L9820
®
HIGH SIDE DRIVER
OPERATING SUPPLY VOLTAGE UP TO 25V
DC CURRENT 0.3A
RON < 800mΩ
DIAGNOSTIC AND PROTECTION FUNCTIONS
µP COMPATIBLE
ENABLE INPUT FOR STAND-BY MODE
DESCRIPTION
The L9820 High Side Driver realized with Multipower - BCD mixed technology, drives resistive
or inductive loads with one side connected to
ground.
The ENABLE input is TTL compatible and a diagnostic output provides an indication of short circuit
and device status (thermal and overvoltage shutdown). Onchip thermal protection and short circuit
protection are provided.
MULTIPOWER BCD TECHNOLOGY
Minidip
SO8
ORDERING NUMBERS:
L9820
L9820D
BLOCK DIAGRAM
40mΩ
September 2013
1/6
L9820
ABSOLUTE MAXIMUM RATINGS
Symbol
Parameter
Value
Unit
50
Vdc
Reverse Bias Current at -1.3V
Input Voltage (to GND)
–0.46
–0.3 to 20
A
V
Diag. Output Voltage (to GND)
Output Voltage (to GND)
–0.3 to 20
–0.3 to 25
V
V
VS
Max Forward Voltage
IR
V5
V8
V1
I4
I5
Supply Current
Enable Input Current
0.5
mA
I8
I1
Diag. Out Current (sink)
10
mA
Output Current
Operation Temperature
Internally limited
–40 to 85
°C
–55 to 150
°C
150
°C
Top
Tj, Tstg
Internally limited
Junction and Storage Temperature Range
Detecting Temperature
Tjp
PIN CONNECTION (Top views)
Minidip
SO8
THERMAL DATA
Symbol
Parameter
Rth j-amb
Thermal Resistance Junction-ambient
Max.
Minidip
SO8
Unit
100
200
°C/W
TRUTH TABLE
H: high level
L: low level
2/6
ENABLE
FUNCTION
DIAG. STATUS
POWER STATUS
L
H
H
Operating OFF
Normal Operation
Overvoltage Protection ON
H
H
L
L
H
L
H
H
Overcurrent Protection ON
Overtemperature
Protection ON
L
L
L
L
L9820
PIN FUNCTIONS
N.
Name
1
POWER OUTPUT
4
POWER SUPPLY
5
ENABLE INPUT
7
GROUND
8
DIAGNOSTIC FEEDBACK
Description
The device is provided with short circuit protection.
Supply voltage input.
TTL compatible input. High level on this pin means output current ON.
The low level voltage switches off the charge pump, the power stage and
the diagnostic output reducing to the minimum value the quiescent current.
This pin must be connected to ground.
The diagnostic circuit is active in input high level condition. This output
detects with Tipically 50µs delay at Tamb = 25°C the following faults:
– Overvoltage condition.
– Thermal shutdown.
– Short circuit. The power stage current is internally limited at 1.5A.
The diagnostic output is active low. The diagnostic delay time allows to
avoid spurious diagnosys(i.e.: turn ON overcurrent, overvoltage spikes etc.).
ELECTRICAL CHARACTERISTICS (VS = 14.4V, –40°C≤ Tj ≤ +85°C, unless otherwise specified.)
Symbol
Parameter
VS
Ron
Operating Supply Voltage
On Resistance
Ioff
Off State Supply Current
Ion
VEL
On State Supply Current
VEH
IE
Ileakd
Vsatd
Enable High Level
Enable Current
Diagnostic Output Leakage Current
Test Condition
Min.
Typ.
Max.
Unit
0.6
25
0.8
1.2
V
Ω
Ω
130
300
4
µA
µA
mA
6
Input > 2V, Tj = 25°C
Input > 2V, Full T range
Tj < 35°C
Tj = 85°C
Enable Low Level
0.8
V
0V < Vi
很抱歉,暂时无法提供与“L9820D”相匹配的价格&库存,您可以联系我们找货