1 Form A 5A
slim power relay
complies with IEC61010
reinforced insulation
New
RoHS compliant
Protective construction: Sealed type
(RTIII)
PA-N RELAYS
FEATURES
TYPICAL APPLICATIONS
1. High density mounting
5mm(W) × 20mm(L) × 12.5mm(H)
.197inch(W) × .787inch(L) ×
.492inch(H)
2. Low operating power
Nominal operating power: 110mW
3. Complies with IEC61010 reinforced
insulation standards
4. Long Insulation distance
• Clearance: 5.29mm .208inch
Creepage distance: 5.35mm .211inch
(Between contact and coil)
• 3,000 V breakdown voltage and
6,000V surge breakdown voltage
5. Complies with Standard for
Hazardous Location (ANSI/ISA
12.12.01)
1. Output relays for programmable
controllers and temperature
controllers
2. Industrial equipment, office
equipment
3. Measuring devices and test
equipment
ORDERING INFORMATION
APAN 3
1
Contact arrangement
3: 1 Form A (Bifurcated)
Terminals and Nominal operating power
1: PC board terminal (110 mW)
Nominal coil voltage (DC)
03: 3V, 4H: 4.5V, 05: 5V, 06: 6V, 09: 9V, 12: 12V, 18: 18V, 24: 24V
Note: Certified by UL/C-UL and TÜV
TYPES
Contact arrangement
1 Form A
Nominal coil voltage
3 V DC
4.5 V DC
5 V DC
6 V DC
9 V DC
12 V DC
18 V DC
24 V DC
Part No.
APAN3103
APAN314H
APAN3105
APAN3106
APAN3109
APAN3112
APAN3118
APAN3124
Standard packing: Tube: 25 pcs.; Case: 1,000 pcs.
* Terminal sockets available.
–1–
ASCTB368E 201604-T
PA-N (APAN3)
RATING
1. Coil data
Nominal coil
voltage
3 V DC
4.5 V DC
5 V DC
6 V DC
9 V DC
12 V DC
18 V DC
24 V DC
Pick-up voltage
(at 20°C 68°F)
70%V or less of
nominal voltage*
(Initial)
Drop-out voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
5%V or more of
nominal voltage*
(Initial)
36.7 mA
24.4 mA
22.0 mA
18.3 mA
12.2 mA
9.2 mA
6.1 mA
4.6 mA
82 Ω
184 Ω
227 Ω
327 Ω
736 Ω
1,309 Ω
2,945 Ω
5,236 Ω
110mW
120%V of
nominal voltage
Note: *Pulse drive (JIS C 5442)
2. Specifications
Characteristics
Contact
Rating
Electrical
characteristics
Mechanical
characteristics
Expected life
Conditions
Item
Arrangement
Contact resistance (Initial)
Contact material
Nominal switching capacity (resistive load)
Max. switching power (resistive load)
Max. switching voltage
Max. switching current
Nominal operating power
Min. switching capacity (Reference value)*1
Insulation resistance (Initial)
Breakdown voltage Between open contacts
(Initial)
Between contact and coil
Surge breakdown voltage (Initial)
(Between contacts and coil)*2
Operate time (at nominal voltage) (at 20°C 68°F)
(Initial)
Release time (at nominal voltage) (at 20°C 68°F)
(Initial)
Functional
Shock resistance
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Electrical
Conditions for operation, transport and storage*3
Max. operating speed
Unit weight
Specifications
1 Form A (Bifurcated)
Max. 30 mΩ (By voltage drop 6 V DC 1A)
AgNi type + Au
5 A 250 V AC, 5 A 30 V DC
1,250 VA, 150 W
250 V (AC), 110 V (DC) (0.4 A)
5 A (AC, DC)
110 mW
1 mA 5 V DC
Min. 1,000MΩ (at 500V DC) Measurement at same location as “Breakdown voltage” section.
1,000 Vrms for 1min. (Detection current: 10mA.)
3,000 Vrms for 1min. (Detection current: 10mA.)
6,000 V
Max. 10 ms (excluding contact bounce time)
Max. 5 ms (excluding contact bounce time and without diode)
Min. 147 m/s2 (Half-wave pulse of sine wave: 11 ms; detection time: 10μs.)
Min. 980 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 2.5 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 3.5 mm
Min. 2×107 (at 180 times/min.)
Min. 105 (3 A 250 V AC, 30 V DC, resistive load)
Min. 5×104 (5 A 250 V AC, 30 V DC, resistive load) (at 20 times/min.)*4
Ambient temperature: –40°C to 90°C –40°F to 194°F;
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 times/min. (at nominal switching capacity)*4
Approx. 3 g .15 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of ±1.2×50μs according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, transport and storage
conditions in NOTES.
*4. Operating frequency of 5 A 250 V AC is 6 times/min. (ON : OFF = 1 s : 9 s)
–2–
ASCTB368E 201604-T
PA-N (APAN3)
REFERENCE DATA
1. Max. switching capacity
2. Life curve
3. Coil temperature rise
Tested sample: APAN3124, 6 pcs.
Measured portion: Inside the coil
Ambient temperature: 20°C 68°F, 90°C 194°F (No
contact current)
AC250V resistive load
DC30V resistive load
DC30V L/R=7ms
AC resistive load
No. of operations, ×104
Contact current, A
5
100
DC resistive load
1
0.4
50
40
30
AC250V cosφ =0.4
20
10
5
40
35
Temperature rise, °C
10
30
25
5A (20°C)
3A (20°C)
0A (20°C)
20
15
0A (90°C)
10
5
0.1
1
10
100
Contact voltage, V
1
0.1
1000
0.5
1
3
5
Switching capacity, A
10
0
90
100
110 120 130 140
Coil applied voltage, %V
4. Operate & release time
5. Ambient temperature characteristics
6. Malfunctional shock
Tested sample: APAN3124, 20 pcs.
Measured direction: Upright
Tested sample: APAN3124, 6 pcs.
Tested sample: APAN3124, 6 pcs.
30
Rate of
change, %
Operate & release time, ms
10.0
9.0
8.0
1000
Drop-out voltage
20
600
Pick-up voltage
6.0
-60 -40 -20
Max.
Ave.
Min.
4.0
3.0
0
0
Z
400
10
Operate time
Deenergized
condition
Energized
condition
Y
800
X
7.0
5.0
150
200
0
20 40
-10
60 80 100
Ambient
temperature, °C
Z’
X’
Z’ Y’
Y
Release time
1.0
0.0
70
80
Z
Max.
Ave.
Min.
90
100 110
120
Coil applied voltage, %V
-20
X
Y’
DIMENSIONS (mm inch)
The CAD data of the products with a
CAD Data
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
External dimensions
CAD Data
PC board pattern (Bottom view)
1.2 dia.
.047 dia.
1.2 dia.
.047 dia.
1.3
.051
0.5
.020
1.2
.047
2.9
.114
3.5
.138
6
.236
4.8
.189
8.8
.346
X’
-30
130
12.5
(12.8 Max.)
.492
(.504 Max.)
2.0
5.0
.197
2.54
.100
0.5
.020
10.16
.400
20
.787
5.08
.200
0.8
.031
1.1
.043
1.2
.047
0.25
.010
1 dia.
.039 dia.
1 dia.
.039 dia.
2.54
.100
10.16
.400
5.08
.200
Tolerance: ±0.1 ±.004
Schematic (Bottom view)
General tolerance: ±0.3 ±.012
1 2
5
6
NO COM
Coil
–3–
ASCTB368E 201604-T
PA-N (APAN3)
SAFETY STANDARDS
UL/C-UL (Recognized)
Contact ratings
Temp.
5 A 250 V AC Resistive
40°C 104°F
5 A 250 V AC Resistive
90°C 194°F
5 A 30 V DC General use
40°C 104°F
5 A 30V DC, 3 A 250 V AC General use
90°C 194°F
3 A 250 V AC Resistive
40°C 104°F
3 A 30 V DC General use
40°C 104°F
B300, R300 Pilot duty
40°C 104°F
E479891 Class I, Division 2, Groups A, B, C, D Hazardous Location
(ANSI/ISA 12.12.01-2015, CAN/CSA C22.2 No.213-15)
File No.
E43149
TÜV (Certified)
Contact ratings
B16 01 13461 348 5 A 250 V AC (cosφ =1.0)
5 A 250 V AC (cosφ =1.0)
5 A 30 V DC (0 ms)
5 A 30 V DC (0 ms)
3 A 250 V AC (cosφ =1.0)
3 A 30 V DC (0 ms)
Cycles
File No.
5×104
104
5×104
104
105
105
—
Temp.
Cycles
40°C 104°F
90°C 194°F
40°C 104°F
90°C 194°F
40°C 104°F
40°C 104°F
5×104
104
5×104
104
105
105
Insulation distance (between contact and coil)
• UL/C-UL: Clearance distance: 5.29 mm .208 inch, Creepage distance: 5.35 mm .211 inch
• TÜV: Clearance distance: 5.29 mm .208 inch, Creepage distance: 5.35 mm .211 inch
NOTES
1. For cautions for use, please read
“GENERAL APPLICATION
GUIDELINES”.
2. If it includes ripple, the ripple factor
should be less than 5%.
3. Specification values for pick-up and
drop-out voltages are for the relay
mounting with its terminals below.
4. When mounting the relays within
1 mm .039 inch, please notice the
condition below.
1) Mount the relays in the same
direction.
Within 1 mm
.039 inch
Tested sample: APAN3124, 6 pcs.
Ambient temperature: 20°C 68°F
Measured direction: 6 direction
100
90
80
Voltage, %V
70
Pick-up voltage
Max.
Ave.
Min.
60
50
2) Coil terminals (Terminal No. 1 & 2)
polarity should be arranged in the
same direction.
40
30
20
Drop-out voltage
Max.
Ave.
Min.
10
0
Mounting
direction
–.
+.
–.
+.
–.
+.
–.
+.
–.
+.
–4–
+.
–.
+.
–.
+.
–.
+.
–.
+.
–.
ASCTB368E 201604-T