H F1 6 5F
SOLAR RELAY
Features
File No:E134517
● 35A swithing capitable.
● Applicable to inverter used for photovoltaic
power generation systems.
● Ideal for UPS.
● 1.8mm contact gap(compliant to European
Photovoltaic Standard VDE0126).
● Product in accordance to IEC 60335 available.
● Low coil hoilding voltage contributes to saving
energy of equipment.
● UL insulation system: class F.
RoHS compliant
V
D E
File No:40037289
File No:R 50463438
File No:CQC18002189685
CQC18002202621
CONTACT DATA
COIL
1A
Contact arrangement
Typ.: 15mV(at 10A)
Max.: 100mV(at 10A)
Voltage drop
AgSnO2
Contact material
Resistive: 35A 250VAC
Contact rating
(Res. load)
Inductive: 35A 277VAC (cosø=0.8) 1s:9s
Max. switching voltage
Max. switching current
35A
Max. switching power
9695VA
1 x 106 OPS
Mechanical endurance
3 x 104 OPS (35A 250VAC,
Insulation resistance
1000M (at 500VDC)
Dielectric Between coil & contacts
strength Between open contacts
4000VAC 1min
2500VAC 1min
Surge voltage
(between coil & contacts)
COIL DATA
Nominal
Voltage
VDC 1)
at 23
Pick-up Drop-out
Voltage Voltage
VDC
VDC
max1)
min1)
Max.
Voltage
VDC * 2)
Coil
Resistance
5
3.75
0.35
5.5
12
9
0.84
13.2
64 x (1 10%)
24
18
1.68
26.4
256 x (1 10%)
48
36
3.36
52.8
1024 x (1 10%)
11.1 x (1 10%)
Notes: 1)The data shown above are initial values.
2)*Maximun voltage refers to the maximun voltage which relay
coil could endure in a short period of time.
6kV (1.2/50µs)
Operate time (at rated. volt.)
15ms max.
Release time (at rated. volt.)
10ms max.
70K max.(Contact load
current 43A, 50% of rated
o
voltage excitation, at 85 C)
Functional
Shock
resistance Destructive
UL/CUL
VDE
980m/s2
TUV
-40 C to 85 C
o
(Apply holding voltage to coil)
5% to 85% RH
Humidity
SAFETY APPROVAL RATINGS
98m/s2
10Hz to 55Hz 1.5mm DA
o
Ambient temperature
Notes: 1)The coil holding voltage is the voltage applied to coil 100ms
after the rated voltage.
2)To avoid overheating and burning, the coil can not be consistently
applied to with voltage larger than maximum holding voltage.
o
CHARACTERISTICS
Vibration resistance
Holding voltage
Resistive load, at 85 C, 1s on 9s off)
Notes: 1)The relay connections and wiring have to be designed with
an adequate cross setions to ensure the current flow and
heat dissipation.
Temperature rise
(at rated. volt.)
40% to 110%UN(at 23 )
50% to 70%UN(at 85 )
277VAC
1)
Electrical endurance
Approx.2.25W
Coil power
35A 277VAC/250VAC general use
3 x 104OPS 85 C
o
35A 250VAC
3 x 104OPS 85 C
43A 277VAC/250VAC 85 C
Making 10A Carrying 43A Breaking10A 85 C
40A 277VAC/250VAC 60 C
o
o
CQC
o
o
Notes: 1) All values unspecified are at room temperature.
2) Only typical loads are listed above. Other load specifications
can be available upon request.
PCB
Termination
Approx.36g
Unit weight
Construction
Flux proofed
Notes: The data shown above are initial values.
HONGFA RELAY
ISO9001、ISO/TS16949、ISO14001、OHSAS18001、IECQ QC 080000 CERTIFIED
304
2020 Rev. 1.01
ORDERING INFORMATION
H F 1 6 5F /
12
-H
T
(XXX)
Type
Coil voltage
5, 12, 24, 48VDC
Contact arrangement
H:1 Form A
Contact matcrial
T: AgSnO2
Special code3)
XXX: Customer special requirement
Nil: Standard
Notes: 1) Water cleaning or surface process is not suggested after the flux-proofed relays are assembled on PCB.
2) Flux-proofed relays can not be used in the environment with pollutants like H2S, SO2, NO2, dust, etc.
3) The customer special requirement express as special code after evaluating by Hongfa. e.g.(335) stands for product in accordance to
IEC 60335-1 (GWT).
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions
5.5 ±0.4
19.4 ±0.4
3.35 ±0.3
27.4 ±0.4
0.95 ±0.2
3.8 ±0.3
0.7X0.7 ±0.2
PCB Layout (Bottom view)
3.92
20.1 ±0.4
22.4 ±0.4
Wiring Diagram
+ 0.08
-0.03
1.78
≤R0.5
≤R0.5
2XØ1.1 + 00. 1
3.81
13.97
18.75
Notes: 1) In case of no tolerance shown in outline dimension: outline dimension ≤1mm, tolerance should be ±0.2mm; outline dimension >1mm
and ≤5mm, tolerance should be ±0.3mm; outline dimension >5mm, tolerance should be ±0.4mm.
2) The tolerance without indicating for PCB layout is always ±0.1mm.
305
CHARACTERISTIC CURVES
MAXIMUM SWITCHING POWER
ENDURANCE CURVE
100
100
50
AC Resistive load
250VAC
Resistive load
10
10
5
1
1
0.5
10
100
1000
0
5
15
Contact Voltage(V)
25
35
Contact Current(A)
Test conditions:
Resistive load, 250VAC,
o
Flux proofed, at 85 C, 1s on 9s off
Disclaimer
The specification is for reference only. See to "Terminology and Guidelines" for more information. Specifications subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. If there is any query, please contact Hongfa for the technical service. However, it is the user’s
responsibility to determine which product should be used only.
© Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
306
很抱歉,暂时无法提供与“HF165F/12-HT(257)”相匹配的价格&库存,您可以联系我们找货
免费人工找货