0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
US2:84EUE95BDJ

US2:84EUE95BDJ

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    STARTER,DUPLEX,S1.75,SSOLR,24VAC

  • 数据手册
  • 价格&库存
US2:84EUE95BDJ 数据手册
Data sheet US2:84EUE95BDJ Duplex starter w/o alternator Size 1.75 Three phase full voltage Solid-state overload relay OLR amp range 10-40A 24VAC 50-60Hz Coil Combination type Two 60A disconnect switches Enclosure NEMA type 1 Indoor general purpose use product brand name Class 84 design of the product Duplex controller with two non-fusible disconnect switches without alternator special product feature ESP200 overload relay; Half-size controller General technical data weight [lb] 70 lb Height x Width x Depth [in] 34 × 25 × 8 in touch protection against electrical shock NA for enclosed products installation altitude [ft] at height above sea level maximum 6560 ft ambient temperature [°F] ● during storage -22 ... +149 °F ● during operation -4 ... +104 °F ambient temperature ● during storage -30 ... +65 °C ● during operation -20 ... +40 °C country of origin USA Horsepower ratings yielded mechanical performance [hp] for 3-phase AC motor ● at 200/208 V rated value 10 hp ● at 220/230 V rated value 10 hp ● at 460/480 V rated value 15 hp ● at 575/600 V rated value 15 hp Contactor size of contactor Controller half size 1 3/4 number of NO contacts for main contacts 3 operating voltage for main current circuit at AC at 60 Hz maximum 600 V operational current at AC at 600 V rated value 40 A mechanical service life (switching cycles) of the main contacts typical 10000000 Auxiliary contact number of NC contacts at contactor for auxiliary contacts 0 number of NO contacts at contactor for auxiliary contacts 1 number of total auxiliary contacts maximum 8 contact rating of auxiliary contacts of contactor according to UL 10A@600VAC (A600), 5A@600VDC (P600) Coil type of voltage of the control supply voltage US2:84EUE95BDJ Page 1/3 AC 7/7/2022 Subject to change without notice © Copyright Siemens control supply voltage ● at DC rated value 0 ... 0 V ● at AC at 50 Hz rated value 24 ... 24 V ● at AC at 60 Hz rated value 24 ... 24 V holding power at AC minimum 8.6 W apparent pick-up power of magnet coil at AC 218 VA apparent holding power of magnet coil at AC 25 VA operating range factor control supply voltage rated value of magnet coil 0.85 ... 1.1 percental drop-out voltage of magnet coil related to the input voltage 50 % ON-delay time 19 ... 29 ms OFF-delay time 10 ... 24 ms Overload relay product function ● overload protection Yes ● phase failure detection Yes ● asymmetry detection Yes ● ground fault detection Yes ● test function Yes ● external reset Yes reset function Manual, automatic and remote trip class CLASS 5 / 10 / 20 (factory set) / 30 adjustable current response value current of the currentdependent overload release 10 ... 40 A tripping time at phase-loss maximum 3s relative repeat accuracy 1% number of NC contacts of auxiliary contacts of overload relay 1 number of NO contacts of auxiliary contacts of overload relay 1 operational current of auxiliary contacts of overload relay ● at AC at 600 V 5A ● at DC at 250 V 1A contact rating of auxiliary contacts of overload relay according to UL 5A@600VAC (B600), 1A@250VDC (R300) insulation voltage (Ui) ● with single-phase operation at AC rated value 600 V ● with multi-phase operation at AC rated value 300 V Disconnect Switch response value of switch disconnector 60A / 600V design of fuse holder non-fusible operating class of the fuse link non-fusible Enclosure degree of protection NEMA rating of the enclosure NEMA Type 1 design of the housing indoors, usable on a general basis Mounting/wiring mounting position Vertical fastening method Surface mounting and installation type of electrical connection for supply voltage line-side Box lug tightening torque [lbf·in] for supply 35 ... 35 lbf·in type of connectable conductor cross-sections at line-side at AWG cables single or multi-stranded 1x (14 ... 2 AWG) temperature of the conductor for supply maximum permissible 75 °C material of the conductor for supply AL or CU type of electrical connection for load-side outgoing feeder Screw-type terminals tightening torque [lbf·in] for load-side outgoing feeder 45 ... 45 lbf·in type of connectable conductor cross-sections at AWG cables for load-side outgoing feeder single or multistranded 1x (14 ... 2 AWG) temperature of the conductor for load-side outgoing feeder 75 °C US2:84EUE95BDJ Page 2/3 7/7/2022 Subject to change without notice © Copyright Siemens maximum permissible material of the conductor for load-side outgoing feeder AL or CU type of electrical connection of magnet coil Screw-type terminals tightening torque [lbf·in] at magnet coil 5 ... 12 lbf·in type of connectable conductor cross-sections of magnet coil at AWG cables single or multi-stranded 2x (16 ... 12 AWG) temperature of the conductor at magnet coil maximum permissible 75 °C material of the conductor at magnet coil CU type of electrical connection at contactor for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at contactor for auxiliary contacts 10 ... 15 lbf·in type of connectable conductor cross-sections at contactor at AWG cables for auxiliary contacts single or multistranded 1x (12 AWG), 2x (16 ... 14 AWG), 2x (18 ... 16 AWG) temperature of the conductor at contactor for auxiliary contacts maximum permissible 75 °C material of the conductor at contactor for auxiliary contacts CU type of electrical connection at overload relay for auxiliary contacts Screw-type terminals tightening torque [lbf·in] at overload relay for auxiliary contacts 7 ... 10 lbf·in type of connectable conductor cross-sections at overload relay at AWG cables for auxiliary contacts single or multistranded 2x (20 ... 14 AWG) temperature of the conductor at overload relay for auxiliary contacts maximum permissible 75 °C material of the conductor at overload relay for auxiliary contacts CU Short-circuit current rating design of the fuse link for short-circuit protection of the main circuit required 10kA@600V (Class H or K); 100kA@600V (Class R or J) certificate of suitability NEMA ICS 2; UL 508; CSA 22.2, No.14 Further information Industrial Controls - Product Overview (Catalogs, Brochures,…) www.usa.siemens.com/iccatalog Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/us/Catalog/product?mlfb=US2:84EUE95BDJ Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/US/en/ps/US2:84EUE95BDJ Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, EPLAN macros, ...) http://www.automation.siemens.com/bilddb/cax_de.aspx?mlfb=US2:84EUE95BDJ&lang=en Certificates/approvals https://support.industry.siemens.com/cs/US/en/ps/US2:84EUE95BDJ/certificate last modified: US2:84EUE95BDJ Page 3/3 1/25/2022 7/7/2022 Subject to change without notice © Copyright Siemens
US2:84EUE95BDJ 价格&库存

很抱歉,暂时无法提供与“US2:84EUE95BDJ”相匹配的价格&库存,您可以联系我们找货

免费人工找货