L6712 L6712A
TWO-PHASE INTERLEAVED DC/DC CONTROLLER
1
■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■ ■
Features
2 PHASE OPERATION WITH SYNCHRONOUS RECTIFIER CONTROL ULTRA FAST LOAD TRANSIENT RESPONSE INTEGRATED HIGH CURRENT GATE DRIVERS: UP TO 2A GATE CURRENT 3 BIT PROGRAMMABLE OUTPUT FROM 0.900V TO 3.300V OR WITH EXTERNAL REF. ±0.9% OUTPUT VOLTAGE ACCURACY 3mA CAPABLE AVAILABLE REFERENCE INTEGRATED PROGRAMMABLE REMOTE SENSE AMPLIFIER PROGRAMMABLE DROOP EFFECT 10% ACTIVE CURRENT SHARING ACCURACY DIGITAL 2048 STEP SOFT-START CROWBAR LATCHED OVERVOLTAGE PROT. NON-LATCHED UNDERVOLTAGE PROT. OVERCURRENT PROTECTION REALIZED USING THE LOWER MOSFET'S RdsON OR A SENSE RESISTOR OSCILLATOR EXTERNALLY ADJUSTABLE AND INTERNALLY FIXED AT 150kHZ POWER GOOD OUTPUT AND INHIBIT FUNCTION PACKAGES: SO-28 & VFQFPN-36
Figure 1. Packages
SO28
VFQFPN-36 (6x6x1.0mm)
Table 1. Order Codes
Tube L6712D, SO L6712AD L6712Q, VFQFPN L6712AQ Package Tape & Reel L6712DTR, L6712ADTR L6712QTR, L6712AQTR
■ ■ ■
1.1 Applications ■ HIGH CURRENT DC/DC CONVERTERS ■ DISTRIBUTED POWER SUPPLY
2
Description
The device implements a dual-phase step-down controller with a 180 phase-shift between each phase
optimized for high current DC/DC applications. Output voltage can be programmed through the integrated DAC from 0.900V to 3.300V; programming the "111" code, an external reference from 0.800V to 3.300V is used for the regulation. Programmable Remote Sense Amplifier avoids use of external resistor divider and recovers losses along distribution line. The device assures a fast protection against load over current and Over / Under voltage.An internal crowbar is provided turning on the low side mosfet if Over-voltage is detected. Output current is limited working in Constant Current mode: when Under Voltage is detected, the device resets, restarting operation.
June 2005
Rev. 3 1/29
L6712A L6712
Figure 2. Block Diagram
OSC / INH SGND VCCDR BOOT1
LOGIC PWM ADAPTIVE ANTI CROSS CONDUCTION
BAND-GAP REFERENCE
2 PHASE OSCILLATOR
HS
UGATE1 PHASE1
PGOOD
PWM1
CURRENT CORRECTION
VID2 VID1 VID0
DAC
LOGIC AND PROTECTIONS
VCC VCCDR
CH1 OCP
LS
LGATE1 ISEN1
CH1 OCP
CH2 OCP
TOTAL CURRENT CURRENT AVG
CURRENT READING
PGNDS1 PGND
DIGITAL SOFT-START
CURRENT READING
PGNDS2 ISEN2
CURRENT CORRECTION
REF_IN/OUT
IDROOP
CH2 OCP
FBG
IFB_START
LOGIC PWM ADAPTIVE ANTI CROSS CONDUCTION
VPROG
LS
LGATE2
PHASE2 HS UGATE2 BOOT2
FBR REMOTE AMPLIFIER
PWM2
ERROR AMPLIFIER
Vcc
VSEN
DROOP FB
COMP
Vcc
Table 2. Absolute Maximum Ratings
Symbol VCC, VCCDR VBOOT-VPHASE VUGATE1-VPHASE1 VUGATE2-VPHASE2 LGATE1, PHASE1, LGATE2, PHASE2 to PGND VID0 to VID2 All other pins to PGND VPHASEx UGATEX Pins OTHER PINS Sustainable Peak Voltage. T 35µA).
■ L6712 - Dynamic Maximum Duty Cycle Limitation The maximum duty cycle is limited as a function of the measured current and, since the oscillator frequency is fixed once programmed, imply a maximum on-time limitation as follow (where T is the switching period T=1/fSW and IOUT is the output current): ⎧ R SENSE ⎪ T = 0.80 ⋅ T I FB = 0 µ A T ON,MAX = ( 0.80 – I FB ⋅ 5.73k ) ⋅ T = ⎛ 0.80 – --------------------- ⋅ I OUT ⋅ 5.73k⎞ ⋅ T = ⎨ ⎝ ⎠ Rg ⎪ T = 0.40 ⋅ T I FB = 70 µ A ⎩
This linear dependence has a value at zero load of 0.80·T and at maximum current of 0.40·T typical and results in two different behaviors of the device: Figure 9. TON Limited Operation
VOUT 0.80·VIN VOUT 0.80·VIN
T ON Limited Output characteristic
Resulting Output characteristic Desired Output characteristic and UVP threshold
0.40·VIN
0.40·VIN
IOCP=2·IOCPx (IDROOP=70µA)
IOUT
IOCP=2·IOCPx (IDROOP=70µA)
IOUT
a) Maximum output Voltage
b) TON Limited Output Voltage
TON Limited Output Voltage.
FOx
This happens when the maximum ON time is reached before the current in each phase reaches IOCPx (IIN< 35µA).
Figure 9a shows the maximum output voltage that the device is able to regulate considering the TON limitation imposed by the previous relationship. If the desired output characteristic crosses the TON limited maximum output voltage, the output resulting voltage will start to drop after crossing. In this case, the device doesn't perform constant current limitation but only limits the maximum duty cycle following the previous relationship. The output voltage follows the resulting characteristic (dotted in Figure 9b) until UVP is detected or anyway until IFB = 70µA. Constant Current Operation This happens when ON time limitation is reached after the current in each phase reaches IOCPx (IINFOx > 35µA). The device enters in Quasi-Constant-Current operation: the low-side mosfets stays ON until the current read becomes lower than IOCPx (IINFOx < 35µA) skipping clock cycles. The high side mosfets can be turned ON with a TON imposed by the control loop at the next available clock cycle and the device works in the
13/29
L6712A L6712
usual way until another OCP event is detected. This means that the average current delivered can slightly increase also in Over Current condition since the current ripple increases. In fact, the ON time increases due to the OFF time rise because of the current has to reach the IOCPx bottom. The worst-case condition is when the ON time reaches its maximum value. When this happens, the device works in Constant Current and the output voltage decrease as the load increase. Crossing the UVP threshold causes the device to reset. Figure 10 shows this working condition. It can be observed that the peak current (Ipeak) is greater than the IOCPx but it can be determined as follow: V IN – Vout min V IN – Vout MIN I peak = I OCPx + ------------------------------------- ⋅ Ton MAX = I OCPx + -------------------------------------- ⋅ 0.40 ⋅ T L L Where VoutMIN is the minimum output voltage (VID-40% as follow). The device works in Constant-Current, and the output voltage decreases as the load increase, until the output voltage reaches the under-voltage threshold (VoutMIN). The maximum average current during the Constant-Current behavior results: Ipeak – I OCPx I MAX,TOT = 2 ⋅ I MAX = 2 ⋅ ⎛ I OCPx + ------------------------------------- ⎞ ⎝ ⎠ 2 In this particular situation, the switching frequency results reduced. The ON time is the maximum allowed (TonMAX) while the OFF time depends on the application: Ipeak – I OCPx T OFF = L ⋅ ------------------------------------V OUt Figure 10. Constant Current operation
Ipeak IMAX IOCPx
UVP Vout Droop effect
1 f = ----------------------------------------T ONmax + T OFF
TonMAX
TonMAX
(IDROOP=50µA)
Iout IMAX,TOT
2·IOCPx (IDROOP=70µA)
a) Maximum current for each phase
b) Output Characteristic
Over current is set anyway when IINFOx reaches 35µA (IFB=70µA). The full load value is only a convention to work with convenient values for IFB. Since the OCP intervention threshold is fixed, to modify the percentage with respect to the load value, it can be simply considered that, for example, to have on OCP threshold of 200%, this will correspond to IINFOx = 35µA (IFB = 70µA). The full load current will then correspond to IINFOx = 17.5µA (IFB = 35µA). Once the UVP threshold has been intercepted, the device resets with all power mosfets turned OFF. Another soft start is then performed allowing the device to recover from OCP once the over load cause has been removed. Crossing the UVP threshold causes the device to reset: all mosfets are turned off and a new soft start is
14/29
L6712A L6712
then implemented allowing the device to recover if the over load cause has been removed.
■ L6712A - Fixed Maximum Duty Cycle Limitation The maximum duty cycle is fixed and constant with the delivered current. The device works in constant current operation once the OCP threshold has overcome. Refer to the above Constant Current section in which only the different value in the maximum duty has to be considered as follow:
V IN – Vout min V IN – Vout MIN I peak = I OCPx + ------------------------------------- ⋅ Ton MAX = I OCPx + -------------------------------------- ⋅ 0.85 ⋅ T L L All the above reported relationships about the deliverable current once in quasi-constant current and constant current are still valid in this case. 3.5 REMOTE SENSE AMPLIFIER Remote Sense Amplifier is integrated in order to recover from losses across PCB traces and wiring in high current DC/DC converter remote sense of the regulated voltage is required to maintain precision in the regulation. The integrated amplifier is a low-offset error amplifier; external resistors are needed as shown in Figure 11 to implement a differential remote sense amplifier. Figure 11. Remote Sense Amplifier Connections
Reference
Reference ERROR AMPLIFIER
REMOTE AMPLIFIER
ERROR AMPLIFIER
IDROOP
REMOTE AMPLIFIER
IDROOP
FBR FBG
VSEN
DROOP
FB
COMP
FBR FBG
VSEN
DROOP
FB
COMP
R2 R1
Remote VOUT
R2 R1
Remote Ground
RFB
CF
RF
RFB
CF
RF
VOUT
RB used
RB Not Used
Equal resistors give to the resulting amplifier a unity gain: the programmed reference will be regulated across the remote load. To regulate output voltages different from the available references, the Remote Amplifier gain can be adjusted simply changing the value of the external resistors as follow (see Figure 11): V VSEN RA_Gain = ---------------------------------------------------------------------------------------- = R2 ------Remote_V OUT – Remote_GND R1 to regulate a voltage double of the reference, the above reported gain must be equal to ½. Modifying the Remote Amplifier Gain (in particular with values higher than 1) allows also to regulate voltages lower than the programmed reference. Since this Amplifier is connected as a differential amplifier, when calculating the offset introduced in the regulated output voltage, the "native" offset of the amplifier must be multiplied by the term KOS = [1+(1/RA_Gain)] because a voltage generator insisting on the non-inverting input represents the offset. If remote sense is not required, it is enough connecting RFB directly to the regulated voltage: VSEN becomes not connected and still senses the output voltage through the remote amplifier. In this case the use of the external resistors R1 and R2 becomes optional and the Remote Sense Amplifier can simply be connected as a "buffer" to keep VSEN at the regulated voltage (See Figure 11). Avoiding use of Remote Amplifier saves its offset in the accuracy calculation but doesn't allow remote sensing.
15/29
L6712A L6712
3.6 INTEGRATED DROOP FUNCTION (Optional) Droop function realizes dependence between the regulated voltage and the delivered current (Load Regulation). In this way, a part of the drop due to the output capacitor ESR in the load transient is recovered. As shown in Figure 12, the ESR drop is present in any case, but using the droop function the total deviation of the output voltage is minimized. Connecting DROOP pin and FB pin together, forces a current IDROOP, proportional to the output current, into the feedback resistor RFB implementing the load regulation dependence. If RA_Gain is the Remote Amplifier gain, the Output Characteristic is then given by the following relationship (when droop enabled): R SENSE 1 1 V OUT = ------------------------ ⋅ ( VID – R FB ⋅ I DROOP ) = ------------------------ ⋅ ⎛ VID – R FB ⋅ --------------------- ⋅ I OUT⎞ ⎠ RA_Gain ⎝ RA_Gain Rg with a remote amplifier gain of 1/2, the regulated output voltage results in being doubled. The Droop current is equal to 50µA at nominal full load and 70µA at the OC intervention threshold, so the maximum output voltage deviation is equal to:
1 ∆ V FULL – POSITIVE – LOAD = – ------------------------ ⋅ R ⋅ 50 µ A RA_Gain FB 1 ∆ V OC – INTERVENTION = – ------------------------ ⋅ R ⋅ 70 µ A RA_Gain FB
Droop function is provided only for positive load; if negative load is applied, and then IINFOx