0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GKZ72

GKZ72

  • 厂商:

    HONEYWELL(霍尼韦尔)

  • 封装:

  • 描述:

    LIMIT SWITCH

  • 数据手册
  • 价格&库存
GKZ72 数据手册
EXPLOSION PROOF SWITCHES Explosion proof switches Honeywell explosion proof switches are designed specifically for use in hazardous locations. To comply with explosion proof requirements, the flame path within the housing is designed to contain and cool the escaping hot gases that otherwise could cause an explosion outside the switch. Switches are available with UL/CSA for North America. See information below and product pages for details. In Europe, the usage is governed under the European Directive on Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres (94/9/EC) commonly referred to as the ATEX Directive. The BX, CX and GXE product families comply to the following ATEX Directive: EExd IIC T6 Category II 2 GD The 14CE100 product family complies to the following ATEX Directive: EExd IIC T6 Category II 2 G NEMA TYPE 7, CLASS I FLAMMABLE GASES OR VAPORS Type 7 enclosures are for use indoors in locations classified as Class I, Groups B, C, or D by the National Electrical Code. Group B — (only switches so noted in the order guides include this listing). Atmospheres containing hydrogen or manufactured gas. Group C — atmospheres containing diethyl ether, ethylene, or cyclopropane. Group D — Atmospheres containing gasoline, hexane, butane, naptha, propane, acetone, toluene or isoprene. Division 1 Locations in which hazardous agents are present under normal operating conditions. Division 2 Locations in which hazardous agents may be present only in case of accidental rupture or breakdown. All Honeywell listings covered in Division 1 are also covered in the same groups in Division 2. NEMA TYPE 9, CLASS II COMBUSTIBLE DUSTS Type 9 enclosures are for use in indoor locations classified as Class II, Groups E, F or G, as defined in the National Electrical Code. Group E — Atmospheres containing metal dust. Group F — Atmospheres containing carbon black, coal dust or coke dust. Group G — Atmospheres containing flour, starch or grain dust. ATEX EExd EExd Flameproof enclosure II c T6 Category II 2 Places with potentially explosive atmospheres, other than mines susceptible to fire damp Atmosphere may contain gases from groups A, B or C from table in EN50014, Annex A Maximum surface temperature of 85 °C (185 °F) Areas in which an explosion proof atmosphere is likely to occur www.honeywell.com/sensing G Gas could be present D Dust could be present 57 EXPLOSION PROOF SWITCHES 14CE100 Series Miniature Enclosed, Explosion Proof X ATEoved Switches r p ap The 14CE100 Series has been designed for use in explosive environments. It is approved to meet the requirements of the Low Voltage directive and is CE marked. The prewired construction allows for ease of installation where space is at a premium and external operating conditions can be difficult. Mechanical life: Sealing: 10 million IP65, NEMA 1, 3 IP67 , NEMA 1, 3, 4 12, 13 0 °C to 70 °C (32 °F to 158 °F) CE, PTB 98 ATEX 1064 X EExd IIC T6 Category II 2 G AC14 D300 DC13 R300 11,8 N max. 1,8 mm (0.71 in) max. 3,0 mm (0.118 in) min. 0,1mm (0.004 in) max. Standard Silver -*G Gold Harmonised CENELEC 4 x 0,75 mm2 cable Standard Boot sealed Operating temperature: Approvals: Operating force (OF): Pretravel (PT): Overtravel (OT): Differential travel (DT): Contacts: Connection: Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) Actuators S.P.D.T BROWN 2 GREEN/YELLOW BLUE 1 3 BLACK Top pin plunger 40,0 Max. 1,57 25,0 1.00 M4 ground screw 15,7 OP 0.62 Top roller plunger, parallel 16,0 Max. 0.63 1,8 PT 0.07 M4 ground screw Top roller plunger, perpendicular 40,0 Max. 1,57 25,0 1.00 M4 ground screw Ø 10,0 (0.39) Stainless steel plunger (2) Ø 5,1 (0.20) Mounting holes 49,0 Max. 1.93 31,4 1.24 1,8 PT 0.07 Ø 12,0 (0.47) x 5,0 (0.20) Hardened steel roller REFERENCE 14CE101-1 14CE101-2 14CE101-3 14CE101-4 14CE101-5 14CE101-6 14CE101-10 Boot sealed 1,80 Max. (0.07) PT 72,0 2,83 31,4 1.24 49,0 Max. 1.93 CABLE LENGTH 1 m (3.3 ft) 3 m (9.9 ft) 3 m (9.9 ft) Gold contacts 5 m (16.5 ft) 6 m (19.8 ft) 6 m (19.8 ft) Gold contacts 8 m (26.4 ft) 12 m (39.6 ft) 15 m (49.5 ft) 31,4 1.24 49,0 Max. 1.93 7,6 0.30 "L" REFERENCE 14CE102-1 14CE102-3 14CE102-3G 14CE102-5 14CE102-6 14CE102-6G 14CE102-8 14CE102-12 14CE102-15 Ø 7,1 (0.28) Stainless steel plunger Neoprene boot seal 58 14,0 0.55 72,0 2,83 7,6 0.30 24,9 (0.98) OP CABLE LENGTH 1 m (3.3 ft) 6 m (19.8 ft) 10 m (33.0 ft) (2) Ø 5,1 (0.20) Mounting holes 28,5 OP 1.11 "L" CABLE LENGTH 1 m (3.3 ft) 2 m (6.6 ft) 3 m (9.9 ft) 4 m (13.2 ft) 5 m (16.5 ft) 6 m (19.8 ft) 10 m (33.0 ft) 1,8 PT 0.07 (2) Ø 5,1 (0.20) Mounting holes 7,6 0.30 "L" 16,0 Max. 0.63 16,0 Max. 0.63 28,5 OP 1.11 59,0 2.32 40,0 Max. 1,57 25,0 1.00 REFERENCE 14CE118-1 14CE118-6 14CE118-10 www.honeywell.com/sensing CABLE LENGTH 1 m (3.3 ft) 3 m (9.9 ft) REFERENCE 14CE103-1 14CE103-3 EXPLOSION PROOF SWITCHES GXE Series Explosion Proof Limit Switches The GXE Series explosion proof limit switches are designed specifically for use in hazardous applications. The GXE enclosure is fully potted and has sealing protection of IP66/67 as per IEC/EN 60529. The entire GXE Series complies with the European Directive on Equipment and Protective Systems Intended for Use in Potentially Explosive Atmospheres (94/9/EC) commonly referred to as the ATEX Directive. Mechanical life: Sealing: Operating temperature: Approvals: 2 million IP66/67, EN 60529 -20 °C to 75 °C (-4 °F to 167 °F) CE, EN 50014, EN 50018, EN 50281-1-1 KEMA 00 ATEX 2103 X EExd IIC T6 Category II 2 GD AC15 DC13 Silver 5 metre, HO5VV-F, 3 x 0,75 mm2 cable X ATEoved r app Contacts: Connection: Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) BLUE BLACK BROWN Actuators OPTIONS GXE Series Side rotary roller lever Top roller plunger, parallel Overtravel min. (OT): 6,0 mm (0.0.236 in) Differential travel max. (DT): 0,5mm (0.020 in) Operating position max. (OP): 2,0 mm (0.079 in) Overtravel min. (OT): Differential travel max. (DT): Operating position max. (OP): 49° 8° 26° REFERENCE GXE51C REFERENCE GXE51A1B Operating force max. (OF): 16 N (3.6 lb) Top pin plunger Overtravel min. (OT): 6,0 mm (0.0.236 in) Differential travel max. (DT): 0,5mm (0.020 in) Operating position max. (OP): 2,0 mm (0.079 in) REFERENCE GXE51B www.honeywell.com/sensing 59 EXPLOSION PROOF SWITCHES The EX Series features the smallest UL listed housings available for use in hazardous locations. Flame paths within the housing cool exploding gases below the kindling temperature before they reach the explosive gases surrounding the housing. EX Series Standard Explosion Proof Switches Options available include single or double conduit connection. These switches are not sealed against liquids and should not be used where there will be liquid splash. If a weather sealed explosion proof switch is required please select from the CX or LSX/BX series. Actuators Sealing: Operating temperature: Approvals: Conduit: Contacts: Electrical ratings: A NEMA 1, 7 (Class I, Division I, Groups C, D) 9, (Class II, Division I, Groups E, F, G) Standard -40 °C to 71 °C (-40 °F to 160 °F) High 100 hr @ 400 °F UL, CSA ½ in - 14NPT Silver UL/CSA Rating: 15 A, 125, 250 or 480 Vac; /8 Hp, 125 Vac; ¼ Hp, 250 Vac; ½ A, 125 Vdc; ¼ A, 250 Vdc. 1 B UL/CSA Rating: 20 A, 125, 250 or 480 Vac; 10 A, 125 Vac “L”; 1 Hp, 125 Vac; 2 Hp, 250 Vac; ½ A, 125 Vdc; ¼ A, 250 Vdc. C UL/CSA Rating: D UL/CSA Rating: 10 A, 125 or 250 Vac; 0.3 A, 125 Vdc; 0.15 A, 250 Vdc . 10 A, 125, 250 or 480 Vac; ½ A, 125 Vdc; ¼ A, 250 Vdc. E UL Rating: Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) 1 A, 125 Vac. DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO) Side rotary actuated switches OPTIONS No lever Note: Levers are ordered separately (see pages 71-73 for details) Operating force max. (OF): Electrical rating A Electrical rating B Pretravel max. (PT): Overtravel max. (OT): Electrical rating A Electrical rating B Differential travel max. (DT): Electrical rating A Electrical rating B ACTUATION CW CCW CW 60 www.honeywell.com/sensing CONTACT SPDT SPDT SPDT 0,22 N m (31.25 in oz) 3,34 N to 8,90 N (0.75 lb to 2.0 lb) 5,56 mm (0.219 in) 8° 90° 25° 0,18 mm (0.007 in) 0.25° 0,3 mm (0.012 in) 4° ELECTRICAL RATING A A B REFERENCE EX-AR20 EX-AR230 EXA-AR20 EXPLOSION PROOF SWITCHES Roller lever DPDT, Preleaded with 0,91 m (3 ft) leadwire Operating force max. (OF): Clockwise (CW) Counter clockwise (CCW) Pretravel max. (PT): Overtravel max. (OT): Differential travel max. (DT): Sealing: ACTUATION CW CCW Roller material: Operating force max. (OF): Electrical rating A Clockwise (CW) Counter clockwise (CCW) Electrical rating B Pretravel max. (PT): Electrical rating A, B Clockwise (CW) Counter clockwise (CCW) Overtravel max. (OT): Electrical rating A Clockwise (CW) Counter clockwise (CCW) Electrical rating B Differential travel max. (DT): Electrical rating A Electrical rating B ACTUATION CW CCW CW/Class 1 Group B CCW/Class 1 Group B CW/High temperature CW CW/No mounting bracket CW/Nylon roller CW/No mounting bracket CONTACT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT SPDT CONTACT DPDT DPDT 2,22 N to 6,67 N (0.5 lb to 1.5 lb) 12,2 N (2.75 lb) 6,35 mm (0.250 in) 25° 2,77 mm (0.109 in) 4° NEMA Class 1 Group B ELECTRICAL RATING C C REFERENCE EXD-AR-3 EXD-AR30-3 Bronze Hermetically sealed 2,22 N to 5,56 N (0.5 lb to 1.25 lb) 11,1 N (2.5 lb) 3,34 N to 8,90 N (0.75 lb to 2.0 lb) 5,56 mm (0.219 in) 8° 1,65 mm (0.065 in) 3.5° 90° 25° 25° Operating force max. (OF): Clockwise (CW) Counter clockwise (CCW) Pretravel max. (PT): Clockwise (CW) Counter clockwise (CCW) Overtravel max. (OT): Differential travel max. (DT): Sealing: ACTUATION CW/3,2 m (10.5 ft) leadwire CCW/0,91 m (3 ft) leadwire CW/0,91 m (3 ft) leadwire CONTACT SPDT SPDT SPDT 2,22 N to 6,67 N (0.5 lb to 1.5 lb) 11,1 N (2.5 lb) 5,56 mm (0.219 in) 8° 1,65 N (0.065 in) 3.5° 25° 0,64 mm (0.025 in) NEMA Class 1 Group B ELECTRICAL RATING E E E REFERENCE EXH-AR3 EXH-AR33 EXH-AR7 0,18 mm (0.007 in) 0.25° 0,3 mm (0.012 in) 4° ELECTRICAL RATING A A A A A B B A A REFERENCE EX-AR EX-AR30 EX-AR800 EX-AR830 EX-AR400 EXA-AR EXA-AR62 EX-AR182 EX-AR141 2 Conduit openings CW or CCW actuation, no return spring, low operating force Operating force max. (OF): ACTUATION CW/CCW/No mounting bracket CONTACT SPDT 0,56 N (2 oz) ELECTRICAL RATING A REFERENCE EX-AR16 Maintained contact Operating force max. (OF): Pretravel max. (PT): Overtravel max. (OT): ACTUATION CW CONTACT SPDT 3,34 N (0.75 lb) 5,56 mm (0.219 in) 8° 90° ELECTRICAL RATING A REFERENCE EX-XR3 Operating force max. (OF): Electrical rating A Electrical rating B Electrical rating C Pretravel max. (PT): Electrical rating A, B Electrical rating C Overtravel max. (OT): Electrical rating A Electrical rating B, C Differential travel max. (DT): Electrical rating A Electrical rating B Electrical rating C CONTACT DPDT SPDT SPDT www.honeywell.com/sensing 2,22 N to 5,56 N (0.5 lb to 1.25 lb) 3,61 N to 8,90 N (0.8 lb to 2 lb) 2,22 N to 6,67 N (0.5 lb to 1.5 lb) 5,56 mm (0.219 in) 8° 6,35 mm (0.250 in) 90° 25° 0,18 mm (0.007 in) 0.25° 0,3 mm (0.012 in) 0.5° 2,77 mm (0.109 in) 4° ELECTRICAL RATING C B A REFERENCE 4EX1-3 2EX1 1EX1 61 EXPLOSION PROOF SWITCHES EX Series Side rotary actuated switches (continued) Overtravel plunger actuated switches Cross roller lever, rotated 90° Top pin plunger Operating force max. (OF): Pretravel max. (PT): Overtravel max. (OT Differential travel max. (DT): CW CONTACT SPDT 2,22 N to 5,56 N (0.5 lb to 1.25 lb) 5,56 mm (0.219 in) 8° 90° 0,18 mm (0.007 in) 0.25° ELECTRICAL RATING A REFERENCE EX-CR Rod lever OPTIONS Operating force max. (OF): Electrical rating A, C Electrical rating B Pretravel max. (PT): Electrical rating A Electrical rating B Electrical rating C Overtravel min. (OT): Electrical rating A Electrical rating B Electrical rating C Differential travel max. (DT): Electrical rating A Electrical rating B Electrical rating C No mounting bracket High temperature Low OF Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): CW/No mounting bracket 62 CONTACT SPDT 0,56 N (2 oz) 18° 40° ELECTRICAL RATING A REFERENCE EX-AR1613 13,34 N (3.0 lb) 8,90 N (2 lb) 1,98 mm (0.078 in) 1,27 mm (0.050 in) 3,96 mm (0.156 in) 4,78 mm (0.188 in) 3,18 mm (0.125 in) 3,48 mm (0.141 in) 0,10 mm (0.004 in) 0,23 mm (0.009 in) 1,52 mm (0.060 in) CONTACT SPDT SPDT SPDT SPDT ELECTRICAL RATING A A A B REFERENCE EX-Q EX-Q62 EX-Q400 EXA-Q Sealing NEMA Class 1 Group B Preleaded with 0,91 m (3 ft) leadwire www.honeywell.com/sensing CONTACT SPDT DPDT ELECTRICAL RATING A C REFERENCE EX-Q800 EXD-Q-3 EXPLOSION PROOF SWITCHES Boot sealed Operating force max. (OF): Electrical rating D Electrical rating B Pretravel max. (PT): Electrical rating D Electrical rating B Overtravel min. (OT): Electrical rating D Electrical rating B Differential travel max. (DT): Electrical rating D Electrical rating B Class 1 Group B CONTACT SPDT SPDT 13,34 N (3.0 lb) 15,57 N (3.5 lb) 1,98 mm (0.078 in) 2,77 mm (0.109 in) 4,78 mm (0.188 in) 3,18 mm (0.125 in) 0,10 mm (0.004 in) 0,23 mm (0.009 in) ELECTRICAL RATING D B REFERENCE EX-N15 EXA-N ELECTRICAL RATING A REFERENCE EX-AR50 Manually actuated Operating force max. (OF): CONTACT SPDT 11,1 N (2.5 lb) www.honeywell.com/sensing 63 EXPLOSION PROOF SWITCHES CX Series Weather Sealed Explosion Proof Switches X ATEoved r app CX switches, as are the LSX/BX Series, are built especially for outdoor use in hazardous atmospheres. These enclosures are constructed to withstand the pressure of an internal explosion. O-ring seals make the enclosure weatherproof but are outside of required flame paths so explosion proof requirements are maintained. As factory assembled, all basic switches operate on clockwise and counterclockwise rotation. The actuating mechanism can be field adjusted for CW or CCW operation only. Analog output, 4 mA to 20 mA, is available. Basic switches operate nearly simultaneously in multiple switch devices. Shafts of devices without shaft restoring force can be rotated through 360°. Sealing: NEMA UL listed 1, 3, 4, 4X, 6, 6P, 7, 9 and 13 Class I, Div. 1, Groups B (16CX, 24CX, 26CX, and 84CX only), C and D; and Class II, Div. 1, Groups E, F and G Class I, Div. 1, Groups B (16CX, 24CX, 26CX, and 84CX only), C and D; and Class II, Groups E, F and G –25 °C to 85 °C (–13 °F to 185 °F) UL, CSA CX-E only ATEX EExd IIC T6 Category II 2 GD Aluminium 80CX Bronze ¾ in - 14NPT A, C, D Silver F Gold CSA certified Operating temperature: Approvals: Housing: Conduit: Contacts: Actuators Electrical Ratings: A UL/CSA Rating: L96 15 A, 120, 240 or 480 Vac, ind. and res 1 /8 Hp, 120 Vac; ¼ Hp, 240 Vac 0.5 A, 125 Vdc, 0.25 A, 250 Vdc, res C UL/CSA Rating: L59 10 A, 120 or 240 Vax, ind. and res 0.3 A, 125 Vdc, 0.15 A, 250 Vdc, res D UL/CSA Rating: L22 1 A, 120 Vax, ind. and res F UL/CSA Rating: L22 1 A, 125 Vac G Analog Current Output (4 mA to 20 mA) 12.5 Vdc to 40 Vdc Switching options: SPDT Single Pole, Double Throw Snap action contacts (1NC/1NO) DPDT Double Pole, Double Throw Snap action contacts (2NC/2NO) Analog position sensing specifications (Electrical rating “G”) Current output: Voltage compliance range: Maximum load resistance: Current signal output: Span: Null: 64 www.honeywell.com/sensing 4 mA to 20 mA 12.5 Vdc to 40 Vdc RL, Max., –V Supply - 12.5 20 mA 4 mA to 20 mA Adjustable from 15° to 90° of angular rotation 4 mA position may be set at any angular position EXPLOSION PROOF SWITCHES Operating characteristics Basic Switch Type BZ BA DT Pretravel (max.)* 15° 15° 30° Differential Travel (max.) 10° 10° 25° Overtravel (min.)* 90° 90° 75° Operating Torque (max.) 11.1 in lb/1,25 N m * May be modified in field to suit application requirements. Note: Levers are ordered separately (see pages 71-73 for details) HS 30° 20° 75° Notes: Add the letter “A” to listings with side mounting holes tapped 5/16 (8). Example: 11CX2A Add the letter “B” to listings with thru mounting holes tapped 3/8-24 (4). Example: 11CX2B Add the letter “C” to listings for low temperature (-40 °C/°F) applications. Example: 11CX2C Add “D01” to specify a “direct-couple” listing with 3/8 in. dia by 3/4 in. long flatted shaft. Example: 11CX2-D01 Add the letter “E” to listings for European Atex approvals. Example: 11CX2E For Replacement Basic Switch Assemblies, change the first number in the listing to “9”. Example: 11CX2 becomes 91CX2 Short housing OPTIONS HOUSING SIZE Short Short Short Short Short Short BASIC SWITCHES BZ (2) BZ (2) BZ (2) BZ (2) BZ (2) BZ (2) CONTACT SPDT SPDT SPDT SPDT SPDT SPDT ELECTRICAL RATING A A A A F F SHAFT RESTORING FORCE TO CENTRE With Without With Without With Without Standard Standard BZ (4) BZ (4) REFERENCE 11CX2 11CX12 11CX2E 11CX12E 1172CX2 1172CX12 SPDT SPDT A A With Without 21CX4 21CX14 UL listed for Class I, Group B (hydrogen atmospheres) Standard housing HOUSING SIZE Standard Standard Short Short Standard BASIC SWITCHES DT (2) DT (2) HS (2) HS (2) HS (4) CONTACT DPDT DPDT SPDT SPDT SPDT ELECTRICAL RATING C C D D D SHAFT RESTORING FORCE TO CENTRE With Without With Without With REFERENCE 24CX2 24CX12 16CX2 16CX12 26CX4 Analog output, 4 mA to 20 mA HOUSING SIZE Short Short Short Standard Standard BASIC SWITCHES None None None BZ (2) BZ (2) CONTACT N/A N/A N/A SPDT SPDT ELECTRICAL RATING G G G A, G A, G SHAFT RESTORING FORCE TO CENTRE With Without Without With Without REFERENCE 18CX0 18CX10 18CX10E 281CX2 281CX12 Bronze housing for use in corrosive environments 80CX switches have rugged bronze housings which are resistant to salt water and other corrosive environments. They comply with the NEMA 4X requirement for protection against corrosion, in addition to NEMA enclosure standards met by other CX switches. O-ring seals make the enclosure weatherproof, but are outside of required flame paths, maintaining explosion-proof requirements. HOUSING SIZE Standard Standard Standard Standard BASIC SWITCHES BZ (2) BZ (4) BZ (4) DT (2) www.honeywell.com/sensing CONTACT SPDT SPDT SPDT DPDT ELECTRICAL RATING A A A C SHAFT RESTORING FORCE TO CENTRE With With Without With REFERENCE 81CX2 81CX4 81CX14 84CX2 65 EXPLOSION PROOF SWITCHES LSX/BX Series weather sealed, explosion proof limit switches are for use either indoor or outdoors in hazardous atmospheres. They are completely sealed and designed for use in explosive gas/dust environments. LSX/BX Series Weather sealed explosion proof switches BX X ATE LSX/BX products meet the sealing standards of NEMA 1, 3, 4, 6, 7, 9 and 13. BX products are also sealed to IP67 standard and are ATEX approved (see specifications below). All heads are field adjustable at 90° increments. Heads with side rotary actuators can be adjusted for clockwise and counter clockwise operation. d rove app Actuators Sealing: LSX NEMA 1, 3, 4, 6, 7 (Class 1, Division 1, Groups B, C, D), 9 (Class 2, Division 1, Groups E, F, G), 13 IP67, NEMA 1, 3, 4, 6, 7 (Class 1, Division 1, Groups B, C, D), 9 (Class 2, Division 1, Groups E, F, G), 13 BX Rotary actuated switches Approvals: LSX/BX UL, CSA* BX only EExd IIC T6 category II 2 GD, SIRA 00ATEX 1037X Contacts: Electrical ratings A, B Silver Electrical rating C Gold Switching options: SPDT DPDT Single Pole, Double Throw Double Pole, Double Throw Snap action contacts (1NC/1NO) Snap action contacts (2NC/2NO) Operating torque max.: Standard Low Standard Low Standard Low 0,45 N m (4.0 in lb) 0,19 Nm (1.7 in lb) 15° 9° 60° 66° Differential travel max. (DT): Standard SPDT Standard DPDT Low SPDT Low DPDT 5° 7° 3° 4° Pretravel max. (PT): SPDT Double Break DPDT Double Break * Applies only to listings with ½ in NPT or ¾ in NPT Electrical ratings 10 amps continuous carry. Circuits on any one pole must be the same polarity. ac Volts Pilot duty: 600 Vac, 720 VA A SPDT NEMA A600 B DPDT NEMA B600 C SPDT/DPDT Amps at 0.35 Power Factor Vac Make Break 120 60 6 240 30 3 480 15 1.5 600 12 1.2 120 30 3 240 15 1.5 480 7.5 0.75 600 6 0.60 250 Vac or 60 Vdc, 0.050 amp max. Overtravel min. (OT): Note: Levers are ordered separately (see pages 71-73 for details) dc Volts Pilot duty: 240 Vdc, 30 watts A SPDT B DPDT C SPDT/DPDT 66 Make and Break Amps Vdc Inductive Resistive 120 0.25 0.8 240 0.15 0.4 120 0.25 0.8 240 0.15 0.4 250 Vac or 60 Vdc, 0.050 amp max. www.honeywell.com/sensing EXPLOSION PROOF SWITCHES OPTIONS Side rotary Maintained contact 39,6 1.56 50,8 2.00 Operating torque max.: Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 19,0 0.75 25,4 1.00 31,9 1.25 LSX Operating temperature: 49,3 1.94 Maintained Maintained Maintained CONTACT SPDT DPDT DPDT -1 °C to 121 °C (30 °F to 250 °F) CONDUIT ½ in - 14NPT ¾ in - 14NPT ½ in - 14NPT ELECTRICAL RATING A B B REFERENCE LSXN3K LSXN4L LSXN7L BX (ATEX approved) LSX Operating temperature: Low DT SPDT DPDT 0,45 N m (4.0 in lb) 65° 20° 30° 35° CONTACT SPDT SPDT SPDT SPDT DPDT DPDT DPDT SPDT -12 °C to 121 °C (10 °F to 250 °F) CONDUIT ½ in - 14NPT 20 mm ¾ in - 14NPT ½ in - 14NPT ¾ in - 14NPT 20 mm ½ in - 14NPT ½ in - 14NPT ELECTRICAL RATING A A A C B B B A CONDUIT ½ in - 14NPT 20 mm ¾ in - 14NPT ELECTRICAL RATING A A B REFERENCE LSXA3K LSX4A3K LSXA4K LSXA3E LSXA4L LSX4A4L LSXA7L LSXP3K Operating temperature: Maintained Maintained CONTACT SPDT DPDT -40 °C to 70 °C [ -40 °F to 158 °F] CONDUIT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A B REFERENCE BXN3K BXN4L Top rotary BX (ATEX approved) Operating temperature: CONTACT SPDT SPDT DPDT -40 °C to 70 °C [ -40 °F to 158 °F] REFERENCE BXA3K BX4A3K BXA4L LSX Operating temperature: Low Low Low Low DT/Low torque DT/Low torque torque torque CONTACT SPDT DPDT SPDT DPDT -1 °C to 121 °C (30 °F to 250 °F) CONDUIT ½ in - 14NPT ¾ in - 14NPT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A B A B REFERENCE LSXH3K LSXH4L LSXR3K LSXR4L Operating temperature: CONTACT SPDT SPDT DPDT SPDT DPDT -40 °C to 70 °C [ -40 °F to 158 °F] CONDUIT ½ in - 14NPT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A C C REFERENCE BXR3K BXR3E BXR4S 0,28 N m (2.5 in lb) 25° 100° 10° 12° LSX Operating temperature: BX (ATEX approved) Low torque Low torque Low torque Operating torque max.: Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): CONTACT SPDT DPDT -1 °C to 121 °C (30 °F to 250 °F) CONDUIT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A B REFERENCE LSXB3K LSXB4L Centre neutral Operating torque max. : Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 0,45 N m (4.0 in lb) 18° 57° 10° LSX Operating temperature: CONTACT DPDT DPDT -1 °C to 121 °C (30 °F to 250 °F) CONDUIT ¾ in - 14NPT 20 mm ELECTRICAL RATING B B REFERENCE LSXM4N LSX4M4N www.honeywell.com/sensing 67 EXPLOSION PROOF SWITCHES LSX/BX Series (continued) Plunger actuated switches BX X d ATpE rove ap Top plungers Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): SPDT DPDT 17,79 N (4 lb) 1,78 mm (0.07 in) 4,83 mm (0.19 in) 0,38 mm (0.015 in) 0,51 mm (0.02 in) OPTIONS Top pin plunger Top roller plunger Head can be set at 90° increments for cam or slide actuation Operating point: 58,5 mm ± 0,76 mm (2.305 in ± 0.03 in) LSX Operating temperature: CONTACT SPDT SPDT DPDT CONDUIT ½ in - 14NPT 20 mm ¾ in - 14NPT -12 °C to 93 °C (10 °F to 200 °F) ELECTRICAL RATING A A B REFERENCE LSXC3K LSX4C3K LSXC4L Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F] CONTACT SPDT DPDT DPDT REFERENCE BX4C3K BXC4L BX4C4L ELECTRICAL RATING A B B Operating temperature: CONDUIT ½ in - 14NPT 20 mm ¾ in - 14NPT -40 °C to 70 °C [ -40 °F to 158 °F] CONTACT SPDT REFERENCE BX4D3K CONDUIT 20 mm Min. operating point Max. 65,7 operating point (2,59) 72,0 (2,83) 65,66 mm to 72,01 mm (2.585 in to 2.835 in) LSX Operating temperature: CONTACT SPDT 68 CONDUIT ½ in - 14NPT ELECTRICAL RATING A -12 °C to 93 °C (10 °F to 200 °F) REFERENCE LSXD3K LSX4D3K LSXD4L Operating temperature: 21,6 (0.85) Operating point: ELECTRICAL RATING A A B BX (ATEX approved) Top pin plunger, adjustable 7,9 (0.31) 68,6 mm ± 1.00 mm (2.700 in ± 0.04 in) LSX CONTACT SPDT SPDT DPDT BX (ATEX approved) CONDUIT 20 mm ¾ in - 14NPT 20 mm Operating point: -12 °C to 93 °C (10 °F to 200 °F) REFERENCE LSXV3K www.honeywell.com/sensing ELECTRICAL RATING A EXPLOSION PROOF SWITCHES Wobble actuated switches OPTIONS Side plungers Plastic rod Operating force max. (OF): Pretravel max. (PT): Overtravel min. (OT): Differential travel max. (DT): 26,69 N (6 lb) 2,54 mm (0.10 in) 4,83 mm (0.19 in) 1,14 mm (0.045) OPTIONS Side pin plunger 39,6 1.56 50,8 2.00 19,0 0.75 25,4 1.00 49,3 1.94 Operating point: 33,0 mm (1.30 in) LSX Operating temperature: CONTACT SPDT DPDT CONDUIT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A B -12 °C to 93 °C (10 °F to 200 °F) REFERENCE LSXE3K LSXE4L Operating force max. (OF): Pretravel max. (PT): 2,78 N (10 oz) 25,4 mm (1.0 in) LSX Operating temperature: CONTACT SPDT DPDT Side roller plunger CONDUIT ½ in - 14NPT ¾ in - 14NPT ELECTRICAL RATING A B -12 °C to 93 °C (10 °F to 200 °F) REFERENCE LSXJ3K-7A LSXJ4L-7A Roller may be set in vertical or horizontal position for cam or slide actuation Cat whisker Operating point: 44,1 mm (1.735 in) LSX Operating temperature: CONTACT SPDT CONDUIT ½ in - 14NPT ELECTRICAL RATING A -12 °C to 93 °C (10 °F to 200 °F) REFERENCE LSXF3K Operating force max. (OF): Pretravel max. (PT): BX (ATEX approved) Operating temperature: -40 °C to 70 °C [ -40 °F to 158 °F] LSX CONTACT SPDT REFERENCE BXF3K Operating temperature: CONDUIT ½ in - 14NPT ELECTRICAL RATING A CONTACT SPDT CONDUIT ½ in - 14NPT www.honeywell.com/sensing ELECTRICAL RATING A 1,39 N (5 oz) 50,8 mm (2.0 in) -12 °C to 93 °C (10 °F to 200 °F) REFERENCE LSXK3K-8A 69 70 www.honeywell.com/sensing LEVERS Levers REFERENCE Separate levers must be ordered with side rotary types. The table provides a cross reference between product families and the lever order/ reference numbers. The following pages describe the levers. Illustrations are for reference only. Exact mounting drawings and dimensions are available from your local sales office or from the website below. Levers lock in any position, 360° around the shaft. Rollers may be mounted on the front or back of the lever. All levers are supplied with cap screws. Explosion proof switches Because of explosion proof requirements, only nylon rollers or other non sparking material should be selected. BX/LSX, CX and EX plunger and cat whisker types are of non sparking material. Do not mix or substitute. Specification (unless stated otherwise) Lever radius/length: Roller Diameter: Roller Width: -EX 1.5 in (38,1 mm) 0.75 in (19,1 mm) 0.25 in (6,35 mm) 0.312 in (7,92 mm) Note: Not all levers are compatible with all switches 6PA57 6PA63 6PA69 6PA80 6PA82 6PA102 6PA144 GLZ51A GLZ51B GLZ52A GLZ52B GLZ54J GLZ55B LSZ51 LSZ51A LSZ51B LSZ51C LSZ51D LSZ51W LSZ51Y LSZ52 LSZ52A LSZ52B LSZ52C LSZ52D LSZ52J LSZ52K LSZ52M LSZ52N LSZ52W LSZ52Y LSZ53A LSZ53B LSZ53D LSZ53E LSZ53P LSZ53S LSZ53U LSZ54 LSZ54M LSZ54N LSZ54R LSZ54V LSZ55 LSZ55A LSZ55B LSZ55C LSZ55D LSZ55W LSZ55Y LSZ61 LSZ67AA LSZ68 6PA5-EX 6PA127-EX 6PA130-EX 6PA131-EX 6PA136-EX 6PA138-EX 6PA142-EX 6PA204-EX ROLLER MATERIAL Aluminium Stainless steel Spring rod Steel Steel Nylon Ball bearing Nylon Steel Nylon Steel Aluminium Steel N/A Nylon Steel Nylon Steel Rubber Rubber N/A Nylon Steel Nylon Steel Nylon Nylon Nylon Nylon Rubber Rubber Nylon Steel Steel Nylon Steel Nylon Steel N/A Aluminium Stainless steel Spring wire Cable N/A Nylon Steel Nylon Steel Rubber Rubber Nylatron Rubber Delrin Bronze Nylon Bronze Bronze Aluminium Nylon Bronze Nylon GLA LIMIT SWITCH SERIES HDLS LS2 LS EXPLOSION PROOF SERIES BX/LSX CX EX ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! ! Stainless steel levers LS2Z51A LS2Z51B LS2Z52A LS2Z52B LS2Z54N Nylon Steel Nylon Steel Steel ! ! ! ! ! www.honeywell.com/sensing ! ! ! ! ! ! ! 71 LEVERS OPTIONS * denotes lever suitable for Explosion Proof Series switches One way roller lever Standard fixed lever MOUNTED ON REFERENCE LSZ51* Nylon roller Metal roller Front Front LSZ51A* LSZ51B Nylon roller Metal roller Back Back LSZ51C* LSZ51D Nylon roller Metal roller Front Front GLZ51A GLZ51B Bronze roller Nylon roller Front Front 6PA5-EX* 6PA127-EX* Ball bearing roller Front 6PA144 Without roller Adjustable rod RADIUS/LENGTH Hub only Bronze roller, clockwise RADIUS/LENGTH REFERENCE 1.56 in (39,6 mm) 6PA130-EX* Bronze roller, counter clockwise 1.56 in (39,6 mm) 6PA142-EX* Perpendicular (cross) roller lever Offset fixed lever REFERENCE LSZ54* Aluminium rod 5.5 in (139,7 mm) LSZ54M* Stainless steel rod 13.0 in (330,2 mm) LSZ54N Aluminium, spring only 12.0 in (305 mm) LSZ54R Aluminium, flexible cable 4.8 in (122 mm) LSZ54V Aluminium rod 7.9 in (200 mm) GLZ54J Stainless steel rod 13.0 in (330,2 mm) 6PA63 Aluminium rod 5.3 in (134,1 mm) 6PA136-EX* Adjustable rod, nylon roller MOUNTED ON REFERENCE LSZ55* Nylon roller Metal roller Back Back LSZ55A* LSZ55B Nylon roller Metal roller Front Front LSZ55C* LSZ55D Metal roller Front GLZ55B Without roller RADIUS/LENGTH REFERENCE 1.81 in (46,0 mm) 6PA131-EX* Bronze roller Yoke lever Aluminium rod, nylon roler RADIUS/LENGTH REFERENCE 12.5 in (317,5 mm) 6PA204-EX* Adjustable lever Spring rod Operating radius/length: -EX 1.5 in to 3.5 in (38,1 mm to 88,9 mm) 1.69 in to 3.0 in (42,9 mm to 76,2 mm) Adjustable lever, without roller MOUNTED ON REFERENCE LSZ52 Nylon roller Metal roller Back Back LSZ52A* LSZ52B Nylon roller Metal roller Nylon roller, Ø 1.0 in (25,4) x 0.5 in (12,7 mm) Nylon roller, Ø 1.5 in (38,1) Nylon roller, Ø 2.0 in (50,8) Nylon roller, 0.5 in wide (12,7 mm) Front Front LSZ52C* LSZ52D Front Front Front Front LSZ52J* LSZ52K* LSZ52M* LSZ52N* Nylon roller Metal roller Back Back GLZ52A GLZ52B Nylon roller, Ø 1.0 in (25,4) x 0.5 in (12,7 mm) Front Nylon roller Metal roller MOUNTED ON Front/Back Front/Back REFERENCE LSZ53A LSZ53B Metal roller Front/Front LSZ53D Nylon roller Back/Front LSZ53E* Metal roller Nylon roller Back/Back Back/Back LSZ53P LSZ53S* Metal roller Back/Front LSZ53U Metal roller Metal roller Nylon roller Front/Back Front/Front Front/Front 6PA80 6PA82 6PA102 RADIUS/LENGTH 12.0 in (305 mm) REFERENCE LSZ68 Ø 0.17 in (4,32 mm) 7.4 in (188 mm) 6PA69 6PA138-EX* Note: 72 Ø 0.25 in (6,35 mm) Not all levers are compatible with all switches www.honeywell.com/sensing LEVERS * denotes lever suitable for Explosion Proof Series switches Stainless steel levers **Large rubber roller, adjustable lever Flexible loop Roller Diameter: Roller Width: 0.75 in (19,1 mm) 0.25 in (6,35 mm) OPTIONS Standard fixed lever Flexible loop RADIUS/LENGTH 6.0 in (152 mm) REFERENCE LSZ61 REFERENCE LSZ52W Ø 1.6 in X 0.50 in wide roller (40,6 mm X 12,7 mm) Hand operated button Ø 2 in X 0.50 in wide roller (50,8 mm X 12,7 mm) LSZ52Y Operating radius/length: 1.5 in (38,1 mm) Nylon roller MOUNTED ON Front REFERENCE LS2Z51A* Stainless steel roller Front LS2Z51B **Conveyor roller arm Adjustable lever Ø 1.5 in (38,1 mm) REFERENCE 6PA57 **Large rubber roller, fixed lever Operating radius/length: Plastic roller, 1.5 in Ø X 3.8 in long (38,1 mm X 96,5 mm) 6.78 in (172,2 mm) REFERENCE LSZ67AA NOTICE ** Ø 1.6 in X 0.50 in wide roller (40,6 mm X 12,7 mm) Ø 2 in X 0.50 in wide roller (50,8 mm X 12,7 mm) REFERENCE LSZ51W LSZ51Y Large rubber rollers and conveyor roller arm Because of the lever’s mass, the limit switch should be mounted with the lever facing down. This will enable gravity to help restore the switch to the free position. Operating radius/length: 1.5 in to 3.5 in (38,1 mm to 88,9 mm) Nylon roller MOUNTED ON Back REFERENCE LS2Z52A* Stainless steel roller Back LS2Z52B Adjustable rod **Large rubber roller, fixed offset lever Operating radius/length: Ø 1.6 in X 0.50 in wide roller (40,6 mm X 12,7 mm) Ø 2 in X 0.50 in wide roller (50,8 mm X 12,7 mm) 13 in (330,2 mm) REFERENCE LS2Z54N REFERENCE LSZ55W LSZ55Y Note: Not all levers are compatible with all switches www.honeywell.com/sensing 73 POWER RELAYS Solder/Plug-In Terminal, DPDT 2,6 [0.10] SZR-MY Series Power Relay 8 - O 1,2 [0.05] x 3 Holes Current rating (SZR-MY2): Current rating (SZR-MY4): Contact resistance: Contact material: Agency approvals: Operate time: Release time: Ambient temperature: Ambient humidity: Switching options: 5A 3A 50 mOhm max. Fine silver UL, CE, CSA 20 ms max. 20 ms max. -25 °C to 75 °C (-13 °F to 167 °F) 45% RH to 85% RH DPDT, 4PDT 6,3 [0.25] SZR-MY Series relays have a small package design for multiple application needs. Relays are available in two configurations: DPDT with a 5 A load and 4PDT with a 3 A load. One standard and three options are available: LED indicator, internal surge protection diode, and LED indicator/diode protection. 0,5 [0.02] Max. 36,0 [1.42] Max. 28,0 [1.10] 0,5 [0.02] SZR-MY Series general-purpose power relays are designed for a wide range of applications including power, as well as logic control, for factory machines and control panels. Max. 21,5 [0.85] 6,0 [0.24] Standard COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc MAX. CONTACT RATING 250 Vac/5 amp 250 Vac/5 amp 125 Vdc/1 amp 125 Vdc/1 amp REFERENCE SZR-MY2-1-AC110-120V SZR-MY2-1-AC220V SZR-MY2-1-DC12V SZR-MY2-1-DC24V MAX. CONTACT RATING 250 Vac/5 amp 250 Vac/5 amp 125 Vdc/1 amp 125 Vdc/1 amp REFERENCE SZR-MY2-N1-AC110-120V SZR-MY2-N1-AC220V SZR-MY2-N1-DC12V SZR-MY2-N1-DC24V MAX. CONTACT RATING 125 Vdc/1 amp REFERENCE SZR-MY2-D1-DC24V LED Indicator COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc Diode Protection MY2 Series COIL INPUT VOLTAGE 24 Vdc OPTIONS LED Indicator/Diode Protection COIL INPUT VOLTAGE 24 Vdc 3,3 [0.13] 1,0 [0.04] Standard, PCB Terminal, DPDT 6,3 [0.25] 0,5 [0.02] Max. 36,0 [1.42] COIL INPUT VOLTAGE 110/120 Vac 220/240 Vac 24 Vdc 74 Max. 28,0 [1.10] 0,5 [0.02] 3,5 [0.14] Max. 21,5 [0.85] 6,0 [0.24] MAX. CONTACT RATING 250 Vac/5 amp 250 Vac/5 amp 125 Vdc/1 amp REFERENCE SZR-MY2-1P-AC110-120V SZR-MY2-1P-AC220V-240V SZR-MY2-1P-DC24V www.honeywell.com/sensing MAX. CONTACT RATING 125 Vdc/1 amp REFERENCE SZR-MY2-X1-DC24V POWER RELAYS Solder/Plug-In Terminal, 4PDT MY4 Series 2,6 [0.10] OPTIONS 14 - O 1.2 [0.05] x 3 Holes Max. 28,0 [1.10] 6,3 [0.25] 0,5 [0.02] 6,3 [0.25] 3,5 [0.14] 0,5 [0.02] Max. 36,0 [1.42] COIL INPUT VOLTAGE 110/120 Vac 220/240 Vac 24 Vdc Max. 21,5 [0.85] 6,0 [0.24] Standard 5,0 [0.20] MAX. CONTACT RATING 250 Vac/3 amp 250 Vac/3 amp 125 Vdc/0.6 amp Max. 21,5 [0.85] 0,5 [0.02] Max. 36,0 [1.42] Max. 28,0 [1.10] 0,5 [0.02] 3,3 [0.13] 1,0 [0.04] Standard, PCB Terminal, 4PDT REFERENCE SZR-MY4-1P-AC110-120V SZR-MY4-1P-AC220V-240V SZR-MY4-1P-DC24V COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc MAX. CONTACT RATING 250 Vac/3 amp 250 Vac/3 amp 125 Vdc/0.6 amp 125 Vdc/0.6 amp REFERENCE SZR-MY4-1-AC110-120V SZR-MY4-1-AC220V SZR-MY4-1-DC12V SZR-MY4-1-DC24V MAX. CONTACT RATING 250 Vac/3 amp 250 Vac/3 amp 125 Vdc/0.6 amp 125 Vdc/0.6 amp REFERENCE SZR-MY4-N1-AC110-120V SZR-MY4-N1-AC220V SZR-MY4-N1-DC12V SZR-MY4-N1-DC24V MAX. CONTACT RATING 125 Vdc/0.6 amp REFERENCE SZR-MY4-D1-DC24V LED Indicator COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc Diode Protection COIL INPUT VOLTAGE 24 Vdc LED Indicator/Diode Protection COIL INPUT VOLTAGE 24 Vdc www.honeywell.com/sensing MAX. CONTACT RATING 125 Vdc/0.6 amp REFERENCE SZR-MY4-X1-DC24V 75 POWER RELAYS SZR-LY Series Power Relay LY2 Series OPTIONS Operate time: Release time: Ambient temperature: Ambient humidity: Switching options: 10 A 50 mOhm max. Silver cadium oxide UL, CE, CSA 18,000 operations/hour (mechanical) 1,800 operations/hour (electrical) 25 ms max. 25 ms max. -25 °C to 70 °C (-13 °F to 158 °F) 45% RH to 85% RH DPDT, 4PDT Max. 28,0 [1.10] REFERENCE SZR-LY2-1P-AC110-120V SZR-LY2-1P-DC24V Solder/Plug-In Terminal, DPDT 14 - O 3,0 [0.12] 3,0 [0.12] Max. 36,0 [1.42] 6,4 [0.26] Max. 21,5 [0.85] Standard COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp 125 Vdc/2 amp REFERENCE SZR-LY2-1-AC110-120V SZR-LY2-1-AC220V SZR-LY2-1-DC12V SZR-LY2-1-DC24V MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp 125 Vdc/2 amp REFERENCE SZR-LY2-N1-AC110-120V SZR-LY2-N1-AC220V SZR-LY2-N1-DC12V SZR-LY2-N1-DC24V MAX. CONTACT RATING 125 Vdc/2 amp REFERENCE SZR-LY2-D1-DC24V LED Indicator COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc Diode Protection COIL INPUT VOLTAGE 24 Vdc LED Indicator/Diode Protection COIL INPUT VOLTAGE 24 Vdc 76 www.honeywell.com/sensing MAX. CONTACT RATING 125 Vdc/ 2 amp REFERENCE SZR-LY2-X1-DC24V Max. 28,0 [1.10] Current rating: Contact resistance: Contact material: Agency approvals: Operating frequency: MAX. CONTACT RATING 250 Vac/10 amp 125 Vdc/2 amp 5,75 [0.23] One standard and three options are available: LED indicator, internal surge protection diode, and LED indicator/diode protection. COIL INPUT VOLTAGE 110/120 Vac 24 Vdc Max. 21,5 [0.85] 4,5 [0.18] 5,0 [0.20] SZR-LY Series relays break 10 A loads are ideal for control panels that require stable and reliable relays. 1,0 [0.04] Max. 36,0 [1.42] 0,5 [0.02] SZR-LY Series general-purpose power relays are designed for a wide range of applications including power, as well as logic control, for factory machines and control panels. 5,75 [0.23] 2,0 [0.08] 0,5 [0.02] Standard, PCB Terminal, DPDT POWER RELAYS LY4 Series OPTIONS Solder/Plug-In Terminal, 4PDT Max. 41,5 [1.63] 4,5 [0.18] Max. 28,0 [1.10] 14 - O 3.0 Holes 5,0 [0.20] Max. 28,0 [1.10] 2,0 [0.08] 1,0 [0.04] Max. 36,0 [1.42] 0,5 [0.02] 0,5 [0.02] Standard, PCB Terminal, 4PDT Max. 36,0 [1.42] 3,0 [0.12] 6,4 [0.25] Max. 41,5 [1.63] Standard COIL INPUT VOLTAGE 110/120 Vac 220/240 Vac 24 Vdc MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp REFERENCE SZR-LY4-1P-AC110-120V SZR-LY4-1P-AC220V-240V SZR-LY4-1P-DC24V COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp 125 Vdc/2 amp REFERENCE SZR-LY4-1-AC110-120V SZR-LY4-1-AC220V SZR-LY4-1-DC12V SZR-LY4-1-DC24V MAX. CONTACT RATING 250 Vac/10 amp 250 Vac/10 amp 125 Vdc/2 amp 125 Vdc/2 amp REFERENCE SZR-LY4-N1-AC110-120V SZR-LY4-N1-AC220V SZR-LY4-N1-DC12V SZR-LY4-N1-DC24V MAX. CONTACT RATING 125 Vdc/2 amp REFERENCE SZR-LY4-D1-DC24V LED Indicator COIL INPUT VOLTAGE 110/120 Vac 220 Vac 12 Vdc 24 Vdc Diode Protection COIL INPUT VOLTAGE 24 Vdc LED Indicator/Diode Protection COIL INPUT VOLTAGE 24 Vdc www.honeywell.com/sensing MAX. CONTACT RATING 125 Vdc/2 amp REFERENCE SZR-LY4-X1-DC24V 77 POWER RELAYS MY2 Series Socket LY2 Series Socket 22,0 [0.87] 30,0 [1.18] 25,0 [0.99] 47,0 [1.85] 2 - M4 2 - O 4,5 [0.18] Holes 2,5 [0.10] 18,0 [0.70] 26,0 [1.02] 14,5 [0.57] 30,0 [1.18] 25,0 [0.99] Max. 61,0 [2.40] Max. 61,0 [2.40] POLES 2 REFERENCE SZX-SMF-08N 2 - O 4,5 [0.18] Holes 14-M3.5x8 18,0 [0.70] 26,0 [1.02] 2-M4 36,0 ± 0,2 [1.42 ± 0.008] 8,0 [0.31] Max. 45,5 [1.79] 25,0 [0.99] 30,0 [1.18] 3,4 [0.13] 68,0 [2.68] 62,0 ± 0,1 [2.44 ± .004] 2-M3 or 2-M4 2 - O 6,0 [0.24] 7,0 [0.28] 69,0 ± 0,3 [2.72 ± 0.01] 4,5 [0.18] 26,0 [1.02] 35,2 [1.39] 15,6 [0.61] 45,0 [1.77] 3,9 [0.15] 4,2 [0.17] REFERENCE SZX-SLF-08N LY4 Series Socket 6,0 [0.24] 62,0 [2.44] POLES 2 35,5 [1.40] MY4 Series Socket TYPE Rail socket Max. 78,5 [3.09] TYPE Rail socket 3,0 [0.12] 25,0 ± 0,2 [0.99 ± .008] 4,2 [0.17] 62,0 ± 0,1 [2.44 ± .004] 45,0 [1.77] 15,6 [0.61] 3,0 [0.12] 2-M3 or 2-M4 2 - O 4,5 [0.18] Holes 26,0 [1.02] 19,0 [0.75] 8,0 [0.31] 26,0 [1.02] 35,2 [1.39] 62,0 [2.44] 4,2 [0.17] 3,9 [0.15] 67,0 [2.64] 6,0 [0.24] Max. 61,0 [2.40] Max. 66,0 [2.60] Max. 30,0 [1.18] TYPE Rail socket 78 POLES 4 REFERENCE SZX-SMF-14N TYPE Rail socket www.honeywell.com/sensing POLES 4 REFERENCE SZX-SLF-14 SAFETY SWITCHES Electromechanical Safety Switches Honeywell is a worldwide leader in advanced switching and sensing technology - especially in the area of industrial safety. We offer both electromechanical safety switches and electronic safety sensors as well as safety control modules for safety applications in all categories of risk. Customers can count on our diverse product line to meet all of their machine safety applications. Honeywell products meet or exceed European machine safety standards and have been approved (CE, BG, INRS) for use in Europe for more than 25 years. As North America moves toward harmonizing with global standards, machine builders and users can confidently turn to Honeywell for compliant machine safety solutions. Our products are designed to meet all applicable OSHA and ANSI standards. Refer to pages 8 and 9 for more information about degrees of protection and electrical ratings. Protective Guarding Cable Pull Switches Protective guarding around a dangerous machine can be achieved with tamper-resistant safety switches. Safety switches incorporate positive opening operation such that even a welded contact will be mechanically broken and a stop signaled. These switches monitor the position of moveable guards and doors, which are used to safeguard access to equipment and provide protection from ejected pieces, chips, projectiles or oil. These safeguards require a relatively low investment and provide reliable protection if they are regularly checked and maintained. Cable-pull limit switches serve as a readily accessible means of emergency stop for applications. These cable-pull devices are visible, accessible and easy to use and they immediately open the emergency stop circuit when activated. WARNING ! IMPROPER INSTALLATION • Consult with local safety agencies and their requirements • when designing a machine-control link, interface and all control elements that affect safety. Strictly adhere to all installation instructions. Failure to comply with these instructions could result in death or serious injury. www.honeywell.com/sensing 79 SAFETY SWITCHES Selection Guide for Electromechanical Safety Switches Approvals Housing Material Sealing Dimensions Electrical Rating Actuator Operating Temperature CSA UL CE Metal BG From Plastic IEC IP NEMA (USA) HeightxWidthxDepth mm (in) ˚C (˚F) GSC GKM Series 67 1, 12, 13 66 1, 4, 12, 13 69,4 x 34,0 x 16,0 (2.73 x 1.34 x 0.63) To Straight or 90˚ key AC15, DC13 A300 -25 (-13) 85 (185) -25 (-13) 85 (185) AC15, DC13 A300 GSD 66 1, 12, 13 GSE 66 1, 4, 12, 13 83,0 x 65,0 x 30,0 (3.27 x 2.56 x 1.18) GK 67 1, 4, 12, 13 121,6 x 42,0 x 42,6 (4.79 x 1.65 x 1.68) Straight, 90˚, Spring key AC15, DC13 A600 -25 (-13) 85 (185) GKL/R 67 1, 4, 6P, 12, 13 149,0 x 110,0 x 48,8 (5.85 x 4.33 x 1.92) Straight, 90˚, Spring key AC15, DC13 A600 -25 (-13) 85 (185) 1CPS 67 1, 4, 12, 13 99,1 x 276,2 x 65,2 (3.9 x 10.87 x 2.57) Linear AC15, DC13 A600 -25 (-13) 85 (185) 2CPS GSS 83,0 x 30,5 x 30,0 (3.27 x 1.2 x 1.18) 67 1, 4, 12, 13 165,1 x 325,9 x 79,8 (6.5 x 12.75 x 3.14) Left and/or Right AC15, DC13 A600 -40 (-40) 85 (185) Hinge Straight or 90˚ AC15, DC13 A600 AC15, DC13 A300 GK GKM GSS 80 www.honeywell.com/sensing SAFETY SWITCHES Switching Options 1NC/ 2NC/ 1NC/ 2NC/ 1NC 2NC 1NO 2NO 1NO 2NO Slow Action Make Break Before Make Before Break 1NC/ 1NO 1NC/ 2NC/ 2NC/ 3NC/ 4NC 1NO 1NO 2NO 1NO Special Features Page Number Snap Action Termination Gold Contacts (Low Energy Options) M12 or Cable Daisy chain capability 82 85 Conduit 85 86 Standard Conduit 87 Conduit 89 Conduit Integral LED option 93 Conduit High intensity multi-cluster LED 95 2CPS GKL/GKR 1CPS www.honeywell.com/sensing 81 SAFETY SWITCHES GKM Series Global Miniature Safety Key Operated Switch Used alone as Category 1 safety components or, in conjunction with other safety switches and our complete range of safety relays, it is possible to construct comprehensive protection schemes with Category 2, 3 or 4 compliance. The preleaded versions allow rapid fit, easy cable routing and function testing which cut costs dramatically in OEM applications. Simple upgrade guarding solution for End User applications. Low energy basic switches are rated as follows: Operating Voltage Ue 1 Vdc to 60 Vdc or 1 Vac to 125 Vac Operating Current Ie 1 mA to 50 mA Example of catalog listing using a low energy basic switch - GKMA19 Mechanical life: Sealing: Operating temperature: Approvals: > 1 million IP66/67, EN 60529, NEMA 1, 12, 13 -25 °C to 85 °C (-13 °F to 185 °F) CE, UL, CSA AC15 B300 DC13 Q300 Contacts: Silver Low energy Gold plated Switching options: Slow action contacts 1 Normally Closed/1 Normally Open, Break Before Make 1NC/1NO, BBM - GKMF 1NC/1NO, BBM, low energy - GKMA, B, C, D 3 4 1 Brown Blue 3 2 1 White 2 3 2 4 Black 1 4 2 Normally Closed 2NC - GKMF 2NC, low energy - GKMA, B, C, D 3 2 4 3 2 1 Brown Blue 3 1 White 2 4 Black 1 4 Electrical ratings: Designation & Utilization Category AC15 AC15 AC15 AC14 A600 A300 B300 D300 DC13 DC13 Q300 R300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 240 V 380 V 480 V 500 V 600 V 6 3 1,9 1,5 1,4 1,2 6 3 3 1.5 0,6 0,3 125 V 250 V 0,55 0,27 0,22 0,1 Of key slot 90˚ - Key shown in optional actuating positions 16 max. / 0.63 Body style 'B' 17,2 / 0.67 1,6 / 0.058 12,8 / 0.504 Key slot 22,0 / 0.866 10 max. / 0.30 2 X mounting holes for M4 or #8 screws. Counter bored both sides 08,3 X 4,5 deep. 0.366 0.177 82 www.honeywell.com/sensing 32 max. / 1.26 37,4 / 1.47 2,3 / 0.69 34 max. / 0.34 VA rating Make Break 7200 720 7200 720 3600 360 432 72 69 28 69 28 SAFETY SWITCHES KEY STYLE OPTIONS Side exit cable Side exit M12 dc micro-change connector Straight key 45 / 1.77 2 + max. / 0.945 3,5 / 0.138 12,8 / 0.504 2,5 / 0.093 CABLE LENGTH 1m 1m 2m 2m 2m 2m 3m 3m 3m 3m CONTACT 2NC, low energy 1NC/1NO, BBM, low energy 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy REFERENCE GKMA17 GKMA19 GKMA23 GKMA26 GKMA27 GKMA29 GKMA33 GKMA36 GKMA37 GKMA39 Face 'A' 21,3 / 0.638 CONTACT 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy REFERENCE GKMC03 GKMC06 GKMC07 GKMC09 15 / 0.59 6,4 min. / 0.252 22 / 0.866 2 holes for M4 or #8 screws REFERENCE GKZ51M Stainless steel Bottom exit M12 dc micro-change connector 90° key Bottom exit cable 2 holes for M4 or #8 screws with 45˚ C' SK X 2,1 deep 0.083 14 max. / 0.55 Face 'A' CONTACT 1NC/1NO, BBM 2NC, low energy 1NC/1NO, BBM, low energy CABLE LENGTH 1m 1m 1m 1m 2m 2m 2m 2m 3m 3m 3m 3m CONTACT 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy REFERENCE GKMB13 GKMB16 GKMB17 GKMB19 GKMB23 GKMB26 GKMB27 GKMB29 GKMB33 GKMB36 GKMB37 GKMB39 REFERENCE GKMD03 GKMD07 GKMD09 22 / 0.866 6,4 min. / 0.252 Dual exit M12 dc micro-change connector 24 max. / 0.945 Stainless steel CONTACT 1NC/1NO, BBM 2NC 2NC, low energy 1NC/1NO, BBM, low energy 12,8 / 0.504 32 max. / 1.25 REFERENCE GKZ52M REFERENCE GKMF03 GKMF06 GKMF07 GKMF09 www.honeywell.com/sensing 83 SAFETY SWITCHES GSS Series Hinge Mount Safety Limit Switch The Hinge Mount Safety Limit Switch is designed for use on machine access doors as an alternative solution to key operated interlocks and safety limit switches. When the access door is opened, a follower pin (not supplied) slides down the slot in the actuator lever, forcing the actuator lever to rotate and positively open the NC safety circuit to shut off the machine. Closing the access door rotates the actuator lever to the reset position, closing the NC safety contacts. The Hinge Mount Safety Limit Switch minimizes alignment problems because it may be offset-mounted from the hinge point of the door. The tamper-resistant design and the positive opening contacts provide a higher level of safety than the conventional spring-driven limit switches often used to monitor door position. Low Energy Switching In today’s demanding age of low energy controls, electromechanical switches are frequently used to interface directly with safety relays, PLCs and other low energy devices. To accommodate this requirement GSS offers a new gold plated contact version of the standard basic switch. This improves reliability of switching at low currents and voltages by protecting the contact surfaces from contamination during operation or storage prior to use. Standard silver contacts have a disadvantage in that the contact surface may tarnish under certain environmental conditions, e.g. in the presence of moisture. Low energy basic switches are rated as follows: Operating Voltage Ue 1 Vdc to 60 Vdc or 1 Vac to 125 Vac 1 mA to 50 mA Operating Current Ie Example of catalog listing using a low energy basic switch - GSCB33S2. Switching options: GSC/D Snap action contacts (1NC/1NO) 13 14 21 22 Zb Slow action contacts (1NC/1NO) BBM GSE Slow action contacts (4NC) 12 21 22 31 32 4Y 41 42 Slow action contacts (2NC/2NO) BBM 11 12 21 22 22 21 11 2Y, 2X Zb 13 14 Slow action contacts (2NC) 11 34 44 Slow action contacts (3NC/1NO) BBM 12 2Y 21 33 43 11 12 21 22 31 32 43 44 3Y, 1X 22 Electrical ratings: Designation & Utilization Category 84 AC15 AC15 AC15 AC14 A600 A300 B300 D300 DC13 DC13 Q300 R300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 240 V 380 V 480 V 500 V 600 V 6 3 1,9 1,5 1,4 1,2 6 3 3 1.5 0,6 0,3 125 V 250 V 0,55 0,27 0,22 0,1 www.honeywell.com/sensing VA rating Make Break 7200 720 7200 720 3600 360 432 72 69 28 69 28 SAFETY SWITCHES ACTUATED SWITCHES GSC Metal body GSD Plastic body EN 50047 Safety Standard Rotated 90° to the left from center 22 / 0.87 20 / 0.78 24,75 / 0.97 Rotated 90° to the right from center 104 / 4.09 70 / 2.76 45 / 1.77 3/ 0.12 180 MIN R 2,15 / 0.08 55 / 2.16 GSC - Metal body GSC - Metal body 30,5 / 1.20 14,5 / 0.57 3,5 / 0.138 30 / 1.18 CONTACT 1NC/1NO 1NC/1NO, BBM 2NC 2NC, low energy CONDUIT ½ in NPT ½ in NPT ½ in NPT 20 mm REFERENCE GSCA01S1 GSCA03S1 GSCA06S1 GSCC36S1 GSD - Plastic body conduit thread 19,8 / 0.78 ø 23 / ø 0.9 Mechanical life: Sealing: (GSC) (GSD) Operating temperature: Approvals: up to 1 million IP 66 NEMA 1, 4, 12, 13 NEMA 1, 12, 13 -25 °C to 85 °C (-13 °F to 185 °F) IEC/EN 60947-5-1 AC15 A300 DC13 Q300 UL, CSA, BG CONTACT 1NC/1NO, BBM 2NC 1NC/1NO, BBM 2NC 1NC/1NO CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm REFERENCE GSDA03S1 GSDA06S1 GSDB03S1 GSDB06S1 GSDC01S1 CONTACT 1NC/1NO 1NC/1NO, BBM 2NC 2NC, low energy CONDUIT ½ in NPT ½ in NPT ½ in NPT PG 13,5 REFERENCE GSCA01S3 GSCA03S3 GSCA06S3 GSCB36S3 GSD - Plastic body CONTACT 1NC/1NO, BBM 2NC 1NC/1NO, BBM 2NC 1NC/1NO CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm REFERENCE GSDA03S3 GSDA06S3 GSDB03S3 GSDB06S3 GSDC01S3 Rotated 90° either direction from center 5,1 / 0.20 11,5 / 0.45 2/ 0.08 45 / 1.77 70 / 2.76 90 min. 90 min. 12,5 / 0.49 28 / 24,8 / 0.97 GSC - Metal body CONTACT 1NC/1NO 1NC/1NO, BBM 2NC 2NC, low energy CONDUIT ½ in NPT ½ in NPT ½ in NPT PG 13,5 REFERENCE GSCA01S2 GSCA03S2 GSCA06S2 GSCB36S2 GSD - Plastic body CONTACT 1NC/1NO, BBM 2NC 1NC/1NO, BBM 2NC 1NC/1NO CONDUIT ½ in NPT ½ in NPT PG 13,5 PG 13,5 20 mm REFERENCE GSDA03S2 GSDA06S2 GSDB03S2 GSDB06S2 GSDC01S2 www.honeywell.com/sensing 85 SAFETY SWITCHES GSE EN 50047 Compatible Safety 3 Conduit Metal Standard 12,5 / 0.49 ACTUATED SWITCHES Rotated 90° to the left from center 42 / 1.65 40 / 1.57 22 / 0.87 20 / 0.79 24,75 / 0.97 104 / 4.09 70 / 2.76 45 / 1.77 3/ 0.12 R 2,15 / 0.08 60 / 2.37 13,75 / 0.54 12 / 0.47 30 / 1.18 2,5 / 0.1 52 / 2.05 57 / 2.24 4/ 0.16 CONTACT 2NC/2NO, BBM 3NC/1NO, BBM 4NC, low energy 65 / 2.56 conduit thread CONDUIT ½ in NPT ½ in NPT 20 mm REFERENCE GSEA44S1 GSEA46S1 GSEC41S1 23,8 / 0.94 ø 23 / ø 0.9 Mechanical life: up to 1 million Sealing: IP 66, NEMA/UL 1, 4, 12, 13 Operating temperature: -25 °C to 85 °C (-13 °F to 185 °F) Approvals: IEC/EN 60947-5-1 AC15 A300 DC13 Q300 UL, CSA, BG Rotated 90° either direction from center 5,1 / 0.20 11,5 / 0.45 2/ 0.08 45 / 1.77 70 / 2.76 90 min. 90 min. 12,5 / 0.49 28 / CONTACT 2NC/2NO, BBM CONDUIT ½ in NPT 24,8 / 0.97 REFERENCE GSEA44S2 Rotated 90° to the right from center 180 CONTACT 2NC/2NO, BBM 86 MIN CONDUIT ½ in NPT REFERENCE GSEA44S3 www.honeywell.com/sensing SAFETY SWITCHES GK Series Dual Entry Key Operated Safety Interlock Switch The GK Series is designed specifically for use on machines where key removal brings the machine to an immediate safe condition. It provides enhanced operator safety when added to hinged or sliding guard doors, screens and protective covers on enclosures. The GK Series is especially well suited for large door applications, typically in the automotive plant floor environment. Its heavy duty construction withstands harsh industrial environments where rugged, long-term durability is required. Nearly 1000 options are available in a simple to understand part number tree. A safety lockout device is also available for use with the GK Series. The lockout device (GKZL2) is specifically designed to prevent a key from being inserted either manually, or by the access door being closed while maintenance personnel are working on the machine. When inserted, the lockout device can accommodate up to four padlocks to prevent unauthorised removal of the device. Mechanical life: up to 15 million Sealing: IP 67, NEMA/UL type 1, 4, 12,13 Operating temperature: -25 °C to 85 °C (-13 °F to 185 °F) Approvals: CE, CSA, UL AC15 A300/A600 DC13 Q300 Contacts: Silver Low energy Gold Switching options: Snap action contacts (1NC/1NO) Snap action contacts (2NC/2NO) 13 Zb 21 13 14 11 12 23 24 21 22 14 22 Slow action contacts (1NC/1NO), BBM 22 21 Slow action contacts (2NC) 21 22 11 12 2Y Zb 13 14 Slow action contacts (2NC/2NO), BBM Slow action contacts (3NC/1NO) 11 12 11 12 21 22 21 22 31 32 2y,2x 13 14 23 24 3y,1x 43 44 Slow action contacts (4NC) 11 12 21 22 31 32 41 42 4y Electrical ratings: Designation & Utilization Category AC15 AC15 AC15 AC14 A600 A300 B300 D300 DC13 DC13 Q300 R300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 240 V 380 V 480 V 500 V 600 V 6 3 1,9 1,5 1,4 1,2 6 3 3 1.5 0,6 0,3 125 V 250 V 0,55 0,27 0,22 0,1 www.honeywell.com/sensing VA rating Make Break 7200 720 7200 720 3600 360 432 72 69 28 69 28 87 SAFETY SWITCHES GK Series (continued) Head orientation OPTIONS Opening to front and top 42 / 1.65 32 / 1.26 8/ 0.32 9/ 0.35 31 / 1.22 45,7 1.80 121,6 / 4.79 Opening to right and top 35 / 1.38 60 / 2.36 82 / 3.23 75,9 / 2.99 42,6 / 1.68 ø 5,3 / 0.21 7,3 / 0.29 30 / 1.18 5,3 / 0.21 Standard CONDUIT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT PG 13,5 PG 13,5 PG 13,5 20 mm 20 mm 20 mm 20 mm 20 mm 20 mm 20 mm 20 mm CONTACT 1NC/1NO 1NC/1NO 1NC/1NO 4NC 2NC/2NO, BBM 2NC/2NO, BBM 3NC/1NO, BBM 3NC/1NO, BBM 2NC/NO 4NC, low energy 3NC/1NO, BBM, low energy 1NC/1NO, BBM 1NC/1NO, BBM 2NC 2NC/2NO, BBM 1NC/1NO, BBM 2NC 2NC/2NO, BBM 1NC/1NO 1NC/1NO 1NC/1NO 2NC/NO 4NC, low energy 3NC/1NO, BBM, low energy 2NC Single LED indicator KEY 90° Up-down None 90° Straight 90° Straight 90° Straight None None Straight 90° None Straight 90° 90° 90° Straight 90° None None None None None REFERENCE GKBA1L7 GKBA1L8-F11* GKBA1LX GKBA10L7 GKBA14L6 GKBA14L7 GKBA16L6 GKBA16L7 GKBA2L6 GKBA30LX GKBA36LX GKBA3L6 GKBA3L7 GKBA6LX GKBB14L6 GKBB3L7 GKBB6L7 GKBC14L7 GKBC1L6 GKBC1L7 GKBC1LX GKBC2LX GKBC30LX GKBC36LX GKBC6LX Single LED indicator CONDUIT CONTACT 1/2 NPT 2NC/2NO, BBM 1/2 NPT 1NC/1NO KEY Straight 90° None None Straight Straight 90° Side-side None None None None None None REFERENCE GKCA1L6 GKCA1L7 GKCA1LX GKCA6LX GKCA10L6 GKCA14L6 GKCA14L7 GKCA14L9 GKCA30LX GKCA36LX GKCC1LX GKCC6LX GKCC30LX GKCC36LX KEY 90° REFERENCE GKDA14L7 Double LED indicator CONDUIT CONTACT 1/2 NPT 2NC/2NO, BBM www.honeywell.com/sensing REFERENCE GKCA14M6 22 / 0.87 Single LED indicator CONTACT 1NC/1NO 1NC/1NO 1NC/1NO 2NC 4NC 2NC/2NO, BBM 2NC/2NO, BBM 2NC/2NO, BBM 4NC, low energy 3NC/1NO, BBM, low energy 1NC/1NO 2NC 4NC, low energy 3NC/1NO, BBM, low energy KEY straight Opening to left and top * fluorocarbon seal CONDUIT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 1/2 NPT 20 mm 20 mm 20 mm 20 mm 88 CONDUIT CONTACT 1/2 NPT 2NC/2NO, BBM KEY Straight 90° REFERENCE GKCA14P6 GKCA1P7 Double LED indicator CONDUIT CONTACT 1/2 NPT 2NC/2NO, BBM KEY 90° REFERENCE GKDA14P7 SAFETY SWITCHES GKL/GKR Series Dual Entry Solenoid Key Operated Safety Interlock Switch The GKR (head to the right) and GKL (head to the left) products offer the user an unrivalled range of standard options. The GKR/GKL product is a key actuated device incorporating a key trapping mechanism. The switch is used on machinery where instant stop and access to the machinery is either impossible (due to the momentum of the machine) or impractical (due to tool or machine damage or scrapped product if the current machine cycle is interrupted). The switch incorporates an optional manual override feature which allows removal of the key for emergency access. Over 1000 options are available in a simple to understand part number tree. A safety lockout device is also available for use with the GKR/GKL Series. The lockout device (GKZL2) is specifically designed to prevent a key from being inserted either manually, or by the access door being closed while maintenance personnel are working on the machine. When inserted, the lockout device can accommodate up to four padlocks to prevent unauthorised removal of the device. Mechanical life: up to 1 million Sealing: IP 68, NEMA/UL type 1, 4, 6P, 12,13 Operating temperature: -25 °C to 40 °C (-13 °F to 104 °F) Approvals: CE, CSA, UL AC15 A300/A600 DC13 Q300 Contacts: Silver Low energy Gold-plated Switching options: Snap Action Type 11NC/1NO Direct Opening 13 14 21 22 Zb Slow Acting Type 3 1NC/1NO, Break before make (BBM) 21 Type 14/15 2NC/2NO, Break before make (BBM) 11 12 21 22 22 2Y, 2X Zb 13 14 33 34 43 44 2 Slow Acting Type 36 3NC/1NO, Break before make (BBM),low energy Type 40 4NC 11 12 21 22 21 22 31 32 31 32 4Y 41 42 43 44 11 3Y, 1X Type 44 2NC/2NO, Break before make (BBM) 11 12 21 22 2Y,2X 33 34 43 44 12 Type 46 3NC/1NO, Break before make (BBM) 11 12 21 22 31 32 43 44 3Y,1X www.honeywell.com/sensing 89 SAFETY SWITCHES GKL/GKR Series (continued) Key: Type 6 Type 9 Type X Straight Side - side, spring loaded No key Latching mechanism: Type A Mechanical (solenoid unlock with screwdriver) Mechanical (without override) Electrical (solenoid unlock with screwdriver) Type B Type S OPTIONS Opening to front and top 9/ 0.35 Solenoid voltage: Type 2 Type 4 24 Vdc 120 Vac Electrical ratings: Designation & Utilization Category AC15 AC15 AC15 AC14 A600 A300 B300 D300 DC13 DC13 Q300 R300 IEC 60947-5-1/EN 60947-5-1 Rated operational current le (A) at rated operational voltage Ue 120 V 240 V 380 V 480 V 500 V 600 V 6 3 1,9 1,5 1,4 1,2 6 3 3 1.5 0,6 0,3 125 V 250 V 0,55 0,27 0,22 0,1 VA rating Make Break 7200 720 7200 720 3600 360 432 72 69 28 69 28 Left 1/2 in - NPT buna-n seals CONTACT TYPE 3 (1NC/1NO, BBM) 40 (4NC) 46 (3NC, BBM) KEY None None None LATCHING TYPE A A A SOLENOID VOLTAGE 24 Vdc 24 Vdc 24 Vdc REFERENCE SOLENOID VOLTAGE 24 Vdc 24 Vdc REFERENCE GKLE3LXA2 GKLE40LXA2 GKLE46LXA2 Right 1/2 in - NPT buna-n seals 32,5 / 1.28 19 / 0.75 33 / 1.30 CONTACT TYPE 40 (4NC) 46 (3NC, BBM) 31 / 1.22 43,7 / 2 x 7,3 / 1.72 0.29 2 x ø 5,3 / 0.21 75 / 2.95 2 x 5,3 / 0.21 100 / 3.94 105,3 / 4.13 110 / 4.33 20 / 0.79 90 43 / 1.69 48,8 / 1.92 65 / 2.56 100 / 3.94 110 / 4.33 www.honeywell.com/sensing KEY None None LATCHING TYPE A A GKRE40LXA2 GKRE46LXA2 SAFETY SWITCHES Opening to left and top Opening to right and top 26 / 1.02 12 / 0.47 Left 1/2 in - NPT buna-n seals Right 1/2 in - NPT buna-n seals CONTACT TYPE 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) KEY None None None None None None None LATCHING TYPE A A S S A A S SOLENOID VOLTAGE 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc LATCHING TYPE A A S S A A A S S SOLENOID VOLTAGE 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 24 Vdc 120 Vac 24 Vdc 120 Vac REFERENCE GKRE3MXA2 GKRE3MXA4 GKRE3MXS2 GKRE3MXS4 GKRE36MXA2 GKRE36MXA4 GKRE36MXS2 20 mm - buna-n seals CONTACT TYPE 1 (1NC/1NO) 1 (1NC/1NO) 1 (1NC/1NO) 1 (1NC/1NO) 3 (1NC/1NO, BBM) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) KEY None None None None None None None None None CONTACT TYPE 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 3 (1NC/1NO, BBM) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) KEY None None None None None None None None LATCHING TYPE A A S S A A S S SOLENOID VOLTAGE 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 120 Vac LATCHING TYPE A A S S S A A S S B SOLENOID VOLTAGE 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc 24 Vdc 120 Vac 24 Vdc 120 Vac 24 Vdc REFERENCE GKLE3PXA2 GKLE3PXA4 GKLE3PXS2 GKLE3PXS4 GKLE36PXA2 GKLE36PXA4 GKLE36PXS2 GKLE36PXS4 20 mm - buna-n seals REFERENCE GKRG1MXA2 GKRG1MXA4 GKRG1MXS2 GKRG1MXS4 GKRG3MXA2 GKRG36MXA2 GKRG36MXA4 GKRG36MXS2 GKRG36MXS4 CONTACT TYPE 1 (1NC/1NO) 1 (1NC/1NO) 1 (1NC/1NO) 1 (1NC/1NO) 3 (1NC/1NO, BBM) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 36 (3NC/1NO, BBM, low energy) 44 (2NC/2NO, BBM) www.honeywell.com/sensing KEY Non None None None None None None None None None REFERENCE GKLG1PXA2 GKLG1PXA4 GKLG1PXS2 GKLG1PXS4 GKLG3PXS2 GKLG36PXA2 GKLG36PXA4 GKLG36PXS2 GKLG36PXS4 GKLG44PXB2 91 SAFETY SWITCHES Keys for GK and GKL/GKR switches Straight key 49,8 / 1.96 8,5 / 0.33 Locking slider bolt with actuating key 77 / 3.03 20 / 0.79 2x ø 5,3 / 0.21 14 / 0.55 15 / 0.59 3x HOLE PROVIDED FOR LOCKOUT 19,0 / .75 3/ 0.12 REFERENCE GKZ56 90° key 8,5 / 0.33 14 / 0.55 49,8 / 1.96 2 x ø 5,3 / 0.21 40 / 1.57 52 / 2.05 7,0 ±,7 / .28 ±.03 REFERENCE GKZ57 4x ø 5,1 / .20 4,93 / .194 26,97 / 36,8 / 1.062 1.45 14,0 / .55 41,81 ±,76 / 1.646 ±.030 Spring-loaded key: up/down 115,87 / 4.562 140,0 ±,7 / 5.51 ±.03 12,04 / .474 13,5 / 0.53 18,5 / 0.73 17,8 / 0.70 37,10 ±1,52 / 1.460 ±.060 26,77 ±1,52 / 1.054 ±.060 8,5 / 0.33 0°key rotation REFERENCE GKZ71 180° key rotation REFERENCE GKZ73 90° key rotation REFERENCE GKZ72 270° key rotation REFERENCE GKZ74 2 X ø 5,3 / 0.21 84,9 / 3.34 40 / 30 / 1.57 1.18 14 / 0.55 REFERENCE GKZ58 Spring-loaded key: left/right 8,5 / 0.33 84,9 / 3.34 2 X ø 5,3 / 14 / 0.55 0.21 20,5 / 0.81 18,5 / 0.73 13,5 / 0.53 30 / 1.18 40 / 1.57 REFERENCE GKZ59 92 www.honeywell.com/sensing SAFETY SWITCHES CPS Series Cable Pull Safety Switch CPS Series Cable Pull Safety Switches provide a readily accessible emergency stop signal. This is a costeffective means compared to using multiple emergency stop push-buttons. (Cable Pull Safety Switches are not, however, to be used as a means of personnel safeguarding. They may be used to prevent further injury or damage to equipment when used for emergency stop signaling.) The CPS Series Cable Pull Safety switch is designed to provide emergency stop protection for exposed conveyor and assembly lines. The internal mechanism latches on both slackened cable (push) and pulled cable. This capability also enhances productivity by eliminating nuisance stops due to variations in temperature, stretch of cable over time, and other application variables. The 1CPS is intended for use in applications where the cable span is 76 m (250 ft) or shorter. It is an economical solution for shorter runs or zone protection typical to automated systems. The 2CPS series is intended for use in very long cable runs of 152 m (500 ft) or shorter, such as long conveyor lines found in warehouses. The CPS complies with: Low Voltage Directive 73/23/EEC, as amended by directive 93/68/EEC; Machinery Directive 98/37/EEC only as the directives relate to the components being used in a safety function; IEC/EN 60947-1; IEC/EN 60947-5-1; IEC/EN 60947-5-5. Mechanical life: 1 000 000 Sealing: IP67, NEMA 1, 4, 12,13 Operating temperature: 1CPS -25 °C to 80 °C (-13 °F to 176 °F) 2CPS -40 °C to 80 °C (-40 °F to 176 °F) Approvals: AC15 A300 DC13 Q300 1CPS UL, CSA 2CPS UL, CSA, BG Contacts: 1CPS Silver 1CPS, Low energy Gold plated 2CPS Gold plate over silver Switching options: 1CPS 2CPS 1NC/1NO 21 22 13 14 N/A 2NC/2NO 21 22 21 22 21 22 21 22 13 14 13 14 13 14 13 14 21 22 11 12 21 22 11 12 13 14 21 22 13 14 21 22 11 12 11 12 11 12 11 12 21 22 21 22 21 22 21 22 3NC/1NO 4NC 2CPS contact block mounting: 1 2 1 To housing Removable with heavy duty terminals 2 I I 1CPS indicator Light Code: 2CPS indicator Light Code: No letter A B No letter A B www.honeywell.com/sensing No indicator provided 24 Vdc red LED 120 Vac red LED No indicator provided 24 Vdc red multi-cluster LED 120 Vac red multi-cluster LED 93 SAFETY SWITCHES CPS Series (continued) 1CPS 6,35 [0.25] B 152,4 [6.0] 81,28 [3.2] 1CPS Cable Pull Switch SLACK 88,9 [3.5] TENSIONED 33,02 [1.3] RUN RESET OFF 99,06 [3.9] 172,72 [6.8] 76,2 [3.0] 4X Ø 7,11 Ø 0.28 50,8 [2.1] 12,7 [0.5] 117,42 [4.623] A 65,20 [2.567] 56,79 [2.236] 50,83 [2.001] 3X 25,4 [1.0] 2X 26,67 [1.050] A B C D 25,4 [1.00] C 25,4 [1.00] D Fully extended Optional indicator Conduit thread (3 total) Mounting pad (4 total) OPTIONS Cable maintained 1/2 in NPT CONTACT 1NC/1NO 1NC/1NO 1NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO 4NC 1NC/1NO, low energy 2NC/2NO, low energy 2NC/2NO, low energy 2NC/2NO, low energy 3NC/1NO, low energy 4NC, low energy 94 20 mm INDICATOR None 24 V 120 V None 24 V 120 V None 24 V 120 V None None None 24 V 120 V None None REFERENCE 1CPSA1 1CPSA1A 1CPSA1B 1CPSA2 1CPSA2A 1CPSA2B 1CPSA3 1CPSA3A 1CPSA3B 1CPSA4 1CPSA5 1CPSA6 1CPSA6A 1CPSA6B 1CPSA7 1CPSA8 CONTACT 1NC/1NO 1NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 4NC 1NC/1NO, low energy 2NC/2NO, low energy 2NC/2NO, low energy 3NC/1NO, low energy 4NC, low energy www.honeywell.com/sensing INDICATOR None 24 V None 24 V 120 V None 24 V None None None 24 V None None REFERENCE 1CPSC1 1CPSC1A 1CPSC2 1CPSC2A 1CPSC2B 1CPSC3 1CPSC3A 1CPSC4 1CPSC5 1CPSC6 1CPSC6A 1CPSC7 1CPSC8 SAFETY SWITCHES 2CPS 40,4 (1.60) 67,8 (2.63) 79,8 (3.14) 92,9 (3.66) 325,9 A (12.75) 152,4 (6.00) 52,1 (2.05) 12,7 (0.50) 18,3 (0.72) SLACK RUN OFF TENSIONED 34,9 (1.38) SLACK TENSIONED 21,1 (0.75) 152,4 (6.00) 2X D 2X 2X 8,9 (0.35) 81,3 (3.20) 40,5 (1.60) 6,9 (0.27) 104,8 (4.13) 2X C B 6,4 (0.25) 2X 31,75 (1.25) 57,2 (2.25) 12,7 (0.50) 2X D C 2X 6,9 (0.27) 3X 21,5 (0.85) 139,7 (5.50) OFF Cable maintained both sides 1/2 in NPT CONTACT 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO CONTACT BLOCK MOUNTING 1 1 1 1 1 1 2 2 2 2 2 2 INDICATOR REFERENCE CONTACT None 24 Vdc 120 Vac None 24 Vdc 120 Vac None 24 Vdc 120 Vac None 24 Vdc 120 Vac 2CPSA1A1 2CPSA1A1A 2CPSA1A1B 2CPSA1B1 2CPSA1B1A 2CPSA1B1B 2CPSA2A1 2CPSA2A1A 2CPSA2A1B 2CPSA2B1 2CPSA2B1A 2CPSA2B1B 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO 2NC/2NO 2NC/2NO 4NC Fully extended Optional indicator C Conduit thread (3 total) D Mounting pad (4 total) INDICATOR REFERENCE None 24 Vdc 24 Vdc 2CPSC1A1 2CPSC1A1A 2CPSC1D1A CONTACT BLOCK MOUNTING 1 1 1 1 1 1 2 2 2 INDICATOR REFERENCE None 24 Vdc 120 Vac None 24 Vdc 120 Vac None 24 Vdc 120 Vac 2CPSA1A2 2CPSA1A2A 2CPSA1A2B 2CPSA1B2 2CPSA1B2A 2CPSA1B2B 2CPSA2A2 2CPSA2A2A 2CPSA2A2B INDICATOR REFERENCE None 24 Vdc 2CPSC1A2 2CPSC1A2A 20 mm CONTACT CONTACT BLOCK MOUNTING 1 1 1 A B No actuation right side, cable maintained left side 1/2 in NPT 20 mm CONTACT SLACK RUN TENSIONED SLACK TENSIONED 244,6 A (9.63) 2NC/2NO 2NC/2NO CONTACT BLOCK MOUNTING 1 1 No actuation left side, cable maintained right side 1/2 in NPT CONTACT 2NC/2NO 2NC/2NO 2NC/2NO 3NC/1NO 3NC/1NO 3NC/1NO 2NC/2NO 2NC/2NO 2NC/2NO CONTACT BLOCK MOUNTING 1 1 1 1 1 1 2 2 2 INDICATOR REFERENCE None 24 Vdc 120 Vac None 24 Vdc 120 Vac None 24 Vdc 120 Vac 2CPSA1A3 2CPSA1A3A 2CPSA1A3B 2CPSA1B3 2CPSA1B3A 2CPSA1B3B 2CPSA2A3 2CPSA2A3A 2CPSA2A3B INDICATOR REFERENCE None 24 Vdc 2CPSC1A3 2CPSC1A3A 20 mm CONTACT 2NC/2NO 2NC/2NO CONTACT BLOCK MOUNTING 1 1 www.honeywell.com/sensing 95 SAFETY SWITCHES CPS Series (continued) Hardware packets (order separately) CPS LED 31,75 [1.25] 71,88 ±2,54 [2.83 ±0.10] 11,43 [0.45] C B D A 207,01 ±1,27 [8.15 ±0.05] 227,33 ±12,7 [8.95 ±0.50] CPS Bracket ACCESSORY REFERENCE ACCESSORY REFERENCE Cable - 7,6 m (25 ft) length CLSZC1 (1) Draw-bar Endspring CPSZ1S Cable - 15,2 m (50 ft) length CLSZC2 CPSZK1 Cable - 30,5 m (100 ft) length CLSZC3 Cable - 45,7 m (150 ft) length CLSZC4 (1) J-hook Turnbuckle with Lock Nuts (2) Thimbles (2) Low-profile Duplex Cable Clamps (16) Sets of Cable Supports ((16) 1/4-20 Eye Bolts, (32) 1/4-20 Nuts, (32) Flat Washers, (16) Lock Washers) Cable - 61 m (200 ft) length CLSZC5 Multicluster LED Accessory - 24 Vdc (conduit mount) CPSLED24 Cable - 76,2 m (250 ft) length CLSZC7 Multicluster LED Accessory - 120 Vdc (conduit mount) CPSLED120 (2) Thimbles (2) Low-profile Duplex Cable Clamps CLSZTC Mounting bracket (to be used with 1CPS or 2CPS) CPS-BRACKET J-hook turnbuckle with lock nuts (included with 2CPS) CPSZTB 96 www.honeywell.com/sensing
GKZ72 价格&库存

很抱歉,暂时无法提供与“GKZ72”相匹配的价格&库存,您可以联系我们找货

免费人工找货
GKZ72
    •  国内价格
    • 1+2928.78580

    库存:2

    GKZ72
    •  国内价格
    • 1+2072.27688

    库存:2