0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GEN80-19

GEN80-19

  • 厂商:

    LAMBDA

  • 封装:

  • 描述:

    GEN80-19 - Programmable DC Power Supplies 750W/1500W - DENSEI-LAMBDA

  • 数据手册
  • 价格&库存
GEN80-19 数据手册
The GenesysTM family of programmable power supplies sets a new standard for flexible, reliable, AC/DC power systems in OEM, Industrial and Laboratory applications. Features include: • Highest Power Density available 1500W in 1U • Wide Range Input 85 - 265Vac Continuous, single phase, 47/63Hz • Active Power Factor Correction 0.99 • Output up to 600V, Current up to 200A • Built in RS232/RS485 Interface • Software Calibration • Last Setting Memory • High Resolution 16 bits ADCs & DACs • Reliable Encoders for Voltage and Current Adjustment • Constant Voltage/Constant Current auto crossover • Parallel Operation with Active Current Sharing • Independent Remote ON/OFF and Remote Enable/Disable • External Analog Programming and Monitoring • Reliable Modular and SMT Design • 19" Rack Mounted ATE and OEM applications • Five Year Warranty • Optional Isolated Analog Programming and Monitoring • Optional GPIB (SCPI) Interface • LabView® drivers ( LabView® is registered trademark of National Instruments Corporation ) Worldwide Safety Agency Approvals CE Mark for LVD and EMC Regulation Applications Genesys™ power supplies have been designed to meet the demands of a wide variety of applications. Test and Measurement Last setting memory simplifies test design and requires no battery backup. Built in RS232/RS485 gives maximum system flexibility along with 0-5V and 0-10V, selectable analog programming Wide range of available inputs allows testing of many different devices. Semiconductor Burn-in Safe Start may be enabled to restart at zero output to protect load. Wide range input (85-265VAC) with Active Power Factor correction rides through input transients easily. Component Test High power density, zero stacking and single wire parallel operation give maximum system flexibility Laser Diode OVP is directly set on Voltage Meter, assuring accurate protection settings. Current Limit Fold Back assures load is protected from current surges. Heater Supplies Smooth, reliable encoders enhance front panel control. Remote analog programming is user selectable 0-5V or 0-10V. RF Amplifiers and Magnets Robust design assures stable operation under a wide variety of loads. Excellent linearity in voltage and current mode. 1|Genesys™ 750W/1500W-1U Front Panel Description 1. AC On/Off 2. Air Intake allows zero stacking for maximum system flexibility and power density 3. Reliable encoder controls Output Voltage and sets Address. 4. Volt Meter shows Output Voltage and directly displays OVP, UVL and Address settings. 5. Amp Meter also displays baud rate. 6. Reliable encoder controls Output Current and sets baud rate. 7. Function/Status LED's • Alarm • Fine Control • Preview Settings • Foldback Mode • Remote Mode • Output On 8. Pushbuttons allow flexible user configuration Coarse and Fine Voltage and Current Adjustment of Output Preview Settings and Set Voltage while in Current Mode or with Output OFF Set OVP and UVL Limits Set Current Foldback Local/Remote Mode and select Address and Baud Rate Output ON/OFF and Auto Start/Safe Start Mode Rear Panel Description 1. 2. 3. 4. 5. 6. 7. 8. Remote/Local Output Voltage Sense Connections DIP Switches select 0-5V or 0-10V Programming and other functions. DB25 (Female) connector allows (Non-isolated) Analog Program and Monitor as well as other functions. RS485 Out to other Genesys Power Supplies RS232/RS485 IN Remote Serial Programming Output Terminals are rugged bus bars for 6-60V Output, higher output voltage models have terminal block connector. Exit air assures reliable operation when zero stacked Wide-Range Input 85-265VAC continuous, 47/63Hz with Active Power Factor Correction (0.99) AC Input Connector 750W: IEC320, 1500W: Screw terminal Model Shown 9. Position for Optional Isolated Analog Programming or GPIB Digital Interface model shown |2 Genesys ™ 750W/1500W Specifications 1.0 MODEL 1.Rated output voltage(*1) 2.Rated Output Current(*2) 3.Rated Output Power 4.Efficiency at 100/200Vac (*3) 1.0 MODEL 1.Rated output voltage (*1) 2.Rated Output Current (*2) 3.Rated Output Power 1.1 CONSTANT VOLTAGE MODE 1.Max.line regulation ( 0.01% of Vo+ 2mV )(*4) 2.Max load regulation ( 0.01% of Vo+2mV )(*5) 3.Ripple and noise p-p 20MHz 4.Ripple r.m.s 5Hz~1MHz 5.Remote sense compensation/line 6.Temp. coefficient 7.Up-prog. response time, 0~Vomax 8.Down-prog response time full-load 9.Down-prog response time no-load 10.Transient response time (*8) 1.2 CONSTANT CURRENT MODE 1.Max.line regulation (0.01% of Io+ 2mA)(*4) 2.Max.load regulation (0.01% of Io+5mA)(*6) 3.Ripple r.m.s 5Hz~1MHz . (*7) 1.Max.line regulation (0.01% of Io+ 2mA)(*4) 2.Max.load regulation (0.01% of Io+5mA)(*6) 3.Ripple r.m.s 5Hz~1MHz .(*7) 4.Temp. coefficient 1.3 PROTECTIVE FUNCTIONS 1. OCP 2. OCP Foldback 3. OVP type 4. OVP trip point 5. Over Temp. Protection 1.4 ANALOG PROGRAMMING AND MONITORING 1.Vout Voltage Programming 2.Iout Voltage Programming 3.Vout Resistor Programming 4.Iout Resistor Programming 5.On/Off control (rear panel) 6.Output Current monitor 7.Output Voltage monitor 8.Power Supply OK signal 9. CV/CC indicator 10. Enable/Disable 1.5 FRONT PANEL 1.Control functions GEN V A W % GEN V A W 6-200 6 200 1200 77/80 6-100 6 100 600 8-180 12.5-120 20-76 8 12.5 20 180 1440 78/81 8-90 8 90 720 120 1500 81/84 76 1520 83/86 30-50 30 50 1500 83/86 30-25 30 25 750 40-38 40 38 1520 84/88 60-25 60 25 1500 84/88 80-19 100-15 80 100 19 1520 84/88 15 1500 84/88 150-10 150 10 1500 84/88 150-5 150 5 750 300-5 300 5 1500 83/87 600-2.6 600 2.6 1560 83/87 750W X X X X X X X X X X X X X X X X X X 1500W X X X X X 12.5-60 20-38 12.5 20 60 38 750 760 40-19 60-12.5 80-9.5 100-7.5 40 60 80 100 19 12.5 9.5 7.5 760 750 760 750 300-2.5 600-1.3 300 600 2.5 1.3 750 780 62 62 300 60 5 mV 2.6 2.8 3.3 4 5 6 8 10 12 17 32 mV 2.6 2.8 3.3 4 5 6 8 10 12 17 32 mV 60 60 60 60 60 60 60 80 100 80 125 mV 8 8 8 8 8 8 8 8 8 10 25 V 1 1 1 1 1.5 2 3 4 5 5 5 PPM/°C 100PPM/°C from rated output voltage,following 30 minutes warm up mS 80mS , N.L/F.L , resistive load 150mS , N.L/F.L , resistive load mS 10 50 80 150 mS 500 600 700 800 900 1000 1100 1200 1500 2000 2500 Less than 1mSec for models up to and including 100V. 2msec for models above 100V mA 12 5.8 4.5 11 8 3.9 3.25 2.95 15 7.5 mA 14 11 8.8 6.9 6.25 5.95 mA 200 120 76 63 38 180 48 29 2 2 mA 2 2 2 2 2 2 mA 5 5 5 5 5 5 5 5 mA 400 152 125 360 240 95 75 57 PPM/°C 100PPM/°C from rated output voltage,following 30 minutes warm up 2.75 5.75 23 2 5 45 2.5 5.5 18 2 5 35 2.25 5.25 13 2 5 25 4000 X X X X X X X X X X 2.13 5.13 8 2 5 12 X X X X X X X X X X X X X X X X X X X X X X X X X 750W X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X 1500W X X X 0~105% Constant Current Output shut down when power supply change from CV to CC. User selectable. Inverter shut-down, manual reset by AC input recycle or by OUT button 0.5~7.5V 0.5~10V 1~15V 1~24V 2~36V 2~44V 5~66V 5~88V 5~110V 5~165V 5~330V 5~660V User selectable , latched or non latched 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-0.5% of rated Vout. 0~100%, 0~5V or 0~10V, user select. Accuracy and linearity:+/-1% of rated Iout. 0~100%, 0~5/10Kohm full scale,user select.,Accuracy and linearity:+/-1% of rated Vout. 0~100%, 0~5/10Kohm full scale,user select. Accuracy and linearity:+/-1.5% of rated Iout. By electrical. Voltage: 0~0.6V/2~15V,or dry contact ,user selectable logic 0~5V or 0~10V , accuracy:1% , user selectable 0~5V or 0~10V ,accuracy:1% ,user selectable 5V-OK, 0V-Fail 500ohm impedance CV: TTL high (4~5V) source: 10mA, CC: TTL low (0~0.4V):10mA Dry contact. Open:off , Short: on. Max. voltage at Enable/Disable in: 6V Vout/ Iout manual adjust by separate encoders (coarse and fine adjustment selectable) OVP/UVL manual adjust by Volt. Adjust encoder AC on/off, Output on/off, Re-start modes (auto, safe), Foldback control (CV to CC), Go to local control Address selection by Voltage (or current) adjust encoder. No of addresses:31 RS232/485 and IEEE488.2 selection by IEEE enable switch and DIP switch Baud rate selection: 1200,2400,4800,9600 and 19,200 bps Voltage 4 digits , accuracy: 0.5%+/-1 count Current 4 digits, accuracy: 0.5%+/-1 count Voltage, Current, Alarm, Fine, Preview, Foldback, Local, Output On 2.Display 3.Indications 1.6 Interface RS232&RS485 or Optional GPIB Interface V Model Remote Voltage Programming (16 bit) Resolution (0.012% of Vomax) mV Accuracy (0.05%Vomax+0.05% of Vo Actual Output) mV Remote Current Programming (16 bit) Resolution (0.012% of Iomax) Accuracy (0.05% of Iomax+0.05% of Io Actual Output) Resolution (0.012% of Iomax) Accuracy (0.05% of Iomax+0.05% of Io Actual Output) 6 0.72 6.0 8 0.96 8.0 12.5 1.50 12.5 20 2.40 20 30 3.60 30 40 4.80 40 60 7.2 60 80 9.6 80 100 12 100 150 18 150 300 36 300 600 72 600 mA mA mA mA 12 10 24 20 10.8 9 21.6 18 7.2 6 14.4 12 4.56 3.8 9.12 7.6 3.0 2.5 6 5 2.28 1.9 4.56 3.8 1.50 1.25 3.0 2.5 1.14 0.95 2.28 1.9 0.90 0.75 1.80 1.50 0.60 0.5 1.20 1 0.30 0.25 0.60 0.5 0.16 0.13 0.32 0.26 X X X X Readback Voltage Resolution (0.012% of Vomax) mV Accuracy (0.1%Vomax+0.1% of Vo Actual Output) mV Readback Current Resolution (0.012% of Iomax ) Accuracy (0.1% of Iomax+0.3% of Io Actual Output) Resolution (0.012% of Iomax ) Accuracy (0.1% of Iomax+0.3% of Io Actual Output) OVP Programming Resolution (0.1% of Vomax) Accuracy (1% of Vomax) 0.72 12 0.96 16 1.50 25 2.40 40 3.60 60 4.80 80 7.2 120 9.6 160 12 200 18 300 36 600 72 1200 X X X X mA mA mA mA 12 400 24 800 10.8 360 21.6 720 7.2 240 14.4 480 4.56 152 9.12 304 3.0 100 6 200 2.28 76 4.56 152 1.50 50 3.0 100 1.14 38 2.28 76 0.9 30 1.80 60 0.60 20 1.20 40 0.30 10 0.60 20 0.16 5.2 0.32 10.4 X X X X mV mV 6 60 8 80 12 125 20 200 29 300 39 400 59 600 78 800 98 1000 146 1500 293 3000 586 6000 X X X X *1: Minimum voltage is guaranteed to maximum 0.2% of Vomax. *3: At maximum output power. *5: From No-load to Full-load, constant input voltage. *2: Minimum current is guaranteed to maximum 0.4% of Iomax. *4: 85~132Vac or 170~265Vac, constant load. *6: For load voltage change, equal to the unit voltage rating, constant input voltage. *7: For 6V models the ripple is measured at 2~6V output voltage and full output current. For other models, the ripple is measured at 10~100% output voltage and full output current. *8: Time for the output voltage to recover within 0.5% of its rated for a load change 10~90% of rated output , Output set-point:10~100%. Accuracy -Values have been calculated at Vomax & Io max 3|Genesys™ 750W/1500W-1U General Specifications Genesys™ 750W/1500W 2.1 INPUT CHARACTERISTICS 1. Input voltage/freq. (*1) 2. Power Factor 3. EN61000-3-2,3 compliance 4. Input current 100/200Vac 5. Inrush current 100/200Vac 6. Hold-up time 2.2 POWER SUPPLY CONFIGURATION 1. Parallel Operation 2. Series Operation 2.3 ENVIRONMENTAL CONDITIONS 1. Operating temp 2. Storage temp 3. Operating humidity 4. Storage humidity 5. Vibration 6. Shock 7. Altitude 2.4 EMC 1.Applicable standards: 2.ESD 3.Fast transients 4.Surge immunity 5.Conducted immunity 6.Radiated immunity 7.Conducted emission 8.Radiated emission 9.Voltage dips 10. Conducted emission 11. Radiated emission 2.5 SAFETY 1.Applicable standards: 85~265Vac continuous, 47~63Hz, single phase 0.99 @100/200Vac, rated output power. Complies with EN61000-3-2 class A and EN61000-3-3 at 20~100% output power. 750W :10.5A / 5A, 1500W :21A / 11A 750W :Less than 25A, 1500W :Less than 50A More than 20mS , 100Vac , at 100% load. Up to 4 units in master/slave mode with single wire current balance connection Up to 2 units. with external diodes. 600V Max to Chassis ground 0~50 °C, 100% load. -20~70°C 30~90% RH (no condensation). 10~95% RH (no condensation). MIL-810E, method 514.4 , test cond. I-3.3.1 . The EUT is fixed to the vibrating surface. Less than 20G , half sine , 11mSec. Unit is unpacked. Operating: 10000ft (3000m) , Non operating: 40000ft (12000m). EN55024 IEC1000-4-2. Air-disch.-8KV, contact disch.-4KV IEC1000-4-4. 2KV IEC1000-4-5. 1KV line to line, 2KV line to ground IEC1000-4-6, 3V IEC1000-4-3, 3V/m EN55022B,FCC part 15J-B,VCCI-2 EN55022A,FCC part 15-A,VCCI-1 EN61000-4-11 EN55022B, FCC part 15-B, VCCI-2. EN55022A, FCC part 15-A, VCCI-1. 2.Withstand voltage 3.Insulation resistance 2.6 MECHANICAL CONSTRUCTION 1. Cooling 2. Dimensions (WxHxD) 3. Weight 4. AC Input connector 5.Output connectors 2.7 RELIABILITY SPECS 1. Warranty CE Mark, UL60950,EN60950 listed. Vout
GEN80-19 价格&库存

很抱歉,暂时无法提供与“GEN80-19”相匹配的价格&库存,您可以联系我们找货

免费人工找货