0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
3RW50566TB04

3RW50566TB04

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    3RW50 480V 171A 24V SCREW THERM

  • 数据手册
  • 价格&库存
3RW50566TB04 数据手册
Data sheet 3RW5056-6TB04 SIRIUS soft starter 200-480 V 171 A, 24 V AC/DC Screw terminals Thermistor input product brand name SIRIUS product category Hybrid switching devices product designation Soft starter product type designation 3RW50 manufacturer's article number ● of standard HMI module usable 3RW5980-0HS01 ● of high feature HMI module usable 3RW5980-0HF00 ● of communication module PROFINET standard usable 3RW5980-0CS00 ● of communication module PROFIBUS usable 3RW5980-0CP00 ● of communication module Modbus TCP usable 3RW5980-0CT00 ● of communication module Modbus RTU usable 3RW5980-0CR00 ● of communication module Ethernet/IP 3RW5980-0CE00 ● of circuit breaker usable at 400 V 3VA2220-7MN32-0AA0; Type of assignment 1, Iq = 20 kA ● of circuit breaker usable at 500 V 3VA2220-7MN32-0AA0; Type of assignment 1, Iq = 20 kA ● of the gG fuse usable up to 690 V 3NA3244-6; Type of coordination 1, Iq = 65 kA ● of full range R fuse link for semiconductor protection usable up to 690 V 3NE1 230-0; Type of coordination 2, Iq = 65 kA ● of back-up R fuse link for semiconductor protection usable up to 690 V 3NE3 335; Type of coordination 2, Iq = 65 kA ● of line contactor usable up to 480 V 3RT1056 ● of line contactor usable up to 690 V 3RT1064 General technical data starting voltage [%] 30 ... 100 % stopping voltage [%] 50 ... 50 % start-up ramp time of soft starter 0 ... 20 s ramp-down time of soft starter 0 ... 20 s current limiting value [%] adjustable 130 ... 700 % accuracy class acc. to IEC 61557-12 5% certificate of suitability ● CE marking Yes ● UL approval Yes ● CSA approval Yes product component is supported ● HMI-Standard Yes ● HMI-High Feature Yes product feature integrated bypass contact system Yes number of controlled phases 2 3RW50566TB04 Page 1/2 12.21.2020 Subject to change without notice © Copyright Siemens trip class CLASS 10A / 10E (preset) / 20E; acc. to IEC 60947-4-2 buffering time in the event of power failure ● for main current circuit 100 ms ● for control circuit 100 ms insulation voltage rated value 600 V degree of pollution 3, acc. to IEC 60947-4-2 impulse voltage rated value 6 kV blocking voltage of the thyristor maximum 1 400 V service factor 1 reference code acc. to IEC 81346-2 Q product function ● ramp-up (soft starting) Yes ● ramp-down (soft stop) Yes ● Soft Torque Yes ● adjustable current limitation Yes ● pump ramp down Yes ● intrinsic device protection Yes ● motor overload protection Yes; Full motor protection (thermistor motor protection and electronic motor overload protection) ● evaluation of thermistor motor protection Yes; Type A PTC or Klixon / Thermoclick ● auto-RESET Yes ● manual RESET Yes ● remote reset Yes; By turning off the control supply voltage ● communication function Yes ● operating measured value display Yes; Only in conjunction with special accessories ● error logbook Yes; Only in conjunction with special accessories ● via software parameterizable No ● via software configurable Yes ● PROFIenergy Yes; in connection with the PROFINET Standard communication module ● voltage ramp Yes ● torque control No ● analog output No Power Electronics operational current ● at 40 °C rated value 171 A ● at 50 °C rated value 153 A ● at 60 °C rated value 141 A operating voltage ● rated value 200 ... 480 V relative negative tolerance of the operating voltage -15 % relative positive tolerance of the operating voltage 10 % operating power for 3-phase motors ● at 230 V at 40 °C rated value 45 kW ● at 400 V at 40 °C rated value 90 kW Operating frequency 1 rated value 50 Hz Operating frequency 2 rated value 60 Hz relative negative tolerance of the operating frequency -10 % relative positive tolerance of the operating frequency 10 % adjustable motor current ● at rotary coding switch on switch position 1 81 A ● at rotary coding switch on switch position 2 87 A ● at rotary coding switch on switch position 3 93 A ● at rotary coding switch on switch position 4 99 A ● at rotary coding switch on switch position 5 105 A ● at rotary coding switch on switch position 6 111 A ● at rotary coding switch on switch position 7 117 A ● at rotary coding switch on switch position 8 123 A ● at rotary coding switch on switch position 9 129 A 3RW50566TB04 Page 2/3 12.21.2020 Subject to change without notice © Copyright Siemens ● at rotary coding switch on switch position 10 135 A ● at rotary coding switch on switch position 11 141 A ● at rotary coding switch on switch position 12 147 A ● at rotary coding switch on switch position 13 153 A ● at rotary coding switch on switch position 14 159 A ● at rotary coding switch on switch position 15 165 A ● at rotary coding switch on switch position 16 171 A ● minimum 81 A minimum load [%] 15 %; Relative to smallest settable Ie power loss [W] for rated value of the current at AC ● at 40 °C after startup 29 W ● at 50 °C after startup 23 W ● at 60 °C after startup 20 W power loss [W] at AC at current limitation 350 % ● at 40 °C during startup 1 751 W ● at 50 °C during startup 1 478 W ● at 60 °C during startup 1 308 W type of the motor protection Electronic, tripping in the event of thermal overload of the motor Control circuit/ Control type of voltage of the control supply voltage AC/DC ● control supply voltage at AC at 50 Hz rated value 24 V ● control supply voltage at AC at 60 Hz rated value 24 V relative negative tolerance of the control supply voltage at AC at 50 Hz -20 % relative positive tolerance of the control supply voltage at AC at 50 Hz 20 % relative negative tolerance of the control supply voltage at AC at 60 Hz -20 % relative positive tolerance of the control supply voltage at AC at 60 Hz 20 % control supply voltage frequency 50 ... 60 Hz relative negative tolerance of the control supply voltage frequency -10 % relative positive tolerance of the control supply voltage frequency 10 % ● control supply voltage at DC rated value 24 V relative negative tolerance of the control supply voltage at DC -20 % relative positive tolerance of the control supply voltage at DC 20 % control supply current in standby mode rated value 160 mA holding current in bypass operation rated value 360 mA locked-rotor current at close of bypass contact maximum 7.6 A inrush current peak at application of control supply voltage maximum 3.3 A duration of inrush current peak at application of control supply voltage 12.1 ms design of the overvoltage protection Varistor design of short-circuit protection for control circuit 4 A gG fuse (Icu=1 kA), 6 A quick-acting fuse (Icu=1 kA), C1 miniature circuit breaker (Icu= 600 A), C6 miniature circuit breaker (Icu= 300 A); Is not part of scope of supply Inputs/ Outputs number of digital inputs 1 number of inputs for thermistor connection 1; Type A PTC or Klixon / Thermoclick number of digital outputs 3 ● not parameterizable 2 digital output version 2 normally-open contacts (NO) / 1 changeover contact (CO) number of analog outputs 0 Installation/ mounting/ dimensions mounting position 3RW50566TB04 Page 3/4 with vertical mounting surface +/-90° rotatable, with vertical mounting 12.21.2020 Subject to change without notice © Copyright Siemens surface +/- 22.5° tiltable to the front and back fastening method screw fixing height 198 mm width 120 mm depth 249 mm required spacing with side-by-side mounting ● forwards 10 mm ● backwards 0 mm ● upwards 100 mm ● downwards 75 mm ● at the side 5 mm weight without packaging 5.2 kg Connections/ Terminals type of electrical connection ● for main current circuit busbar connection ● for control circuit screw-type terminals width of connection bar maximum 25 mm wire length for thermistor connection ● with conductor cross-section = 0.5 mm² maximum 50 m ● with conductor cross-section = 1.5 mm² maximum 150 m ● with conductor cross-section = 2.5 mm² maximum 250 m type of connectable conductor cross-sections ● for main contacts for box terminal using the front clamping point solid 16 ... 120 mm² ● for main contacts for box terminal using the front clamping point finely stranded with core end processing 16 ... 120 mm² ● for main contacts for box terminal using the front clamping point finely stranded without core end processing 10 ... 120 mm² ● for main contacts for box terminal using the front clamping point stranded 16 ... 70 mm² ● at AWG cables for main contacts for box terminal using the front clamping point 6 ... 250 kcmil ● for main contacts for box terminal using the back clamping point solid 16 ... 120 mm² ● at AWG cables for main contacts for box terminal using the back clamping point 6 ... 250 kcmil ● for main contacts for box terminal using both clamping points solid max. 1x 95 mm², 1x 120 mm² ● for main contacts for box terminal using both clamping points finely stranded with core end processing max. 1x 95 mm², 1x 120 mm² ● for main contacts for box terminal using both clamping points finely stranded without core end processing max. 1x 95 mm², 1x 120 mm² ● for main contacts for box terminal using both clamping points stranded max. 2x 120 mm² ● for main contacts for box terminal using the back clamping point finely stranded with core end processing 16 ... 120 mm² ● for main contacts for box terminal using the back clamping point finely stranded without core end processing 10 ... 120 mm² ● for main contacts for box terminal using the back clamping point stranded 16 ... 120 mm² type of connectable conductor cross-sections ● at AWG cables for main current circuit solid 4 ... 250 kcmil ● for DIN cable lug for main contacts stranded 16 ... 95 mm² ● for DIN cable lug for main contacts finely stranded 25 ... 120 mm² type of connectable conductor cross-sections ● for control circuit solid 1x (0.5 ... 4.0 mm²), 2x (0.5 ... 2.5 mm²) ● for control circuit finely stranded with core end 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) 3RW50566TB04 Page 4/5 12.21.2020 Subject to change without notice © Copyright Siemens processing ● at AWG cables for control circuit solid 1x (20 ... 12), 2x (20 ... 14) wire length ● between soft starter and motor maximum 800 m ● at the digital inputs at AC maximum 1 000 m tightening torque ● for main contacts with screw-type terminals 10 ... 14 N·m ● for auxiliary and control contacts with screw-type terminals 0.8 ... 1.2 N·m tightening torque [lbf·in] ● for main contacts with screw-type terminals 89 ... 124 lbf·in ● for auxiliary and control contacts with screw-type terminals 7 ... 10.3 lbf·in Ambient conditions installation altitude at height above sea level maximum 5 000 m; Derating as of 1000 m, see manual ● ambient temperature during operation -25 ... +60 °C; Please observe derating at temperatures of 40 °C or above ● ambient temperature during storage and transport -40 ... +80 °C environmental category ● during operation acc. to IEC 60721 3K6 (no ice formation, only occasional condensation), 3C3 (no salt mist), 3S2 (sand must not get into the devices), 3M6 ● during storage acc. to IEC 60721 1K6 (only occasional condensation), 1C2 (no salt mist), 1S2 (sand must not get inside the devices), 1M4 ● during transport acc. to IEC 60721 2K2, 2C1, 2S1, 2M2 (max. fall height 0.3 m) EMC emitted interference acc. to IEC 60947-4-2: Class A Communication/ Protocol communication module is supported ● PROFINET standard Yes ● EtherNet/IP Yes ● Modbus RTU Yes ● Modbus TCP Yes ● PROFIBUS Yes UL/CSA ratings manufacturer's article number ● of circuit breaker — usable for Standard Faults at 460/480 V according to UL Siemens type: 3VA5225, max. 250 A; Iq = 10 kA — usable for High Faults at 460/480 V according to UL Siemens type: 3VA52, max. 250 A; Iq max = 65 kA ● of the fuse — usable for Standard Faults up to 575/600 V according to UL Type: Class RK5 / K5, max. 400 A; Iq = 10 kA — usable for High Faults up to 575/600 V according to UL Type: Class J, max. 350 A; Iq = 100 kA operating power [hp] for 3-phase motors ● at 200/208 V at 50 °C rated value 50 hp ● at 220/230 V at 50 °C rated value 50 hp ● at 460/480 V at 50 °C rated value 100 hp Safety related data protection class IP on the front acc. to IEC 60529 IP00; IP20 with cover touch protection on the front acc. to IEC 60529 finger-safe, for vertical contact from the front with cover ATEX certificate of suitability ● ATEX Yes ● IECEx Yes hardware fault tolerance acc. to IEC 61508 relating to ATEX 0 PFDavg with low demand rate acc. to IEC 61508 relating to ATEX 0.09 PFHD with high demand rate acc. to EN 62061 relating 0.000009 1/h 3RW50566TB04 Page 5/6 12.21.2020 Subject to change without notice © Copyright Siemens to ATEX Safety Integrity Level (SIL) acc. to IEC 61508 relating to ATEX SIL1 T1 value for proof test interval or service life acc. to IEC 61508 relating to ATEX 3y Certificates/ approvals General Product Approval Declaration of Conformity Miscellaneous For use in hazardous locations Test Certificates Type Test Certificates/Test Report other Type Test Certificates/Test Report Confirmation Confirmation Further information Information- and Downloadcenter (Catalogs, Brochures,…) https://www.siemens.com/ic10 Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=3RW5056-6TB04 Cax online generator http://support.automation.siemens.com/WW/CAXorder/default.aspx?lang=en&mlfb=3RW5056-6TB04 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/3RW5056-6TB04 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=3RW5056-6TB04&lang=en Characteristic: Tripping characteristics, I²t, Let-through current https://support.industry.siemens.com/cs/ww/en/ps/3RW5056-6TB04/char Characteristic: Installation altitude http://www.automation.siemens.com/bilddb/index.aspx?view=Search&mlfb=3RW5056-6TB04&objecttype=14&gridview=view1 Simulation Tool for Soft Starters (STS) https://support.industry.siemens.com/cs/ww/en/view/101494917 3RW50566TB04 Page 6/7 12.21.2020 Subject to change without notice © Copyright Siemens 3RW50566TB04 Page 7/8 12.21.2020 Subject to change without notice © Copyright Siemens last modified: 3RW50566TB04 Page 8/8 12/15/2020 12.21.2020 Subject to change without notice © Copyright Siemens
3RW50566TB04 价格&库存

很抱歉,暂时无法提供与“3RW50566TB04”相匹配的价格&库存,您可以联系我们找货

免费人工找货