703
FIBER
SENSORS
Digital Pressure Sensor
For Gas
DP-0 SERIES
Related Information
■■General terms and conditions.............. F-3
■■Glossary of terms........................ P.1563~
■■Selection guide.............................. P.699~
■■General precautions...................... P.1566
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
panasonic.net/id/pidsx/global
Simple and easy operation
Redesigned for improvement of pressure sensor usability from ground up
Simple & easy operation
Two levels of configuration for easy operation of essential functions
The “RUN mode” is for setting the threshold value, the zero point adjustment and key lock/release setting, and the
“detailed configuration” allows the basic settings of sensor operation. The two-level configuration enables an easy
and immediate use of the product.
UV CURING
SYSTEMS
Detailed configuration
Pressure unit
setting mode
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
NO/NC
setting mode
Response time
setting mode
• Threshold value setting
• Zero point adjustment
• Key lock setting / release
DP-100
Operation setting mode*
NO/NC setting mode
Select from EASY mode,
hysteresis mode or window
comparator mode.
Set the comparative output
operation to NO or NC.
Response time setting mode
Display color setting mode
Select the response time from
2.5 ms, 25 ms or 250 ms.
Select the comparative output ON/
OFF display color and the normal
display color from red or white.
Display color
setting mode
Settings
initializing mode
DP-M
Main menu for detailed configuration
Operation
setting mode
RUN mode
Flow
DP-0
Digital
* Refer to p.705 for details of operation setting mode.
Functional design
Black body for enhanced visibility of LCD display
The unit body is completely black to make the LCD
display easier to see.
Firm and crisp clicking feel
The buttons offer firm and crisp clicking feel for smooth
and reliable setting operations.
Crisp
clicking feel
Digital Pressure Sensor
DP-0 SERIES
APPLICATIONS
704
FIBER
SENSORS
Suction confirmation for electronic parts
Reference pressure check
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
High-quality LCD display
SENSOR
OPTIONS
Simple and highly visible display
Selection of display color from red or white
The LCD offers a wide viewing angle so the display
is easy to see even from an oblique angle. The
alphanumeric display (12-segment display), the key lock
mark and the OVER mark are also clear and easy to see.
The display color can be selected from red or white
in accordance with the output operation. Since the
detailed setting mode display is pink (unchangeable),
the pressure sensor status can be easily recognized by
color.
Pressure/setting display
Comparative output
ON/OFF display
Key lock icon
OVER mark
Pressure unit display
Display
color setting
Mode
RUN mode
Comparative output ON Comparative output OFF
Red for ON, white for OFF
Red
White
White for ON, red for OFF
White
Red
Red in normal status
Red
White in normal status
White
Low pressure type: kPa, kgf/cm2, bar, psi, mmHg
High pressure type: MPa, kgf/cm2, bar, psi
RUN mode
Detailed mode
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
Pink
HUMAN MACHINE
INTERFACES
Detailed setting mode
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Compact & light weight design
Extra-short depth and light weight
The unit body measures only 24.9 mm 0.980 in in depth
to allow installation in a shallow space. The main unit
weighs only about 25 g. The lightweight unit means
minimal load when mounted on a moving part such as a
robot arm.
Comparison with Depth
: Approx. 41% shorter!
conventional model dimension
Main unit
series standard
( DP-100
: Approx. 38% lighter!
pressure port type ) weight
Conventional model
DP-0 series
(DP-100 series standard pressure port type)
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Approx.
25 g
Approx.
< Actual size >
40 g
DP-0
DP-100
DP-M
24.9 mm
0.980 in
42.5 mm 1.673 in
Low pressure type and high pressure type available
Two types to choose from depending on your application
Ideal for applications such
as suction. No mis-operations
occur due to vacuum
breakdown.
The low pressure type can be used with positive or
negative pressure, while the high pressure type is
suitable for positive pressure of up to 1 MPa.
−100 kPa
Low
pressure type
High
pressure type
0 kPa
DP-001□
Ideal for applications such
as checking reference
100 kPa pressure. Can also be
used for simple suction.
1 MPa
DP-002□
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Three output modes
Equipped with three output modes for use in a wide range of applications
(1) EASY mode
(2) Hysteresis mode
H (Hysteresis)
H (Hysteresis)
H (Hysteresis)
P-1
P-1
P-1
(3) Window comparator mode
This mode is used for setting comparative
output hysteresis to the desired level and for
carrying out ON/OFF control.
This mode is used for comparative output ON/
OFF control.
P-2
P-2
P-2
P-2
P-2
P-2
H (Hysteresis)
H (Hysteresis)
H (Hysteresis)
P-1
P-1
P-1
000
Comparative
Comparative
Comparative
ON
ON
ON
output
output
output OFF
OFF
OFF
000
Comparative
Comparative
Comparative
ON
ON
ON
output
output
output OFF
OFF
OFF
*H: 4 digits (fixed) (10 digits or more when using psi unit)
This mode is used for setting comparative
output ON and OFF at pressures within the
setting range.
Pressure
Pressure
Pressure
LASER
SENSORS
DP-0 SERIES
Pressure
Pressure
Pressure
FIBER
SENSORS
Digital Pressure Sensor
Pressure
Pressure
Pressure
705
*H: 2 digits or more (5 digits or more when using psi unit)
H (Hysteresis)
H (Hysteresis)
H (Hysteresis)
H (Hysteresis)
H (Hysteresis)
H (Hysteresis)
P-1
P-1
P-1
000
Comparative
Comparative
Comparative
ON
ON
ON
output
output
output OFF
OFF
OFF
*H: 4 digits or more (10 digits or more when using psi unit)
Designed for easy installation
Panel mounting bracket
Tight installation is possible
An exclusive mounting bracket
that is suitable for 1 to 3 mm 0.039
to 0.118 in panel thickness is
available.
Panel mounting bracket
MS-DP1-8
Front protection cover
MS-DP1-3
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Neat and
space saving
PLC
HUMAN MACHINE
INTERFACES
Tight insta
llation is
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
possible
A single
mounting hole
Exclusive mounting bracket
Connection cable
Supports tight installation
Cable can be connected with one-touch
Space savings can also be
achieved even when an
L-shaped mounting
bracket is used.
Tight installation is
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
possible
Connector attached cable (2 m 6.562 ft), as an
accessory, can be connected easily with one-touch
connection.
Connection cable *
Positioning bosses for easier
mounting bracket installation
Flow
* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available.
DP-0
MS-DP1-1
DP-100
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory for MS-DP1-1)
DP-M
Types without connector attached cable are
also available
DP-00□-J
Commercially-available connectors can be used for cable
connections. Cables in required length can be used, so this
contributes to reduction in waste of unwanted cables.
Ceiling mounting
Floor mounting
MS-DP1-5
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory for MS-DP1-5)
Rear mounting
Environmentally
friendly
Commercially-available
parts can be used!
* Refer to p.706 for recommended commercially-available connectors.
Digital Pressure Sensor
DP-0 SERIES
ORDER GUIDE
706
FIBER
SENSORS
Model No.
LASER
SENSORS
DP-00 1 - P - J
Rated pressure range
PHOTOELECTRIC
SENSORS
Cable
1 : −100.0 to +100.0 kPa (Low pressure type)
None : Connector attached cable 2 m 6.562 ft
MICRO
PHOTOELECTRIC
SENSORS
2 : 0.000 to +1.000 MPa (High pressure type)
J : Type without connector attached cable
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Comparative output
None : NPN output type
PRESSURE /
FLOW
SENSORS
P : PNP output type
Type
Appearance
Rated pressure range
Low pressure
type
High pressure
type
Pressure port
DP-001
−100.0 to +100.0 kPa
*CN-14A-C2
(Connector attached cable
2 m 6.562 ft ) is attached.
Model No.
DP-001-P
DP-002
0.000 to +1.000 MPa
DP-002-P
Type without connector attached cable
M5 female thread
INDUCTIVE
PROXIMITY
SENSORS
Comparative output
PARTICULAR
USE
SENSORS
NPN open-collector transistor
SENSOR
OPTIONS
PNP open-collector transistor
NPN open-collector transistor
PNP open-collector transistor
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Accessory
Type without connector attached cable CN-14A-C2 is available. When ordering
this type, suffix “-J” to the Model No.
(e.g.) Type without connector attached cable of DP-001-P is “DP-001-P-J”
SIMPLE
WIRE-SAVING
UNITS
•• CN-14A-C2 (Connector attached cable 2 m 6.562 ft)
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
OPTIONS
Designation
HUMAN
MACHINE
INTERFACES
Model No.
CN-14A-C1
Connector
attached cable
Recommended connector
Description
Length: 1 m 3.281 ft
CN-14A-C2 (Note) Length: 2 m 6.562 ft
0.2 mm2 4-core cabtyre cable with
connector on one end
Cable outer diameter: ø3.7 mm
ø0.146 in
CN-14A-C3
Length: 3 m 9.843 ft
CN-14A-C5
Length: 5 m 16.404 ft
CN-14A-R-C1
Length: 1 m 3.281 ft
CN-14A-R-C2
Length: 2 m 6.562 ft
CN-14A-R-C3
Length: 3 m 9.843 ft
CN-14A-R-C5
Length: 5 m 16.404 ft
CN-14A
Set of 10 housings and 40 contacts
MS-DP1-1
Allows sensors to be installed on the flooring or ceiling.
Multiple sensors can also be mounted closely.
MS-DP1-5
Allows sensors to be installed on the wall. Multiple sensors
can also be mounted closely.
Panel mounting
bracket
MS-DP1-8
Allows installation to panels with thickness of 1 to 3 mm 0.039
to 0.118 in. Multiple sensors can also be mounted closely.
Front protection
cover
MS-DP1-3
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket)
Connector
attached cable
Bending-resistant
cable
( )
Connector
Sensor mounting
bracket
Conversion
bushing
MS-DP1-7
2
0.2 mm 4-core bending-resistant
cabtyre cable with connector on
one end
Cable outer diameter: ø3.7 mm
ø0.146 in
Pressure port can be converted to
Rc1/8
Note: The connector attached cable CN-14A-C2 is supplied with the DP-0 series.
female thread.
Contact: SPHD-001T-P0.5,
Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Recommended crimping tool
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Recommended connector (e-CON)
Applicable connector: 37104-3122-000 FL
(Manufactured by 3M Japan Limited)
Selection
Guide
Note: Contact the manufacturer for details
of the recommended products.
Pressure/
Head-separated
Pressure/
Digital Display
Flow
DP-0
DP-100
DP-M
707
FIBER
SENSORS
Digital Pressure Sensor
SPECIFICATIONS
LASER
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Type
Model No.
PHOTOELECTRIC
SENSORS
Item
DP-001
DP-002
PNP output
DP-001-P
DP-002-P
Rated pressure range
Set pressure range
Pressure withstandability
Selectable unit
Supply voltage
Comparative output
Output operation
Flow
DP-0
DP-100
DP-M
0.000 to +1.000 MPa
−0.010 to +1.010 MPa
−0.1 to +10.30 kgf/cm2
−0.1 to + 10.10 bar
−0.1 to +146.5 psi
500 kPa
1.5 MPa
Air, non-corrosive gas
Low pressure type: kPa, kgf/cm2, bar, psi, mmHg
Repeatability
Response time
30 mA or less
NPN open-collector transistor
• Maximum sink current: 50 mA
• Applied voltage: 30 V DC or less
(between comparative output and 0 V)
• Residual voltage: 2 V or less (at 50 mA sink current)
Minimum 2 digits (variable)
±0.2 % F.S. (within ±4 digits)
±0.4 % F.S. (within ±4 digits)
2.5 ms, 25 ms, 250 ms, selectable by key operation
Incorporated
3 + 1/2 digits, 3-color (white / red / pink) LCD display (Display update period: 250 ms)
Displayable
pressure range
Environmental resistance
PNP open-collector transistor
• Maximum source current: 50 mA
• Applied voltage: 30 V DC or less
(between comparative output and +V)
• Residual voltage: 2 V or less (at 50 mA source current)
Selectable either NO or NC by key operation
Short-circuit protection
Display
High pressure type: MPa, kgf/cm2, bar, psi
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Hysteresis
FA
COMPONENTS
Pressure/
Head-separated
−100.0 to +100.0 kPa
−101.0 to +101.0 kPa
−1.030 to +1.030 kgf/cm2
−1.010 to + 1.010 bar
−14.65 to +14.65 psi
−756 to +756 mmHg
Power consumption
ENERGY
MANAGEMENT
SOLUTIONS
Pressure/
Digital Display
Gauge pressure
Applicable fluid
PLC
Selection
Guide
EMC Directive, RoHS Directive
Type of pressure
LASER
MARKERS
UV
CURING
SYSTEMS
High pressure
CE marking directive compliance
STATIC
CONTROL
DEVICES
MACHINE
VISION
SYSTEMS
Low pressure
NPN output
MEASUREMENT
SENSORS
HUMAN
MACHINE
INTERFACES
DP-0 SERIES
−101.0 to +101.0 kPa
−1.030 to +1.030 kgf/cm2
−1.010 to + 1.010 bar
−14.65 to +14.65 psi
−756 to +756 mmHg
−0.010 to +1.010 MPa
−0.1 to +10.30 kgf/cm2
−0.1 to + 10.10 bar
−0.1 to +146.5 psi
Protection
Ambient temperature
Ambient humidity
Voltage withstandability
IP40 (IEC)
0 to +50 °C +32 to +122 °F (No dew condensation allowed), Storage: -10 to +60 °C +14 to +140 °F
35 to 85 % RH, Storage: 35 to 85 % RH
500 V AC for one min. between all supply terminals connected together and enclosure
Insulation resistance
50 MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
Vibration resistance
10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each
Shock resistance
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Pollution degree
2
Overvoltage category
I
Usable altitude
Temperature characteristics
(+20 °C +68 °F standard)
Grounding method
Pressure port
Material
Weight
Accessory
2,000 m 6,562 ft or less
+10 to +40 °C +50 to +104 °F: Within ±1 % F.S.
0 to +50 °C +32 to +122 °F: Within ±2.5 % F.S.
+10 to +40 °C +50 to +104 °F: Within ±2 % F.S.
0 to +50 °C +32 to +122 °F: Within ±5 % F.S.
Floating
M5 female thread
Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Brass (nickel plated)
Mounting threaded part: Brass, O-ring: Nitrile rubber (NBR), Key section: Polycarbonate
25 g approx.
CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1 pc.
Note: Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
Digital Pressure Sensor
DP-0 SERIES
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
LASER
SENSORS
NPN output type
I/O circuit diagram
Terminal arrangement diagram
PHOTOELECTRIC
SENSORS
Terminal No.
MICRO
PHOTOELECTRIC
SENSORS
Color code of connector attached cable
1
Sensor circuit
D1
3
D2
Tr
708
2
(Brown) +V
AREA
SENSORS
(White) Not connected (Note) Load
(Black) Comparative output
+
−
50 mA MAX.
ZD
4
2
3
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
4
Terminal
No.
(Blue) 0 V
Internal circuit
1
12 to 24 V DC
±10 %
Designation
Users’ circuit
+V
Note: Open or, connect to 0 V.
Symbols…D1, D2: Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr: NPN output transistor
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Comparative output
PARTICULAR
USE
SENSORS
Not connected (Note)
SENSOR
OPTIONS
0V
Note: Open or, connect to 0 V.
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
PNP output type
I/O circuit diagram
MEASUREMENT
SENSORS
Terminal arrangement diagram
STATIC
CONTROL
DEVICES
Terminal No.
Color code of connector attached cable
Sensor circuit
D1
Tr
LASER
MARKERS
(Brown) +V
1
ZD
PLC
50 mA MAX.
D2
2
3
4
(Black) Comparative output
(White) Not connected (Note) Load
+
−
(Blue) 0 V
Internal circuit
1
12 to 24 V DC
±10 %
2
3
Terminal
No.
Users’ circuit
HUMAN
MACHINE
INTERFACES
Designation
+V
Note: Open or, connect to 0 V.
Symbols…D1, D2: Reverse supply polarity protection diode
ZD: Surge absorption zener diode
Tr: PNP output transistor
4
Comparative output
Not connected (Note)
0V
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Note: Open or, connect to 0 V.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DP-0
DP-100
DP-M
709
FIBER
SENSORS
Digital Pressure Sensor
PRECAUTIONS FOR PROPER USE
LASER
SENSORS
• Never use this product as a sensing device
for personnel protection.
• In case of using sensing devices for
personnel protection, use products which
meet laws and standards, such as OSHA,
ANSI or IEC etc., for personnel protection
applicable in each region or country.
• This product is used for non-corrosive gas.
The product shall not be used for liquid
or corrosive gas. Never use fluids having
inflammability, toxicity, etc., that affect the
human body, either.
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
DP-0 SERIES
Part description
Refer to p.1566 for general precautions.
Connection
How to connect
•• Insert the cable with connector
CN‑14A(‑R)‑C□ into this product’s
connection connector section as shown
in the right figure.
How to disconnect
•• Pressing the release lever of the cable
with connector, pull out the connector.
Note: Do not pull by holding the cable without pressing the release lever, as
this can cause cable break or connector break.
ON mark
Type
OFF mark
Operation setting
Connecting
connector
Key lock mark
OVER mark
Pressure port
(M5 female thread)
Mode
selection key
Setting value UP key
Setting value DOWN key
Piping
•• When using this product, connect a joint available in the market
to the pressure port. At the time, the tightening torque should be
1.0 N·m or less.
NC
NO
−50.0
0.500
Pressure unit
kPa
MPa
Display color
Red when ON, White when OFF
Response speed
Flow
DP-0
DP-100
DP-M
2.5 ms
Error indication
Error indication
•• Use sensor mounting bracket MS‑DP1‑1 prepared
independently.
When mounting this product with sensor mounting bracket, etc.,
the tightening torque should be 0.5 N·m or less.
M3 (length 6 mm 0.236 in)
screws with washers
(Accessory with MS-DP1-1)
Description
Remedy
The load is short-circuited
causing an overcurrent to
flow.
Turn OFF the power and
check the load.
Pressure is applied during
zero point adjustment.
Applied pressure at the
pressure port should be
brought to atmospheric
pressure and zero-point
adjustment should be done
again.
The applied pressure
exceeds the upper limit of
the displayed pressure
range.
The applied pressure
exceeds the lower limit
(back pressure) of the
displayed pressure range.
Applied pressure range
should be brought within
the rated pressure range.
When other error massage is displayed, contact us.
Selection
Guide
Pressure/
Head-separated
High pressure type
EASY mode
Threshold value
Sensor mounting
bracket MS-DP1-1
(Optional)
Pressure/
Digital Display
Low pressure type
NO/NC setting
Mounting
UV
CURING
SYSTEMS
Cable with connector
CN-14A(-R)-C□
Factory setting
Digital display unit
MACHINE
VISION
SYSTEMS
Release lever
•• Panel mounting bracket MS‑DP1‑8 (optional) and front protection
cover MS‑DP1‑3 (optional) are available.
•• For the method for mounting panel mounting bracket, refer to the
instruction manual that came with the MS‑DP1‑8.
Wiring
•• Make sure that the power supply is OFF while performing the
wiring operation.
•• Verify that the supply voltage variation is within the rating.
•• If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power supply
is connected to an actual ground.
•• In case noise generating equipment (switching regulator, inverter
motor, etc.) is used in the vicinity of this product, connect the
frame ground (F.G.) terminal of the equipment to an actual
ground.
•• When extending the cable, use a cable whose conductor crosssection area is 0.3 mm2 or more. The cable can be extended to
up to 10 m 32.808 ft in total length.
•• Do not run the wires together with high-voltage lines or power
lines or put them in the same raceway. This can cause
malfunction due to induction.
•• Do not apply stress directly to the connection cable leader or to
the connector.
Others
•• This product has been developed / produced for industrial use
only.
•• The product shall be used only within the rated pressure range.
•• Do not apply pressure exceeding the pressure resistance.
Otherwise, destruction of diaphragm occurs, preventing the
product to perform normal operation.
•• Do not use during the initial transient time (0.5 sec.) after the
power supply is switched ON.
•• The specification may not be satisfied in a strong magnetic field.
•• This product is suitable for indoor use only.
•• Take care that strong impact such as fall is not given to this
product. Otherwise, it may be destroyed.
•• Avoid dust, dirt, and steam.
•• Take care that the product does not come into contact with
organic solvents such as thinner.
•• Take care that the product does not come into contact with oil or
grease.
•• Take care that the product does not come into contact with
strong acid or alkaline.
•• Do not insert wire into the pressure port. Otherwise, destruction
of diaphragm occurs, preventing the product to perform normal
operation.
Digital Pressure Sensor
DIMENSIONS (Unit: mm in)
DP-0 SERIES
The CAD data can be downloaded from the website.
DP-00□
Sensor
24.9 0.980
30 1.181
710
20 0.787
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Connector
20 0.787
4.9 0.193
FIBER
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Display
AREA
SENSORS
30
1.181
ø8.35
ø0.329
Setting value DOWN key
Mode selection key
2-ø2.5 0.098, 5 0.197 deep
20
0.787
M5 female thread, 4 0.157 deep
1.3 0.051
2-M3 female thread, 4 0.157 deep
Setting value UP key
MS-DP1-1
Sensor mounting bracket (Optional)
22
0.866
9.5
14.5
0.571 0.374
21
0.827
4.2
0.165
30
1.181
20
0.787
13
0.512
20
R13
0.787 R0.512
t2
t 0.079
PLC
4.9 0.193
(
)
ø8.35 ø0.329
30
1.181
5.5 44
0.217 1.732
20
0.787
LASER
MARKERS
24.9
0.980
45
(1.772
)
45
1.772
15
0.591
Material: Cold rolled carbon steel (SPCC)
(Trivalent uni-chrome plated)
SENSOR
OPTIONS
STATIC
CONTROL
DEVICES
20
0.787
2-ø3.5 ø0.138
5.3
0.209
PARTICULAR
USE
SENSORS
MEASUREMENT
SENSORS
14.5
9.5 0.571
0.374
2-R2.1 R0.083
INDUCTIVE
PROXIMITY
SENSORS
WIRE-SAVING
SYSTEMS
2-R2.1 R0.083
1
0.039
4.2
0.165
PRESSURE /
FLOW
SENSORS
SIMPLE
WIRE-SAVING
UNITS
Assembly dimensions
ø2.3
ø0.091
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
30
t 2 1.181
t 0.079
1.3
0.051
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
30 1.181
UV
CURING
SYSTEMS
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
MS-DP1-5
Sensor mounting bracket (Optional)
Assembly dimensions
22.75
0.896
4.5
0.177
Selection
Guide
R6.75
R0.266
29.5
1.161
20
0.787
Pressure/
Digital Display
Pressure/
Head-separated
ø4.5
ø0.177
28
1.102
16
0.630
Flow
DP-0
8.5 0.335
20
0.787
13.5
0.531
20
0.787
2-ø3.5 ø0.138
DP-100
24.9
0.980
4.9
0.193
44.5
30 1.752
1.181
t 1.5
t 0.059
49.5
(1.949
)
DP-M
ø8.35 ø0.329
49.5
1.949
20
0.787 28.5
1.122
Material: Stainless steel (SUS304)
Two M3 (length 6 mm 0.236 in) screws with
washers are attached.
ø4.5
ø0.177
20
0.787
29.5
1.161
30
1.181
4.5
0.177
1.3
0.051
26.5
1.043
48
1.890
t 1.5
t 0.059
711
FIBER
SENSORS
LASER
SENSORS
Digital Pressure Sensor
DP-0 SERIES
DIMENSIONS (Unit: mm in)
The CAD data can be downloaded from the website.
MS-DP1-7
Conversion bushing (Optional)
PHOTOELECTRIC
SENSORS
Assembly dimensions
15.8
(0.622
)
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
14
0.551
3.5
0.138
PRESSURE /
FLOW
SENSORS
0.5
( 0.020
)
INDUCTIVE
PROXIMITY
SENSORS
11 0.433
PARTICULAR
USE
SENSORS
7.8
0.307
M5 male thread
Gasket
36.4
1.433
8
0.315
10 0.394
Rc1/8 female thread
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Material: Brass (Nickel plated)
Weight: 10 g approx.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
MS-DP1-8 MS-DP1-3
Panel mounting bracket (Optional), Front protection cover (Optional)
Mounting drawing with DP-00□
Panel cut-out dimensions
When 1 unit is installed
PLC
0
31−0.4
0
1.220 −0.016
HUMAN
MACHINE
INTERFACES
0
ENERGY
MANAGEMENT
SOLUTIONS
(39.3 1.547)
34.5 1.358
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
Front protection
cover
4.9 0.193
When “n” units are installed
horizontally in series
ø8.35 ø0.329
( )
34.5 20
1.358 0.787
0
31−0.4
0
1.220 −0.016
0
31−0.4
0
1.220 −0.016
33.4 1.315
33.4
1.315
55 2.165
or more
8.5
0.335
50 1.969
Pressure/
Digital Display
When “n” units are installed
vertically in series
31 1.220 × n + 3.5 0.138 × (n-1)
A
UV
CURING
SYSTEMS
Selection
Guide
0
31−0.4 1.220 −0.016
11
0.433
7.2 12.8
0.283 0.504
31 1.220 × n +
3.5 0.138 × (n-1)
Panel thickness
dimension 1 to 3 mm
0.039 to 0.118 in
Connector
55 2.165
or more
Pressure/
Head-separated
Flow
Note: The panel thickness should be
1 to 3 mm 0.039 to 0.118 in.
(52 2.047 max.)
Note: The panel thickness should be
1 to 3 mm 0.039 to 0.118 in.
View A
DP-0
DP-100
Material: Polyacetal (Panel mounting bracket)
Polycarbonate (Front protection cover)
DP-M
CN-14A(-R)-C□
Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
L
(
35
1.378
(0.3158 )
)
50
(1.969
)
ø3.7 ø0.146 cable
Model No.
(0.3158 )
Cable length L (mm in)
CN-14A(-R)-C1
1,000 39.370
CN-14A(-R)-C2
2,000 78.740
CN-14A(-R)-C3
3,000 118.110
CN-14A(-R)-C5
5,000 196.850
712