0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TLC59116ITPWRQ1

TLC59116ITPWRQ1

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    TSSOP28

  • 描述:

    IC LED DVR 16CH FM I2C 28TSSOP

  • 数据手册
  • 价格&库存
TLC59116ITPWRQ1 数据手册
Product Folder Sample & Buy Support & Community Tools & Software Technical Documents TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 TLC59116-Q1 16-Channel FM+ I2C-Bus Constant-Current LED Sink Driver 1 1 Features • • • • • • • • • • • • • • • • • • • • • • 3.3 V or 5 V Supply Voltage 5.5 V Tolerant Inputs 28-Pin Thin Shrink Small-Outline Package (TSSOP) (PW-28) –40°C to +105°C Operation • 2 Applications • • • General LED Lighting Applications Backlight for center stack buttons Backlight for cluster indicators 3 Description The TLC59116-Q1 is an I2C-Bus controlled 16channel LED driver that is optimized for red/green/blue/amber (RGBA) color mixing and backlight application. Each LED output has its own 8bit resolution (256 steps) fixed-frequency individual PWM controller that operates at 97-kHz, with a duty cycle that is adjustable from 0% to 99.6%. Device Information PART NUMBER TLC59116-Q1 (1) PACKAGE BODY SIZE (NOM) TSSOP (28) 9.70 mm × 4.40 mm (1) For all available packages, see the orderable addendum at the end of the datasheet. TLC59116-Q1 Typical Application 3.3 V or 5V ... TLC59116-Q1 SCL SCL VCC SDA SDA OUT15 RESET OUT14 A0–A3 OUT13 RESET ... • • 16 LED Drivers (Each Output Programmable at Off, On, Programmable LED Brightness, or Programmable Group Dimming and Blinking Mixed With Individual LED Brightness) 16 Constant-Current Output Channels 256-Step (8-Bit) Linear Programmable Brightness Per LED Output Varying From Fully Off (Default) to Maximum Brightness Using a 97-kHz PWM Signal 256-Step Group Brightness Control Allows General Dimming [Using a 190-Hz PWM Signal From Fully Off to Maximum Brightness (Default)] 256-Step Group Blinking With Frequency Programmable From 24-Hz to 10.73 s and Duty Cycle From 0% to 99.6% Four Hardware Address Pins Allow 14 TLC59116Q1 Devices to Be Connected to Same I2C Bus Four Software-Programmable I2C Bus Addresses (One LED Group Call Address and Three LED Sub Call Addresses) Allow Groups of Devices to Be Addressed at Same Time in Any Combination Software Reset Feature (SWRST Call) Allows Device to Be Reset Through I2C Bus Up to 14 Possible Hardware-Adjustable Individual I2C Bus Addresses Per Device, So That Each Device Can Be Programmed Open-Load and Overtemperature Detection Mode to Detect Individual LED Errors Output State Change Programmable on Acknowledge or Stop Command to Update Outputs Byte-by-Byte or All at Same Time (Default to Change on Stop) Output Current Adjusted Through an External Resistor Constant Output Current Range: 5-mA to 120-mA Maximum Output Voltage: 17 V 25-MHz Internal Oscillator Requires No External Components 1-MHz Fast-mode Plus (FMT) Compatible I2C-Bus Interface With 30-mA High-Drive Capability on SDA Output for Driving High-Capacitive Buses Internal Power-On Reset Noise Filter on SCL and SDA Inputs No Glitch on Power-Up Active-Low Reset Supports Hot Insertion Low Standby Current MCU • OUT1 OUT0 REXT GND REXT 1 An IMPORTANT NOTICE at the end of this data sheet addresses availability, warranty, changes, use in safety-critical applications, intellectual property matters and other important disclaimers. PRODUCTION DATA. TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com Table of Contents 1 2 3 4 5 6 7 8 9 Features .................................................................. Applications ........................................................... Description ............................................................. Revision History..................................................... Description (continued)......................................... Pin Configuration and Functions ......................... Specifications......................................................... 1 1 1 2 3 4 5 7.1 7.2 7.3 7.4 7.5 7.6 7.7 5 5 5 5 6 7 9 Absolute Maximum Ratings ...................................... ESD Ratings.............................................................. Recommended Operating Conditions ...................... Thermal Information .................................................. Electrical Characteristics........................................... Timing Requirements ................................................ Typical Characteristics .............................................. Parameter Measurement Information ................ 10 Detailed Description ............................................ 12 9.1 Overview ................................................................. 12 9.2 Functional Block Diagram ....................................... 12 9.3 Feature Description................................................. 12 9.4 Device Functional Modes........................................ 15 9.5 Programming........................................................... 15 9.6 Register Maps ......................................................... 22 10 Application and Implementation........................ 30 10.1 Application Information.......................................... 30 10.2 Typical Application ................................................ 31 11 Power Supply Recommendations ..................... 33 12 Layout................................................................... 33 12.1 Layout Guidelines ................................................. 33 12.2 Layout Example .................................................... 33 12.3 Thermal Considerations ........................................ 34 13 Device and Documentation Support ................. 35 13.1 13.2 13.3 13.4 13.5 Documentation Support ....................................... Community Resources.......................................... Trademarks ........................................................... Electrostatic Discharge Caution ............................ Glossary ................................................................ 35 35 35 35 35 14 Mechanical, Packaging, and Orderable Information ........................................................... 35 4 Revision History NOTE: Page numbers for previous revisions may differ from page numbers in the current version. Changes from Original (March 2016) to Revision A • 2 Page Changed device status from Product Preview to Production Data ....................................................................................... 1 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 5 Description (continued) The individual PWM controller allows each LED to be set to a specific brightness value. An additional 8-bit resolution (256 steps) group PWM controller has both a fixed frequency of 190-Hz and an adjustable frequency between 24-Hz to once every 10.73 seconds, with a duty cycle that is adjustable from 0% to 99.6%. The group PWM controller dims or blinks all LEDs with the same value. Each LED output can be off, on (no PWM control), or set at its individual PWM controller value at both individual and group PWM controller values. The TLC59116-Q1 operates with a supply voltage range of 3 V to 5.5 V and the outputs are 17 V tolerant. LEDs can be directly connected to the TLC59116-Q1 device outputs. Software programmable LED Group and three Sub Call I2C-Bus addresses allow all or defined groups of TLC59116-Q1 devices to respond to a common I2C Bus address, allowing for example, all the same color LEDs to be turned on or off at the same time or marquee chasing effect, thus minimizing I2C Bus commands. Four hardware address pins allow up to 14 devices on the same Bus. The Software Reset (SWRST) Call allows the master to perform a reset of the TLC59116-Q1 through the I2C Bus, identical to the Power-On Reset (POR) that initializes the registers to their default state causing the outputs to be set high (LED off). This allows an easy and quick way to reconfigure all device registers to the same condition. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 3 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 6 Pin Configuration and Functions PW Package 28-Pin TSSOP Top View REXT 1 28 VCC A0 2 27 SDA A1 3 26 SCL A2 4 25 RESET A3 5 24 GND OUT0 6 23 OUT15 OUT1 7 22 OUT14 OUT2 8 21 OUT13 OUT3 9 20 OUT12 GND 10 19 GND OUT4 11 18 OUT11 OUT5 12 17 OUT10 OUT6 13 16 OUT9 OUT7 14 15 OUT8 Pin Functions PIN I/O (1) DESCRIPTION NO. NAME 1 REXT I Input terminal used to connect an external resistor for setting up all output currents 2 A0 I Address input 0 3 A1 I Address input 1 4 A2 I Address input 2 5 A3 I Address input 3 6 OUT0 O Constant current output 0 7 OUT1 O Constant current output 1 8 OUT2 O Constant current output 2 9 OUT3 O Constant current output 3 10 GND — Ground 11 OUT4 O Constant current output 4 12 OUT5 O Constant current output 5 13 OUT6 O Constant current output 6 14 OUT7 O Constant current output 7 15 OUT8 O Constant current output 8 16 OUT9 O Constant current output 9 17 OUT10 O Constant current output 10 18 OUT11 O Constant current output 11 19 GND — Ground 20 OUT12 O Constant current output 12 21 OUT13 O Constant current output 13 22 OUT14 O Constant current output 14 23 OUT15 O Constant current output 15 24 GND — Ground 25 RESET I Active-low reset input Serial clock input 26 SCL I 27 SDA I/O Serial data input/output 28 VCC — Power supply (1) 4 I/O = input and Output Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 7 Specifications 7.1 Absolute Maximum Ratings over operating free-air temperature (unless otherwise noted) (1) MIN MAX UNIT 0 7 V V VCC Supply voltage VI Input voltage –0.4 VCC + 0.4 VO Output voltage –0.5 20 V IO Output current per channel 120 mA TJ Junction temperature –40 150 °C Tstg Storage temperature –55 150 °C (1) Stresses beyond those listed under Absolute Maximum Ratings may cause permanent damage to the device. These are stress ratings only, which do not imply functional operation of the device at these or any other conditions beyond those indicated under Recommended Operating Conditions. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability. 7.2 ESD Ratings VALUE V(ESD) (1) Electrostatic discharge Human-body model (HBM), per AEC Q100-002 (1) ±2000 Charged-device model (CDM), per AEC Q100-011 ±1500 UNIT V AEC Q100-002 indicates that HBM stressing shall be in accordance with the ANSI/ESDA/JEDEC JS-001 specification. 7.3 Recommended Operating Conditions All unused inputs of the device must be held at VCC or GND to ensure proper device operation VCC Supply voltage VIH High-level input voltage SCL, SDA, RESET, A0, A1, A2, A3 VIL Low-level input voltage SCL, SDA, RESET, A0, A1, A2, A3 VO Supply voltage to output pins OUT0 to OUT15 IOL Low-level output current sink SDA IO Output current per channel OUT0 to OUT15 TA Operating free-air temperature MIN MAX 3 5.5 V 0.7 × VCC VCC V 0 0.3 × VCC V 17 V VCC = 3 V 20 VCC = 5 V 30 UNIT mA 5 120 mA –40 105 °C 7.4 Thermal Information TLC59116-Q1 THERMAL METRIC (1) PW (TSSOP) UNIT 28 PINS RθJA Junction-to-ambient thermal resistance 78 °C/W RθJC(top) Junction-to-case (top) thermal resistance RθJB Junction-to-board thermal resistance 18.8 °C/W 36 ψJT °C/W Junction-to-top characterization parameter 0.5 °C/W ψJB Junction-to-board characterization parameter 35.5 °C/W RθJC(bot) Junction-to-case (bottom) thermal resistance n/a °C/W (1) For more information about traditional and new thermal metrics, see the Semiconductor and IC Package Thermal Metrics application report, SPRA953. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 5 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 7.5 Electrical Characteristics VCC = 3 V to 5.5 V, TA = –40°C to +105°C (unless otherwise noted) PARAMETER II VPOR TEST CONDITIONS Input / output leakage current SCL, SDA, A0, A1, A2, A3, RESET Output leakage current OUT0 to OUT15 VO = 17 V, TJ = 25°C MIN TYP (1) VI = VCC or GND Power-on reset voltage MAX UNIT ±0.3 μA 0.5 μA 2.5 VCC = 3 V, VOL = 0.4 V 20 VCC = 5 V, VOL = 0.4 V 30 V IOL Low-level output current SDA IO(1) Output current 1 OUT0 to OUT15 VO = 0.6 V, Rext = 720 Ω, CG = 0.992 Output current error I = 26 mA, VO = 0.6 V, Rext = 720 Ω, OUT0 to OUT15 O TJ = 25°C ±10% Output channel to channel current error OUT0 to OUT15 IO = 26 mA, VO = 0.6 V, Rext = 720 Ω, TJ = 25°C ±6% Output current 2 OUT0 to OUT15 VO = 0.8 V, Rext = 360 Ω, CG = 0.992 Output current error I = 52 mA, VO = 0.8 V, Rext = 360 Ω, OUT0 to OUT15 O TJ = 25°C ±8% Output channel to channel current error OUT0 to OUT15 IO = 52 mA, VO = 0.8 V, Rext = 360 Ω, TJ = 25°C ±6% IOUT vs VOUT Output current vs output voltage regulation OUT0 to OUT15 IOUT,Th1 Threshold current 1 for error detection OUT0 to OUT15 IOUT,target = 26 mA 0.5 × ITARGET% IOUT,Th2 Threshold current 2 for error detection OUT0 to OUT15 IOUT,target = 52 mA 0.5 × ITARGET% IOUT,Th3 Threshold current 3 for error detection OUT0 to OUT15 IOUT,target = 104 mA 0.5 × ITARGET% TSD Overtemperature shutdown THYS Restart hysteresis IO(2) Input capacitance Cio Input / output capacitance SDA 6 Supply current mA 52 VO = 1 V to 3 V, IO = 26 mA mA ±0.1 VO = 3 V to 5.5 V, IO = 26 mA to 120 mA %/V ±1 150 Ci (1) (2) (3) 26 (2) (3) SCL, A0, A1, A2, A3, RESET ICC (2) mA 175 200 °C 15 °C VI = VCC or GND 5 pF VI = VCC or GND 8 pF VCC = 5.5 V OUT0 to OUT15 = OFF, Rext = Open 25 OUT0 to OUT15 = OFF, Rext = 720 Ω 29 OUT0 to OUT15 = OFF, Rext = 360 Ω 32 OUT0 to OUT15 = OFF, Rext = 180 Ω 37 OUT0 to OUT15 = ON, Rext = 720 Ω 29 OUT0 to OUT15 = ON, Rext = 360 Ω 32 OUT0 to OUT15 = ON, Rext = 180 Ω 37 mA All typical values are at TA = 25°C. CG is the Current Gain and is defined in Table 13. Specified by design Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 7.6 Timing Requirements TA = –40°C to +105°C I2C BUS MIN MAX STANDARD MODE 0 100 FAST MODE 0 400 FAST MODE PLUS 0 1000 STANDARD MODE 4.7 FAST MODE 1.3 FAST MODE PLUS 0.5 UNIT 2 I C INTERFACE fSCL SCL clock frequency (1) I2C Bus free time between Stop and Start conditions tBUF STANDARD MODE tHD;STA tSU;STA tSU;STO tHD;DAT tVD;ACK tVD;DAT tSU;DAT tLOW Hold time (repeated) Start condition Set-up time for a repeated Start condition Set-up time for Stop condition Data hold time Data valid acknowledge time Data valid time (2) (3) Data set-up time Low period of SCL clock High period of SCL clock 0.6 FAST MODE PLUS 0.26 STANDARD MODE 4.7 FAST MODE 0.6 FAST MODE PLUS 0.26 STANDARD MODE 4 FAST MODE 0.6 FAST MODE PLUS 0.26 STANDARD MODE 0 FAST MODE 0 FAST MODE PLUS 0 STANDARD MODE 0.3 Fall time of both SDA and SCL signals (4) (5) (5) (6) ns 3.45 0.1 0.9 0.45 STANDARD MODE 0.3 3.45 FAST MODE 0.1 0.9 0.45 FAST MODE PLUS 0.05 STANDARD MODE 250 FAST MODE 100 FAST MODE PLUS 50 STANDARD MODE 4.7 FAST MODE 1.3 FAST MODE PLUS 0.5 0.6 FAST MODE PLUS 0.26 FAST MODE FAST MODE μs μs ns μs 4 FAST MODE FAST MODE PLUS (1) (2) (3) (4) μs 0.05 μs 300 20+0.1Cb (6) 300 ns 120 STANDARD MODE Rise time of both SDA and SCL signals μs FAST MODE FAST MODE PLUS tr μs FAST MODE PLUS STANDARD MODE tf μs 4 FAST MODE STANDARD MODE tHIGH kHz 1000 20+0.1Cb (6) 300 ns 120 The TLC59116-Q1 does not have a self timeout on the I2C Bus. The Master can issue a reset if needed. tVD;ACK = time for ACK signal from SCL low to SDA (out) low. tVD;DAT = minimum time for SDA data out to be valid following SCL low. A master device must internally provide a hold time of at least 300 ns for the SDA signal (refer to the VIL of the SCL signal) in order to bridge the undefined region of the SCL falling edge. The maximum tf for the SDA and SCL bus lines is specified at 300 ns. The maximum fall time (tf) for the SDA output stage is specified at 250 ns. This allows series protection resistors to be connected between the SDA and the SCL pins and the SDA/SCL bus lines without exceeding the maximum specified tf. Cb = Total capacitance of one bus line in pF Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 7 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com Timing Requirements (continued) TA = –40°C to +105°C I2C BUS Pulse width of spikes that must be suppressed by the input filter (7) tSP MIN MAX STANDARD MODE 50 FAST MODE 50 FAST MODE PLUS 50 UNIT ns RESET tW Reset pulse width tREC Reset recovery time tRESET (7) (8) (9) 8 Time to reset (8) (9) STANDARD MODE 10 FAST MODE 10 FAST MODE PLUS 10 STANDARD MODE 0 FAST MODE 0 FAST MODE PLUS 0 STANDARD MODE 400 FAST MODE 400 FAST MODE PLUS 400 ns ns ns Input filters on the SDA and SCL inputs suppress noise spikes less than 50 ns. Resetting the device while actively communicating on the bus may cause glitches or errant Stop conditions. Upon reset, the full delay will be the sum of tRESET and the RC time constant of the SDA bus. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 7.7 Typical Characteristics 125 140 156 : 720 : 3750 : 120 Output Current (mA) Output Current, Iout (A) 100 100 80 60 40 75 50 25 20 0 0 500 1000 1500 2000 2500 3000 3500 0 4000 0 0.2 0.4 Rext (W) VCC = 5 V Figure 1. IOUT,target vs Rext 0.6 0.8 1 Output Voltage (V) 1.2 1.4 1.5 D002 CG = 0.992 Figure 2. Output Current vs Output Voltage across Output Current 24 28 24 Supply Current (mA) Output Current (mA) 22 20 16 12 8 -40 qC 25 qC 85 qC 105 qC 4 20 18 -40 qC 25 qC 85 qC 105 qC 16 14 0 0 0.2 VCC = 5 V 0.4 0.6 0.8 1 Output Voltage (V) CG = 0.992 1.2 1.4 1.5 3 3.25 3.5 D003 REXT = 720 Ω REXT = 720 Ω Figure 3. Output Current vs Output Voltage across Temp 3.75 4 4.25 4.5 4.75 Supply Voltage (V) 5 5.25 Product Folder Links: TLC59116-Q1 D004 All Channels ON Figure 4. ICC vs VCC across Temp Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated 5.5 9 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 8 Parameter Measurement Information Start SCL ACK or Read Cycle SDA 30% tRESET 50% RESET tREC tW OUTn 50% tRESET Figure 5. Reset Timing SDA tBUF tHD;STA tr tSP tf tLOW SCL tSU;DAT tHD;STA P tHD;DAT S tHIGH tSU;DAT tSU;STO Sr P Figure 6. Definition of Timing Protocol START Condition (S) Bit 7 MSB (A7) tSU;STA tLOW Bit 6 (A6) tHIGH Bit 7 (D1) Bit 8 (D0) Acknowledge (A) STOP Condition (P) 1/fSCL SCL tr tf tBUF SDA tHD;STA tHD;DAT tSU;DAT tVD;DAT tVD;ACK TSU;STO NOTE: Rise and fall times refer to VIL and VIH. Figure 7. I2C Bus Timing 10 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 Parameter Measurement Information (continued) VCC RL Pulse Generator VI DUT RT VCC Open GND VO CL NOTE: • RL = Load resistance for SDA and SCL; should be >1 kΩ at 3-mA or lower current • CL = Load capacitance; includes jig and probe capacitance • RT = Termination resistance; should be equal to the output impedance (ZO) of the pulse generator Figure 8. Test Circuit for Switching Characteristics Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 11 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 9 Detailed Description 9.1 Overview The TLC59116-Q1 is an I2C Bus controlled 16-channel LED driver that is optimized for red/green/blue/amber (RGBA) color mixing and backlight application. Each LED output has its own 8-bit resolution (256 steps) fixedfrequency individual PWM controller that operates at 97-kHz, with a duty cycle that is adjustable from 0% to 99.6%. The individual PWM controller allows each LED to be set to a specific brightness value. An additional 8bit resolution (256 steps) group PWM controller has both a fixed frequency of 190-Hz and an adjustable frequency between 24-Hz to once every 10.73 seconds, with a duty cycle that is adjustable from 0% to 99.6%. The group PWM controller dims or blinks all LEDs with the same value. 9.2 Functional Block Diagram A0 A1 A2 A3 SCL SDA Input Filter REXT OUT0 OUT1 OUT14 OUT15 I/O Regulator 2 I C Bus Control Output Driver and Error Detection RESET Power-On Reset Control LED State Select Register PWM Register X Brightness Control 97 kHz 24.3 kHz 25-MHz Oscillator VCC GRPFRQ Register GRPPWM Register 190 kHz 0 = Permanently off 1 = Permanently on GND 9.3 Feature Description 9.3.1 Open-Circuit Detection The TLC59116-Q1 LED open-circuit detection compares the effective current level IOUT with the open load detection threshold current IOUT,Th. If IOUT is below the threshold IOUT,Th the TLC59116-Q1 detects an open load condition. This error status can be read out as an error flag through the registers EFLAG1 and EFLAG2. For open-circuit error detection, a channel must be on and the PWM must be off. See Table 1. 12 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 Feature Description (continued) Table 1. Open-Circuit Detection STATE OF OUTPUT PORT CONDITION OF OUTPUT CURRENT ERROR STATUS CODE MEANING Off IOUT = 0 mA On (1) 0 Detection not possible IOUT < IOUT,Th (1) 0 Open circuit IOUT ≥ IOUT,Th (1) Channel n error status bit 1 Normal IOUT,Th = 0.5 × IOUT,target (typical) 9.3.2 Overtemperature Detection and Shutdown The TLC59116-Q1 LED is equipped with a global overtemperature sensor and 16 individual channel-selective overtemperature sensors. • When the global sensor reaches the trip temperature, all output channels are shut down, and the error status is stored in the internal Error Status register of every channel. After shutdown, the channels automatically restart after cooling down, if the control signal (output latch) remains on. The stored error status is not reset after cooling down and can be read out as the error status code in registers EFLAG1 and EFLAG2. • When one of the channel-specific sensors reaches trip temperature, only the affected output channel is shut down, and the error status is stored only in the internal Error Status register of the affected channel. After shutdown, the channel automatically restarts after cooling down, if the control signal (output latch) remains on. The stored error status is not reset after cooling down and can be read out as error status code in registers EFLAG1 and EFLAG2. For channel-specific overtemperature error detection, a channel must be on. The error flags of open-circuit and overtemperature are ORed to set the EFLAG1 and EFLAG2 registers. The error status code because of overtemperature is reset when the host writes 1 to bit 7 of the MODE2 register. The host must write 0 to bit 7 of the MODE2 register to enable the overtemperature error flag. See Table 2. Table 2. Overtemperature Detection (1) (1) STATE OF OUTPUT PORT CONDITION ERROR STATUS CODE MEANING On On → all channels Off Tj < Tj,trip global 1 Normal Tj > Tj,trip global All error status bits = 0 Global overtemperature On On → Off Tj < Tj,trip channel n 1 Normal Tj > Tj,trip channel n Channel n error status bit = 0 Channel n overtemperature The global shutdown threshold temperature is approximately 170°C. 9.3.3 Power-On Reset (POR) When power is applied to VCC, an internal power-on reset holds the TLC59116-Q1 in a reset condition until VCC reaches VPOR. At this point, the reset condition is released and the TLC59116-Q1 registers, and I2C Bus state machine are initialized to their default states (all zeroes), causing all the channels to be deselected. Thereafter, VCC must be lowered below 0.2 V to reset the device. 9.3.4 External Reset A reset can be accomplished by holding the RESET pin low for a minimum of tW. The TLC59116-Q1 registers and I2C state machine are held in their default states until the RESET input is again high. This input requires a pullup resistor to VCC if no active connection is used. 9.3.5 Software Reset The Software Reset Call (SWRST Call) allows all the devices in the I2C Bus to be reset to the power-up state value through a specific I2C Bus command. The SWRST Call function is defined as the following: 1. A Start command is sent by the I2C Bus master. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 13 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 2. The reserved SWRST I2C Bus address 1101 011 with the R/W bit set to 0 (write) is sent by the I2C Bus master. 3. The TLC59116-Q1 device(s) acknowledge(s) after seeing the SWRST Call address 1101 0110 (D6h) only. If the R/W bit is set to 1 (read), no acknowledge is returned to the I2C Bus master. 4. Once the SWRST Call address has been sent and acknowledged, the master sends two bytes with two specific values (SWRST data byte 1 and byte 2): (a) Byte1 = A5h: the TLC59116-Q1 acknowledges this value only. If byte 1 is not equal to A5h, the TLC59116-Q1 does not acknowledge it. (b) Byte 2 = 5Ah: the TLC59116-Q1 acknowledges this value only. If byte 2 is not equal to 5Ah, the TLC59116-Q1 does not acknowledge it. If more than two bytes of data are sent, the TLC59116-Q1 does not acknowledge any more. 5. Once the correct two bytes (SWRST data byte 1 and byte 2 only) have been sent and correctly acknowledged, the master sends a Stop command to end the SWRST Call. The TLC59116-Q1 then resets to the default value (power-up value) and is ready to be addressed again within the specified bus free time (tBUF). The I2C Bus master may interpret a non-acknowledge from the TLC59116-Q1 (at any time) as a SWRST Call Abort. The TLC59116-Q1 does not initiate a reset of its registers. This happens only when the format of the Start Call sequence is not correct. 9.3.6 Individual Brightness Control With Group Dimming/Blinking A 97-kHz fixed-frequency signal with programmable duty cycle (8 bits, 256 steps) is used to control the individual brightness for each LED. On top of this signal, one of the following signals can be superimposed (this signal can be applied to the four LED outputs): • A lower 190-Hz fixed-frequency signal with programmable duty cycle (8 bits, 256 steps) provides a global brightness control. • A programmable frequency signal from 24-Hz to 1/10.73 s (8 bits, 256 steps) provides a global blinking control. See Figure 9. 14 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 6 7 8 6 7 8 9 5 5 10 3 4 3 4 1 2 1 2 512 510 511 509 507 508 11 12 9 10 8 6 7 5 SLDS223A – MARCH 2016 – REVISED MARCH 2016 4 3 2 1 www.ti.com N × 40 ns with N = 0 to 255 (PWM register) M × 256 × 2 × 40 ns with M = 0 to 255 (GRPPWM register) 256 × 40 ns = 10.24 µs (97.6 kHz) Group Dimming Signal 256 × 2 × 256 × 40 ns = 5.24 ms (190.7 Hz) Resulting Brightness + Group Dimming Signal NOTE: • Minimum pulse width for LEDn brightness control is 40 ns. • Minimum pulse width for group dimming is 20.48 μs. • When M = 1 (GRPPWM register value), the resulting LEDn Brightness Control + Group Dimming signal has two pulses of the LED Brightness Control signal (pulse width = n × 40 ns, with n defined in the PWMx register). • This resulting Brightness + Group Dimming signal shows a resulting control signal with M = 4 (8 pulses). Figure 9. Brightness and Group Dimming Signals 9.4 Device Functional Modes 9.4.1 Active Active mode occurs when one or more of the output channels is enabled. 9.4.2 Standby Standby mode occurs when all output channels are disabled. Standby mode may be entered via I2C command or by pulling the RESET pin low. 9.5 Programming 9.5.1 Characteristics of the I2C Bus The I2C Bus is for two-way two-line communication between different devices or modules. The two lines are a serial data line (SDA) and a serial clock line (SCL). Both lines must be connected to a positive supply via a pullup resistor when connected to the output stages of a device. Data transfer may be initiated only when the bus is not busy. 9.5.1.1 Bit Transfer One data bit is transferred during each clock pulse. The data on the SDA line must remain stable during the high period of the clock pulse as changes in the data line at this time will be interpreted as control signals (see Figure 10). Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 15 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com Programming (continued) SDA SCL Data Line Stable; Data Valid Change of Data Allowed Figure 10. Bit Transfer 9.5.1.2 Start and Stop Conditions Both data and clock lines remain high when the bus is not busy. A high-to-low transition of the data line while the clock is high is defined as the Start condition (S). A low-to-high transition of the data line while the clock is high is defined as the Stop condition (P) (see Figure 11). SDA SCL S P Start Condition Stop Condition Figure 11. Start and Stop Conditions 9.5.1.3 Acknowledge The number of data bytes transferred between the Start and the Stop conditions from transmitter to receiver is not limited. Each byte of eight bits is followed by one acknowledge bit. The acknowledge bit is a high level put on the bus by the transmitter, whereas the master generates an extra acknowledge related clock pulse. See Figure 12. A slave receiver that is addressed must generate an acknowledge after the reception of each byte. Also a master must generate an acknowledge after the reception of each byte that has been clocked out of the slave transmitter. The device that acknowledges has to pull down the SDA line during the acknowledge clock pulse, so that the SDA line is stable low during the high period of the acknowledge related clock pulse; set-up time and hold time must be taken into account. A master receiver must signal an end of data to the transmitter by not generating an acknowledge on the last byte that has been clocked out of the slave. In this event, the transmitter must leave the data line high to enable the master to generate a Stop condition. See Figure 13. 16 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 Programming (continued) Data Output by Transmitter NACK Data Output by Receiver ACK SCL From Master 1 2 8 9 S Start Condition Clock Pulse for Acknowledgment Figure 12. Acknowledge/Not Acknowledge on I2C Bus Slave Address 1 S 1 Control Register 0 A3 A2 A1 A0 0 Start Condition X X A X D4 D3 D2 D1 D0 A R/W ACK From Slave A ACK From Slave P Stop Condition Auto-Increment Options Auto-Increment Flag ACK From Slave Figure 13. Write to a Specific Register Slave Address S 1 1 Control Register 0 A3 A2 A1 A0 0 Start Condition A 1 0 0 0 0 0 MODE2 Register MODE1 Register 0 0 R/W A A ACK From Slave A ACK From Slave MODE1 Register Selection Auto-Increment On All Registers (see Note A) Auto-Increment On ACK From Slave SUBADR3 Register ALLCALLADR Register A ACK From Slave A ACK From Slave P Stop Condition See Table 4 for register definitions. Figure 14. Write to All Registers Using Auto-Increment Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 17 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com Programming (continued) Slave Address Control Register S A6 A5 A4 A3 A2 A1 A0 0 Start Condition A 1 0 1 0 0 0 PWM0 Register 1 0 R/W PWM1 Register A A A ACK From Slave ACK From Slave PWM0 Register Selection Auto-Increment On Brightness Registers Only Auto-Increment On ACK From Slave PWM14 Register PWM15 Register PWM0 Register A ACK From Slave PWMx Register A A A ACK From Slave ACK From Slave ACK From Slave P Stop Condition Figure 15. Multiple Writes to Individual Brightness Registers Using Auto-Increment Slave Address Control Register S A6 A5 A4 A3 A2 A1 A0 0 Start Condition 0 1 A 0 0 0 0 R/W Data From MODE1 Register Slave Address 0 0 A Sr A6 A5 A4 A3 A2 A1 A0 1 ACK From Slave A A R/W ACK From Slave ACK From Master MODE1 Register Selection Auto-Increment On All Registers Auto-Increment On ACK From Slave Data From MODE2 Register Data From PWM0 Register A Data From ALLCALLADR Register A ACK From Master ACK From Master Data From MODE1 Register A ACK From Master A ACK From Master Data From Last Read Byte A P NACK From Master Stop Condition Figure 16. Read All Registers Auto-Increment 18 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 Programming (continued) 2 Slave Address Sequence A New LED All Call I C Address (see Note B) Control Register S A6 A5 A4 A3 A2 A1 A0 0 Start Condition A X X X 1 1 0 1 1 A 1 1 0 1 ACK From Slave R/W 0 1 1 X A ACK From Slave P Stop Condition ALLCALLADR Register Selection Auto-Increment Options Auto-Increment Flag ACK From Slave 2 LED All Call I C Address Sequence B S 1 1 0 1 1 0 Start Condition 1 The 16 LEDs are on at ACK (see Note C) LEDOUT0 Register (LED3 to 0 Fully On) Control Register 0 A X X X 1 0 1 0 R/W 0 A 0 1 0 1 0 ACK From the Four Slaves 1 0 1 A ACK From the Four Slaves P Stop Condition LEDOUT0 Register Selection ACK From Slave A. In this example, several TLC59116-Q1 devices are used, and the same Sequence A is sent to each of them. B. The ALLCALL bit in the MODE1 register is equal to 1 for this example. C. The OCH bit in the MODE2 register is equal to 1 for this example. Figure 17. LED All Call I2C Bus Address Programming and LED All Call Sequence 9.5.2 System Configuration A device generating a message is a transmitter; a device receiving is the receiver. The device that controls the message is the master and the devices that are controlled by the master are the slaves (see Figure 18). SDA SCL Master Transmitter/ Receiver Slave Receiver Slave Transmitter/ Receiver Master Transmitter Master Transmitter/ Receiver I2C Bus Multiplexer Slave Figure 18. System Configuration 9.5.3 Device Address Following a Start condition, the bus master must output the address of the slave it is accessing. 9.5.4 Regular I2C Bus Slave Address The I2C Bus slave address of the TLC59116-Q1 is shown in Figure 19. To conserve power, no internal pullup resistors are incorporated on the hardware-selectable address pins, and they must be pulled high or low. For buffer management purposes, a set of sector information data should be stored. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 19 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com Programming (continued) Slave Address 1 1 Fixed 0 A3 A2 A1 A0 R/W Hardware Selectable Figure 19. Slave Address The last bit of the address byte defines the operation to be performed. When set to logic 1, a read operation is selected. When set to logic 0, a write operation is selected. 9.5.5 LED All Call I2C Bus Address • Default power-up value (ALLCALLADR register): D0h or 1101 000 • Programmable through I2C Bus (volatile programming) • At power-up, LED All Call I2C Bus address is enabled. TLC59116-Q1 sends an ACK when D0h (R/W = 0) or D1h (R/W = 1) is sent by the master. See LED All Call I2C Bus Address Register (ALLCALLADR) for more detail. NOTE The default LED All Call I2C Bus address (D0h or 1101 000) must not be used as a regular I2C Bus slave address, since this address is enabled at power-up. All the TLC59116-Q1 devices on the I2C Bus will acknowledge the address if it is sent by the I2C Bus master. 20 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 Programming (continued) 9.5.6 LED Sub Call I2C Bus Address • Three different I2C Bus addresses can be used • Default power-up values: – SUBADR1 register: D2h or 1101 001 – SUBADR2 register: D4h or 1101 010 – SUBADR3 register: D8h or 1101 100 • Programmable through I2C Bus (volatile programming) • At power-up, Sub Call I2C Bus address is disabled. TLC59116-Q1 does not send an ACK when D2h (R/W = 0) or D3h (R/W = 1) or D4h (R/W = 0) or D5h (R/W = 1) or D8h (R/W = 0) or D9h (R/W = 1) is sent by the master. See I2C Bus Subaddress Registers 1 to 3 (SUBADR1 to SUBADR3) for more detail. NOTE The LED Sub Call I2C Bus addresses may be used as regular I2C Bus slave addresses if their corresponding enable bits are set to 0 in the MODE1 Register. 9.5.7 Software Reset I2C Bus Address The address shown in Figure 20 is used when a reset of the TLC59116-Q1 is performed by the master. The software reset address (SWRST Call) must be used with R/W = 0. If R/W = 1, the TLC59116-Q1 does not acknowledge the SWRST. See Software Reset for more detail. 1 1 0 1 0 1 1 R/W Figure 20. Software Reset Address NOTE The Software Reset I2C Bus address is reserved address and cannot be use as regular I2C Bus slave address or as an LED All Call or LED Sub Call address. 9.5.8 Control Register Following the successful acknowledgment of the slave address, LED All Call address or LED Sub Call address, the bus master sends a byte to the TLC59116-Q1, which is stored in the Control register. The lowest five bits are used as a pointer to determine which register is accessed (D[4:0]). The highest three bits are used as autoincrement flag and auto-increment options (AI[2:0]). See Figure 21. Auto-Increment Flag Register Address AI2 AI1 AI0 D4 D3 D2 D1 D0 Auto-Increment Options Figure 21. Control Register When the auto-increment flag is set (AI2 = logic 1), the five low order bits of the Control register are automatically incremented after a read or write. This allows the user to program the registers sequentially. Four different types of auto-increment are possible, depending on AI1 and AI0 values as shown in Table 3. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 21 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com Programming (continued) Table 3. Auto-Increment Options AI2 AI1 AI0 0 0 0 No auto-increment DESCRIPTION 1 0 0 Auto-increment for all registers. D[4:0] roll over to 0 0000 after the last register (1 1011) is accessed. 1 0 1 Auto-increment for individual brightness registers only. D[4:0] roll over to 0 0010 after the last register (1 0001) is accessed. 1 1 0 Auto-increment for global control registers only. D[4:0] roll over to 1 0010 after the last register (1 0011) is accessed. 1 1 1 Auto-increment for individual and global control registers only. D[4:0] roll over to 0 0010 after the last register (1 0011) is accessed. NOTE Other combinations are not shown in Table 3. (AI[2:0] = 001, 010, and 011) are reserved and must not be used for proper device operation. AI[2:0] = 000 is used when the same register must be accessed several times during a single I2C Bus communication, for example, changing the brightness of a single LED. Data is overwritten each time the register is accessed during a write operation. AI[2:0] = 100 is used when all the registers must be sequentially accessed, for example, power-up programming. AI[2:0] = 101 is used when the four LED drivers must be individually programmed with different values during the same I2C Bus communication, for example, changing a color setting to another color setting. AI[2:0] = 110 is used when the LED drivers must be globally programmed with different settings during the same I2C Bus communication, for example, global brightness or blinking change. AI[2:0] = 111 is used when individually and global changes must be performed during the same I2C Bus communication, for example, changing color and global brightness at the same time. Only the five least significant bits D[4:0] are affected by the AI[2:0] bits. When the Control register is written, the register entry point determined by D[4:0] is the first register that will be addressed (read or write operation), and can be anywhere between 0 0000 and 1 1011 (as defined in Table 4). When AI[2] = 1, the Auto-Increment flag is set and the rollover value at which the point where the register increment stops and goes to the next one is determined by AI[2:0]. See Table 3 for rollover values. For example, if the Control register = 1111 0100 (F4h), then the register addressing sequence will be (in hex): 14 → ... → 1B → 00 → ... → 13 → 02 → ... → 13 → 02 → ... as long as the master keeps sending or reading data. 9.6 Register Maps Table 4 describes the registers in the TLC59116-Q1. Table 4. Register Descriptions REGISTER NUMBER (HEX) (1) 22 NAME ACCESS (1) DESCRIPTION 00 MODE1 R/W Mode 1 01 MODE2 R/W Mode 2 02 PWM0 R/W Brightness control LED0 03 PWM1 R/W Brightness control LED1 04 PWM2 R/W Brightness control LED2 05 PWM3 R/W Brightness control LED3 06 PWM4 R/W Brightness control LED4 R = read, W = write Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 Register Maps (continued) Table 4. Register Descriptions (continued) REGISTER NUMBER (HEX) NAME ACCESS (1) DESCRIPTION 07 PWM5 R/W Brightness control LED5 08 PWM6 R/W Brightness control LED6 09 PWM7 R/W Brightness control LED7 0A PWM8 R/W Brightness control LED8 0B PWM9 R/W Brightness control LED9 0C PWM10 R/W Brightness control LED10 0D PWM11 R/W Brightness control LED11 0E PWM12 R/W Brightness control LED12 0F PWM13 R/W Brightness control LED13 10 PWM14 R/W Brightness control LED14 11 PWM15 R/W Brightness control LED15 12 GRPPWM R/W Group duty cycle control 13 GRPFREQ R/W Group frequency 14 LEDOUT0 R/W LED output state 0 15 LEDOUT1 R/W LED output state 1 16 LEDOUT2 R/W LED output state 2 17 LEDOUT3 R/W LED output state 3 18 SUBADR1 R/W I2C Bus subaddress 1 19 SUBADR2 R/W I2C Bus subaddress 2 1A SUBADR3 R/W I2C Bus subaddress 3 1B ALLCALLADR R/W LED All Call I2C Bus address 1C IREF R/W IREF configuration 1D EFLAG1 R Error flags 1 1E EFLAG2 R Error flags 2 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 23 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 9.6.1 Mode Register 1 (MODE1) Table 5 describes Mode Register 1. Table 5. MODE1 – Mode Register 1 (Address 00h) Bit Description BIT 7 6 AI2 AI1 ACCESS R 4 OSC R/W SUB2 R/W 1 SUB3 R/W 0 ALLCALL R/W (2) 1 0 0 DESCRIPTION Register auto-increment disabled Register auto-increment enabled (2) 1 R/W 2 VALUE 0 R AI0 SUB1 (1) R 5 3 (1) (2) (3) SYMBOL Auto-increment bit 1 = 0 Auto-increment bit 1 = 1 (2) Auto-increment bit 0 = 0 1 Auto-increment bit 0 = 1 0 Normal mode (3) 1 (2) Oscillator off. 0 (2) Device does not respond to I2C Bus subaddress 1. Device responds to I2C Bus subaddress 1. 1 0 (2) Device responds to I2C Bus subaddress 2. 1 0 1 Device does not respond to I2C Bus subaddress 2. (2) Device does not respond to I2 CBus subaddress 3. 1 Device responds to I2C Bus subaddress 3. 0 Device does not respond to LED All Call I2C Bus address. (2) Device responds to LED All Call I2C Bus address. R = read, W = write Default value Requires 500 μs maximum for the oscillator to be up and running once OSC bit has been set to logic 1. Timings on LED outputs are not ensured if PWMx, GRPPWM, or GRPFREQ registers are accessed within the 500-μs window. NOTE The OSC bit (Bit 4) must be set to 0 before any outputs will turn on. Proper operation requires this bit to be 0. Setting the bit to a 1 will turn all channels off. 9.6.2 Mode Register 2 (MODE2) Table 6 describes Mode Register 2. Table 6. MODE2 – Mode Register 2 (Address 01h) Bit Description BIT 7 SYMBOL EFCLR 6 5 2:0 (1) (2) (3) 24 R/W R DMBLNK 4 3 ACCESS R/W R OCH R/W R (1) VALUE 0 (2) 1 DESCRIPTION Enable error status flag Clear error status flag 0 (2) Reserved 0 (2) Group control = dimming 1 Group control = blinking 0 (2) Reserved 0 (2) Outputs change on Stop command 1 000 (3) Outputs change on ACK (2) Reserved R = read, W = write Default value Change of the outputs at the Stop command allows synchronizing outputs of more than one TLC59116-Q1. Applicable to registers from 02h (PWM0) to 17h (LEDOUT3) only. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 9.6.3 Brightness Control Registers 0 to 15 (PWM0 to PWM15) Table 7 describes Brightness Control Registers 0 to 15. Table 7. PWM0 to PWM15 – Brightness Control Registers 0 to 15 (Address 02h to 11h) Bit Description REGISTER BIT SYMBOL 02h PWM0 7:0 IDC0[7:0] R/W 0000 0000 (2) PWM0 individual duty cycle 03h PWM1 7:0 IDC1[7:0] R/W 0000 0000 (2) PWM1 individual duty cycle PWM2 individual duty cycle (1) (2) ACCESS (1) ADDRESS VALUE DESCRIPTION 04h PWM2 7:0 IDC2[7:0] R/W 0000 0000 (2) 05h PWM3 7:0 IDC3[7:0] R/W 0000 0000 (2) PWM3 individual duty cycle 06h PWM4 7:0 IDC4[7:0] R/W 0000 0000 (2) PWM4 individual duty cycle 07h PWM5 7:0 IDC5[7:0] R/W 0000 0000 (2) PWM5 individual duty cycle PWM6 individual duty cycle 08h PWM6 7:0 IDC6[7:0] R/W 0000 0000 (2) 09h PWM7 7:0 IDC7[7:0] R/W 0000 0000 (2) PWM7 individual duty cycle 0Ah PWM8 7:0 IDC8[7:0] R/W 0000 0000 (2) PWM8 individual duty cycle PWM9 individual duty cycle 0Bh PWM9 7:0 IDC9[7:0] R/W 0000 0000 (2) 0Ch PWM10 7:0 IDC10[7:0] R/W 0000 0000 (2) PWM10 individual duty cycle 0Dh PWM11 7:0 IDC11[7:0] R/W 0000 0000 (2) PWM11 individual duty cycle PWM12 individual duty cycle 0Eh PWM12 7:0 IDC12[7:0] R/W 0000 0000 (2) 0Fh PWM13 7:0 IDC13[7:0] R/W 0000 0000 (2) PWM13 individual duty cycle 10h PWM14 7:0 IDC14[7:0] R/W 0000 0000 (2) PWM14 individual duty cycle 11h PWM15 7:0 IDC15[7:0] R/W 0000 0000 (2) PWM15 individual duty cycle R = read, W = write Default value A 97-kHz fixed frequency signal is used for each output. Duty cycle is controlled through 256 linear steps from 00h (0% duty cycle = LED output off) to FFh (99.6% duty cycle = LED output at maximum brightness). Applicable to LED outputs programmed with LDRx = 10 or 11 (LEDOUT0, LEDOUT1, LEDOUT2 and LEDOUT3 registers). Duty cycle = IDCn[7:0] / 256 (1) 9.6.4 Group Duty Cycle Control Register (GRPPWM) Table 8 describes the Group Duty Cycle Control Register. Table 8. GRPPWM – Group Brightness Control Register (Address 12h) Bit Description ADDRESS REGISTER BIT SYMBOL 12h GRPPWM 7:0 GDC0[7:0] (1) (2) ACCESS R/W (1) VALUE 1111 1111 DESCRIPTION (2) GRPPWM register R = read, W = write Default value When the DMBLNK bit (MODE2 register) is programmed with logic 0, a 190-Hz fixed-frequency signal is superimposed with the 97-kHz individual brightness control signal. GRPPWM is then used as a global brightness control, allowing the LED outputs to be dimmed with the same value. The value in GRPFREQ is then a Don't care. General brightness for the 16 outputs is controlled through 256 linear steps from 00h (0% duty cycle = LED output off) to FFh (99.6% duty cycle = maximum brightness). This is applicable to LED outputs programmed with LDRx = 11 (LEDOUT0, LEDOUT1, LEDOUT2 and LEDOUT3 registers). When DMBLNK bit is programmed with logic 1, the GRPPWM and GRPFREQ registers define a global blinking pattern, where GRPFREQ defines the blinking period (from 24-Hz to 10.73 s) and GRPPWM defines the duty cycle (ON/OFF ratio in %). Duty cycle = GDC0[7:0] / 256 (2) Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 25 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 9.6.5 Group Frequency Register (GRPFREQ) Table 9 describes the Group Frequency Register. Table 9. GRPFREQ – Group Frequency Register (Address 13h) Bit Description ADDRESS REGISTER BIT SYMBOL 13h GRPFREQ 7:0 GFRQ[7:0] (1) (2) ACCESS (1) R/W VALUE 0000 0000 DESCRIPTION (2) GRPFREQ register R = read, W = write Default value GRPFREQ is used to program the global blinking period when the DMBLNK bit (MODE2 register) is equal to 1. Value in this register is a Don't care when DMBLNK = 0. This is applicable to LED output programmed with LDRx = 11 (LEDOUT0, LEDOUT1, LEDOUT2 and LEDOUT3 registers). The blinking period is controlled through 256 linear steps from 00h (41 ms, frequency 24 Hz) to FFh (10.73 s). Global blinking period (seconds) = (GFRQ[7:0] + 1) / 24 9.6.6 LED Driver Output State Registers 0 to 3 (LEDOUT0 to LEDOUT3) Table 10 describes LED Driver Output State Registers 0 to 3. Table 10. LEDOUT0 to LEDOUT3 – LED Driver Output State Registers 0 to 3 (Address 14h to 17h) Bit Description ADDRESS 14h 15h 16h 17h (1) (2) REGISTER LEDOUT0 LEDOUT1 LEDOUT2 LEDOUT3 ACCESS (1) BIT SYMBOL 7:6 LDR3[1:0] R/W VALUE 00 (2) LED3 output state control DESCRIPTION 5:4 LDR2[1:0] R/W 00 (2) LED2 output state control 3:2 LDR1[1:0] R/W 00 (2) LED1 output state control 1:0 LDR0[1:0] R/W 00 (2) LED0 output state control LED7 output state control 7:6 LDR7[1:0] R/W 00 (2) 5:4 LDR6[1:0] R/W 00 (2) LED6 output state control 3:2 LDR5[1:0] R/W 00 (2) LED5 output state control LED4 output state control 1:0 LDR4[1:0] R/W 00 (2) 7:6 LDR11[1:0] R/W 00 (2) LED11 output state control 5:4 LDR10[1:0] R/W 00 (2) LED10 output state control 3:2 LDR9[1:0] R/W 00 (2) LED9 output state control LED8 output state control 1:0 LDR8[1:0] R/W 00 (2) 7:6 LDR15[1:0] R/W 00 (2) LED15 output state control 5:4 LDR14[1:0] R/W 00 (2) LED14 output state control LED13 output state control LED12 output state control 3:2 LDR13[1:0] R/W 00 (2) 1:0 LDR12[1:0] R/W 00 (2) R = read, W = write Default value LDRx = 00: LED driver x is off (default power-up state). LDRx = 01: LED driver x is fully on (individual brightness and group dimming/blinking not controlled). LDRx = 10: LED driver x is individual brightness can be controlled through its PWMx register. LDRx = 11: LED driver x is individual brightness and group dimming/blinking can be controlled through its PWMx register and the GRPPWM registers. 26 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 9.6.7 I2C Bus Subaddress Registers 1 to 3 (SUBADR1 to SUBADR3) Table 11 describes I2C Bus Subaddress Registers 1 to 3. Table 11. SUBADR1 to SUBADR3 – I2C Bus Subaddress Registers 1 to 3 (Address 18h to 1Ah) Bit Description ADDRESS 18h 19h 1Ah (1) (2) REGISTER SUBADR1 SUBADR2 SUBADR3 SYMBOL 7:1 A1[7:1] R/W 1101 001 0 A1[0] R 0 7:1 A2[7:1] R/W 1101 010 0 A2[0] R 0 7:1 A3[7:1] 0 A3[0] ACCESS (1) BIT VALUE R/W 0 I2C Bus subaddress 1 (2) Reserved (2) I2C Bus subaddress 2 (2) Reserved 1101 100 R DESCRIPTION (2) (2) I2C Bus subaddress 3 (2) Reserved R = read, W = write Default value Subaddresses are programmable through the I2C Bus. Default power-up values are D2h, D4h, D8h. The TLC59116-Q1 does not acknowledge these addresses immediately after power-up (the corresponding SUBx bit in MODE1 register is equal to 0). Once subaddresses have been programmed to valid values, the SUBx bits (MODE1 register) must be set to 1 to allows the device to acknowledge these addresses. Only the 7 MSBs representing the I2C Bus subaddress are valid. The LSB in SUBADRx register is a read-only bit (0). When SUBx is set to 1, the corresponding I2C Bus subaddress can be used during either an I2C Bus read or write sequence. 9.6.8 LED All Call I2C Bus Address Register (ALLCALLADR) Table 12 describes the LED All Call I2C Bus Address Register. Table 12. ALLCALLADR – LED All Call I2C Bus Address Register (Address 1Bh) Bit Description ADDRESS 1Bh (1) (2) REGISTER ALLCALLADR ACCESS (1) BIT SYMBOL 7:1 AC[7:1] R/W 1101 000 VALUE 0 AC[0] R 0 (2) DESCRIPTION (2) All Call I2C Bus address Reserved R = read, W = write Default value The LED All Call I2C Bus address allows all the TLC59116-Q1 devices in the bus to be programmed at the same time (ALLCALL bit in register MODE1 must be equal to 1, which is the power-up default state). This address is programmable through the I2C Bus and can be used during either an I2C Bus read or write sequence. The register address can also be programmed as a Sub Call. Only the seven MSBs representing the All Call I2C bus address are valid. The LSB in ALLCALLADR register is a read-only bit (0). If ALLCALL bit = 0, the device does not acknowledge the address programmed in register ALLCALLADR. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 27 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 9.6.9 Output Gain Control Register (IREF) Table 13 describes the Output Gain Control Register. Table 13. IREF – Output Gain Control Register (Address 1Ch) Bit Description ADDRESS 1Ch REGISTER SYMBOL 7 CM R/W 1 (2) 6 HC R/W 1 (2) IREF 5:0 (1) (2) CC[5:0] ACCESS (1) BIT R/W VALUE 11 1111 DESCRIPTION High/low current multiplier Subcurrent (2) Current multiplier R = read, W = write Default value IREF determines the voltage gain (VG), which affects the voltage at the REXT terminal and indirectly the reference current (Iref) flowing through the external resistor at terminal REXT. Bit 0 is the Current Multiplier (CM) bit, which determines the ratio IOUT,target/Iref. Each combination of VG and CM sets a Current Gain (CG). • VG: the relationship between {HC,CC[0:5]} and the voltage gain is calculated as shown: VG = (1 + HC) × (1 + D/64) / 4 D = CC0 × 25 + CC1 × 24 + CC2 × 23 + CC3 × 22 + CC4 × 21 + CC5 × 20 Where HC is 1 or 0, and D is the binary value of CC[0:5]. So, the VG could be regarded as a floating-point number with 1-bit exponent HC and 6-bit mantissa CC[0:5]. {HC,CC[0:5]} divides the programmable voltage gain (VG) into 128 steps and two sub-bands: Low-voltage subband (HC = 0): VG = 1/4 to 127/256, linearly divided into 64 steps High-voltage subband (HC = 1): VG = 1/2 to 127/128, linearly divided into 64 steps • CM: In addition to determining the ratio IOUT,target/Iref, CM limits the output current range. High Current Multiplier (CM = 1): IOUT,target/Iref = 15, suitable for output current range IOUT = 10 mA to 120 mA. Low Current Multiplier (CM = 0): IOUT,target/Iref = 5, suitable for output current range IOUT = 5 mA to 40 mA • CG: The total Current Gain is defined as: VREXT = 1.26 V × VG Iref = VREXT/Rext, if the external resistor (Rext) is connected to ground. IOUT,target = Iref × 15 × 3CM – 1 = 1.26 V/Rext × VG × 15 × 3CM – 1 = (1.26 V/Rext × 15) × CG CG = VG × 3CM – 1 Therefore, CG = (1/12) to (127/128), divided into 256 steps. Examples • IREF Code {CM, HC, CC[0:5]} = {1,1,111111} VG = 127/128 = 0.992 and CG = VG × 30 = VG = 0.992 • IREF Code {CM, HC, CC[0:5]} = {1,1,000000} VG = (1 + 1) × (1 + 0/64)/4 = 1/2 = 0.5, and CG = 0.5 • IREF Code {CM, HC, CC[0:5]} = {0,0,000000} VG = (1 + 0) × (1 + 0/64)/4 = 1/4, and CG = (1/4) × 3–1 = 1/12 After power-on, the default value of the Configuration Code {CM, HC, CC[0:5]} is {1,1,111111}. Therefore, VG = CG = 0.992. The relationship between the Configuration Code and the Current Gain is shown in Figure 22. 28 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 1.00 CM = 1 (High Current Multiplier) CM = 0 (Low Current Multiplier) Current Gain (CG) 0.75 HC = 0 (Low Voltage SubBand) 0.50 HC = 1 (High Voltage SubBand) HC = 0 (Low Voltage SubBand) HC = 1 (High Voltage SubBand) 0.25 {1,1,110000} {1,1,100000} {1,1,010000} {1,1,000000} {1,0,110000} {1,0,100000} {1,0,010000} {1,0,000000} {0,1,110000} {0,1,100000} {0,1,010000} {0,1,000000} {0,0,110000} {0,0,100000} {0,0,010000} {0,0,000000} 0.00 Configuration Code (CM, HC, CC[0:5]) in Binary Format Figure 22. Current Gain vs Configuration Code 9.6.10 Error Flags Registers (EFLAG1, EFLAG2) Table 14 describes Error Flags Registers 1 and 2. Table 14. EFLAG1, EFLAG2 – Error Flags Registers (Address 1Dh and 1Eh) Bit Description ADDRESS 1Dh 1Eh (1) (2) (3) REGISTER EFLAG1 EFLAG2 ACCESS (1) SYMBOL 0 EFLAG1[0] 0 Channel 0 1 EFLAG1[1] 0 Channel 1 2 EFLAG1[2] 0 Channel 2 3 EFLAG1[3] 0 Channel 3 4 EFLAG1[4] 0 Channel 4 5 EFLAG1[5] 0 Channel 5 6 EFLAG1[6] 0 Channel 6 7 EFLAG1[7] 0 Channel 7 0 EFLAG1[0] 0 Channel 8 1 EFLAG1[1] 0 Channel 9 2 EFLAG1[2] 0 Channel 10 3 EFLAG1[3] 0 Channel 11 4 EFLAG1[4] 0 Channel 12 5 EFLAG1[5] 0 Channel 13 6 EFLAG1[6] 0 Channel 14 7 EFLAG1[7] 0 Channel 15 R R VALUE (2) BIT DESCRIPTION (3) R = read, W = write Default value At power-up, in order to initialize the Error Flags registers, the host must write 1 to bit 7 of the MODE2 register and then write 0 to bit 7 of the MODE2 register. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 29 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 10 Application and Implementation NOTE Information in the following applications sections is not part of the TI component specification, and TI does not warrant its accuracy or completeness. TI’s customers are responsible for determining suitability of components for their purposes. Customers should validate and test their design implementation to confirm system functionality. 10.1 Application Information 10.1.1 Constant Current Output In LED display applications, TLC59116-Q1 provides nearly no current variations from channel to channel and from device to device. While IOUT ≤ 52 mA, the maximum current skew between channels is less than ±6% and less than ±10% between devices. 10.1.2 Adjusting Output Current TLC59116-Q1 scales up the reference current (Iref) set by the external resistor (Rext) to sink the output current (Iout) at each output port. Table 13 shows the Configuration Code and discusses bits CM, HC, and CC[5:0]. The following formulas can be used to calculate the target output current IOUT,target in the saturation region: VREXT = 1.26 V × VG Iref = VREXT/Rext, if another end of the external resistor Rext is connected to ground IOUT,target = Iref × 15 × 3CM – 1 (3) (4) (5) Where Rext is the resistance of the external resistor connected to the REXT terminal, and VREXT is the voltage of REXT, which is controlled by the programmable voltage gain (VG), which is defined by the Configuration Code. The Current Multiplier bit (CM) sets the ratio IOUT,target/Iref to 15 or 5 (sets the exponent CM – 1 to either 0 or –1). After power-on, the default value of VG is 127/128 = 0.992, and the default value of CM is 1, so that the ratio IOUT,target/Iref = 15. Based on the default VG and CM: VREXT = 1.26 V × 127/128 = 1.25 V IOUT,target = (1.25 V/Rext) × 15 (6) (7) Therefore, the default current is approximately 20 mA at 931 Ω. The default relationship after power-on between IOUT,target and Rext is shown in Figure 24. shows the output voltage versus the output current with several different resistor values on REXT. This shows the minimum voltage required at the device to have full VF across the LED. The VLED voltage must be higher than the VF plus the VOL of the driver. If the VLED is too high, more power will be dissipated in the driver. If this is the case, a resistor can be inserted in series with the LED to dissipate the excess power and reduce the thermal conditions on the driver. If a single driver is used with LEDs that have different VF values, resistors can also be used in series with the LED to remove the excess power from the driver. In cases where not all outputs are being used, the unused outputs can be left floating without issue. 30 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 10.2 Typical Application The TLC59116-Q1 outputs can be wired in parallel to increase the current per LED string. VLED VCC SDA SDA OUT0 SCL SCL OUT1 TLC59116-Q1 System Controller VCC A0 A1 A2 A3 RESET RESET REXT OUT2 OUT3 OUT4 OUT5 OUT6 OUT7 GND Address: 00h Figure 23. Parallel Channels 10.2.1 Design Requirements Set the LED current to 50 mA while the IREF register is at the default value (CG = 0.992). 10.2.2 Detailed Design Procedure The goal of this design is to set the LED current to 50 mA. Because two outputs are in parallel, the LED current should actually be set to 25 mA. With the IREF register at the default value: IOUT,target = ( 1.25 V / REXT ) × 15 (8) Using this equation, the appropriate REXT is calculated to be 750 Ω. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 31 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com Typical Application (continued) 10.2.3 Application Curve 140 Output Current, Iout (A) 120 100 80 60 40 20 0 0 500 1000 1500 2000 2500 3000 3500 4000 Rext (W) Figure 24. IOUT,target vs Rext 32 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 11 Power Supply Recommendations TLC59116-Q1 is designed to operate from a VCC range of 3 V to 5.5 V. 12 Layout 12.1 Layout Guidelines The I2C signals (SDA / SCL) should be kept away from potential noise sources. The traces carrying power through the LEDs should be wide enough to the handle necessary current. All LED current passes through the device and into the ground node. The connection between the device ground and the circuit board ground must be a strong connection. 12.2 Layout Example VIA to GND REXT VCC A0 SDA A1 SCL To µC A2 RESET To µC A3 GND OUT0 OUT15 OUT1 OUT14 OUT2 OUT13 OUT3 OUT12 GND To µC GND OUT4 OUT11 OUT5 OUT10 OUT6 OUT9 OUT7 OUT8 Figure 25. PW-28 Layout Example Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 33 TLC59116-Q1 SLDS223A – MARCH 2016 – REVISED MARCH 2016 www.ti.com 12.3 Thermal Considerations The maximum IC junction temperature should be restricted to 150°C under normal operating conditions. To calculate the maximum allowable dissipation, PD(max) for a given ambient temperature, use Equation 9 as a guideline: PD(max) = TJ(max) - TA θJA where • • • • PD(max) = maximum allowable power dissipation TJ(max) = maximum allowable junction temperature (150°C for the TLC59116-Q1) TA = ambient temperature of the device ΘJA = junction to air thermal impedance. (9) See Thermal Information section. This parameter is highly dependent upon board layout. Power dissipation in the device is determined by the LED current and the voltage at the OUTx pins. For example, if the LED current is 50 mA continuous through each channel and the output voltage is 1 V on each channel, then the total power dissipation is 50 mA × 1 V × 16 ch = 0.8 W. 34 Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 TLC59116-Q1 www.ti.com SLDS223A – MARCH 2016 – REVISED MARCH 2016 13 Device and Documentation Support 13.1 Documentation Support 13.1.1 Related Documentation For related documentation see the following: • TLC59116EVM-390 User's Guide, SLVU296 • TLC59116FEVM-571, SLVU367 13.2 Community Resources The following links connect to TI community resources. Linked contents are provided "AS IS" by the respective contributors. They do not constitute TI specifications and do not necessarily reflect TI's views; see TI's Terms of Use. TI E2E™ Online Community TI's Engineer-to-Engineer (E2E) Community. Created to foster collaboration among engineers. At e2e.ti.com, you can ask questions, share knowledge, explore ideas and help solve problems with fellow engineers. Design Support TI's Design Support Quickly find helpful E2E forums along with design support tools and contact information for technical support. 13.3 Trademarks E2E is a trademark of Texas Instruments. All other trademarks are the property of their respective owners. 13.4 Electrostatic Discharge Caution These devices have limited built-in ESD protection. The leads should be shorted together or the device placed in conductive foam during storage or handling to prevent electrostatic damage to the MOS gates. 13.5 Glossary SLYZ022 — TI Glossary. This glossary lists and explains terms, acronyms, and definitions. 14 Mechanical, Packaging, and Orderable Information The following pages include mechanical, packaging, and orderable information. This information is the most current data available for the designated devices. This data is subject to change without notice and revision of this document. For browser-based versions of this data sheet, refer to the left-hand navigation. Submit Documentation Feedback Copyright © 2016, Texas Instruments Incorporated Product Folder Links: TLC59116-Q1 35 PACKAGE OPTION ADDENDUM www.ti.com 10-Dec-2020 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) (4/5) (6) TLC59116ITPWRQ1 ACTIVE TSSOP PW 28 2000 RoHS & Green NIPDAU Level-3-260C-168 HR -40 to 105 Y59116Q TLC59116ITPWTQ1 ACTIVE TSSOP PW 28 250 RoHS & Green NIPDAU Level-3-260C-168 HR -40 to 105 Y59116Q (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
TLC59116ITPWRQ1 价格&库存

很抱歉,暂时无法提供与“TLC59116ITPWRQ1”相匹配的价格&库存,您可以联系我们找货

免费人工找货