0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GKZ51

GKZ51

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

  • 描述:

    LIMIT SWITCH PLUNGER / SAFETY LI

  • 数据手册
  • 价格&库存
GKZ51 数据手册
Installation Instructions for the GKR/GKL Series Solenoid Key Operated Safety Interlock Switch IMPROPER INSTALLATION • Consult with local safety agencies and their requirements when designing a machine-control link, interface and all control elements that affect safety. • Strictly adhere to all installation instructions. Failure to comply with these instructions could result in death or serious injury. GENERAL INFORMATION The MICRO SWITCH GK Solenoid Key Operated Safety Interlock Switch is designed to lock protective guards that prevent access to hazardous motion so that dangerous machine operations can only take place if the protective guard is closed and locked. Likewise, the protective guard cannot be opened if hazardous motion is present. ISSUE 5 PK 81591 The control system must be designed so that hazardous motion can only take place when the protective guard is locked via the GKR/GKL Series Solenoid Key Operated Safety Interlock Switch. This control system design must ensure the guard locking device releases only when the dangerous conditions no longer exist (Figure 1). The guard locking device can be specified as either Mechanical Lock or Solenoid Lock (see order guide). Mechanical Lock occurs by internal spring force when the protective guard is closed and the key is inserted. Applying voltage to the solenoid unlocks the protective guard. When power failure occurs, the protective guard can be unlocked by actuating the auxiliary release. Solenoid Lock occurs by applying voltage to the solenoid after the protective guard is closed and the key is inserted. Removing voltage to the solenoid unlocks the protective guard. Figure 1: Example Safety Related Control Circuit INPUT GKR/GKL Key Operated Solenoid Safety Interlock Switch CONTROL Interface Back Check Primary Input Primary Safety Control Hardware (*) MOTION Primary Control Output Hazardous Machine Motion Secondary Monitoring Lines Secondary Monitoring Line Standard Inputs (Non-safety Related) PLC Secondary Control Primary Logic Control Non-hazardous Machine Motion • Honeywell FF-SR Series safety control modules may be used as an interface between protective safety equipment and machine control circuitry. These products offer redundancy, monitoring, and control reliability features that ensure the highest level of industrial safety. Sensing and Control GK Solenoid Safety Interlock Switch SAFETY ANALYSIS TECHNIQUES 1. Conduct Hazard Analysis and Risk Assessment Refer to: • OSHA Title 29, ANSI Standards. • European Norm EN 1050, Safety of Machines Risk Assessment. 2. Review Requirements and Safety Related Parts of the Control System • ANSI B11.19-1990 -- Safeguarding When Referenced by the Other B11 Machine Tool Safety Standards. • ANSI B11.20 -- System Energy Stopping. • European Norms: − EN954-1: Safety Related Parts of the Control Systems. − EN60204-1: Electrical Equipment of Machines. − prEN1088: Interlocking Devices With and Without Guard Locking. • Any other appropriate industry safety standards. PERFORM INSTALLATION AS FOLLOWS: 1. Assemble Switch Head (applies to Head Options “E” and “K” only) The one-way screws must be used on this head option to prevent voiding the warranty. Head options “E” and “K” are shipped unattached and may be indexed in 90° increments (Figure 2). • Remove cover. • Properly seat: − “O” ring (1) in its seal groove − Plunger (2) • Determine required key entry location. • Place head on housing, moving black spacer over enough to allow plunger to fall into position (contacts basic switch). • Securely fasten operating head to switch housing with the four one-way screws provided. Torque screws to 1,36-1,80 N-m [12-16 in-lb]. • Replace cover. Figure 2: Head Options “E” and “K” UNLOCK 2 1 LOCK 2 Honeywell • Sensing and Control Issue 5 PK 81591 Mount, Wire and Seal Switch Step 1 - Ensure you have the following: • Switch and key. • Wire (use 90°C wire when ambient temperature is over 75°C): − Stranded: 0.75 mm2 2.5 mm2, 18-14 AWG, or − Solid: 0.75 mm2 to 1.5 mm2, 18-16 AWG. • M5 or #10 screws. Step 2 - Mount switch and key: IMPROPER INSTALLATION • Ensure key travels to the minimum insertion dimension to ensure switch contact transfer (Figure 4). • Ensure key travels to maximum extraction distance to ensure correct operation of the positive break mechanism. • Do not exceed 100 N (22.4 lb) actuation force to key to prevent switch failure (Table 1). • Do not use the key as a stop for the door. Failure to comply with these instructions could result in death or serious injury. Table 1: Force Characteristics* Key actuation force for 51 N (11.5 lb) head with detent minimum Key extraction force for 31 N (7 lb) minimum head with detent Key actuation force for 22 N (5 lb) minimum head without detent Key extraction force for 2 N (0.5 lb) minimum head without detent *Device is in unlocked state. • Ensure proper clearance for switch and key at mounting location so that operation of the auxiliary release, as well as inspection and replacement, are possible. • Properly align switch and key together before mounting to equipment. • Mount switch and key (Figures 3 and 4). − Torque switch to mounting surface: 4,9-5,9 N-m [43-52 in-lb] M5 or #10. − Torque key to mounting surface: 2,4-2,8 N-m [21-25 in-lb] M5 or #10. GK Solenoid Safety Interlock Switch Issue 5 PK 81591 Figure 3: Switch and Key Mounting Dimensions (for reference only): mm/(in) GKL Shown (head of GKR is on right side of switch) 24,0 (0.94) 31,0 (1.22) 35,0 (1.38) 33,0 (1.30) 50,0 (1.97) 2 x 7,3 (0.29) 2 x ø 5,3 (0.21) 2 x 5,3 (0.21) 75,0 (2.95) 100,0 (3.94) 105,0 (4.13) 110,0 (4.33) 2 x 20,0 (0.79) 65,0 (2.56) 43,0 (1.69) 2 x 48,8 (1.92) 110,0 (4.33) Straight Key 100,0 (3.94) 90° Key 2 x 17,7 (0.70) 2 x ø 5,3 (0.21) 2 x ø 5,3 (0.21) 52,9 (2.08) 20,0 (0.79) 15,0 (0.59) 16,0 (0.63) 40,0 (1.57) 16,0 (0.63) 52,0 (2.05) 52,9 (2.08) 80,0 (3.15) Spring-loaded Key: Up/Down Spring-loaded Key: Left/Right 40,0 (1.58) 30,0 (1.18) 27,7 (1.09) 3,0 (0.12) 24,2 (0.95) 88,1 (3.47) 40,0 30,0 (1.58) (1.18) 88,1 (3.47) 2 x ø 5,3 (0.21) 23,6 (0.93) 44,5 (1.75) 2 x ø 5,3 (0.21) 22,1 (0.87) 35,5 (1.40) Honeywell • Sensing and Control 3 GK Solenoid Safety Interlock Switch Figure 4: Minimum Key Insertion Dimensions A. Straight Key B. 90° Key 1 Issue 5 Key 1. 23,0 mm [0.91 in] minimum insertion distance 2. 1500 mm [59.1 in] minimum swing radius 3. 1000 mm [39.4 in] minimum swing radius 1 2 2 2 3 D. Spring-loaded Key: Left/Right C. Spring-loaded Key: Up/Down 1 1 2 2 Key 1. 58,2 mm [2.29 in] minimum insertion distance 2. 150 mm [5.90 in) minimum swing radius 3. 1000 mm (39.4 in) minimum swing radius 3 3 Figure 5: External Switch Features Figure 6: Internal Switch Features Key 1. Auxiliary release 2. Conduit entry 3. Red LED 4. Green LED 1 1 4 2 4 PK 81591 3 2 4 Honeywell • Sensing and Control 3 Key 1. Monitor switch (S2) 2. Ground screw 3. Terminal strip 4. Safety switch (S1) GK Solenoid Safety Interlock Switch Step 3 - Wire switch: IMPROPER INSTALLATION Strictly adhere to all electrical connection instructions. Failure to comply with these instructions could result in death or serious injury. • Connect stranded or solid wire to switch’s pressure type connector terminals. Refer to circuit diagram on switch housing. Diagram depicts safety switch when key is inserted. (Refer to Figures 5, 6, 7, and 8 for a 1NC/1NO wiring configuration.) • M3 spade terminals up to 6,35 mm (0.25 in) wide may be used with contact block should additional wiring be required. • Solenoid is prewired to the terminal strip. • Torque wire connections as follows: − Torque connector to secure cable to switch enclosure (if required): 1,8-2,2 N-m (16-10 in-lb). − Torque switch terminal screws: 0,8-1,0 N-m (7-9 in-lb) M3. − Torque ground screw: 0,8-1,0 N-m (7-9 in-lb) M3. Step 4 - Seal conduit entry: • Seal with Teflon tape or pipe sealant. • If connector is used to secure cable to switch enclosure, torque connector to 1,8-2,2 N-m (16-19 in-lb). • Plug any unused conduit entry (plug included). Seal with Teflon tape or pipe sealant. Issue 5 PK 81591 MAINTENANCE AND INSPECTION IMPROPER MAINTENANCE • Strictly adhere to all maintenance and inspection instructions. • If wear, damage, or contamination is found, replace the entire switch and key assembly. Do not replace individual parts. • Do not exceed one million switching operations. Failure to comply with these instructions could result in death or serious injury. Maintenance frequency will be determined by the type of machinery, the frequency of operation, the application, and the local environment. Inspect for and correct the following: ROUTINE MAINTENANCE CHECKLIST Switch and key mounting. Mounting should √ be secure and permanent. Switch and key alignment. The key should √ move freely with no jamming in the switch during operation. Wear or mechanical damage. √ Correct electrical and mechanical switching √ function. Switch sealing. Ensure there are no liquids √ in switch enclosure. The complete safety switch assembly must √ be replaced after one million switch operations. PERFORM MECHANICAL FUNCTION TEST • Open and close protective guard several times to ensure key slides easily into switch head. PERFORM ELECTRICAL FUNCTION TEST • Close the protective guard and ensure switch locks. It must not be possible to open the protective guard when hazardous motion is present. • After the switch unlocks, open the protective guard. The hazardous motion must not start when the protective guard is unlocked or open. Honeywell • Sensing and Control 5 GK Solenoid Safety Interlock Switch PK 81591 ISSUE 5 Figure 7: Modes of Operation for 1NO - 1NC Configuration Sequence Protective Guard Condition Hazardous Motion Key Actuator Safety Circuit 1 Open 2 Closed 3 Closed 4 Closed Absent Unlocked Open Absent Locked Closed Present Locked Closed Unknown Locked Closed Absent Unlocked Open Off Off Off On Off On Off On On Off Solenoid State: Mechanical Lock Solenoid Lock Mechanical Lock Circuitry L2 L1 Safety Circuit S2 S1 21 S1 = Safety Switch S2 = Monitor Switch 1-5 = PCB Terminal Strip 13-14, 21-22 = Switch Terminals 22 21 22 Green 13 13 Monitor Circuit 21 22 Green S1 2 14 13 13 Release Signal S1 13 22 S1 13 13 14 22 3 1 L S1 13 L 13 L Red S2 14 Monitor Circuit 2 14 Release Signal Release Signal 5 4 5 5 4 Solenoid Solenoid Solenoid 21 Green 2 14 22 Monitor Circuit Red S2 Safety Circuit S2 S1 21 L 3 1 L 2 14 21 Green Red 4 5 4 Solenoid 13 14 Monitor Circuit 3 S2 22 L2 L1 Safety Circuit S2 S1 21 L Release Signal Release Signal 5 4 22 1 L 2 14 21 Green Red S2 14 Monitor Circuit 3 1 L 22 L2 L1 Safety Circuit S2 S1 21 L Red S2 14 22 L2 L1 Safety Circuit S2 S1 21 L 3 1 S1 L2 L1 5 Open Solenoid Dashed Line = Internal Switch Cavity Solenoid Lock Circuitry L2 L1 S2 S1 21 S1 = Safety Switch S2 = Monitor Switch 1-5 = PCB Terminal Strip 13-14, 21-22 = Switch Terminals 22 13 14 Green 13 21 Monitor Circuit 14 Green S1 2 22 13 13 21 Solenoid Dashed Line = Internal Switch Cavity Green LED Red LED Green S1 13 21 13 21 14 L 13 Lock Signal L Red S1 2 22 Monitor Circuit 3 1 L Red 5 4 13 Green Monitor Circuit 3 Lock Signal 5 4 22 L S2 14 Safety Circuit S2 S1 21 14 Green S1 2 22 13 1 L Red S2 14 21 2 22 Lock Signal 5 4 Solenoid Solenoid Solenoid On Off Monitor Circuit 3 S2 14 22 L2 L1 Safety Circuit S2 S1 21 L Lock Signal 5 4 Solenoid Off On 14 1 L 2 22 Lock Signal 5 4 Monitor Circuit 13 Red S2 14 22 L2 L1 Safety Circuit S2 S1 21 L 3 1 L Red S2 14 22 L2 L1 Safety Circuit S2 S1 21 L 3 1 S1 L2 L1 Safety Circuit On Off On Off Off On Figure 8: Terminal Strip Key 1. Green LED 2. Red LED 3. Ground 4. Solenoid 5. Solenoid Honeywell • Sensing and Control 6 GK Solenoid Safety Interlock Switch Issue 5 PK 81591 AUXILIARY RELEASE DESCRIPTION (FIGURE 5) LOCKING STRENGTH FEATURE IMPROPER OPERATION Do NOT use the auxiliary release for general maintenance, repair of the machine, or to start and stop the machine. Use in an emergency situation only. Failure to comply with these instructions could result in death or serious injury. IMPROPER OPERATION Do not exert over 1000 N (224 lb) extraction force on actuator key. Failure to comply with these instructions could result in death or serious injury. The auxiliary (or manual) release of the switch lock mechanism allows the protective guard to be opened. The auxiliary release is to be used in an emergency situation only, such as a power failure when the mechanical lock version is used. • Using a screwdriver, rotate the slotted screw as follows for the listed switch versions to release: − Clockwise for Head on Left, Mechanical Lock; Head on Right, Solenoid Lock. − Counterclockwise for Head on Left, Solenoid Lock; Head on Right, Mechanical Lock. LOCKING TYPES DESCRIPTION Mechanical Lock: Occurs by internal spring force when the protective guard is closed and the key is inserted. Applying voltage to the solenoid unlocks this version (or by actuating the auxiliary release when power failure occurs). IMPROPER INSTALLATION Ensure that unintentional power failure on solenoid lock versions does not cause an unsafe condition. Failure to comply with these instructions could result in death or serious injury. Solenoid Lock: Occurs by applying voltage to the solenoid after the protective guard is closed and the key is inserted. Removing the voltage to the solenoid unlocks the protective guard. The switch is equipped with a locking mechanism to prevent damage to the switch operating head. This mechanism is designed to withstand 1000 N (224 lb). If force over 1000 N is exerted on the actuator key, the mechanism will fracture and indicate an “open door” condition, requiring replacement of the entire switch. ELECTRICAL RATING A300 - AC15 Q300 - DC13 Ue (V) Ie (A) Ue (V) Ie (A) 120 240 6 3 24 125 250 2.9 0.55 0.27 Rated insulation voltage (Ui) = 600V Rated impulse withstand (Uimp) = 2500 V Rated thermal current (Ith) = 10 A Max. Rating of Short Circuit Protective Device = Class J Fuse, Rated 10 A, 600 V ENVIRONMENTAL RATING Sealing Temp. range Operating Storage IP68 Enclosure Type 1, 4, 6P, 12, 13 -25 C° to 40 °C (-13 °F to 104 °F) -40 °C to 120 °C (-40 °F to 248 °F) Shock 50 G per IEC 68-2-27 Vibration 10 G per IEC 68-2-6 SPECIFICATIONS Solenoid power Solenoid operating voltage Contact material Housing material Mechanical life 12 W 12 Vdc: +10 %, -20 % 24 Vdc: +10 %, -20 % 48 Vdc: +10 %, -20 % 24 Vdc: +10 %, -15 % 120 Vdc: +10 %, -15 % 240 Vdc: +10 %, -15 % Fine silver Zinc die cast One million operations Honeywell • Sensing and Control 7 GK Solenoid Safety Interlock Switch Issue 5 PK 81591 APPROVALS • UL file #E37138, E157416 • CSA certified • CE marked REGULATION COMPLIANCE • OSHA 29 CFR 1910.212 -- General Requirements for (Guarding of) All Machines. STANDARDS/DIRECTIVES COMPLIANCE • The forced disconnect mechanism on normally closed contacts conforms to IEC60947-5-1. • This product complies with Machinery Directive (89/392/EEC as amended by Directive 91/369/EEC) and complies with EN60947-5-1. REPLACEMENT KEYS Catalog Listing Description GKZ51 Straight Key GKZ52 90° Key GKZ53 Spring-Loaded Key: Up/Down GKZ54 Spring-Loaded Key: Left/Right WARRANTY/REMEDY Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell’s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer’s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell web site, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this printing. However, we assume no responsibility for its use. SALES AND SERVICE Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office or: E-mail: info.sc@honeywell.com Internet: www.honeywell.com/sensing Phone and Fax: Asia Pacific +65 6355-2828 +65 6445-3033 Fax Europe +44 (0) 1698 481481 +44 (0) 1698 481676 Fax Latin America +1-305-805-8188 +1-305-883-8257 Fax USA/Canada +1-800-537-6945 +1-815-235-6847 +1-815-235-6545 Fax Automation and Control Solutions Sensing and Control Honeywell 1985 Douglas Drive North Minneapolis, MN 55422 www.honeywell.com/sensing PK 81591 Issue 5 IL50 GLO Printed in USA January 2006 © 2006 Honeywell International Inc.
GKZ51 价格&库存

很抱歉,暂时无法提供与“GKZ51”相匹配的价格&库存,您可以联系我们找货

免费人工找货