3RT20252AP00 价格&库存

很抱歉,暂时无法提供与“3RT20252AP00”相匹配的价格&库存,您可以联系我们找货

免费人工找货