0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TLC2932IPWR

TLC2932IPWR

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    TSSOP14

  • 描述:

    IC PHASE LOCK LOOP HP 14-TSSOP

  • 数据手册
  • 价格&库存
TLC2932IPWR 数据手册
TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 D D D D D D D D Voltage-Controlled Oscillator (VCO) Section: – Complete Oscillator Using Only One External Bias Resistor (RBIAS) – Lock Frequency: 22 MHz to 50 MHz (VDD = 5 V ±5%, TA = – 20°C to 75°C, ×1 Output) 11 MHz to 25 MHz (VDD = 5 V ±5%, TA = – 20°C to 75°C, ×1/2 Output) – Output Frequency . . . ×1 and ×1/2 Selectable Phase-Frequency Detector (PFD) Section Includes a High-Speed Edge-Triggered Detector With Internal Charge Pump Independent VCO, PFD Power-Down Mode Thin Small-Outline Package (14 terminal) CMOS Technology Typical Applications: – Frequency Synthesis – Modulation/Demodulation – Fractional Frequency Division Application Report Available† CMOS Input Logic Level PW PACKAGE† (TOP VIEW) LOGIC VDD SELECT VCO OUT FIN – A FIN – B PFD OUT LOGIC GND 1 2 3 4 5 6 7 VCO VDD BIAS VCO IN VCO GND VCO INHIBIT PFD INHIBIT NC 14 13 12 11 10 9 8 † Available in tape and reel only and ordered as the TLC2932IPWLE. NC – No internal connection description The TLC2932 is designed for phase-locked-loop (PLL) systems and is composed of a voltage-controlled oscillator (VCO) and an edge-triggered-type phase frequency detector (PFD). The oscillation frequency range of the VCO is set by an external bias resistor (RBIAS). The VCO has a 1/2 frequency divider at the output stage. The high-speed PFD with internal charge pump detects the phase difference between the reference frequency input and signal frequency input from the external counter. Both the VCO and the PFD have inhibit functions, which can be used as a power-down mode. The TLC2932 is suitable for use as a high-performance PLL due to the high speed and stable oscillation capability of the device. functional block diagram FIN –A FIN –B PFD INHIBIT 4 5 9 VCO IN Phase Frequency Detector 6 BIAS PFD OUT VCO INHIBIT SELECT 12 13 10 2 VoltageControlled Oscillator 3 VCO OUT AVAILABLE OPTIONS PACKAGE TA SMALL OUTLINE (PW) – 20°C to 75°C TLC2932IPWLE Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet. † TLC2932 Phase-Locked-Loop Building Block With Analog Voltage-Controlled Oscillator and Phase Frequency Detector (SLAA011). Copyright  1997, Texas Instruments Incorporated PRODUCTION DATA information is current as of publication date. Products conform to specifications per the terms of Texas Instruments standard warranty. Production processing does not necessarily include testing of all parameters. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 1 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 Terminal Functions TERMINAL NAME NO. I/O DESCRIPTION FIN – A 4 I Input reference frequency f(REF IN) is applied to FIN – A. FIN – B 5 I Input for VCO external counter output frequency f(FIN – B). FIN – B is nominally provided from the external counter. LOGIC GND 7 GND for the internal logic. LOGIC VDD 1 Power supply for the internal logic. This power supply should be separate from VCO VDD to reduce cross-coupling between supplies. NC 8 No internal connection. PFD INHIBIT 9 I PFD inhibit control. When PFD INHIBIT is high, PFD output is in the high-impedance state, see Table 3. PFD OUT 6 O PFD output. When the PFD INHIBIT is high, PFD output is in the high-impedance state. 13 I Bias supply. An external resistor (RBIAS) between VCO VDD and BIAS supplies bias for adjusting the oscillation frequency range. SELECT 2 I VCO output frequency select. When SELECT is high, the VCO output frequency is × 1/2 and when low, the output frequency is × 1, see Table 1. VCO IN 12 I VCO control voltage input. Nominally the external loop filter output connects to VCO IN to control VCO oscillation frequency. VCO INHIBIT 10 I VCO inhibit control. When VCO INHIBIT is high, VCO OUT is low (see Table 2). VCO GND 11 VCO OUT 3 VCO VDD 14 BIAS GND for VCO. O VCO output. When the VCO INHIBIT is high, VCO output is low. Power supply for VCO. This power supply should be separated from LOGIC VDD to reduce cross-coupling between supplies. detailed description VCO oscillation frequency The VCO oscillation frequency is determined by an external resistor (RBIAS) connected between the VCO VDD and the BIAS terminals. The oscillation frequency and range depends on this resistor value. The bias resistor value for the minimum temperature coefficient is nominally 3.3 kΩ with 3-V at the VCO VDD terminal and nominally 2.2 kΩ with 5-V at the VCO VDD terminal. For the lock frequency range refer to the recommended operating conditions. Figure 1 shows the typical frequency variation and VCO control voltage. VCO Oscillation Frequency (f osc ) VCO Oscillation Frequency Range Bias Resistor (RBIAS) 1/2 VDD VCO Control Voltage (VCO IN) Figure 1. VCO Oscillation Frequency 2 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 VCO output frequency 1/2 divider The TLC2932 SELECT terminal sets the fosc or 1/2 fosc VCO output frequency as shown in Table 1. The 1/2 fosc output should be used for minimum VCO output jitter. Table 1. VCO Output 1/2 Divider Function SELECT VCO OUTPUT Low fosc 1/2 fosc High VCO inhibit function The VCO has an externally controlled inhibit function which inhibits the VCO output. A high level on the VCO INHIBIT terminal stops the VCO oscillation and powers down the VCO. The output maintains a low level during the power-down mode, refer to Table 2. Table 2. VCO Inhibit Function VCO INHIBIT VCO OSCILLATOR VCO OUTPUT Low Active Active IDD(VCO) Normal High Stopped Low level Power Down PFD operation The PFD is a high-speed, edge-triggered detector with an internal charge pump. The PFD detects the phase difference between two frequency inputs supplied to FIN–A and FIN–B as shown in Figure 2. Nominally the reference is supplied to FIN–A, and the frequency from the external counter output is fed to FIN–B. FIN– A FIN– B VOH PFD OUT Hi-Z VOL Figure 2. PFD Function Timing Chart PFD output control A high level on the PFD INHIBIT terminal places the PFD output in the high-impedance state and the PFD stops phase detection as shown in Table 3. A high level on the PFD INHIBIT terminal also can be used as the power-down mode for the PFD. Table 3. VCO Output Control Function PFD INHIBIT DETECTION PFD OUTPUT Low Active Active IDD(PFD) Normal High Stopped Hi-Z Power Down POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 schematics VCO block schematic RBIAS BIAS 1/2 VCO IN VCO Output Bias Control M U X VCO OUT SELECT VCO INHIBIT PFD block schematic Charge Pump VDD FIN – A PFD OUT Detector FIN – B PFD INHIBIT absolute maximum ratings† Supply voltage (each supply), VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 V Input voltage range (each input), VI (see Note 1) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 0.5 V to VDD + 0.5 V Input current (each input), II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Output current (each output), IO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ± 20 mA Continuous total power dissipation, at (or below) TA = 25°C (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . 700 mW Operating free-air temperature range, TA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 20°C to 75°C Storage temperature range, Tstg . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . – 65°C to 150°C Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 260°C † Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. NOTES: 1. All voltage values are with respect to network GND. 2. For operation above 25°C free-air temperature, derate linearly at the rate of 5.6 mW/°C. 4 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 recommended operating conditions PARAMETER VDD = 3 V VDD = 5 V supply see Note 3) Supply voltage voltage, VDD (each supply, Input voltage, VI (inputs except VCO IN) MIN NOM MAX 2.85 3 3.15 4.75 5 5.25 0 Output current, IO (each output) VDD ±2 0 VCO control voltage at VCO IN 0.9 Lock frequency (×1 output) VDD = 3 V VDD = 5 V Lock frequency (×1/2 output) VDD = 3 V VDD = 5 V Bias resistor, resistor RBIAS VDD = 3 V VDD = 5 V 14 VDD 21 22 50 7 10.5 11 25 2.2 3.3 4.3 1.5 2.2 3.3 UNIT V V mA V MHz MHz kΩ NOTE 3: It is recommended that the logic supply terminal (LOGIC VDD) and the VCO supply terminal (VCO VDD) should be at the same voltage and separated from each other. electrical characteristics over recommended operating free-air temperature range, VDD = 3 V (unless otherwise noted) VCO section PARAMETER TEST CONDITIONS VOH VOL High-level output voltage IOH = – 2 mA IOL = 2 mA VIT II Input threshold voltage at SELECT, VCO INHIBIT Zi(VCO IN) IDD(INH) Input impedance VI = VDD or GND VCO IN = 1/2 VDD VCO supply current (inhibit) See Note 4 Low-level output voltage Input current at SELECT, VCO INHIBIT MIN TYP MAX 2.4 V 0.3 0.9 UNIT 1.5 V ±1 µA 10 0.01 IDD(VCO) VCO supply current See Note 5 5 NOTES: 4. Current into VCO VDD, when VCO INHIBIT = VDD, PFD is inhibited. 5. Current into VCO VDD, when VCO IN = 1/2 VDD, RBIAS = 3.3 kΩ, VCO INHIBIT = GND, and PFD is inhibited. V 2.1 MΩ 1 µA 15 mA PFD section PARAMETER TEST CONDITIONS IOH = – 2 mA IOL = 2 mA MIN TYP MAX High-level output voltage IOZ High-impedance-state output current VIH VIL High-level input voltage at FIN–A, FIN–B VIT Ci Input threshold voltage at PFD INHIBIT Input capacitance at FIN–A, FIN–B 5 pF Zi IDD(Z) Input impedance at FIN–A, FIN–B 10 MΩ Low-level output voltage 2.7 UNIT VOH VOL V PFD INHIBIT = high, VI = VDD or GND V ±1 µA 2.7 V Low-level input voltage at FIN–A, FIN–B High-impedance-state PFD supply current 0.2 0.5 0.9 See Note 6 1.5 0.01 2.1 1 V V µA IDD(PFD) PFD supply current See Note 7 0.1 1.5 mA NOTES: 6. Current into LOGIC VDD, when FIN–A, FIN–B = GND, PFD INHIBIT = VDD, no load, and VCO OUT is inhibited. 7. Current into LOGIC VDD, when FIN–A, FIN–B = 1 MHz (VI(PP) = 3 V, rectangular wave), NC = GND, no load, and VCO OUT is inhibited. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 operating characteristics over recommended operating free-air temperature range, VDD = 3 V (unless otherwise noted) VCO section PARAMETER fosc ts(fosc) TEST CONDITIONS Operating oscillation frequency RBIAS = 3.3 kΩ, VCO IN = 1/2 VDD Time to stable oscillation (see Note 8) Measured from VCO INHIBIT↓ tr Rise time tf Fall time MIN TYP MAX UNIT 15 19 23 MHz 10 µs CL = 15 pF, See Figure 3 7 CL = 50 pF, See Figure 3 14 CL = 15 pF, See Figure 3 6 CL = 50 pF, See Figure 3 10 45% 50% 14 12 ns ns Duty cycle at VCO OUT RBIAS = 3.3 kΩ, VCO IN = 1/2 VDD, 55% α(fosc) Temperature coefficient of oscillation frequency RBIAS = 3.3 kΩ, VCO IN = 1/2 VDD, TA = –20°C to 75°C 0.04 %/°C kSVS(fosc) Supply voltage coefficient of oscillation frequency RBIAS = 3.3 kΩ, VCO IN = 1.5 V, VDD = 2.85 V to 3.15 V 0.02 %/mV Jitter absolute (see Note 9) RBIAS = 3.3 kΩ 100 ps NOTES: 8. The time period to the stable VCO oscillation frequency after the VCO INHIBIT terminal is changed to a low level. 9. The low-pass-filter (LPF) circuit is shown in Figure 28 with calculated values listed in Table 7. Jitter performance is highly dependent on circuit layout and external device characteristics. The jitter specification was made with a carefully designed PCB with no device socket. PFD section PARAMETER TEST CONDITIONS MIN TYP MAX fmax tPLZ Maximum operating frequency PFD output disable time from low level 21 50 tPHZ tPZL PFD output disable time from high level 23 50 tPZH tr PFD output enable time to high level tf Fall time 6 PFD output enable time to low level 20 See Figures 4 and 5 and Table 4 Rise time pF CL = 15 pF, POST OFFICE BOX 655303 See Figure 4 • DALLAS, TEXAS 75265 UNIT MHz ns 11 30 10 30 2.3 10 ns 2.1 10 ns ns TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 electrical characteristics over recommended operating free-air temperature range, VDD = 5 V (unless otherwise noted) VCO section PARAMETER TEST CONDITIONS VOH VOL High-level output voltage IOH = – 2 mA IOL = 2 mA VIT II Input threshold voltage at SELECT, VCO INHIBIT Zi(VCO IN) IDD(INH) Input impedance VI = VDD or GND VCO IN = 1/2 VDD VCO supply current (inhibit) See Note 4 Low-level output voltage Input current at SELECT, VCO INHIBIT MIN TYP MAX 4 V 0.5 1.5 UNIT 2.5 V ±1 µA 10 0.01 IDD(VCO) VCO supply current See Note 5 15 NOTES: 4. Current into VCO VDD, when VCO INHIBIT = VDD, and PFD is inhibited. 5. Current into VCO VDD, when VCO IN = 1/2 VDD, RBIAS = 3.3 kΩ, VCO INHIBIT = GND, and PFD is inhibited. V 3.5 MΩ 1 µA 35 mA PFD section PARAMETER TEST CONDITIONS IOH = 2 mA IOL = 2 mA MIN TYP MAX VOH VOL High-level output voltage IOZ High-impedance-state output current VIH VIL High-level input voltage at FIN–A, FIN–B VIT Ci Input threshold voltage at PFD INHIBIT Input capacitance at FIN–A, FIN–B 5 pF Zi IDD(Z) Input impedance at FIN–A, FIN–B 10 MΩ Low-level output voltage 4.5 UNIT V PFD INHIBIT = high, VI = VDD or GND V ±1 µA 4.5 V Low-level input voltage at FIN–A, FIN–B High-impedance-state PFD supply current 0.2 1.5 See Note 6 2.5 0.01 1 V 3.5 V 1 µA IDD(PFD) PFD supply current See Note 7 0.15 3 mA NOTES: 6. Current into LOGIC VDD, when FIN–A, FIN–B = GND, PFD INHIBIT = VDD, no load, and VCO OUT is inhibited. 7. Current into LOGIC VDD, when FIN–A, FIN–B = 1 MHz (VI(PP) = 5 V, rectangular wave), PFD INHIBIT = GND, no load, and VCO OUT is inhibited. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 7 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 operating characteristics over recommended operating free-air temperature range, VDD = 5 V (unless otherwise noted) VCO section PARAMETER fosc ts(fosc) TEST CONDITIONS Operating oscillation frequency RBIAS = 2.2 kΩ, VCO IN = 1/2 VDD Time to stable oscillation (see Note 8) Measured from VCO INHIBIT↓ tr Rise time tf Fall time MIN TYP MAX UNIT 30 41 52 MHz 10 µs CL = 15 pF, See Figure 3 5.5 CL = 50 pF, See Figure 3 8 CL = 15 pF, See Figure 3 5 CL = 50 pF, See Figure 3 6 Duty cycle at VCO OUT RBIAS = 2.2 kΩ, VCO IN = 1/2 VDD, α(fosc) Temperature coefficient of oscillation frequency RBIAS = 2.2 kΩ, VCO IN = 1/2 VDD, TA = –20°C to 75°C kSVS(fosc) Supply voltage coefficient of oscillation frequency RBIAS = 2.2 kΩ, VCO IN = 2.5 V, VDD = 4.75 V to 5.25 V Jitter absolute (see Note 9) RBIAS = 2.2 kΩ 45% 50% 10 10 ns ns 55% 0.06 %/°C 0.006 %/mV 100 ps NOTES: 8: The time period to the stable VCO oscillation frequency after the VCO INHIBIT terminal is changed to a low level. 9. The LPF circuit is shown in Figure 28 with calculated values listed in Table 7. Jitter performance is highly dependent on circuit layout and external device characteristics. The jitter specification was made with a carefully designed PCB with no device socket. PFD section PARAMETER TEST CONDITIONS fmax tPLZ Maximum operating frequency tPHZ tPZL PFD output disable time from high level tPZH tr PFD output enable time to high level tf Fall time 8 TYP MAX 21 40 20 40 7.3 20 6.5 20 2.3 10 ns 1.7 10 ns 40 PFD output disable time from low level PFD output enable time to low level MIN See Figures 4 and 5 and Table 4 Rise time CL = 15 pF, pF POST OFFICE BOX 655303 See Figure 4 • DALLAS, TEXAS 75265 UNIT MHz ns ns TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 PARAMETER MEASUREMENT INFORMATION 90% 90% VCO OUT 10% 10% tr tf Figure 3. VCO Output Voltage Waveform FIN– A† FIN– B† VDD VDD GND GND VDD VDD GND GND VDD PFD INHIBIT VDD 50% 50% GND tPHZ tr PFD OUT 10% GND VOH 90% 50% tPLZ tf 90% 50% GND 50% 10% VDD 50% VOL tPZL tPZH (a) OUTPUT PULLDOWN (see Figure 5 and Table 4) (b) OUTPUT PULLUP (see Figure 5 and Table 4) † FIN–A and FIN–B are for reference phase only, not for timing. Figure 4. PFD Output Voltage Waveform Table 4. PFD Output Test Conditions PARAMETER RL CL tPZH tPHZ tr tPZL tPLZ tf S1 S2 Open Close VDD Test Point S1 1 kΩ RL DUT 15 pF Close PFD OUT Open CL S2 Figure 5. PFD Output Test Conditions POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 9 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 TYPICAL CHARACTERISTICS VCO OSCILLATION FREQUENCY vs VCO CONTROL VOLTAGE VCO OSCILLATION FREQUENCY vs VCO CONTROL VOLTAGE VDD = 3 V RBIAS = 2.2 kΩ 100 VDD = 5 V RBIAS = 1.5 kΩ – 20°C 25°C f osc – VCO Oscillation Frequency – MHz f osc – VCO Oscillation Frequency – MHz 40 30 75°C 20 10 – 20°C 80 25°C 60 75°C 40 20 0 0 1 2 VCO IN – VCO Control Voltage – V 3 4 1 2 3 VCO IN – VCO Control Voltage – V 0 Figure 6 Figure 7 VCO OSCILLATION FREQUENCY vs VCO CONTROL VOLTAGE VCO OSCILLATION FREQUENCY vs VCO CONTROL VOLTAGE 80 VDD = 3 V RBIAS = 3.3 kΩ f osc – VCO Oscillation Frequency – MHz f osc – VCO Oscillation Frequency – MHz 40 – 20°C 30 75°C 25°C 20 10 0 0 1 2 VCO IN – VCO Control Voltage – V 3 VDD = 5 V RBIAS = 2.2 kΩ – 20°C 60 75°C 25°C 40 20 0 0 Figure 8 10 5 1 2 3 4 VCO IN – VCO Control Voltage – V Figure 9 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 TYPICAL CHARACTERISTICS VCO OSCILLATION FREQUENCY vs VCO CONTROL VOLTAGE VCO OSCILLATION FREQUENCY vs VCO CONTROL VOLTAGE 80 VDD = 3 V RBIAS = 4.3 kΩ f osc – VCO Oscillation Frequency – MHz f osc – VCO Oscillation Frequency – MHz 40 30 75°C 25°C 20 – 20°C 10 0 0 1 2 VCO IN – VCO Control Voltage – V VDD = 5 V RBIAS = 3.3 kΩ 60 40 25°C 20 – 20°C 0 3 75°C 0 1 2 3 4 VCO IN – VCO Control Voltage – V Figure 10 Figure 11 VCO OSCILLATION FREQUENCY vs BIAS RESISTOR VCO OSCILLATION FREQUENCY vs BIAS RESISTOR 30 60 VDD = 3 V VCO IN = 1/2 VDD TA = 25°C f osc – VCO Oscillation Frequency – MHz f osc – VCO Oscillation Frequency – MHz 5 25 20 15 10 2 2.5 3.5 4 3 RBIAS – Bias Resistor – kΩ 4.5 VDD = 5 V VCO IN = 1/2 VDD TA = 25°C 50 40 30 20 1.5 Figure 12 2 2.5 3 RBIAS – Bias Resistor – kΩ 3.5 Figure 13 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 11 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 TYPICAL CHARACTERISTICS TEMPERATURE COEFFICIENT OF OSCILLATION FREQUENCY vs BIAS RESISTOR 0.4 VDD = 3 V VCO IN = 1/2 VDD TA = – 20°C to 75°C α (f osc) – Temperature Coefficient of Oscillation Frequency – % / °C α (f osc) – Temperature Coefficient of Oscillation Frequency – % / °C 0.4 TEMPERATURE COEFFICIENT OF OSCILLATION FREQUENCY vs BIAS RESISTOR 0.3 0.2 0.1 0 2 3 2.5 4 3.3 3.5 RBIAS – Bias Resistor – kΩ VDD = 5 V VCO IN = 1/2 VDD TA = – 20°C to 75°C 0.3 0.2 0.1 0 1.5 4.5 VCO OSCILLATION FREQUENCY vs VCO SUPPLY VOLTAGE VCO OSCILLATION FREQUENCY vs VCO SUPPLY VOLTAGE 48 24 RBIAS = 3.3 kΩ VCO IN = 1.5 V TA = 25°C f osc – VCO Oscillation Frequency – MHz f osc – VCO Oscillation Frequency – MHz 3.5 Figure 15 Figure 14 22 20 18 16 3.05 3 VDD – VCO Supply Voltage – V 3.15 RBIAS = 2.2 kΩ VCO IN = 1/2 VDD TA = 25°C 44 40 36 32 4.75 Figure 16 12 2 2.5 3 2.2 RBIAS – Bias Resistor – kΩ 5 VDD – VCO Supply Voltage – V Figure 17 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 5.25 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 TYPICAL CHARACTERISTICS 0.05 VDD = 2.85 V to 3.15 V VCO IN = 1/2 VDD TA = 25°C 0.04 0.03 0.02 0.01 0 2 2.5 3 3.5 4 RBIAS – Bias Resistor – kΩ 4.5 SUPPLY VOLTAGE COEFFICIENT OF VCO OSCILLATION FREQUENCY vs BIAS RESISTOR α (f osc) – Supply Voltage Coefficient of VCO Oscillation Frequency – % / V α (f osc) – Supply Voltage Coefficient of VCO Oscillation Frequency – % / V SUPPLY VOLTAGE COEFFICIENT OF VCO OSCILLATION FREQUENCY vs BIAS RESISTOR VDD = 4.75 V to 5.25 V VCO IN = 1/2 VDD TA = 25°C 0.01 0.005 0 1.5 2 2.5 3 RBIAS – Bias Resistor – kΩ Figure 18 Figure 19 RECOMMENDED LOCK FREQUENCY (×1 OUTPUT) vs BIAS RESISTOR RECOMMENDED LOCK FREQUENCY (×1 OUTPUT) vs BIAS RESISTOR 60 30 VDD = 2.85 V to 3.15 V TA = – 20°C to 75°C Recommended Lock Frequency – MHz Recommended Lock Frequency – MHz 3.5 25 20 15 10 2 2.5 3 3.5 4 RBIAS – Bias Resistor – kΩ 4.5 VDD = 4.75 V to 5.25 V TA = – 20°C to 75°C 50 40 30 20 10 1.5 Figure 20 2 2.5 3 RBIAS – Bias Resistor – kΩ 3.5 Figure 21 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 13 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 APPLICATION INFORMATION RECOMMENDED LOCK FREQUENCY (×1/2 OUTPUT) vs BIAS RESISTOR RECOMMENDED LOCK FREQUENCY (×1/2 OUTPUT) vs BIAS RESISTOR 30 VDD = 2.85 V to 3.15 V TA = – 20°C to 75°C SELECT = VDD Recommended Lock Frequency – MHz Recommended Lock Frequency – MHz 15 12.5 10 7.5 5 2 2.5 3.5 4 3 RBIAS – Bias Resistor – kΩ 4.5 25 VDD = 4.75 V to 5.25 V TA = – 20°C to 75°C SELECT = VDD 20 15 10 5 1.5 Figure 23 Figure 22 14 2 2.5 3 RBIAS – Bias Resistor – kΩ POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 3.5 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 APPLICATION INFORMATION gain of VCO and PFD Figure 24 is a block diagram of the PLL. The countdown N value depends on the input frequency and the desired VCO output frequency according to the system application requirements. The Kp and KV values are obtained from the operating characteristics of the device as shown in Figure 24. Kp is defined from the phase detector VOL and VOH specifications and the equation shown in Figure 24(b). KV is defined from Figures 8, 9, 10, and 11 as shown in Figure 24(c). The parameters for the block diagram with the units are as follows: KV : VCO gain (rad/s/V) Kp : PFD gain (V/rad) Kf : LPF gain (V/V) KN : count down divider gain (1/N) Divider (KN = 1/N) PFD (Kp) f REF VCO (KV) TLC2932 LPF (Kf) VOH (a) – 2π – π 0 π 2π fMAX VOH VOL fMIN Range of Comparison external counter When a large N counter is required by the application, there is a possibility that the PLL response becomes slow due to the counter response delay time. In the case of a high frequency application, the counter delay time should be accounted for in the overall PLL design. VIN MIN Kp = VOH – VOL 4π (b) KV = VIN MAX 2π(fMAX – fMIN) VIN MAX – VIN MIN (c) Figure 24. Example of a PLL Block Diagram RBIAS The external bias resistor sets the VCO center frequency with 1/2 VDD applied to the VCO IN terminal. However, for optimum temperature performance, a resistor value of 3.3 kΩ with a 3-V supply and a resistor value of 2.5 kΩ for a 5-V supply is recommended. For the most accurate results, a metal-film resistor is the better choice but a carbon-compositiion resistor can be used with excellent results also. A 0.22 µF capacitor should be connected from the BIAS terminal to ground as close to the device terminals as possible. hold-in range From the technical literature, the maximum hold-in range for an input frequency step for the three types of filter configurations shown in Figure 25 is as follows: DwH ] 0.8 Where ǒ Ǔ ǒ Ǔ ǒ RǓ Kp K V K ( ) f Kf (∞) = the filter transfer function value at ω = ∞ POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 15 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 APPLICATION INFORMATION low-pass-filter (LPF) configurations Many excellent references are available that include detailed design information about LPFs and should be consulted for additional information. Lag-lead filters or active filters are often used. Examples of LPFs are shown in Figure 25. When the active filter of Figure 25(c) is used, the reference should be applied to FIN-B because of the amplifier inversion. Also, in practical filter implementations, C2 is used as additional filtering at the VCO input. The value of C2 should be equal to or less than one tenth the value of C1. C2 R1 R1 VI VO T1 = C1R1 C1 VI VO T1 = C1R1 T2 = C1R2 R2 C1 R2 C2 C1 – VI R1 (a) LAG FILTER A VO T1 = C1R1 T2 = C1R2 (b) LAG-LEAD FILTER (c) ACTIVE FILTER Figure 25. LPF Examples for PLL the passive filter The transfer function for the lag-lead filter shown in Figure 25(b) is; V V O IN + 1 )1s)@ s(T1@ T2 ) T2) Where T1 + R1 @ C1 and T2 + R2 @ C1 Using this filter makes the closed loop PLL system a second-order type 1 system. The response curves of this system to a unit step are shown in Figure 26. the active filter When using the active integrator shown in Figure 25(c), the phase detector inputs must be reversed since the integrator adds an additional inversion. Therefore, the input reference frequency should be applied to the FIN-B terminal and the output of the VCO divider should be applied to the input reference terminal, FIN-A. The transfer function for the active filter shown in Figure 25(c) is: F(s) + 1 )s @s @R1R2@ @C1C1 Using this filter makes the closed loop PLL system a second-order type 2 system. The response curves of this system to a unit step are shown in Figure 27. basic design example The following design example presupposes that the input reference frequency and the required frequency of the VCO are within the respective ranges of the device. 16 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 APPLICATION INFORMATION basic design example (continued) Assume the loop has to have a 100 µs settling time (ts) with a countdown N = 8. Using the Type 1, second order response curves of Figure 26, a value of 4.5 radians is selected for ωnts with a damping factor of 0.7. This selection gives a good combination for settling time, accuracy, and loop gain margin. The initial parameters are summarized in Table 5. The loop constants, KV and Kp, are calculated from the data sheet specifications and Table 6 shows these values. The natural loop frequency is calculated as follows: Since w nt s Then wn + 4.5 + 1004.5ms + 45 k-radiansńsec Table 5. Design Parameters PARAMETER SYMBOL VALUE UNITS Division factor N 8 Lockup time t 100 µs ωnt 4.5 rad ζ 0.7 Radian value to selected lockup time Damping factor Table 6. Device Specifications PARAMETER SYMBOL VCO gain fMAX fMIN VALUE UNITS 76.6 Mrad/V/s 70 MHz 20 MHz 5 V KV VIN MAX VIN MIN PFD gain Kp 0.9 V 0.342357 V/rad Table 7. Calculated Values PARAMETER Natural angular frequency SYMBOL VALUE UNITS ωn 45000 rad/sec 3.277 Mrad/sec K = (KV • Kp)/N Lag-lead filter Calculated value Nearest standard value R1 15870 16000 Ω Calculated value Nearest standard value R2 308 300 Ω Selected value C1 0.1 µF POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 17 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 APPLICATION INFORMATION Using the low-pass filter in Figure 25(b) and divider ratio N, the transfer function for phase and frequency are shown in equations 1 and 2. Note that the transfer function for phase differs from the transfer function for frequency by only the divider value N. The difference arises from the fact that the feedback for phase is unity while the feedback for frequency is 1/N. Hence, transfer function of Figure 24 (a) for phase is F2(s) + F1(s) N @ @) K Kp (T1 V T2) ȱȧ ȧȧ Ȳ s2 ȱȧ ȧȧ Ȳ ƪ )s 1) @ @@ )@ ) ƫ 1 s T2 Kp K T2 V N (T1 T2) ) @ @) Kp K OUT(s) F REF(s) Kp @ K V + (T1 ) T2) s2 Ǹ@@ ƪ )s@ 1) @ @ )@ @ ) ƫ 1 s T2 K p K T2 V N (T1 T2) (1) V N (T1 T2) and the transfer function for frequency is F ȳȧ ȧȧ ȴ ȳȧ ȧȧ ȴ ) N@(T1@)VT2) Kp K (2) The standard two-pole denominator is D = s2 + 2 ζ ωn s + ωn2 and comparing the coefficients of the denominator of equation 1 and 2 with the standard two-pole denominator gives the following results. wn + Kp N (T1 K ) T2) V Solving for T1 + T2 T1 ) T2 + KNp@@wKV2 ǒ (3) n Ǔ and by using this value for T1 + T2 in equation 3 the damping factor is z + w2n @ T2 ) Kp @N K V solving for T2 T2 + 2wz – Kp @N K @ @ V then by substituting for T2 in equation 3 K Kp 2 z V N T1 – w 2 K n N wn p KV + 18 ) @ POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 ƪ @ ƫ APPLICATION INFORMATION From the circuit constants and the initial design parameters then R2 R1 + ȱȧ Ȳ + z N wn * Kp K 2 Kp wn @ @ 2 z N * ) w K n p@K N Kv 2 V 1 C1 ȳȧ ȴ 1 C1 V The capacitor, C1, is usually chosen between 1 µF and 0.1 µF to allow for reasonable resistor values and physical capacitor size. In this example, C1 is chosen to be 0.1 µF and the corresponding R1 and R2 calculated values are listed in Table 7. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 19 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 APPLICATION INFORMATION 1.9 1.8 z = 0.1 1.7 z = 0.2 1.6 z = 0.3 1.5 z = 0.4 1.4 z = 0.6 z = 0.5 1.3 z = 0.7 1.2 φ 2 (t), Normalized Response z = 0.8 1.1 1 0.9 z = 1.0 0.8 z = 1.5 0.7 0.6 z = 2.0 0.5 0.4 0.3 0.2 0.1 0 0 1 2 3 4 5 6 ωnts = 4.5 7 8 9 10 ωnt Figure 26. Type 1 Second-Order Step Response 20 POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 11 12 13 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 APPLICATION INFORMATION 1.9 ζ = 0.1 1.8 1.7 ζ = 0.2 1.6 ζ = 0.3 1.5 ζ = 0.4 ζ = 0.5 1.4 ζ = 0.6 1.3 φ 0 (t), Normalized Output Frequency ζ = 0.7 1.2 1.1 1 0.9 ζ = 0.8 0.8 ζ = 1.0 0.7 ζ = 2.0 0.6 0.5 0.4 0.3 0.2 0.1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 ωnt Figure 27. Type 2 Second-Order Step Response POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 21 TLC2932 HIGH-PERFORMANCE PHASE-LOCKED LOOP SLAS097E – SEPTEMBER 1994 – REVISED MAY 1997 APPLICATION INFORMATION AVDD VDD 1 2 VCO LOGIC VDD (Digital) SELECT 14 VCO VDD 1/2 fosc R1† 13 BIAS 0.22 µF REF IN DGND 3 VCO OUT 4 FIN – A 5 FIN – B 6 PFD OUT VCO IN VCO GND R3 12 11 C2 R2 C1 VCO INHIBIT 10 AGND 7 Divide By N Phase Comparator PFD INHIBIT 9 LOGIC GND (Digital) NC 8 DGND S3 S4 S5 R4 R5 R6 DGND DVDD † RBIAS resistor Figure 28. Evaluation and Operation Schematic PCB layout considerations The TLC2932 contains a high frequency analog oscillator; therefore, very careful breadboarding and printed-circuit-board (PCB) layout is required for evaluation. The following design recommendations benefit the TLC2932 user: D D D D D D 22 External analog and digital circuitry should be physically separated and shielded as much as possible to reduce system noise. RF breadboarding or RF PCB techniques should be used throughout the evaluation and production process. Wide ground leads or a ground plane should be used on the PCB layouts to minimize parasitic inductance and resistance. The ground plane is the better choice for noise reduction. LOGIC VDD and VCO VDD should be separate PCB traces and connected to the best filtered supply point available in the system to minimize supply cross-coupling. VCO VDD to GND and LOGIC VDD to GND should be decoupled with a 0.1-µF capacitor placed as close as possible to the appropriate device terminals. The no-connection (NC) terminal on the package should be connected to GND. POST OFFICE BOX 655303 • DALLAS, TEXAS 75265 PACKAGE OPTION ADDENDUM www.ti.com 15-Apr-2017 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan Lead/Ball Finish MSL Peak Temp (2) (6) (3) TLC2932IPW NRND TSSOP PW 14 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC2932IPWG4 NRND TSSOP PW 14 90 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC2932IPWR NRND TSSOP PW 14 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM TLC2932IPWRG4 NRND TSSOP PW 14 2000 Green (RoHS & no Sb/Br) CU NIPDAU Level-1-260C-UNLIM Op Temp (°C) Device Marking (4/5) Y2932 -40 to 85 Y2932 Y2932 -40 to 85 Y2932 (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) Eco Plan - The planned eco-friendly classification: Pb-Free (RoHS), Pb-Free (RoHS Exempt), or Green (RoHS & no Sb/Br) - please check http://www.ti.com/productcontent for the latest availability information and additional product content details. TBD: The Pb-Free/Green conversion plan has not been defined. Pb-Free (RoHS): TI's terms "Lead-Free" or "Pb-Free" mean semiconductor products that are compatible with the current RoHS requirements for all 6 substances, including the requirement that lead not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, TI Pb-Free products are suitable for use in specified lead-free processes. Pb-Free (RoHS Exempt): This component has a RoHS exemption for either 1) lead-based flip-chip solder bumps used between the die and package, or 2) lead-based die adhesive used between the die and leadframe. The component is otherwise considered Pb-Free (RoHS compatible) as defined above. Green (RoHS & no Sb/Br): TI defines "Green" to mean Pb-Free (RoHS compatible), and free of Bromine (Br) and Antimony (Sb) based flame retardants (Br or Sb do not exceed 0.1% by weight in homogeneous material) (3) MSL, Peak Temp. - The Moisture Sensitivity Level rating according to the JEDEC industry standard classifications, and peak solder temperature. (4) There may be additional marking, which relates to the logo, the lot trace code information, or the environmental category on the device. (5) Multiple Device Markings will be inside parentheses. Only one Device Marking contained in parentheses and separated by a "~" will appear on a device. If a line is indented then it is a continuation of the previous line and the two combined represent the entire Device Marking for that device. (6) Lead/Ball Finish - Orderable Devices may have multiple material finish options. Finish options are separated by a vertical ruled line. Lead/Ball Finish values may wrap to two lines if the finish value exceeds the maximum column width. Addendum-Page 1 Samples PACKAGE OPTION ADDENDUM www.ti.com 15-Apr-2017 Important Information and Disclaimer:The information provided on this page represents TI's knowledge and belief as of the date that it is provided. TI bases its knowledge and belief on information provided by third parties, and makes no representation or warranty as to the accuracy of such information. Efforts are underway to better integrate information from third parties. TI has taken and continues to take reasonable steps to provide representative and accurate information but may not have conducted destructive testing or chemical analysis on incoming materials and chemicals. TI and TI suppliers consider certain information to be proprietary, and thus CAS numbers and other limited information may not be available for release. In no event shall TI's liability arising out of such information exceed the total purchase price of the TI part(s) at issue in this document sold by TI to Customer on an annual basis. Addendum-Page 2 PACKAGE MATERIALS INFORMATION www.ti.com 14-Jul-2012 TAPE AND REEL INFORMATION *All dimensions are nominal Device TLC2932IPWR Package Package Pins Type Drawing TSSOP PW 14 SPQ Reel Reel A0 Diameter Width (mm) (mm) W1 (mm) 2000 330.0 12.4 Pack Materials-Page 1 6.9 B0 (mm) K0 (mm) P1 (mm) 5.6 1.6 8.0 W Pin1 (mm) Quadrant 12.0 Q1 PACKAGE MATERIALS INFORMATION www.ti.com 14-Jul-2012 *All dimensions are nominal Device Package Type Package Drawing Pins SPQ Length (mm) Width (mm) Height (mm) TLC2932IPWR TSSOP PW 14 2000 367.0 367.0 35.0 Pack Materials-Page 2 IMPORTANT NOTICE Texas Instruments Incorporated (TI) reserves the right to make corrections, enhancements, improvements and other changes to its semiconductor products and services per JESD46, latest issue, and to discontinue any product or service per JESD48, latest issue. Buyers should obtain the latest relevant information before placing orders and should verify that such information is current and complete. TI’s published terms of sale for semiconductor products (http://www.ti.com/sc/docs/stdterms.htm) apply to the sale of packaged integrated circuit products that TI has qualified and released to market. Additional terms may apply to the use or sale of other types of TI products and services. Reproduction of significant portions of TI information in TI data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limitations, and notices. TI is not responsible or liable for such reproduced documentation. Information of third parties may be subject to additional restrictions. Resale of TI products or services with statements different from or beyond the parameters stated by TI for that product or service voids all express and any implied warranties for the associated TI product or service and is an unfair and deceptive business practice. TI is not responsible or liable for any such statements. Buyers and others who are developing systems that incorporate TI products (collectively, “Designers”) understand and agree that Designers remain responsible for using their independent analysis, evaluation and judgment in designing their applications and that Designers have full and exclusive responsibility to assure the safety of Designers' applications and compliance of their applications (and of all TI products used in or for Designers’ applications) with all applicable regulations, laws and other applicable requirements. Designer represents that, with respect to their applications, Designer has all the necessary expertise to create and implement safeguards that (1) anticipate dangerous consequences of failures, (2) monitor failures and their consequences, and (3) lessen the likelihood of failures that might cause harm and take appropriate actions. Designer agrees that prior to using or distributing any applications that include TI products, Designer will thoroughly test such applications and the functionality of such TI products as used in such applications. TI’s provision of technical, application or other design advice, quality characterization, reliability data or other services or information, including, but not limited to, reference designs and materials relating to evaluation modules, (collectively, “TI Resources”) are intended to assist designers who are developing applications that incorporate TI products; by downloading, accessing or using TI Resources in any way, Designer (individually or, if Designer is acting on behalf of a company, Designer’s company) agrees to use any particular TI Resource solely for this purpose and subject to the terms of this Notice. TI’s provision of TI Resources does not expand or otherwise alter TI’s applicable published warranties or warranty disclaimers for TI products, and no additional obligations or liabilities arise from TI providing such TI Resources. TI reserves the right to make corrections, enhancements, improvements and other changes to its TI Resources. TI has not conducted any testing other than that specifically described in the published documentation for a particular TI Resource. Designer is authorized to use, copy and modify any individual TI Resource only in connection with the development of applications that include the TI product(s) identified in such TI Resource. NO OTHER LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE TO ANY OTHER TI INTELLECTUAL PROPERTY RIGHT, AND NO LICENSE TO ANY TECHNOLOGY OR INTELLECTUAL PROPERTY RIGHT OF TI OR ANY THIRD PARTY IS GRANTED HEREIN, including but not limited to any patent right, copyright, mask work right, or other intellectual property right relating to any combination, machine, or process in which TI products or services are used. Information regarding or referencing third-party products or services does not constitute a license to use such products or services, or a warranty or endorsement thereof. Use of TI Resources may require a license from a third party under the patents or other intellectual property of the third party, or a license from TI under the patents or other intellectual property of TI. TI RESOURCES ARE PROVIDED “AS IS” AND WITH ALL FAULTS. TI DISCLAIMS ALL OTHER WARRANTIES OR REPRESENTATIONS, EXPRESS OR IMPLIED, REGARDING RESOURCES OR USE THEREOF, INCLUDING BUT NOT LIMITED TO ACCURACY OR COMPLETENESS, TITLE, ANY EPIDEMIC FAILURE WARRANTY AND ANY IMPLIED WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR PURPOSE, AND NON-INFRINGEMENT OF ANY THIRD PARTY INTELLECTUAL PROPERTY RIGHTS. TI SHALL NOT BE LIABLE FOR AND SHALL NOT DEFEND OR INDEMNIFY DESIGNER AGAINST ANY CLAIM, INCLUDING BUT NOT LIMITED TO ANY INFRINGEMENT CLAIM THAT RELATES TO OR IS BASED ON ANY COMBINATION OF PRODUCTS EVEN IF DESCRIBED IN TI RESOURCES OR OTHERWISE. IN NO EVENT SHALL TI BE LIABLE FOR ANY ACTUAL, DIRECT, SPECIAL, COLLATERAL, INDIRECT, PUNITIVE, INCIDENTAL, CONSEQUENTIAL OR EXEMPLARY DAMAGES IN CONNECTION WITH OR ARISING OUT OF TI RESOURCES OR USE THEREOF, AND REGARDLESS OF WHETHER TI HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. Unless TI has explicitly designated an individual product as meeting the requirements of a particular industry standard (e.g., ISO/TS 16949 and ISO 26262), TI is not responsible for any failure to meet such industry standard requirements. Where TI specifically promotes products as facilitating functional safety or as compliant with industry functional safety standards, such products are intended to help enable customers to design and create their own applications that meet applicable functional safety standards and requirements. Using products in an application does not by itself establish any safety features in the application. Designers must ensure compliance with safety-related requirements and standards applicable to their applications. Designer may not use any TI products in life-critical medical equipment unless authorized officers of the parties have executed a special contract specifically governing such use. Life-critical medical equipment is medical equipment where failure of such equipment would cause serious bodily injury or death (e.g., life support, pacemakers, defibrillators, heart pumps, neurostimulators, and implantables). Such equipment includes, without limitation, all medical devices identified by the U.S. Food and Drug Administration as Class III devices and equivalent classifications outside the U.S. TI may expressly designate certain products as completing a particular qualification (e.g., Q100, Military Grade, or Enhanced Product). Designers agree that it has the necessary expertise to select the product with the appropriate qualification designation for their applications and that proper product selection is at Designers’ own risk. Designers are solely responsible for compliance with all legal and regulatory requirements in connection with such selection. Designer will fully indemnify TI and its representatives against any damages, costs, losses, and/or liabilities arising out of Designer’s noncompliance with the terms and provisions of this Notice. Mailing Address: Texas Instruments, Post Office Box 655303, Dallas, Texas 75265 Copyright © 2017, Texas Instruments Incorporated
TLC2932IPWR 价格&库存

很抱歉,暂时无法提供与“TLC2932IPWR”相匹配的价格&库存,您可以联系我们找货

免费人工找货