0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
TS5A4597DBVR

TS5A4597DBVR

  • 厂商:

    BURR-BROWN(德州仪器)

  • 封装:

    SOT23-5

  • 描述:

    IC SWITCH SPST SOT23-5

  • 数据手册
  • 价格&库存
TS5A4597DBVR 数据手册
    W      www.ti.com SCDS182 − FEBRUARY 2005 Description The TS5A4597 is a single-pole single-throw (SPST) analog switch that is designed to operate from 2 V to 5.5 V. This device can handle both digital and analog signals, and signals up to V+ can be transmitted in either direction. Applications D Sample-and-Hold Circuits Features D Low ON-State Resistance (8 W) D ON-State Resistance Flatness (1.5 W) D Control Inputs Are 5.5-V Tolerant D Low Charge Injection (5 pC Max) D 450-MHz −3-dB Bandwidth at 255C D Low Total Harmonic Distortion (THD) (0.04%) D 2-V to 5.5-V Single-Supply Operation D Specified at 5-V and 3.3-V Nodes D −85-dB OFF Isolation at 1 MHz D Latch-Up Performance Exceeds 100 mA Per D D D Battery-Powered Equipment (Cellular Phones, PDAs) D Audio and Video Signal Routing D Communication Circuits D D PCMCIA Cards JESD 78, Class II 0.5-nA Max OFF Leakage ESD Performance Tested Per JESD 22 − 2000-V Human-Body Model (A114-B, Class II) − 1000-V Charged-Device Model (C101) TTL/CMOS-Logic Compatible Summary of Characteristics V+ = 5 V, TA = 25°C SOT-23 OR SC-70 PACKAGE (TOP VIEW) IN 1 5 V+ 4 NC Single Pole Single Throw (SPST) Configuration Number of channels COM 2 1 8Ω ON-state resistance (ron) GND 3 1.5 Ω ON-state resistance flatness (ron(flat)) Turn-on/turn-off time (tON/tOFF) 17 ns/14 ns Charge injection (QC) 5 pC Bandwidth (BW) OFF isolation (OISO) FUNCTION TABLE NC TO COM, COM TO NC IN 450 MHz −85 dB at 1 MHz Total harmonic distortion (THD) 0.04% ±0.5 nA Leakage current(ICOM(OFF)/INC(OFF)) L ON Power-supply current (I+) H OFF Package option 0.25 µA 5-pin SOT-23 or SC-70 ORDERING INFORMATION TA −40°C to 85°C PACKAGE(1) ORDERABLE PART NUMBER TOP-SIDE MARKING(2) SOT (SOT-23) − DBV Tape and reel TS5A4597DBVR JSD_ SOT (SC−70) − DCK Tape and reel TS5A4597DCKR JV_ (1) Package drawings, standard packing quantities, thermal data, symbolization, and PCB design guidelines are available at www.ti.com/sc/package. (2) DBV/DCK: The actual top-side marking has one additional character that designates the assembly/test site. Please be aware that an important notice concerning availability, standard warranty, and use in critical applications of Texas Instruments semiconductor products and disclaimers thereto appears at the end of this data sheet.     !"#   $"%&! '#( '"! !  $#!! $# )# #  #* "# '' +,( '"! $!#- '#  #!#&, !&"'# #-  && $##( Copyright  2005, Texas Instruments Incorporated     W      www.ti.com SCDS182 − FEBRUARY 2005 Pin Configurations Available in Other Pin Configurations IN 1 5 V+ 4 NC COM 1 NO 2 GND 3 5 V+ 4 IN COM 2 GND 3 TS5A4597 TS5A4594 COM 1 NC 2 GND 3 5 V+ IN 1 5 V+ 4 NO COM 2 4 IN TS5A4595 GND 3 TS5A4596 Absolute Minimum and Maximum Ratings(1)(2) over operating free-air temperature range (unless otherwise noted) MIN MAX V+ VNC VCOM Supply voltage range(3) −0.3 6 V Analog voltage range(3)(4) −0.3 V+ + 0.3 V IK INC ICOM Analog port diode current VNC, VCOM < 0 −50 On-state switch current VNC, VCOM = 0 to V+ −20 20 mA VI IIK Digital input voltage range(3)(4) −0.3 6 V I+ IGND Continuous current through V+ θJA Package thermal impedance(5) Digital input clamp current VI < 0 mA −50 mA 100 Continuous current through GND UNIT −100 mA mA DBV package 206 DCK package 252 °C/W Tstg Storage temperature range −65 150 °C (1) Stresses above these ratings may cause permanent damage. Exposure to absolute maximum conditions for extended periods may degrade device reliability. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those specified is not implied. (2) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum (3) All voltages are with respect to ground, unless otherwise specified. (4) The input and output voltage ratings may be exceeded if the input and output clamp-current ratings are observed. (5) The package thermal impedance is calculated in accordance with JESD 51-7. 2     W      www.ti.com SCDS182 − FEBRUARY 2005 Electrical Characteristics for 5-V Supply(1) V+ = 4.5 V to 5.5 V, TA = −40°C to 85°C (unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TA V+ MIN TYP MAX UNIT Analog Switch Analog signal range VCOM, VNC 0 VNC = 3.5 V, ICOM = 10 mA, Switch ON, See Figure 13 25°C VNC = 1.5 V, 2.5 V, 3.5 V, ICOM = 10 mA, Switch ON, See Figure 13 25°C ron(flat) NC OFF leakage current VNC = 1 V, VCOM = 4.5 V, or VNC = 4.5 V, VCOM = 1 V, Switch OFF, See Figure 14 25°C INC(OFF) COM OFF leakage current VCOM = 1 V, VNC = 4.5 V, or VCOM = 4.5 V, VNC = 1 V, Switch OFF, See Figure 14 25°C ICOM(OFF) INC(ON) VNC = 1 V, VCOM = 1 V, or VNC = 4.5 V, VCOM = 4.5 V, or VNC = 1 V, 4.5 V, VCOM = Open, Switch ON, See Figure 15 VCOM = 1 V, VNC = 1 V, or VCOM = 4.5 V, VNC = 4.5 V, or VCOM = 1 V, 4.5 V, VNC = Open, Switch ON, See Figure 15 ON-state resistance ron ON-state resistance flatness NC ON leakage current COM ON leakage current ICOM(ON) Full V+ 5 4.5 V 8 10 0.5 2 −0.5 0.01 nA −5 −0.5 5 0.01 0.5 5.5 V Full nA −5 25°C Ω 0.5 5.5 V Full Ω 1.5 4.5 V Full V −1 5 0.01 1 5.5 V nA Full −10 25°C −1 10 0.01 1 5.5 V nA Full −10 10 Full 2.4 5.5 V Full 0 0.8 V 25°C −0.5 Digital Control Input (IN) Input logic high Input logic low Input leakage current VIH VIL IIH, IIL VI = 5.5 V or 0 Full 5.5 V −5 0.01 0.5 5 nA (1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum 3     W      www.ti.com SCDS182 − FEBRUARY 2005 Electrical Characteristics for 5-V Supply(1) (continued) V+ = 4.5 V to 5.5 V, TA = −40°C to 85°C (unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TA V+ MIN TYP MAX 12 17 UNIT Dynamic Turn-on time VNC = 3 V, RL = 300 Ω, CL = 35 pF, See Figure 17 25°C 5V tON Full 4.5 V to 5.5 V Turn-off time VNC = 3 V, RL = 300 Ω, CL = 35 pF, See Figure 17 25°C 5V tOFF Full 4.5 V to 5.5 V VGEN = 0, RGEN = 0, CL = 1 nF, See Figure 20 25°C 5V 2 19 9 ns 14 17 ns Charge injection QC NC OFF capacitance CNC(OFF) VNC = 0, f = 1 MHz, Switch OFF, See Figure 16 25°C 5V 6.5 pF COM OFF capacitance CCOM(OFF) VCOM = 0, f = 1 MHz, Switch OFF, See Figure 16 25°C 5V 6.5 pF NC ON capacitance CNC(ON)) VNC = 0, f = 1 MHz, Switch ON, See Figure 16 25°C 5V 13 pF COM ON capacitance CCOM(ON) VCOM = 0, f = 1 MHz, Switch ON, See Figure 16 25°C 5V 13 pF CI VI = V+ or GND, See Figure 16 25°C 5V 3 pF BW RL = 50 Ω, Signal = 0 dBm, Switch ON, See Figure 18 25°C 5V 450 MHz Digital input capacitance Bandwidth 5 pC OFF isolation OISO RL = 50 Ω, f = 10 MHz, VNC = 1 VRMS, Switch OFF, See Figure 19 25°C 5V −85 dB Total harmonic distortion THD RL = 600 Ω, CL = 50 pF, VSOURCE = 5 Vp-p, f = 20 Hz to 20 kHz, See Figure 21 25°C 5V 0.04 % Supply 25°C Positive supply I+ VI = V+ or GND, Switch ON or OFF 5.5 V current Full (1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum 4 0.01 0.25 0.5 µA A     W      www.ti.com SCDS182 − FEBRUARY 2005 Electrical Characteristics for 3-V Supply(1) V+ = 2.7 V to 3.6 V, TA = −40°C to 85°C (unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TA V+ MIN TYP MAX UNIT Analog Switch Analog signal range VCOM, VNC ON-state resistance ron ON-state resistance flatness ron(flat) 0 VNC = 1.5 V, ICOM = 10 mA, Switch ON, See Figure 13 25°C VNC = 1.5 V, 2.5 V, ICOM = 10 mA, Switch ON, See Figure 13 25°C Full VNC = 1 V, VCOM = 3 V, or VNC = 3 V, VCOM = 1 V, Switch OFF, See Figure 14 25°C COM OFF leakage current VCOM = 1 V, VNC = 3 V, or VCOM = 3 V, VNC = 1 V, Switch OFF, See Figure 14 25°C ICOM(OFF) INC(ON) VNC = 1 V, VCOM = 1 V, or VNC = 3 V, VCOM = 3, or VNC = 1 V, 3 V, VCOM = Open, Switch ON, See Figure 15 VCOM = 1 V, VNC = 1 V, or VCOM = 3 V, VNC = 3 V, or VCOM = 1 V, 3 V, VNC = Open, Switch ON, See Figure 15 ICOM(ON) 16 20 1.8 −0.5 0.01 −0.5 5 0.01 0.5 3.6 V nA −5 25°C Ω nA −5 Full Ω 0.5 3.6 V Full V 6 7 Full INC(OFF) COM ON leakage current 9.5 2.7 V 2.7 V NC OFF leakage current NC ON leakage current V+ −1 5 0.01 1 3.6 V nA Full −10 25°C −1 10 0.01 1 3.6 V nA Full −10 10 Full 2 5.5 V Full 0 0.8 V 25°C −0.5 Digital Control Input (IN) Input logic high Input logic low Input leakage current VIH VIL IIH, IIL VI = V+ or 0 Full 3.6 V −5 0.01 0.5 5 nA (1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum 5     W      www.ti.com SCDS182 − FEBRUARY 2005 Electrical Characteristics for 3-V Supply(1) (continued) V+ = 2.7 V to 3.6 V, TA = −40°C to 85°C (unless otherwise noted) PARAMETER TEST CONDITIONS SYMBOL TA V+ MIN TYP MAX 20 30 UNIT Dynamic Turn-on time VCOM = 2 V, RL = 300 Ω, CL = 35 pF, See Figure 17 25°C 3V tON Full 2.7 V to 3.6 V Turn-off time VCOM = 2 V, RL = 300 Ω, CL = 35 pF, See Figure 17 25°C 3V tOFF Full 2.7 V to 3.6 V VNC = 0, CL = 1 nF, See Figure 20 25°C 3V 1 35 15 ns 25 30 ns Charge injection QC NC OFF capacitance CNC(OFF) VNC = V+ or GND, Switch OFF, See Figure 16 25°C 3V 6.5 pF COM OFF capacitance CCOM(OFF) VCOM = V+ or GND, Switch OFF, See Figure 16 25°C 3V 6.5 pF NC ON capacitance CNC(ON) VNC = V+ or GND, Switch ON, See Figure 16 25°C 3V 13 pF COM ON capacitance CCOM(ON) VCOM = V+ or GND, Switch ON, See Figure 16 25°C 3V 13 pF CI VI = V+ or GND, See Figure 16 25°C 3V 3 pF BW RL = 50 Ω, Signal = 0 dBm, Switch ON, See Figure 18 25°C 3V 450 MHz Digital input capacitance Bandwidth 4 pC OFF isolation OISO VNC = 1 VRMS, f = 1 MHz, CL = 5 pF, Switch OFF, See Figure 19 25°C 3V −85 dB Total harmonic distortion THD RL = 600 Ω, CL = 50 pF, VSOURCE = 3 Vp-p, f = 20 Hz to 20 kHz, See Figure 21 25°C 3V 0.09 % Supply 25°C Positive supply I+ VI = V+ or GND, Switch ON or OFF 3.6 V current Full (1) The algebraic convention, whereby the most negative value is a minimum and the most positive value is a maximum 6 0.01 0.25 0.5 µA A     W      www.ti.com SCDS182 − FEBRUARY 2005 TYPICAL PERFORMANCE 10 8 TA = 25_C 8 6 855C 255C 6 ron (W) ron (Ω) V+ = 3 V 4 4 –405C V+ = 5 V 2 2 0 0 0 1 2 3 4 5 0 1 2 VCOM (V) 5 Figure 2. ron vs VCOM (V+ = 5 V) 1.0 10 –405C ICOM(ON)/INO(ON) 0.8 Leakage Current (nA) 8 ron (W) 4 VCOM (V) Figure 1. ron vs VCOM 6 4 255C 855C 2 0.6 INO(OFF)/ICOM(OFF) 0.4 0.2 0.0 0 0 1 2 3 VCOM (V) −40°C 25°C TA (°C) 85°C Figure 4. Leakage Current vs Temperature (V+ = 5 V) Figure 3. ron vs VCOM (V+ = 3 V) 20 2 18 1 tON tOFF 16 0 tON/tOFF (ns) Charge Injection (pC) 3 V+ = 3 V −1 V+ = 5 V −2 −3 14 12 10 8 6 −4 0 1 2 3 4 Bias Voltage (V) Figure 5. Charge-Injection (QC) vs VCOM 5 0 1 2 3 4 5 6 V+ (V) Figure 6. tON and tOFF vs Supply Voltage 7     W      www.ti.com SCDS182 − FEBRUARY 2005 TYPICAL PERFORMANCE (continued) 12 Logic Level Threshold (nA) 3 tON/tOFF (ns) 11 10 9 tON 8 7 tOFF 6 −40°C 25°C VIH 2 1 VIL 0 0 85°C 1 2 TA (5C) Figure 7. tON and tOFF vs Temperature (V+ = 5 V) 3 V+ (V) 4 5 6 Figure 8. Logic-Level Threshold vs V+ 0.0 0 −0.5 −20 Attenuation (dB) Gain (dB) −1.0 −1.5 −2.0 −2.5 −3.0 −40 −60 −80 −100 −3.5 −4.0 0.1 1 10 Frequency (MHz) 100 −120 0.1 1000 Figure 9. Bandwidth (Gain vs Frequency) (V+ = 5 V) 1 10 Frequency (MHz) 100 1000 Figure 10. OFF Isolation vs Frequency 10 0.20 V+ = 5 V 9 8 0.15 7 5 V+ = 3 V 4 3 2 THD (%) I+ (µA) 6 0.10 V+ = 3 V 0.05 V+ = 5 V 1 0 −40°C 25°C 85°C TA (5C) Figure 11. Power-Supply Current vs Temperature 8 0.00 0.1 1 10 100 1000 Frequency (MHz) Figure 12. Total Harmonic Distortion vs Frequency     W      www.ti.com SCDS182 − FEBRUARY 2005 PIN DESCRIPTION PIN NUMBER NAME DESCRIPTION 1 IN 2 COM Digital control pin to connect COM to NC Common 3 GND Digital ground 4 NC Normally closed 5 V+ Power supply PARAMETER DESCRIPTION SYMBOL DESCRIPTION VCOM Voltage at COM VNC Voltage at NC ron Resistance between COM and NC ports when the channel is ON ron(flat) Difference between the maximum and minimum value of ron in a channel over the specified range of conditions INC(OFF) Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the OFF state INC(ON) Leakage current measured at the NC port, with the corresponding channel (NC to COM) in the ON state and the output (COM) open ICOM(OFF) Leakage current measured at the COM port, with the corresponding channel (COM to NC) in the OFF state ICOM(ON) Leakage current measured at the COM port, with the corresponding channel (COM to NC) in the ON state and the output (NC) open VIH Minimum input voltage for logic high for the control input (IN) VIL Maximum input voltage for logic low for the control input (IN) VI Voltage at the control input (IN) IIH, IIL Leakage current measured at the control input (IN) tON Turn-on time for the switch. This parameter is measured under the specified range of conditions and by the propagation delay between the digital control (IN) signal and analog output (COM or NC) signal when the switch is turning ON. tOFF Turn-off time for the switch. This parameter is measured under the specified range of conditions and by the propagation delay between the digital control (IN) signal and analog output (COM or NC) signal when the switch is turning OFF. QC Charge injection is a measurement of unwanted signal coupling from the control (IN) input to the analog (NC or COM) output. This is measured in coulomb (C) and measured by the total charge induced due to switching of the control input. Charge injection, QC = CL × ∆VCOM, CL is the load capacitance, and ∆VCOM is the change in analog output voltage. CNC(OFF) CNC(ON) Capacitance at the NC port when the corresponding channel (NC to COM) is OFF CCOM(OFF) CCOM(ON) Capacitance at the COM port when the corresponding channel (COM to NC) is OFF CI Capacitance of control input (IN) OISO OFF isolation of the switch is a measurement of OFF-state switch impedance. This is measured in dB in a specific frequency, with the corresponding channel (NC to COM) in the OFF state. BW Bandwidth of the switch. This is the frequency in which the gain of an ON channel is −3 dB below the DC gain. THD Total harmonic distortion describes the signal distortion caused by the analog switch. This is defined as the ratio of root mean square (RMS) value of the second, third, and higher harmonic to the absolute magnitude of the fundamental harmonic. I+ Static power-supply current with the control (IN) pin at V+ or GND Capacitance at the NC port when the corresponding channel (NC to COM) is ON Capacitance at the COM port when the corresponding channel (COM to NC) is ON 9     W      www.ti.com SCDS182 − FEBRUARY 2005 PARAMETER MEASUREMENT INFORMATION V+ VNC NC COM + VCOM Channel ON r on + VI ICOM IN VCOM * VNC W ICOM VI = VIH or VIL + GND Figure 13. ON-State Resistance (ron) V+ VNC NC COM + VI VCOM + OFF-State Leakage Current Channel OFF VI = VIH or VIL IN + GND Figure 14. OFF-State Leakage Current (ICOM(OFF), INC(OFF)) V+ VNC NC COM + VI VCOM ON-State Leakage Current Channel ON VI = VIH or VIL IN + GND Figure 15. ON-State Leakage Current (ICOM(ON), INC(ON)) 10     W      www.ti.com SCDS182 − FEBRUARY 2005 V+ VNC NC Capacitance Meter VBIAS = V+ or GND VI = VIH or VIL VCOM COM VBIAS Capacitance is measured at NC, COM, and IN inputs during ON and OFF conditions. IN VI GND Figure 16. Capacitance (CI, CCOM(OFF), CCOM(ON), CNC(OFF), CNC(ON)) V+ NC VCOM(3) VI VNC TEST RL CL tON 300 Ω 35 pF tOFF 300 Ω 35 pF COM CL(2) RL IN Logic Input(1) V+ Logic Input (VI) GND 50% 50% 0 tON tOFF Switch Output (VNC) 90% 90% (1) All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr < 5 ns, tf < 5 ns. (2) CL includes probe and jig capacitance. (3) See Electrical Characteristics for VCOM. Figure 17. Turn-On (tON) and Turn-Off Time (tOFF) V+ Network Analyzer 50 W VNC NC Channel ON: NC to COM COM VCOM Source Signal VI = V+ or GND Network Analyzer Setup 50 W VI + IN Source Power = 0 dBm (632-mV P-P at 50-W load) GND DC Bias = 350 mV Figure 18. Bandwidth (BW) 11     W      www.ti.com SCDS182 − FEBRUARY 2005 V+ Network Analyzer Channel OFF: NC to COM 50 W VNC NC VI = V+ or GND COM Source Signal VCOM 50 W Network Analyzer Setup VI 50 W Source Voltage = 1 VRMS IN + DC Bias = 350 mV GND Figure 19. OFF Isolation (OISO) V+ RGEN VGEN Logic Input (VI) VIH OFF ON OFF V IL NC COM + VCOM ∆VCOM VCOM CL(1) VI VGEN = 0 to V+ RGEN = 0 CL = 1 nF QC = CL × ∆VCOM VI = VIH or VIL IN Logic Input(2) GND (1) CL includes probe and jig capacitance. (2) All input pulses are supplied by generators having the following characteristics: PRR ≤ 10 MHz, ZO = 50 Ω, tr < 5 ns, tf < 5 ns. Figure 20. Charge Injection (QC) Channel ON: COM to NC VSOURCE = V+ P-P LP Filter = 80 kHz VI = V+/2 or −V+/2 fSOURCE = 20 Hz to 20 kHz HP Filter = 10 Hz RL = 600 Ω CL = 50 pF V+/2 Audio Analyzer NC Source Signal COM CL(1) 600 W VI 600 W IN GND −V+/2 (1) CL includes probe and jig capacitance. Figure 21. Total Harmonic Distortion (THD) 12 PACKAGE OPTION ADDENDUM www.ti.com 10-Dec-2020 PACKAGING INFORMATION Orderable Device Status (1) Package Type Package Pins Package Drawing Qty Eco Plan (2) Lead finish/ Ball material MSL Peak Temp Op Temp (°C) Device Marking (3) (4/5) (6) TS5A4597DBVR ACTIVE SOT-23 DBV 5 3000 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 JSDR TS5A4597DCKR ACTIVE SC70 DCK 5 3000 RoHS & Green NIPDAU Level-1-260C-UNLIM -40 to 85 JVR (1) The marketing status values are defined as follows: ACTIVE: Product device recommended for new designs. LIFEBUY: TI has announced that the device will be discontinued, and a lifetime-buy period is in effect. NRND: Not recommended for new designs. Device is in production to support existing customers, but TI does not recommend using this part in a new design. PREVIEW: Device has been announced but is not in production. Samples may or may not be available. OBSOLETE: TI has discontinued the production of the device. (2) RoHS: TI defines "RoHS" to mean semiconductor products that are compliant with the current EU RoHS requirements for all 10 RoHS substances, including the requirement that RoHS substance do not exceed 0.1% by weight in homogeneous materials. Where designed to be soldered at high temperatures, "RoHS" products are suitable for use in specified lead-free processes. TI may reference these types of products as "Pb-Free". RoHS Exempt: TI defines "RoHS Exempt" to mean products that contain lead but are compliant with EU RoHS pursuant to a specific EU RoHS exemption. Green: TI defines "Green" to mean the content of Chlorine (Cl) and Bromine (Br) based flame retardants meet JS709B low halogen requirements of
TS5A4597DBVR 价格&库存

很抱歉,暂时无法提供与“TS5A4597DBVR”相匹配的价格&库存,您可以联系我们找货

免费人工找货
TS5A4597DBVR
    •  国内价格
    • 150+1.22040

    库存:0