High sensitivity, 100 mW
Nominal operating power,
2 Form C and 2 A Compact
flat body type relays
RoHS compliant
GQ RELAYS (AGQ)
FEATURES
TYPICAL APPLICATIONS
1. High capacity: 2 A
2. Flat compact size
10.6 (L) × 7.2 (W) × 5.2 (H) mm
.417 (L) × .283 (W) × .205 (H) inch
3. High sensitivity single side stable
type (Nominal operating power:
100mW) is available
4. Outstanding surge resistance.
1,500 V 10×160 μs (FCC part 68)
(open contacts)
2,500 V 2×10 μs (Telcordia) (contact
and coil)
5. The use of twin crossbar contacts
ensures high contact reliability
AgPd contact is used because of its
good sulfide resistance. Adopting lowgas molding material. Coil assembly
molding technology which avoids
generating volatile gas from coil.
1. Telephone switchboard
2. Telecommunications equipment
3. Security
4. Measurement equipment
5. Consumer electronic and audio
visual equipment
ORDERING INFORMATION
AGQ 2
0
Contact arrangement
2: 2 Form C
Operating function
0: Single side stable
1: 1 coil latching
6: High sensitivity single side
stable type
Type of operation
0: Standard type (B.B.M.)
Terminal shape
Nil: Standard PC board terminal
A: Surface-mount terminal A type
S: Surface-mount terminal S type
Nominal coil voltage (DC)
1H: 1.5V 03: 3V 4H: 4.5V 06: 6V 09: 9V
12: 12V 24: 24V
Packing style
Nil: Tube packing
X: Tape and reel packing (picked from 1/2/3/4 pin side)
Z: Tape and reel packing (picked from 5/6/7/8 pin side)
–1–
ASCTB7E 201407-T
GQ (AGQ)
TYPES
1. Standard PC board terminal
Nominal coil voltage
1.5 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
Single side stable
Part No.
AGQ2001H
AGQ20003
AGQ2004H
AGQ20006
AGQ20009
AGQ20012
AGQ20024
1 coil latching
Part No.
AGQ2101H
AGQ21003
AGQ2104H
AGQ21006
AGQ21009
AGQ21012
AGQ21024
High sensitivity single side stable
Part No.
AGQ2601H
AGQ26003
AGQ2604H
AGQ26006
AGQ26009
AGQ26012
AGQ26024
Single side stable
Part No.
AGQ2001H
AGQ20003
AGQ2004H
AGQ20006
AGQ20009
AGQ20012
AGQ20024
1 coil latching
Part No.
AGQ2101H
AGQ21003
AGQ2104H
AGQ21006
AGQ21009
AGQ21012
AGQ21024
High sensitivity single side stable
Part No.
AGQ2601H
AGQ26003
AGQ2604H
AGQ26006
AGQ26009
AGQ26012
AGQ26024
Single side stable
Part No.
AGQ2001HZ
AGQ20003Z
AGQ2004HZ
AGQ20006Z
AGQ20009Z
AGQ20012Z
1 coil latching
Part No.
AGQ2101HZ
AGQ21003Z
AGQ2104HZ
AGQ21006Z
AGQ21009Z
AGQ21012Z
High sensitivity single side stable
Part No.
AGQ2601HZ
AGQ26003Z
AGQ2604HZ
AGQ26006Z
AGQ26009Z
AGQ26012Z
AGQ20024Z
AGQ21024Z
AGQ26024Z
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
2. Surface-mount terminal
1) Tube packing
Nominal coil voltage
1.5 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
: For each surface-mounted terminal identification, input the following letter. A type: A, S type: S
Standard packing: Tube: 50 pcs.; Case: 1,000 pcs.
2) Tape and reel packing
Nominal coil voltage
1.5 V DC
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
: For each surface-mounted terminal identification, input the following letter. A type: A, S type: S
Standard packing: Tape and reel: 900 pcs.; Case: 1,800 pcs.
Notes: 1. Tape and reel packing symbol “-Z” is not marked on the relay. “X” type tape and reel packing (picked from 1/2/3/4-pin side) is also available.
2. Please inquire if you require a relay, between 1.5 and 24 V DC, with a voltage not listed.
RATING
1. Coil data
1) Single side stable type
Nominal operating
current
[±10%] (at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
1.5 V DC
93.8 mA
16
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
46.7 mA
31 mA
23.3 mA
15.5 mA
11.7 mA
64.2 Ω
145 Ω
257 Ω
579 Ω
1,028 Ω
Nominal coil
voltage
24
Pick-up voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Drop-out voltage
(at 20°C 68°F)
10%V or more of
nominal voltage*
(Initial)
V DC
9.6 mA
2,504
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
140 mW
150%V of
nominal voltage
230 mW
120%V of
nominal voltage
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
100 mW
150%V of
nominal voltage
Ω
Ω
2) 1 coil latching type
1.5 V DC
Nominal operating
current
[±10%] (at 20°C 68°F)
66.7 mA
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
24 V DC
33.3 mA
22.2 mA
16.7 mA
11.1 mA
8.3 mA
5.0 mA
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Reset voltage
(at 20°C 68°F)
75%V or less of
nominal voltage*
(Initial)
Coil resistance
[±10%] (at 20°C 68°F)
22.5 Ω
90 Ω
202.5 Ω
360 Ω
810 Ω
1,440 Ω
4,800 Ω
120 mW
*Pulse drive (JIS C 5442-1996)
–2–
ASCTB7E 201407-T
GQ (AGQ)
3) High sensitivity single side stable type
Nominal coil
voltage
Set voltage
(at 20°C 68°F)
Nominal operating
current
[±10%] (at 20°C 68°F)
Reset voltage
(at 20°C 68°F)
Coil resistance
[±10%] (at 20°C 68°F)
1.5 V DC
66.7 mA
22.5 Ω
3 V DC
4.5 V DC
6 V DC
9 V DC
12 V DC
33.3 mA
22.2 mA
16.7 mA
11.1 mA
8.3 mA
90 Ω
202.5 Ω
360 Ω
810 Ω
1,440 Ω
24
80%V or less of
nominal voltage*
(Initial)
10%V or more of
nominal voltage*
(Initial)
V DC
5.0 mA
4,800
Nominal operating
power
Max. applied voltage
(at 20°C 68°F)
100 mW
150%V of
nominal voltage
120 mW
120%V of
nominal voltage
Ω
*Pulse drive (JIS C 5442-1996)
2. Specifications
Characteristics
Contact
Rating
Item
Arrangement
Initial contact resistance, max.
Contact material
Nominal switching capacity
Max. switching power
Max. switching voltage
Max. switching current
Min. switching capacity (Reference value)*1
Single side stable
Nominal operating
High sensitivity single side
power
stable type
1 coil latching
Specifications
2 Form C
Max. 100 mΩ (By voltage drop 6 V DC 1A)
Stationary contact: AgPd+Au clad Movable contact: AgPd
2 A 30 V DC, 1 A 30 V DC, 0.3 A 125 V AC (resistive load)
60 W (DC), 30 W (DC), 37.5 V A (AC) (resistive load)
110 V DC, 125 V AC
2A
10μA 10 mV DC
140mW (1.5 to 12 V DC), 230mW (24 V DC)
100mW (1.5 to 12 V DC), 120mW (24 V DC)
Min. 1,000MΩ (at 500V DC)
Measurement at same location as “Initial breakdown voltage” section.
750 Vrms for 1min. (Detection current: 10mA)
1,500 Vrms for 1min. (Detection current: 10mA)
1,000 Vrms for 1min. (Detection current: 10mA)
1,500 V (10×160μs) (FCC Part 68)
2,500 V (2×10μs) (Telcordia)
Max. 50°C
(By resistive method, nominal coil voltage applied to the coil; contact carrying current: 1A.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
Max. 4 ms [Max. 4 ms] (Nominal coil voltage applied to the coil, excluding contact bounce time.)
(without diode)
Min. 750 m/s2 (Half-wave pulse of sine wave: 6 ms; detection time: 10μs.)
Min. 1,000 m/s2 (Half-wave pulse of sine wave: 6 ms.)
10 to 55 Hz at double amplitude of 3.3 mm (Detection time: 10μs.)
10 to 55 Hz at double amplitude of 5 mm
Min. 5 × 107 (at 180 cpm)
Min. 5 × 104 (2 A 30 V DC resistive), Min. 105 (1 A 30 V DC resistive),
Min. 105 (0.3 A 125 V AC resistive) (at 20 cpm)
Ambient temperature:
(Single side stable, 1 coil latching type) –40°C to +85°C –40°F to +185°F
(High sensitivity single side stable type) –40°C to +70°C –40°F to +158°F
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
20 cpm
Approx. 1 g .035 oz
Insulation resistance (Initial)
Breakdown voltage
(Initial)
Electrical
characteristics
Surge breakdown
voltage (Initial)
Between open contacts
Between contact and coil
Between contact sets
Between open contacts
Between contacts and coil
Temperature rise (at 20°C 68°F)
Operate time [Set time] (at 20°C 68°F)
Release time [Reset time] (at 20°C 68°F)
Mechanical
characteristics
Expected life
Conditions
Functional
Destructive
Functional
Vibration resistance
Destructive
Mechanical
Shock resistance
Electrical
Conditions for operation, transport and storage*2
Max. operating speed (at rated load)
Unit weight
Notes: *1 This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2 Refer to “AMBIENT ENVIRONMENT” in GENERAL APPLICATION GUIDELINES.
REFERENCE DATA
1. Max. switching capacity
2. Life curve
3. Mechanical life
* Max. switching capacity is 2A 30V DC.
Tested sample: AGQ200A4H, 6 pcs.
Operating speed: 180 cpm
1.0
0.3
4
50
40
30
DC 30V resistive load
20
100
Contact voltage, V
0
Pick-up voltage
Max.
3
Min.
2
AC 125V
resistive load
10
30
Voltage, V
DC resistive load
AC resistive load
No. of operations, × 104
Switching current, A
100
0.2
0.4
0.6
0.8
1
1.0
Switching current, A
–3–
1.2
0
0
Drop-out voltage
10
30
Max.
Min.
50
No. of operations, ×104
ASCTB7E 201407-T
GQ (AGQ)
4. Electrical life (1A 30V DC resistive load)
5. Coil temperature rise
Tested sample: AGQ200A4H, 6 pcs.
Operating speed: 20 cpm
Tested sample: AGQ200A4H, AGQ200A24, 6 pcs.
Point measured: Inside the coil
Ambient temperature: Room temperature
Change of contact resistance
100
90
90
80
Pick-up voltage
70
Max.
Min.
60
50
40
Drop-out voltage
30
80
70
60
50
X
X
40
30
Max.
Min.
20
70
N.C. contact
N.O. contact
Temperature rise, °C
100
Contact resistance, mΩ
Ratio against the rated voltage, %V
Change of pick-up and drop-out voltage
1A
0A
30
10
0
0
10
No. of operations, ×10
40
20
10
5
1A
0A
50
20
10
0
0
4.5V DC type
24V DC type
60
5
0
10
No. of operations, ×10
4
100
110
4
120
130
140
150
Coil applied voltage, %
6-(2). Operate and release time (with diode)
7. Ambient temperature characteristics
Tested sample: AGQ2004H, 10 pcs.
Tested sample: AGQ2004H, 10 pcs.
Tested sample: AGQ200A4H, 6 pcs.
3
Operate time
Release time
Operate and release time, ms
Operate and release time, ms
3
Max.
2
1
Min.
Max.
Min.
Operate time
Release time
Max.
2
Drop-out
voltage
-40 -20
0
Min.
Max.
Min.
Rate of change, %V
6-(1). Operate and release time (without diode)
Pick-up
voltage
1
50
40
30
20
x
x
10
20 40
60
80 100
-10
Ambient temperature, °C
-20
-30
-40
0
70
80
90
100
110
120
0
130
70
80
90
100
110
120
-50
130
Coil applied voltage, %V
Coil applied voltage, %V
9-(2). Influence of adjacent mounting
Tested sample: AGQ20012, 6 pcs.
Tested sample: AGQ20012, 6 pcs.
Y
1,000m/s2
Deenergized condition
Energized condition
X
1,000m/s2
Z
1,000m/s2
1,000m/s2
Z'
1,000m/s2
X'
1,000m/s2
Y'
10
5
ON
Pick-up voltage
0
-5
ON
-10
10
OFF
OFF
5
Drop-out voltage
0
OFF
-5
-10
0
DIMENSIONS (mm inch)
ON
Rate of change, %V
X'
Rate of change, %V
Z X
Z'
Y
Y'
Rate of change, %V
9-(1). Influence of adjacent mounting
Tested sample: AGQ200A4H, 6 pcs.
Rate of change, %V
8. Malfunctional shock
CAD Data
5
ON
Pick-up voltage
0
ON
-5
ON
-10
10
OFF
5
Drop-out voltage
0
OFF
-5
-10
0
2
4
6
8 10 12
.079 .157 .236 .315 .394 .472
Inter-relay distance , mm inch
The CAD data of the products with a
10
OFF
2
4
6
8 10 12
.079 .157 .236 .315 .394 .472
Inter-relay distance , mm inch
mark can be downloaded from: http://industrial.panasonic.com/ac/e/
1. PC board terminal
External dimensions
CAD Data
10.60±0.3
.417±.012
5.20±0.2
.205±.008
PC board pattern
2.20
.087
7.20±0.3
.283±.012
3.20
.126
0.40±0.1
.016±.004
3.20±0.15
.126±.006
2.20±0.15
.087±.006 3.50±0.3
2.20±0.15 .138±.012
.087±.006
0.20±0.1
.008±.004
5.08±0.15
.200±.006
2.20
.087
5.08
.200
1
2 3 4
8
7 6 5
1 coil latching
1
2 3 4
8
7 6 5
0.85 dia.
.033 dia.
Tolerance: ±0.1 ±.004
–4–
Schematic (Bottom view)
Single side stable
High sensitivity
single side stable
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
ASCTB7E 201407-T
GQ (AGQ)
2. Surface-mount terminal
CAD Data
Suggested mounting pad (Tolerance: ±0.1 ±.004)
Single side stable/1 coil latching/High sensitivity single side stable
External dimensions
Single side stable/1 coil latching/High sensitivity single side stable
Type
Max. 5.40
.213
7.20±0.3
.283±.012
10.60±0.3
.417±.012
A type
2.20±0.15
.087±.006
2.20±0.15
.087±.006
0.40±0.1
.016±.004
3.20±0.15
.126±.006
Max. 5.40
.213
0.20±0.1
.008±.004
2.20
.087
2.20
.087
3.20
.126
2.66 6.74
.105 .265
5.08±0.15
.200±.006
8.40±0.3
.331±.012
0.80
.031
7.20±0.3
.283±.012
10.60±0.3
.417±.012
2.20
.087
2.20
.087
3.20
.126
S type
0.20±0.1
.008±.004
5.08±0.15
.200±.006
2.20±0.15
.087±.006
0.40±0.1
.016±.004
3.20±0.15
.126±.006
2.20±0.15
.087±.006
2.06
.081
6.14
.242
0.80
.031
7.20±0.3
.283±.012
Schematic (Top view)
Single side stable
High sensitivity single side stable
8
7 6 5
1
2 3 4
1 coil latcing
8
7 6 5
1
2 3 4
Direction indication
Direction indication
(Deenergized condition)
(Reset condition)
NOTES
1. Packing style
1) The relay is packed in a tube with the
relay orientation mark on the left side, as
shown in the figure below.
(S type)
(1)-2 Tape dimensions
Relay polarity bar
(Z type)
1.50 +0.1
0 dia.
.059 +.003
.0 dia.
4.0 2.00 dia.
.157 .079 dia.
1.75
.069
2.0
.079
Orientation (indicates PIN No.1) stripe
11.5
.453
Max. 6.55
.256
0.40
.016
24.0±0.3
.945±.012
11.1
.437
7.8
.307
12.0
.472
GQ relays
Tape coming out direction
Stopper (green)
Stopper (red)
General tolerance ±0.1 mm .004 inch
(2) Dimensions of plastic peel
Orientation (indicates PIN No.1) stripe
mm inch
2. Automatic insertion
To maintain the internal function of the
relay, the chucking pressure should not
exceed the values below.
Chucking pressure in the direction A :
9.8 N {1 kgf} or less
Chucking pressure in the direction B :
9.8 N {1 kgf} or less
Chucking pressure in the direction C :
9.8 N {1 kgf} or less
A
C
B
21 dia.
.827 dia.
Stopper (green)
Stopper (red)
2.0
.079
2) Tape and reel packing
(A type)
(1)-1 Tape dimensions
80±1 dia.
3.150±.039 dia.
mm inch
Relay polarity bar
(Z type)
1.50 +0.1
0 dia.
.059 +.003
.0 dia.
2.0
.079
dia.
4.00 2.00
.157 .079 dia.
1.75
.069
330±2 dia.
12.992±.079 dia.
Max. 6.55
.256
0.40
.016
13 dia.
.512 dia.
11.5
.453 24.0±0.3
.945±.012
11.1
.437
GQ relays
12.0
.472
9.0
.354
Please chuck the
portion.
Avoid chucking the center of the relay.
In addition, excessive chucking pressure
to the pinpoint of the relay should be also
avoided.
For general cautions for use,
please refer to the “Cautions for
use of Signal Relays” or “General
Application Guidelines”.
Tape coming out direction
General tolerance ±0.1 mm .004 inch
–5–
ASCTB7E 201407-T