6ES7136-6RA00-0BF0.

6ES7136-6RA00-0BF0.

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIEMENS - 6ES7136-6RA00-0BF0. - ELECTRONIC MOD, 5A, 24VDC, 1 DIGIAL O/P

  • 数据手册
  • 价格&库存
6ES7136-6RA00-0BF0. 数据手册
Data sheet 6ES7136-6RA00-0BF0 SIMATIC DP, Electronics module f. ET200SP, F-RQ 1x 24 V DC/24..230VAC/5A ST, 20 mm overall width, 1 relay output (2 NO) Summation output current 5 A, load voltage 24 V DC and 24.. 230 V AC, Can be used up to PL E (ISO 13849-1: 2008)/ SIL 3 (IEC 61508: 2010) if control takes place by (e.g. 6ES7136-6DB00-0CA0) FDQ General information Product type designation F-RQ 24 ... 48VDC/24 ... 230VAC/5A ST usable BaseUnits BU type F0 Color code for module-specific color identification plate CC42 Product function ● I&M data Yes; I&M0 to I&M3 Engineering with ● STEP 7 TIA Portal configurable/integrated from version V13 ● STEP 7 configurable/integrated from version V5.5 SP4 and higher ● PROFINET from GSD version/GSD revision V2.31 Supply voltage Rated value (DC) 24 V; Coil voltage permissible range, lower limit (DC) 20.4 V permissible range, upper limit (DC) 28.8 V power supply according to NEC Class 2 required No Power Power available from the backplane bus 100 mW Power loss Power loss, typ. 1W Address area Address space per module ● Inputs 1 byte Hardware configuration Automatic encoding Yes ● Mechanical coding element Yes ● Type of mechanical coding element type C Digital outputs Type of digital output Relays Number of digital outputs 1 Limitation of inductive shutdown voltage to No Controlling a digital input Yes Switching capacity of the outputs ● with resistive load, max. 5A ● on lamp load, max. 25 W Switching frequency ● with resistive load, max. 2 Hz ● with inductive load, max. 0.1 Hz; See data in manual ● with inductive load (acc. to IEC 60947-5-1, DC13), max. 0.1 Hz ● with inductive load (acc. to IEC 60947-5-1, AC15), max. 2 Hz Total current of the outputs (per module) 6ES71366RA000BF0 Page 1/3 5/7/2024 Subject to change without notice © Copyright Siemens horizontal installation — up to 40 °C, max. 5 A; note derating data in the manual — up to 50 °C, max. 4 A; note derating data in the manual — up to 60 °C, max. 3 A; note derating data in the manual vertical installation — up to 50 °C, max. 3 A; note derating data in the manual Relay outputs ● Number of relay outputs 1; 2 NO contacts ● Rated supply voltage of relay coil L+ (DC) 24 V ● Current consumption of relays (coil current of all relays), max. 70 mA ● external protection for relay outputs yes; 6 A, see data in manual ● Relay approved acc. to UL 508 Yes; Pilot Duty B300, R300 Switching capacity of contacts — with inductive load, max. see additional description in the manual — with resistive load, max. see additional description in the manual — Thermal continuous current, max. 5A — Switching current, min. 1 mA — Switching current after exceeding 300 mA, min. 10 mA — Switching current after exceeding 300 mA, max. 5A — Rated switching voltage (DC) 24 V — Rated switching voltage (AC) 230 V Cable length ● shielded, max. 500 m; for load contacts ● unshielded, max. 300 m; for load contacts ● Control cable (input), max. 10 m Interrupts/diagnostics/status information Diagnostics function Yes Diagnostics indication LED ● RUN LED Yes; green/red DIAG LED ● Channel status display Yes; green LED Potential separation Potential separation channels ● between the channels Yes; for SELV / PELV only ● between the channels and backplane bus Yes ● between the channels and the power supply of the electronics Yes Permissible potential difference between channels and backplane bus/supply voltage 250 V AC (reinforced insulation) Isolation Isolation tested with 2 545 V DC/2 s (routine test) Overvoltage category III (according to IEC/EN 61131-2:2007 and EN 298:2012), II (according to IEC 61131-2:2017 and IEC 61010-2-201) tested with ● between channels and backplane bus/supply voltage DC 2 545 V 2 s (routine test), impulse voltage test DC 7 200 V / 5 positive and 5 negative pulses (type test) ● between backplane bus and supply voltage 707 V DC (type test) Standards, approvals, certificates Suitable for safety functions Yes Highest safety class achievable in safety mode ● Performance level according to ISO 13849-1 PLe ● Category according to ISO 13849-1 4 ● SIL acc. to IEC 61508 SIL 3 Probability of failure (for service life of 20 years and repair time of 100 hours) — Low demand mode: PFDavg in accordance with SIL2 < 1.00E-04, function test 1x per year — Low demand mode: PFDavg in accordance with SIL3 < 1.00E-05, function test 1x per month — High demand/continuous mode: PFH in accordance with SIL2 < 1.00E-08 1/h, function test 1x per year — High demand/continuous mode: PFH in accordance with SIL3 < 6.00E-09 1/h, function test 1x per month Ambient conditions 6ES71366RA000BF0 Page 2/3 5/7/2024 Subject to change without notice © Copyright Siemens Ambient temperature during operation ● horizontal installation, min. 0 °C ● horizontal installation, max. 60 °C ● vertical installation, min. 0 °C ● vertical installation, max. 50 °C Dimensions Width 20 mm Height 73 mm Depth 58 mm Weights Weight, approx. 56 g last modified: 3/12/2024 6ES71366RA000BF0 Page 3/3 5/7/2024 Subject to change without notice © Copyright Siemens
6ES7136-6RA00-0BF0. 价格&库存

很抱歉,暂时无法提供与“6ES7136-6RA00-0BF0.”相匹配的价格&库存,您可以联系我们找货

免费人工找货