Silicon Pressure Sensors
Ultra Low Pressure Sensing
DC Series
FEATURES
• Ultra Low Pressure
Sensing, down to
2.5 mBar
• ASIC Technology
• Available in Gage and
Differential Pressure
Ranges
• Available in Ratiometric
and Regulated
• Temperature Compensated
over 0 °C to 50°C
[32 °F to 122 °F]
• Combined Linearity and
Hysteresis error < ±0.25 %
Span
TYPICAL APPLICATIONS
• Medical Instrumentation
• HVAC
• Environmental Controls
• Portable Monitors
GENERAL DESCRIPTION
The DC Series pressure sensors combine SURSENSE™ precision high
sensitivity silicon sensing capabilities with the latest in Application Specific
Integrated Circuitry ASIC technology to produce one of the most precise,
reliable pressure sensors in the market. The SURSENSE technology
provides Dynamic Self Compensation which substantially reduces offset
errors due to changes in temperature, stability to warm up, long term
instability and position sensitivity.
When operated with an unregulated 7.0 Vdc to 16.0 Vdc supply the DC
sensors provides a ratiometric 0.50 to 4.50 Vdc output (4.0 Vdc span).
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
WARNING
MISUSE OF DOCUMENTATION
• The information presented in this product sheet is for reference only.
Do not use this document as a product installation guide.
• Complete installation, operation, and maintenance information is
provided in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Silicon Pressure Sensors
Ultra Low Pressure Sensing
DC Series
ELECTRICAL SPECIFICATIONS
Ouput
C4 Ratiometric
R4 Regulated
R5 Regulated
Pressure
Reference
Excitation
(Vdc)
Offset(1)
Voltage (Vdc)
Output Span
(Vdc)
Supply
Current (max.)
Output
Source
Current (max.)
Output Sink
Current @
null (max.)
Gage
5 ±0.1
0.25
4
4 mA
2.0 mA
20 μA
Differential
5 ±0.1
2.25
±2
4 mA
2.0 mA
20 μA
Gage
7 to 16
0.25
4
8 mA
2.0 mA
20 μA
Differential
7 to 16
2.25
±2
8 mA
2.0 mA
20 μA
Gage
7 to 16
0.25
5
8 mA
2.0 mA
20 μA
Differential
7 to 16
3.5
±2.5
8 mA
2.0 mA
20 μA
PERFORMANCE SPECIFICATIONS(2)
Pressure
Ranges
±0.5 in H2O
1 in H2O
2.5 mBar
2 in H2O
5 mBar
2.5 in H2O
5 in H2O
10 mBar
10 in H2O
25 mBar
20 in H2O
50 mBar
30 in H2O
75 mBar
140 cm H2O
Overpressure
100 in H2O
100 in H2O
250 mBar
100 in H2O
250 mBar
100 in H2O
150 in H2O
375 mBar
150 in H2O
375 mBar
300 in H2O
750 mBar
450 in H2O
1125 mBar
1125 cm H2O
Offset
Position
Sensitivity
±10 mV
±10 mV
±10 mV
±10 mV
±10 mV
±10 mV
±5 mV
±5 mV
±1 mV
±1 mV
±1 mV
±1 mV
±1 mV
±1 mV
±1 mV
Total Error
(Typical)
Total Error(3)
(Max.)
Accuracy(4)
±2.0 %
±2.0 %
±2.0 %
±1.5 %
±1.5 %
±1.5 %
±1.0 %
±1.0 %
±1.0 %
±1.0 %
±1.0 %
±1.0 %
±1.0 %
±1.0 %
±1.0 %
±3.0 %
±3.0 %
±3.0 %
±2.5 %
±2.5 %
±2.5 %
±2.0 %
±2.0 %
±2.0 %
±2.0 %
±2.0 %
±2.0 %
±2.0 %
±2.0 %
±2.0 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
±0.25 %
Note 1: Offset voltage and output span are nominal
Note 2: All specifications are relative to readings taken at 25 °C [77 °F] and at rated excitation unless otherwise specified.
Note 3: Percentage of Full Scale Includes: zero calibration, span calibration, temperature effect on zero and span, nonlinearity, hysteresis, repeatability and stability over the compensated temperature range.
Note 4: Percentage of Best Fit Straight Line Includes: non-linearity, hysteresis, and repeatability.
Material in Contact with Media
Compensated Temperature Range
Operating Temperature Range
Storage Temperature
Silicon diaphragm, glass filled nylon, silicone, and alumina
ceramic.
0 °C to 50 °C [32 °F to 170 °F]
-25 °C to 85 °C [-13 °F to 185 °F]
-40 °C to 125 °C [-40 °F to 257 °F]
2 Honeywell • Sensing and Control
Silicon Pressure Sensors
Ultra Low Pressure Sensing
DC Series
PHYSICAL DIMENSIONS for reference only mm [In]
Note: For gage sensor apply pressure to port 2.
Pin
Number
1
2
3
4
C4
0.25 Vdc to 4.25
Vdc Ratiometric
V Excitation
Common
V out
Not for
Customer Use
DC Electrical Output Version
R4
R5
0.25 Vdc to 4.25 Vdc
1.0 Vdc to 6.0 Vdc
Regulated
Regulated
V Excitation
V Excitation
Common
Common
V out
V out
Not for
Not for
Customer Use
Customer Use
Honeywell • Sensing and Control 3
Silicon Pressure Sensors
Ultra Low Pressure Sensing
DC Series
DC SERIES ORDER GUIDE
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are
returned to Honeywell during the period of coverage,
Honeywell will repair or replace without charge those
items it finds defective. The foregoing is Buyer’s
sole remedy and is in lieu of all other warranties,
expressed or implied, including those of
merchantability and fitness for a particular
purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and
reliable as of this printing. However, we assume no
responsibility for its use.
While we provide application assistance personally,
through our literature and the Honeywell web site, it
is up to the customer to determine the suitability of
the product in the application.
For application assistance, current specifications, or
name of the nearest Authorized Distributor, contact a
nearby sales office. Or call:
1-800-537-6945 USA/Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com
Sensing and Control
Honeywell
1985 Douglas Drive North
Golden Valley, MN 55422
www.honeywell.com
008134-2-EN IL50 GLO Printed in USA
April 2009
© 2009 Honeywell International Inc.
很抱歉,暂时无法提供与“DC010NGC4”相匹配的价格&库存,您可以联系我们找货