449
40 mm Beam Pitch General Purpose Area Sensor
NA40 SERIES
Related Information
FIBER
SENSORS
■■General terms and conditions.............. F-3
■■Glossary of terms / General precautions.......P.1549~ / P.1552~
■■Selection guide.............................. P.419~
■■Korea’s S-mark............................... P.1602
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Certified
(NA40-□-K only)
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Make sure to use safety
light curtains when using
a sensing device for
personnel protection.
Refer to p.455~ for details
of safety light curtains.
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Diagnosis
panasonic.net/id/pidsx/global
MEASUREMENT
SENSORS
Self-diagnosis Interference
prevention
STATIC
CONTROL
DEVICES
LASER
MARKERS
Slim and smart
PLC
ORDER GUIDE
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
Sensors Mating cable is not supplied with the sensor. Please order it separately.
Type
MACHINE VISION
SYSTEMS
Appearance
Sensing range
Beam channel No.
n
UV CURING
SYSTEMS
Sensing height
Selection
Guide
Slim Body
1
Picking
0.5 m
1.640 ft
NA40-6
6
200 7.874
NA40-8
8
280 11.024
NA40-10
10
360 14.173
NA40-14
14
520 20.472
40 mm
1.575 in
NA40-16
16
600 23.622
NA40-20
20
760 29.921
NA40-24
24
920 36.221
NA40-4-H
4
120 4.724
NA40-6-H
6
200 7.874
NA40-8-H
8
280 11.024
NA40-10-H
10
360 14.173
NA40-12-H
12
440 17.323
Beam pitch
NA40-14-H
14
520 20.472
40 mm
1.575 in
NA40-16-H
16
600 23.622
NA40-20-H
20
760 29.921
NA40-24-H
24
920 36.221
5m
16.404 ft
Sensing height
3
0.5 m
1.640 ft
120 4.724
440 17.323
n
1
4
12
Beam channel No.
2
NA40-4
NA40-12
Optional mating cable
With spatter protection hood
NA40
Area sensor
Other Products
Number of
Sensing
beam channels height (mm in)
Beam pitch
3
2
Model No.
Optional mating cable
Note: The model No. with “P” shown on the label affixed to the product is the emitter, “D” shown on the label is the receiver.
Output
NPN
open-collector
transistor
40 mm Beam Pitch General Purpose Area Sensor
NA40 SERIES
ORDER GUIDE
FIBER
SENSORS
LASER
SENSORS
Products that obtained Korea’s S-mark certification
We offer products that have obtained Korea’s S-mark certification (excluding the sensors with spatter protection hood).
When ordering this type, suffix “-K” to the model No.
(e.g.) NA40-4 with Korea’s S-mark certification is “NA40-4-K”.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Mating cables Mating cable is not supplied with the sensor. Please order it separately.
Appearance
450
AREA
SENSORS
Model No.
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Description
NA40-CC3
Length: 3 m 9.843 ft
Net weight: 6
00 g approx.
(two cables)
NA40-CC7
Length: 7 m 22.966 ft
Net weight: 9
50 g approx.
(two cables)
0.5 mm2 3-core (for receiver: 4-core) cabtyre cable with
connector on one end, two cables per set.
Cable outer diameter: ø6.7 mm ø0.264 in
Connector outer diameter: ø14 mm ø0.551 in max.
Cable color: Gray (for emitter)
Black (for receiver)
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
Accessory
SIMPLE
WIRE-SAVING
UNITS
Four bracket set
Four M5 (length 40 mm 1.575 in)
truss head screws, four nuts and
four spring washers are attached.
• MS-NA40-1 (Sensor mounting bracket)
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
Individual units and associated components can be purchased separately
Designation
Number of
beam channels
Main unit
4
Sub-unit
4
2
End unit
End cap (Note)
4
–
• NA40-4
Model No.
Emitter
Receiver
NA40-MUP
NA40-4SUP
NA40-2EUP
NA40-4EUP
NA40-ECP
NA40-MUD
NA40-4SUD
NA40-2EUD
NA40-4EUD
NA40-ECD
• NA40-10
Front cover
Cover stopper
attached to
protection enclosure
Cover stopper
(attached to protection enclosure)
End unit
(2 beam channels)
End cap
Protection
enclosure
Protection
enclosure
Sub-unit
MACHINE
VISION
SYSTEMS
Main unit
UV
CURING
SYSTEMS
Front cover
Protection
enclosure
With spatter
protection
hood
Front cover
6 beam
channels
8 beam
channels
10 beam
channels
12 beam
channels
14 beam
channels
16 beam
channels
20 beam
channels
24 beam
channels
Model No.
MC-NA40-4 MC-NA40-6 MC-NA40-8 MC-NA40-10 MC-NA40-12 MC-NA40-14 MC-NA40-16 MC-NA40-20 MC-NA40-24
Model No.
MC-NA40-4H MC-NA40-6H MC-NA40-8H MC-NA40-10H MC-NA40-12H MC-NA40-14H MC-NA40-16H MC-NA40-20H MC-NA40-24H
Model No.
FC-NA40-4 FC-NA40-6 FC-NA40-8 FC-NA40-10 FC-NA40-12 FC-NA40-14 FC-NA40-16 FC-NA40-20 FC-NA40-24
OPTIONS
Slit mask
4 beam
channels
6 beam
channels
8 beam
channels
Selection
Guide
Slim
Body
Picking
Other
Products
NA40
Note: The model Nos. given above denote a single unit, not a pair of units.
Applicable beam
channels
Designation
HUMAN
MACHINE
INTERFACES
FA
COMPONENTS
Main unit
4 beam
channels
PLC
ENERGY
MANAGEMENT
SOLUTIONS
Note: It is required only for NA40-4 or NA40-4-H.
Applicable beam
channels
Designation
LASER
MARKERS
10 beam
channels
12 beam
channels
14 beam
channels
16 beam
channels
20 beam
channels
24 beam
channels
Model No. OS-NA40-4 OS-NA40-6 OS-NA40-8 OS-NA40-10 OS-NA40-12 OS-NA40-14 OS-NA40-16 OS-NA40-20 OS-NA40-24
Note: The model Nos. given above denote a single unit, not a pair of units.
Slit mask
• OS-NA40-□
Sensing range
• Slit on emitter side: 1.3 m 4.265 ft
• Slit on receiver side: 3 m 9.843 ft
• Slit on both sides: 0.8 m 2.625 ft
451
40 mm Beam Pitch General Purpose Area Sensor
NA40 SERIES
OPTIONS
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Designation
Model No.
Large indicator
for area sensor
Large indicator for area sensor
Description
• SF-IND
The large indicator can
be easily mounted on the
sensor head at the top. It
also can be mounted on an
area sensor already being
used.
With the large indicators put on the sensors, the operation is
easily observable from various directions. Orange.
SF-IND
Note: Two SF-INDs are required if they are to be mounted on, both, the emitter and the receiver.
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
SPECIFICATIONS
INDUCTIVE
PROXIMITY
SENSORS
Number of beam
channels
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Model No.
Item
With spatter
protection hood
Sensing height
4
6
24
NA40-8
NA40-10
NA40-12
NA40-14
NA40-16
NA40-20
NA40-24
NA40-4
NA40-6
NA40-6-H
120 mm 4.724 in
200 mm 7.874 in 280 mm 11.024 in 360 mm 14.173 in 440 mm 17.323 in 520 mm 20.472 in 600 mm 23.622 in 760 mm 29.921 in 920 mm 36.220 in
NA40-8-H NA40-10-H NA40-12-H NA40-14-H NA40-16-H NA40-20-H NA40-24-H
5 m 16.404 ft
40 mm 1.575 in
Supply voltage
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Current consumption
Emitter: 30 mA or less
Receiver: 60 mA or less
Emitter: 35 mA or less, Receiver: 90 mA or less
Output operation
ON when all beam channels are received / OFF when one or more beam channels are interrupted
Short-circuit protection
Incorporated
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less (between self-diagnosis output and 0 V)
• Residual voltage: 1.6 V or less (at 50 mA sink current)
Self-diagnosis output
Output operation
OFF when unstable light received condition continues for 5 sec. or more, or the output transistor fails
Short-circuit protection
Incorporated
Response time
12 ms or less
Incorporated with the three color indicators on the receiver
• Sensing output operation indicator: Red LED (lights up when one or more beam channels are interrupted)
• Stable incident beam indicator: Green LED (lights up when all beam channels are received stably)
• Unstable incident beam indicator: Yellow LED (lights up when one or more beam channels are received unstably)
* When the output transistor fails, the three color indicators blink simultaneously.
Interference prevention function
Incorporated (Two units of sensors can be mounted close together.)
Protection
Environmental resistance
Ambient temperature
Emitter: 35 mA or less
Receiver: 115 mA or less
NPN open-collector transistor
• Maximum sink current: 100 mA
• Applied voltage: 30 V DC or less (between sensing output and 0 V)
• Residual voltage: 1.6 V or less (at 100 mA sink current)
Sensing output
Picking
NA40
20
ø60 mm ø2.362 in or more opaque object
Indicator
Other
Products
16
Sensing object
MACHINE
VISION
SYSTEMS
Slim
Body
14
Beam pitch
ENERGY
MANAGEMENT
SOLUTIONS
Selection
Guide
12
Sensing range
HUMAN
MACHINE
INTERFACES
UV
CURING
SYSTEMS
10
NA40-4-H
PLC
FA
COMPONENTS
8
IP65 (IEC)
–10 to +50 °C +14 to +122 °F (No dew condensation or icing allowed), Storage: –10 to +60 °C +14 to +140 °F
Ambient humidity
35 to 85 % RH, Storage: 35 to 85 % RH
Ambient illuminance
Incandescent light: 3,500 ℓx or less at the light-receiving face
Voltage withstandability
1,000 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
20 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 55 Hz frequency, 1.5 mm 0.059 in double amplitude in X, Y and Z directions for two hours each
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Shock resistance
Infrared LED (synchronized scanning system)
Emitting element
Protection enclosure: Aluminum, Unit case: ABS, Front cover: Acrylic, Lens: Acrylic
Material
Cable
Cable extension
0.5 mm2 4-core (emitter: 3-core) cabtyre cable, 0.5 m 1.640 ft long, with a round connector at the end
* Use together with the optional mating cable
Extension up to total 100 m 328.084 ft is possible, for both emitter and receiver, with 0.5 mm 2, or more, cable.
(However, the interference prevention wire can extend up to 20 m 65.617 ft between two emitters.)
Net weight (Total of emitter and receiver) 400 g approx. 500 g approx.
With spatter protection hood 500 g approx.
Accessories
630 g approx.
630 g approx.
770 g approx.
890 g approx. 1,020 g approx. 1,150 g approx. 1,400 g approx. 1,660 g approx.
800 g approx.
990 g approx. 1,150 g approx. 1,330 g approx. 1,500 g approx. 1,840 g approx. 2,190 g approx.
MS-NA40-1 (Sensor mounting bracket): 1 set for emitter and receiver, Adjusting screwdriver: 1 pc.
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F.
40 mm Beam Pitch General Purpose Area Sensor
NA40 SERIES
452
I/O CIRCUIT DIAGRAMS
FIBER
SENSORS
LASER
SENSORS
I/O circuit diagrams
Receiver
Connector pin No.
Color code
Sensor circuit
D
①
(Brown) +V
③
(Blue) 0 V
12 to 24 V DC
±10 %
(Orange/Violet)
② Interference
prevention wire
(Notes 1, 2)
Internal circuit
①
④
Tr 1
ZD2
②
12 to 24 V DC
±10 %
(Blue) 0 V
Internal circuit
Symbols ... D: Reverse supply polarity protection diode
Load
Load
100 mA max.
(Orange) Self-diagnosis output (Note 2)
50 mA max.
Tr 2
③
Users’ circuit
MICRO
PHOTOELECTRIC
SENSORS
(Brown) +V
(Black)
Sensing output
ZD1
When using two sensors
side by side, connect these
wires of both the emitters
together.
PHOTOELECTRIC
SENSORS
Connector pin No.
Color code
D
Sensor circuit
Emitter
Users’ circuit
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Connector pin position
Emitter
Interference
prevention wire
(Orange/Violet)
0 V (Blue)
WIRE-SAVING
SYSTEMS
2
1
3
4
+V (Brown)
Receiver
Self-diagnosis
output (Orange)
NC
2
1
0 V (Blue) 3
4
PRECAUTIONS FOR PROPER USE
Receiver
Set the switches of both the
emitter and the receiver at ‘1’.
The sensor does not function
normally at other settings.
①Set the frequency selection switch.
Firstly, push up the front cover
while pressing the cover stopper
towards the arrow shown in the
right figure.
②Turn the frequency selection
switch with the accessory
adjusting screwdriver to select the
frequency.
Sensing Area B
Sensor B
Emitter
MACHINE
VISION
SYSTEMS
Sensor A
Front cover
Selection
Guide
Slim
Body
Picking
Other
Products
Set the switches of both the
emitter and the receiver of
Sensor A at ‘1’, and both
switches of Sensor B at ‘2’.
The sensors do not function
normally at other settings.
③Connect the interference prevention wire (INTER LOCK)
of Sensor A and B.
Emitter of
Sensor A Connect both interference
prevention wire (INTER LOCK)
Emitter of
Sensor B
UV
CURING
SYSTEMS
Cover stopper
Receiver
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
Sensing
Area A
Frequency selection switches
Frequency selection switches
LASER
MARKERS
HUMAN
MACHINE
INTERFACES
When using one set of sensor
STATIC
CONTROL
DEVICES
• Up to two sets of sensors can
be mounted close together
by using the interference
prevention function. Set the
interference prevention function
in the following procedure.
• When the interference prevention function is not used
(when one set of sensor is used) make sure that the
frequency selection switch in both the emitter and
receiver is set to ‘1’. If the switch is set to other than that,
the sensor may not operate properly.
Sensing output (Black)
PLC
• Make sure that the power supply is off while operating the
frequency selection switch. If the switch is operated while the
power is on, the sensor may go into the operation stopped
state. However, to restart the sensor, turn the power off and
on again.
• The frequency selection switch should not be set to the
positions other than those specified below.
• When the sensor A breaks down due to any reason, the
sensor B goes into the operation stopped state. In order
to check the operation of the sensor B, set the frequency
selection switch to ‘1’. Note that when only the sensor B
breaks down, the sensor A keeps operation correctly.
MEASUREMENT
SENSORS
When using two sets of sensor
Sensor A
Setting of interference prevention function
+V (Brown)
Refer to p.1552~ for general precautions.
Sensor B
• Never use this product as a sensing device for
personnel protection.
• For sensing devices to be used as safety devices
for press machines or forpersonnel protection,
use products which meet standards, such as
OSHA, ANSI or IEC etc., for personnel protection
applicable in each region or country.
• If this product is used as a sensing device for
personnel protection, death or serious body injury
could result.
• For a product which meets safety standards, use
the safety light curtains. (p.455~)
Emitter
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
Symbols ... D: Reverse supply polarity protection diode
ZD1, ZD2: Surge absorption zener diode
Tr1, Tr2 : NPN output transistor
Notes: 1) If the interference prevention wires (orange/violet) are not
used, please insulate them.
Notes: 2) Never connect the emitter’s interference prevention wire
(orange/violet) to the receiver’s self-diagnosis output (orange).
This can cause damage.
AREA
SENSORS
+V
0V
• Connect both the 0 V wires
in common.
• +V wires need not be
connected in common.
Note: T
otal of wire length between Sensor A and B is 20 m 65.617 ft max.
(Total of wire length of interference prevention wire and 0 V is 20 m
65.617 ft max.)
NA40
453
FIBER
SENSORS
LASER
SENSORS
40 mm Beam Pitch General Purpose Area Sensor
NA40 SERIES
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from our website.
NA40-□
Sensor
PHOTOELECTRIC
SENSORS
30
1.181
MICRO
PHOTOELECTRIC
SENSORS
25.5
1.004
17
0.669
2-ø5.5 ø0.217
mounting holes
8.5 0.335
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Front cover (replaceable)
(both emitter and receiver)
Sensing
height
PARTICULAR
USE
SENSORS
B
A
C
SENSOR
OPTIONS
Three color indicators
(Red, Green, Yellow)
SIMPLE
WIRE-SAVING
UNITS
Frequency selection switch
(both emitter and receiver)
WIRE-SAVING
SYSTEMS
Beam pitch
40 1.574
MEASUREMENT
SENSORS
25 0.984
STATIC
CONTROL
DEVICES
8.5 0.335
ø6.7 ø0.264 cable
0.5 m 1.642 ft
9 0.354
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
ø14
ø0.551
ø14
ø0.551
Emitter
Receiver
Model No.
A
B
C
NA40-4
120
4.724
163
6.417
180
7.087
NA40-6
200
7.874
233
9.173
250
9.843
NA40-8
280
11.024
313
12.323
330
12.992
NA40-10
360
14.173
393
15.472
410
16.142
NA40-12
440
17.323
473
18.622
490
19.291
NA40-14
520
20.472
553
21.772
570
22.441
NA40-16
600
23.622
633
24.921
650
25.591
NA40-20
760
29.921
793
31.220
810
31.890
NA40-24
920
36.220
953
37.520
970
38.189
NA40-□-H
Sensor
30
1.181
MACHINE
VISION
SYSTEMS
17
0.669
50
1.969
UV
CURING
SYSTEMS
2-ø5.5 ø0.217
mounting holes
8.5 0.335
Selection
Guide
Slim
Body
Front cover (replaceable)
(both emitter and receiver)
Picking
Other
Products
Sensing
height
Indicator
window
A
Indicator
window
Model No.
B
C
NA40
Three color indicators
(Red, Green, Yellow)
Frequency selection switch
(both emitter and receiver)
Beam pitch
40 1.574
25 0.984
8.5 0.335
9 0.354
ø6.7 ø0.264 cable
0.5 m 1.642 ft
ø14
ø0.551
Emitter
ø14
ø0.551
Receiver
A
B
C
NA40-4-H
120
4.724
163
6.417
180
7.087
NA40-6-H
200
7.874
233
9.173
250
9.843
NA40-8-H
280
11.024
313
12.323
330
12.992
NA40-10-H
360
14.173
393
15.472
410
16.142
NA40-12-H
440
17.323
473
18.622
490
19.291
NA40-14-H
520
20.472
553
21.772
570
22.441
NA40-16-H
600
23.622
633
24.921
650
25.591
NA40-20-H
760
29.921
793
31.220
810
31.890
NA40-24-H
920
36.220
953
37.520
970
38.189
40 mm Beam Pitch General Purpose Area Sensor
DIMENSIONS (Unit: mm in)
NA40 SERIES
454
The CAD data can be downloaded from our website.
MS-NA40-1
Sensor mounting bracket (Accessory)
Assembly dimensions
32 1.260
18 ±0.2 0.709 ±0.008
5.5
0.217
t2
9.5
0.374
31.5
1.240
23.5 0.925
19
16 0.748
0.630
25.5
1.004
Mounting drawing with NA40-□.
The assembly for the spatter protection hood type
(NA40-□-H) is similar.
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
(43)
(1.693)
18
0.709
ø5.5 ø0.217
(on both sides)
7
0.278
30.5
1.201
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
5.5
0.217
t2
Model No.
9.5 0.374
7
0.278
10
0.394
Sensing
height
6
0.236
A
(D)
(E)
Material: Cold rolled carbon steel (SPCC)
(Uni-chrome plated)
Four bracket set
4 pcs. each of M5 (length 40 mm 1.575 in )
truss head screws, nuts and spring
washers are attached.
Beam pitch
40
1.575
33.7 1.327
6.3 0.248
SF-IND
A
D
E
NA40-4(-H)
200
7.874
210
8.268
NA40-6(-H)
200
7.874
270
10.630
280
11.024
NA40-8(-H)
280
11.024
350
13.780
360
14.173
NA40-10(-H)
360
14.173
430
16.929
440
17.323
WIRE-SAVING
SYSTEMS
NA40-12(-H)
440
17.323
510
20.079
520
20.472
MEASUREMENT
SENSORS
NA40-14(-H)
520
20.472
590
23.228
600
23.622
STATIC
CONTROL
DEVICES
NA40-16(-H)
600
23.622
670
26.378
680
26.772
LASER
MARKERS
NA40-20(-H)
760
29.921
830
32.677
840
33.071
PLC
NA40-24(-H)
920
36.220
990
38.976
1,000
39.370
Assembly dimensions
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
Mounting drawing with NA40-□ on which a sensor
mounting bracket is attached.
The assembly for the spatter protection hood type
(NA40-□-H) is similar.
Orange LED
INDUCTIVE
PROXIMITY
SENSORS
120
4.724
Large indicator for area sensor (Optional)
27
1.063
LASER
SENSORS
PHOTOELECTRIC
SENSORS
27.5 1.083
19.5
0.768
FIBER
SENSORS
UV
CURING
SYSTEMS
(43)
(1.693)
27.5 (30)
1.083 (1.181)
Selection
Guide
Slim
Body
28
1.102
15
0.591
ø3.7 ø0.146 cable
2 m 6.562 ft
Sensor unit
joining part
28
1.102
Picking
Model No.
3.5
0.138
(E)(F)
E
F
NA40-4(-H)
210
8.268
223
8.780
NA40-6(-H)
280
11.024
293
11.535
NA40-8(-H)
360
14.173
373
14.685
NA40-10(-H)
440
17.323
453
17.835
NA40-12(-H)
520
20.472
533
20.984
NA40-14(-H)
600
23.622
613
24.134
NA40-16(-H)
680
26.772
693
27.283
NA40-20(-H)
840
33.071
853
33.583
NA40-24(-H)
1,000
39.370
1,013
39.882
Other
Products
NA40