Enclosed Switch
D4C
CSM_D4C_DS_E_10_2
Compact Limit Switch That's Also
Thin and Highly Sealed
• Approved by EN, UL, CSA, and CCC (Chinese standard).
(Ask your OMRON representative for information on
approved models.)
• Sealing characteristics that meet IEC IP67 degree of
protection.
• Triple-sealed construction:
Plunger section sealed via nitrile rubber packing seal and
diaphragm; switch section sealed via nitrile rubber cap;
cable entrance sealed via encapsulating material.
• Cable lengths of 3 and 5 m available on standard models.
Models also available with UL and CSA-certified cables.
• Multiple mounting possible with Switches with Plungers.
• Models with red LED indicators added to series for easy
confirmation of operation.
(Set by default to light for non-operation.)
• VCTF oil-resistant cables with CE marking.
(Applicable only to standard models.)
For the most recent information on models that have been certified for
safety standards, refer to your OMRON website.
Be sure to read Safety Precautions on page 13 to 14 and
Safety Precautions for All Limit Switches.
Model Number Structure
Model Number Legend (Not all combinations are possible. Ask your OMRON representative for details.)
Standard Models
Pre-wired Models
D4C-@@@
D4C-@0@@-@@@@@@
(1)(2)(3)
(1)
(2)
Weather-resistant Models
(3)
(4)
D4C-@@@-P
(1)(2)(3) (4)
(1) Rated Current
(1) Rated Current
(1) Rated Current
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
5: 0.1 A at 125 VAC (with LED indicator)
6: 0.1 A at 30 VDC (with LED indicator)
1: 1 A at 125 VAC, 1 A at 30 VDC
(Without operation indicator)
2: 1 A at 125 VAC (with operation indicator)
3: 1 A at 30 VDC (with operation indicator)
1: 5 A at 250 VAC, 4 A at 30 VDC
2: 5 A at 125 VAC (with LED indicator)
3: 4 A at 30 VDC (with LED indicator)
4: 0.1 A at 125 VAC, 0.1 A at 30 VDC
(2) Actuator
(2) Cable Specifications
01: Pin plunger
02: Roller plunger
31: Sealed plunger
32: Sealed roller plunger
24: Roller lever (high-sensitivity model)
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
(2) Cable Specifications
2: VCTF oil-resistant cable (3 m)
3: VCTF oil-resistant cable (5 m)
4: VCTF (3 m)
5: VCTF (5 m)
6: SJT(O) (3 m)
7: SJT(O) (5 m)
(3) Actuator
01: Pin plunger
02: Roller plunger
03: Crossroller plunger
20: Roller lever
24: Roller lever (high-sensitivity model)
31: Sealed pin plunger
32: Sealed roller plunger
33: Sealed crossroller
50: Plastic rod
60: Center roller lever
(3) Wiring Specifications
DK1EJ: Pre-wired models
(3 conductors: DC specification)
AK1EJ: Pre-wired models
(3 conductors: AC specification)
M1J: Connector models for ASI devices
(2 conductors: NO wiring)
(3) Actuator
20: Roller lever
24: Roller lever (high-sensitivity model)
27: Adjustable roller lever
29: Adjustable rod lever
(4) Structure
P: Weather-resistant
(4) Cable length
03: 0.3 m
Wiring Specifications
Internal switch
Connector
COM
3
NC
2
NO
4
1
D4C
Ordering Information
Switches
Standard Switches with No Operation Indicator
Actuator
Ratings
Cable
Cable
length
(m)
VCTF oil-resistant
cable *1
Standard load
Microload
5 A at 250 VAC, 4 A at 30 VDC
0.1 A at 125 VAC, 0.1 A at 30 VDC
VCTF cable *2
SJT(O) cable *3
VCTF oil-resistant
cable *1
VCTF cable *2
Model
3
D4C-1201
D4C-1401
D4C-1601
D4C-4201
D4C-4401
5
D4C-1301
D4C-1501
D4C-1701
D4C-4301
D4C-4501
3
D4C-1202
D4C-1402
D4C-1602
D4C-4202
D4C-4402
5
D4C-1302
D4C-1502
D4C-1702
D4C-4302
D4C-4502
3
D4C-1203
D4C-1403
D4C-1603
D4C-4203
D4C-4403
5
D4C-1303
D4C-1503
D4C-1703
D4C-4303
D4C-4503
3
D4C-1220
D4C-1420
D4C-1620
D4C-4220
D4C-4420
5
D4C-1320
D4C-1520
D4C-1720
D4C-4320
D4C-4520
3
D4C-1224
D4C-1424
D4C-1624
D4C-4224
D4C-4424
5
D4C-1324
D4C-1524
D4C-1724
D4C-4324
D4C-4524
3
D4C-1231
D4C-1431
D4C-1631
D4C-4231
D4C-4431
5
D4C-1331
D4C-1531
D4C-1731
D4C-4331
D4C-4531
3
D4C-1232
D4C-1432
D4C-1632
D4C-4232
D4C-4432
5
D4C-1332
D4C-1532
D4C-1732
D4C-4332
D4C-4532
3
D4C-1233
D4C-1433
D4C-1633
D4C-4233
D4C-4433
5
D4C-1333
D4C-1533
D4C-1733
D4C-4333
D4C-4533
3
D4C-1250
D4C-1450
D4C-1650
D4C-4250
D4C-4450
5
D4C-1350
D4C-1550
D4C-1750
D4C-4350
D4C-4550
3
D4C-1260
D4C-1460
D4C-1660
D4C-4260
D4C-4460
5
D4C-1360
D4C-1560
D4C-4360
D4C-4560
Pin plunger
Roller plunger
Crossroller
plunger
Roller lever
Roller lever,
highsensitivity
Sealed pin
plunger
Sealed roller
plunger
Sealed
crossroller
plunger
Plastic rod
Center roller
lever
---
Note: 1. Models are available separately with resistance to viscous oils (oil drain holes are provided), but only with Plunger Models. Add “-M” to the model number
(example: D4C-1202 would be D4C-1202-M). Ask your nearest OMRON representative for details.
2. Switches with variable roller levers are also available. Ask your nearest OMRON representative for details.
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables; approved by EN and IEC.
*3. Switches with SJT(O) Cables (cables approved by UL and CSA) are approved by UL and CSA.
2
D4C
Standard Switches with Operation Indicator (Red)
Actuator
Ratings
Cable
Cable
length (m)
0.1 A at 125 VAC
VCTF oil-resistant
cable *1
0.1 A at 30 VDC
VCTF oil-resistant
cable *1
VCTF cable *2
VCTF cable *2
Model
3
D4C-2201
D4C-2401
D4C-3201
D4C-3401
5
D4C-2301
D4C-2501
D4C-3301
D4C-3501
3
D4C-2202
D4C-2402
D4C-3202
D4C-3402
5
D4C-2302
D4C-2502
D4C-3302
D4C-3502
3
D4C-2203
D4C-2403
D4C-3203
D4C-3403
5
D4C-2303
D4C-2503
D4C-3303
D4C-3503
3
D4C-2220
D4C-2420
D4C-3220
D4C-3420
5
D4C-2320
D4C-2520
D4C-3320
D4C-3520
3
D4C-2224
D4C-2424
D4C-3224
D4C-3424
5
D4C-2324
D4C-2524
D4C-3324
D4C-3524
3
D4C-2231
D4C-2431
D4C-3231
D4C-3431
5
D4C-2331
D4C-2531
D4C-3331
D4C-3531
3
D4C-2232
D4C-2432
D4C-3232
D4C-3432
5
D4C-2332
D4C-2532
D4C-3332
D4C-3532
3
D4C-2233
D4C-2433
D4C-3233
D4C-3433
5
D4C-2333
D4C-2533
D4C-3333
D4C-3533
3
D4C-2250
D4C-2450
D4C-3250
D4C-3450
5
D4C-2350
D4C-2550
D4C-3350
D4C-3550
3
D4C-2260
D4C-2460
D4C-3260
D4C-3460
5
D4C-2360
D4C-2560
D4C-3360
D4C-3560
Pin plunger
Roller plunger
Crossroller
plunger
Roller lever
Roller lever,
highsensitivity
Sealed pin
plunger
Sealed roller
plunger
Sealed
crossroller
plunger
Plastic rod
Center roller
lever
Note: Ask your nearest OMRON representative for information on Switching with approved international standards.
*1. Oil-resistant vinyl cabtire cables; approved by EN and IEC.
*2. Ordinary vinyl cabtire cables.; approved by EN and IEC.
3
D4C
Standard Switches with Operation Indicator
Actuator
Ratings
Cable
Cable length (m)
3
Pin plunger
0.1 A at 125 VAC
0.1 A at 30 VDC
VCTF oil-resistant cable*
VCTF oil-resistant
cable*
Model
D4C-5201
Roller plunger
Crossroller plunger
Roller lever
Roller lever, highsensitivity
D4C-5202
D4C-6202
5
D4C-5302
D4C-6302
3
D4C-5203
D4C-6203
5
D4C-5303
D4C-6303
3
D4C-5220
D4C-6220
5
D4C-5320
D4C-6320
3
D4C-5224
D4C-6224
5
D4C-5324
5
Sealed roller plunger
3
D4C-5232
5
D4C-5332
3
Sealed
crossroller plunger
5
Plastic rod
D4C-6301
3
3
Sealed pin plunger
D4C-6201
---
5
D4C-6324
---
D4C-6231
---
D4C-6331
D4C-6232
D4C-6332
---
D4C-6233
---
D4C-6333
3
D4C-5250
D4C-6250
5
D4C-5350
D4C-6350
Note: Ask your nearest OMRON representative for information on Switching with approved international standards.
* Oil-resistant vinyl cabtire cables; approved by EN and IEC.
Pre-wired Models (Use VCTF Oil-resistant Cable)
Ratings
1 A at 125 VAC
Operation
indicator
1 A at 30 VDC
Without operation indicator
With operation indicator
Without operation indicator
With operation indicator
---
---
---
D4C-3001-DK1EJ@
Roller plunger
D4C-1002-AK1EJ@
D4C-2002-AK1EJ@
D4C-1002-DK1EJ@
D4C-3002-DK1EJ@
Sealed plunger
---
---
---
D4C-3031-DK1EJ@
Sealed roller plunger
---
---
D4C-1032-DK1EJ@
D4C-3032-DK1EJ@
Roller lever (highsensitivity model)
---
D4C-2024-AK1EJ@
D4C-1024-DK1EJ@
D4C-3024-DK1EJ@
Actuator
Pin plunger
Note: 1. The @ contains the length of the cable.
For example: 30 cm → D4C-2002-AK1EJ03
2. M1J models are also available. Contact your OMRON sales representative for further information.
3. Of the above model numbers, some with special specifications are not registered.
Weather-resistant Models
Operation
indicator
Ratings
Without operating indication
With operating indication
Standard load
Microload
5 A at 250 VAC
4 A at 30 VDC
0.1 A at 125 VAC
0.1 A at 30 VDC
Standard load
5 A at 125 VAC
4 A at 30 VDC
VCTF oil-resistant cable
Actuator
Roller lever
Roller lever (highsensitivity model)
Adjustable roller lever
Adjustable rod lever
Cable length (m)
Model
3
D4C-1220-P
D4C-4220-P
D4C-2220-P
5
D4C-1320-P
---
---
D4C-3220-P
---
3
D4C-1224-P
D4C-4224-P
D4C-2224-P
D4C-3224-P
5
D4C-1324-P
D4C-4324-P
D4C-2324-P
D4C-3324-P
3
D4C-1227-P
D4C-4227-P
D4C-2227-P
D4C-3227-P
5
D4C-1327-P
D4C-4327-P
D4C-2327-P
D4C-3327-P
3
D4C-1229-P
D4C-4229-P
---
D4C-3229-P
5
D4C-1329-P
---
D4C-2329-P
D4C-3329-P
Note: Silicon rubber is used to increase resistance to the environment. Silicon rubber, however, can generate silicon gas. (This can occur at room temperature, but the
amount of silicon gas generated increases at higher temperatures.) Silicon gas will react as a result of arc energy and form silicon oxide (SiO2). If silicon oxide
accumulates on the contacts, contact interference can occur and can interfere with the device. Before using a Switch, test it under actual application conditions
(including the environment and operating frequency) to confirm that no problems will occur in actual.
4
D4C
Applicable Cables
Type
No. of
conductors
Appearance
For AC
For DC
Model
Model
2m
XS2F-A421-D90-F
XS2F-D421-D80-F
5m
XS2F-A421-G90-F
XS2F-D421-G80-F
Cable length
Straight
4
Mounting Plates (Order Separately)
The WL model incorporated by equipment can be replaced with the D4C together with the Mounting Plate without changing the position
of the dog or cam.
List of Replaceable Models
WL model (Actuator)
Example of Replacement
D4C model (Actuator)
Plate
WLD/WL01D
(Top plunger)
D4C-@@01
(Plunger)
D4C-P001
WLD2/WL01D2
(Top roller plunger)
D4C-@@02
(Roller plunger)
D4C-P002
WLCA2/WL01CA2
(Roller lever)
D4C-@@20
(Roller lever)
D4C-P020
Note: The position of the dog remains unchanged.
Dog
Dog
Note: The WL01@ is for micro loads.
Mounting
Plate
Individual Parts
Head/Actuator
Actuator
Head (with actuator)
Actuator
Pin plunger
D4C-0001
---
Roller plunger
D4C-0002
---
Crossroller plunger
D4C-0003
Roller lever
D4C-0020
Roller lever (weather-resistant model)
---
--WL-1A100
WL-1A100P1
Roller lever (high-sensitivity model)
D4C-0024
WL-1A100
Variable roller lever
D4C-0027
Variable rod lever
D4C-0029
Sealed pin plunger
D4C-0031
---
Sealed roller plunger
D4C-0032
---
Sealed crossroller plunger
D4C-0033
---
Plastic rod
D4C-0050
---
Center roller lever
D4C-0060
---
--HL-1HPA500
Note: 1. The model numbers for heads are of the form D4C-00@@, with the numbers in the squares indicating the type of actuator.
2. Actuators for plunger models, plastic rod models, and center roller lever models cannot be ordered individually. They must be ordered together with the head.
5
D4C
Specifications
Approved Standards
Agency
TÜV Product
Service
Standard
File No.
EN60947-5-1
*1, 3
UL
UL508
CSA
CSA C22.2 No.14
E76675
LR45746 *2
*2
CCC(CQC)
GB14048.5
2003010305077626 *3
*1. Models with VCTF, VCTF oil-resistant cables and pre-wired models only.
(Applicable only to standard models listed on pages 2 to 4.)
“CE” mark is applicable only for VCTF oil-resistant cables and pre-wired models.
*2. SJT(O)-cable models only.
(Applicable only to models listed on pages 2 to 3.)
*3. Ask your OMRON representative for information on approved models.
Ratings
Standard Model
Rated voltage
125 VAC
250 VAC
8 VDC
14 VDC
30 VDC
125 VDC
250 VDC
Non-inductive load (A)
Resistive load
Lamp load
NC
NO
NC
NO
5 (0.1)
1.5
0.7
5
1
0.5
5 (0.1)
2
5 (0.1)
2
4 (0.1)
2
0.4
0.05
0.2
0.03
Inductive load (A)
Inductive load
Motor load
NC
NO
NC
NO
3
2.5
1.3
2
1.5
0.8
5
4
3
4
4
3
3
3
3
0.4
0.05
0.2
0.03
Non-inductive load (A)
Resistive load
Lamp load
NC
NO
NC
NO
1
1
1
0.7
1
1
1
1
Inductive load (A)
Inductive load
Motor load
NC
NO
NC
NO
1
1
1
1
1
1
1
1
Inrush
current
NC
20 A max.
NO
10 A max.
Note: 1. The values given on the left are steady-state
currents.
2. Inductive loads have a power factor of 0.4 min.
(AC) and a time constant of 7 ms max. (DC).
3. Lamp loads have an inrush current of 10 times
the steady-state current.
4. Motor loads have an inrush current of 6 times
the steady-state current.
5. The values "0.1" given in parentheses are for
micro load models.
Pre-wired Model
Rated voltage
125 VAC
30 VDC
Approved Standard Ratings
Characteristics
TÜV (EN60947-5-1), CCC (GB14048.5)
Degree of protection
Durability Mechanical *3
*1
Electrical *2
Model
Applicable category and
ratings
D4C-1@@@
AC-15 2 A/250 V
DC-12 2 A/30 V
5A
4A
D4C-2@@@
AC-15 2 A/125 V
5A
D4C-3@@@
DC-12 2 A/30 V
D4C-4@@@
AC-14 0.1 A/125 V
DC-12 0.1 A/30 V
D4C-5@@@
AC-14 0.1 A/125 V
0.5 A
D4C-6@@@
DC-12 0.1 A/30 V
0.5 A
I the
4A
0.5 A
0.5 A
UL/CSA
B300 (D4C-16@@, -17@@)
B150 (D4C-26@@, -27@@)
B300
Rated voltage
120 VAC
240 VAC
Carry current
5A
Current (A)
Volt-amperes (VA)
Make
Break
Make
Break
30
15
3
1.5
3,600
3,600
360
360
B150
Rated voltage
Carry current
120 VAC
5A
Current (A)
Volt-amperes (VA)
Make
Break
Make
Break
30
3
3,600
360
Operating speed
Operating Mechanical
frequency Electrical
Rated frequency
Insulation resistance
Contact resistance (initial)
Between terminals of
the same polarity
Between currentDielectric carrying metal
part and ground
strength
Between each terminal
and non-current-carrying metal part,
Rated insulation voltage (Ui)
Pollution degree (operating environment)
Short-circuit protective device (SCPD)
Conditional short-circuit current
Conventional enclosed
thermal current (I the)
Protection against electric shock
Vibration reMalfunction
sistance
Shock re- Destruction
sistance
Malfunction
Ambient operating temperature
Ambient operating humidity
Weight (D4C-1202)
IP67
10,000,000 operations min.
200,000 operations min. (5 A at 125 VAC, resistive load)
0.1 mm/s to 0.5 m/s (in case of plunger)
1 mm/s to 1 m/s (in case of roller lever)
120 operations/min
30 operations/min
50/60 Hz
100 MΩ min. (at 500 VDC)
250 mΩ max. (initial value with 2-m VCTF cable)
300 mΩ max. (initial value with 3-m VCTF cable)
400 mΩ max. (initial value with 5-m VCTF cable)
1,000 VAC, 50/60 Hz for 1 min
1,500 VAC, 50/60 Hz for 1 min
Uimp: 2.5 kV (EN60947-5-1)
1,500 VAC, 50/60 Hz for 1 min
Uimp: 2.5 kV(EN60947-5-1)
300 V (EN60947-5-1) *5
3 (EN60947-5-1)
10 A fuse type gI or gG (IEC60269)
100 A (EN60947-5-1)
5 A, 4 A, 0.5 A (EN60947-5-1)
Class I (with grounding wire) *6
10 to 55 Hz, 1.5-mm double amplitude *4
1,000 m/s2 max.
500 m/s2 max. *4
−10°C to +70°C (with no icing)
35% to 95%RH
With 3-m VCTF cable: 360 g
With 5-m VCTF cable: 540 g
Note: The above figures are initial values.
*1. The values are calculated at an operating temperature of +5°C to +35°C,
and an operating humidity of 40% to 70%RH. Contact your OMRON sales
representative for more detailed information on other operating
environments.
*2. Pre-wired Models: 1,000,000 operations min. (DC specifications, switching
current: 0.1 A)
*3. Outdoor specifications: 500,000 operations min.
*4. Excluding Plastic Rods.
*5. Pre-wired models: 250 V
*6. Pre-wired models: class III
6
D4C
Electrical Durability
D4C-1@@@, -2@@@, -3@@@
D4C-4@@@, -5@@@, -6@@@
Durability (x 104 operations)
Durability (x 104 operations)
Engineering Data
500
Operating temperature: 20±2°C
Operating humidity: 65±5°C
Operating frequency: 30 operations/min
(cosΦ= 1, L/R = 0)
300
100
125 VAC
50
30
1,000
700
500
300
125 VAC
100
50
30
30 VDC
250 VAC
10
Operating temperature: 5°C to 35°C
Operating humidity: 40% to 70%
Operating frequency: 30 operations/min
(cosΦ=1, L/R = 0)
10
5
5
3
3
1
0
1
2
3
4
5
6
7
Switching current (mA)
0
20
40
60
80
100
120
Switching current (mA)
Leakage Current for LED-indicator Models
The leakage currents and resistances of LED-indicator models are given in the following table.
Model
Voltage
Leakage current
Resistance
D4C-2@@@
125 VAC
1.7 mA
68 kΩ
D4C-3@@@
30 VDC
1.7 mA
15 kΩ
D4C-5@@@
125 VAC
1.7 mA
68 kΩ
D4C-6@@@
30 VDC
1.7 mA
15 kΩ
Structure and Nomenclature
Structure
Standard Models
Roller Lever Models Without Indicator
Roller
O-ring
(NBR)
Lever
O-ring
(NBR)
Diaphragm (NBR)
Protective cap
(NBR)
Built-in switch
Molded resin
Ground terminal
Cable
Weather-resistant Models
Roller Lever Models Without Indicator
Roller
The roller is made of self-lubricating sintered
stainless steel and boasts high resistance to
wear.
Shaft Section Seal
By fitting an O-ring to the rotary shaft and with
an appropriate interference of the screws,
high-sealing properties are maintained. The O-ring
is made of silicone rubber and is resistant to temperature
changes and adverse weather conditions.
Head-mounting
Screw
Diaphragm
The diaphragm is made of silicone rubber
and is resistant to temperature changes
and adverse weather conditions.
Cable
Vinyl cabtire cable and is resistant
to adverse weather conditions.
Lever
The lever forged of anti-corrosive aluminium
alloy features high corrosion resistances
and outstanding ruggedness.
Roller Lever Setscrew
This screw is made of stainless steel and has high
corrosion resistance.
Rotary Shaft
The shaft is made of stainless steel
decreasing the likelihood of rusting.
Built-in Switch
Both standard load and microload models available.
7
D4C
Contact Form
Pre-wired Models (-AK1EJ@, -DK1EJ@)
Without Operation Indicator
Standard Models/Weather-resistant Models
Without Operation Indicator
(black)COM
NC (red)
NC Pin No.2
Pin No.3 COM
*2
NO *1
NO Pin No.4
E
E *3
With Operation Indicator
With Operation Indicator
(Lit when Not Actuated)
(Lit when Not Actuated)
(black) COM
NC (red)
Pin No.3 COM
NC Pin No.2
*2
NO *1
NO Pin No.4
E
E *3
15 kΩ
15 kΩ
NC (red)
(black) COM
NC Pin No.2
Pin No.3 COM
*2
NO *1
NO Pin No.4
E
E *3
68 kΩ
68 kΩ
Connector Models for ASI Devices (-M1J)
Without Operation Indicator
For AC
For DC
Positioning piece*4
Positioning piece*4
NC
NC
NO
NO
COM
COM
Pin No.3 COM
NO Pin No.4
With Operation Indicator
(Lit when Not Actuated)
Pin No.3 COM
NO Pin No.4
R
*1. NO (white): VCTF oil-resistant cable or VCTF cable.
NO (blue): SJT (O) cable approved by UL and CSA.
*2. E (yellow/green): VCTF oil-resistant cable.
E (green): VCTF cable or SJT (O) cable approved by UL and CSA.
*3. E (ground) is not grounded.
*4. The position of the positioning piece is not fixed. Using an L-shaped
connector may result in failure. Use only a straight connector.
Note: 1. “Lit when not Actuated” means that when the actuator is in the free
position, the indicator is lit, and when the actuator is turned or pushed and
the contact comes into contact with the NO side, the indicator turns OFF.
2. Leakage current from indicator circuit may cause load's malfunction.
Please check the load's OFF current before use the indicator-equipped
switch.
For DC
Positioning piece*4
NO
COM
8
D4C
Dimensions and Operating Characteristics
Switches
Models without LED indicators are shown in the illustrations and dimensions diagrams. Refer to page 11 for Models with LED Indicators.
The boxes in the model numbers are replaced with the rating and cable type. Refer to page 1 for the Model Number Structure.
Standard Models
Pin Plunger
D4C-@@01
Roller Lever
D4C-@@20
D4C-@@20-P
10 dia. stainless
steel plunger
40 max.
25±0.1
PT
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
17.5 dia. x 7 stainless
sintered roller
50 max.
44±0.8
30.2±0.8
40 max.
25±0.1
2.8
4.5
7.5
OP
54.2 max.
16
Correct
setting
position
8
31.5±0.8
49 max.
2
38R
23
102.7 max.
7
VCTF cable,
0.75 mm2,
4 conductor
Finishing O.D.: 7.6
1.4
2
Roller Plunger
D4C-@@02
11.4
7.5
8 M5 (length: 12)
Allen-head
bolt
23
1.5
2
34
40 max.
25±0.1
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
OP
16
VCTF cable, *
0.75 mm2,
4 conductor
Finishing
O.D.: 7.6
Correct
setting
position
2.8
8
Roller Lever (High-Sensitivity Model)
D4C-@@24
17.5 dia. x 7 stainless
sintered roller
D4C-@@24-P
51.5 max.
2
1.4
2
23
50 max.
44±0.8
30.2±0.8
40 max.
25±0.1
VCTF cable,
0.75 mm2,
4 conductor
Finishing O.D.: 7.6
Crossroller Plunger
D4C-@@03
1.4
2
1.5
34
PT
31.5±0.8
38R
12 dia. x 4.4 stainless steel roller
40 max.
25±0.1
+0.2
0
Two, 5.1
dia.
holes
Spot facing
10.2 dia. Depth: 6
16
11.4
7
7.5
8 M5 (length: 12)
Allen-head
bolt
23
2.8
7
7.5
67 max.
23
VCTF cable, *
0.75 mm2,
4 conductor
Finishing
O.D.: 7.6
65 max.
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
8
51.5 max.
2
16
102.7 max.
Correct
setting
position
2
OP
1.5
34
* S-FLEX VCTF Cables are used for weather-resistant models.
7
7.5
67 max.
65 max.
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
12 dia. x 4.4 stainless steel roller
PT
16
2
1.4
1.5
34
* S-FLEX VCTF Cables are used for weather-resistant models.
VCTF cable,
0.75 mm2,
4 conductor
Finishing O.D.: 7.6
2
1.4
1.5
34
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating
characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
Operating Position OP
max.
min.
max.
min.
max.
D4C-@@01
D4C-@@02
D4C-@@03
D4C-@@20
D4C-@@20-P
D4C-@@24
D4C-@@24-P
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
5.69 N
1.47 N
25°
40°
3°
5.69 N
1.47 N
10°±3°
50°
3°
15.7±1 mm
28.5±1 mm
28.5±1 mm
---
---
9
D4C
Sealed Plunger
D4C-@@31
Sealed Roller Plunger
D4C-@@32
10 dia. stainless
steel plunger
Rubber cap
40 max.
Two, 5.1 +0.2
0 dia.
25±0.1
holes
Spot facing
10.2 dia. Depth: 6
PT
OP
12 dia. x 4.4 stainless
steel roller
40 max.
25±0.1
PT
16
OP
Rubber cap
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
4.0
7.5
16
4.0
7.5
8
8
49 max.
49 max.
2
VCTF cable,
0.75 mm2,
4 conductor
Finishing O.D.: 7.6
2
23
1.4
2
VCTF cable,
0.75 mm2,
4 conductor
Finishing O.D.: 7.6
1.5
34
Sealed Crossroller Plunger
D4C-@@33
2
23
1.4
1.5
34
12 dia. x 4.4 stainless
steel roller
40 max.
25±0.1
PT
OP
Rubber cap
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
16
4.0
7.5
8
49 max.
2
VCTF cable,
0.75 mm2,
4 conductor
Finishing O.D.: 7.6
2
23
1.4
1.5
34
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Operating
characteristics
Model
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
Operating Position
Total travel
OP
TT *
max.
min.
max.
min.
max.
D4C-@@31
D4C-@@32
D4C-@@33
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
24.9±1 mm
(5) mm
34.3±1 mm
(5) mm
34.3±1 mm
(5) mm
* The TT is a reference value.
10
D4C
Plastic rod
D4C-@@50
Center Roller Lever Plunger
D4C-@@60
Nylon rod
40 max.
25±0.1
*1
16
40 max.
25±0.1
*2
38
17.5 dia. x 7 stainless
sintered roller
3.2 dia.
6.6 dia.
Rubber cap
104±2.5
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
42
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
38R
56.9
102.7 max.
4.5
7.5
7 11.4
18.9
7.5
8
8
49 max.
2
VCTF cable,
0.75 mm2,
4 conductor
Finishing O.D.: 7.6
23
2
1.4
2
23
VCTF cable,
0.75 mm2,
4 conductor
Finishing O.D.: 7.6
1.5
1.4
2
34
34
1.5
16
*1 Operation is possible in any direction except in parallel to the axis.
*2 The ideal range for operation is between the tip of the rod and 1/3 of
the length of the actuator.
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Operating
characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
Models with LED Indicator
Model
OF
RF
PT
OT
MD
max.
min.
max.
min.
max.
Operating Position OP
Total travel
TT
D4C-@@50
D4C-@@60
1.47 N
--15°
-----
6.67 N
1.47 N
10°±3°
50°
3°
-----
-----
The dimensions of the LED
indicator for models equipped with
one are shown below.
(4)
LED
Pre-wired Models
Pin Plunger
D4C-@001-@K1EJ@
D4C-@001-M1J@
PT
10 dia. stainless
steel plunger
Two, 5.1 +0.2
0 dia.
40 max.
holes
25±0.1
Spot facing
10.2 dia. Depth: 6
16
Correct setting
position
PT
12 dia. x 4.4 stainless
steel roller
40 max.
25±0.1
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
2.8
4.5
7.5
OP
54.2 max.
Roller Plunger
D4C-@002-@K1EJ@
D4C-@002-M1J@
OP
67 max.
2
Correct setting
position
2.8
7
7.5
8
49 max.
16
8
51.5 max.
23
2
23
2
2
1.5
34
1.5
1.4
34
6 dia.
1.4
6 dia.
XS2H-D421
XS2H-D421
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating
characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
Operating Position OP
max.
min.
max.
min.
max.
D4C-@001
-@K1EJ@
D4C-@002
-@K1EJ@
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
11.77 N
4.41 N
1.8 mm
3 mm
0.2 mm
15.7±1 mm
28.5±1 mm
Note: Specifications are the same for -M1J Switches.
11
D4C
Sealed Pin Plunger
D4C-@031-@K1EJ@
D4C-@031-M1J@
10 dia. stainless
Sealed Roller Plunger
D4C-@032-@K1EJ@
D4C-@032-M1J@
steel plunger
Rubber cap
40 max.
25±0.1
PT
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
OP
40 max.
25±0.1
PT
16
4.0
7.5
12 dia. x 4.4 stainless
steel roller
Rubber cap
16
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
OP
4.0
7.5
8
49 max.
8
2
49 max.
23
2
23
2
2
1.5
34
1.5
1.4
34
1.4
6 dia.
6 dia.
XS2H-D421
XS2H-D421
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Model
Operating
characteristics
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
Operating Position
OP
max.
min.
max.
min.
max.
D4C-@031
-@K1EJ@
D4C-@032
-@K1EJ@
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
17.65 N
4.41 N
1.8 mm
3 mm
0.2 mm
24.9±1 mm
34.3±1 mm
Note: Specifications are the same for -M1J Switches
Roller Lever (High-sensitivity Model)
D4C-@024-@K1EJ@
D4C-@024-M1J@
17.5 dia. x 7 stainless
sintered roller
50 max.
44±0.8
30.2±0.8
40 max.
25±0.1
31.5±0.8
38R
102.7 max.
7
16
11.4
7.5
8
2
M5 (length: 12)
Allen-head bolt
65 max.
23
2
34
Two, 5.1 +0.2
0 dia.
holes
Spot facing
10.2 dia. Depth: 6
1.5
1.4
6 dia.
XS2H-D421
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Operating
characteristics
Model
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
Operating Position
OP
max.
min.
max.
min.
max.
D4C-@024-@K1EJ@
5.69 N
1.47 N
10°±3°
50°
3°
---
Note: Specifications are the same for -M1J Switches
12
D4C
Weather-resistant Models
Adjustable Roller Lever
D4C-@@27-P
40 max.
25±0.1
Adjustable Rod Lever
D4C-@@29-P
17.5 dia. x 7 stainless
steel roller
55 max.
40 max.
25±0.1
57.7 max.
52.3±0.8
31.5±0.8
5.4
44
31.5
3 dia. x 160 stainless
steel lever
Two, 5.1 +0.2
0 dia. holes
Spot facing 10.2 dia.
Depth: 6
16
16
30R to 75R (variable)
M5 (length: 16)
Allen-head bolt
11.4
7
11.4
7
7.5
7.5
8
2
2
23
Two, 5.1 +0.2
0 dia. holes
Spot facing 10.2 dia. Depth: 6
23
M5 (length: 12)
Allen-head bolt
2
VCTF cable, 0.75 mm2,
4 conductor Finishing O.D.: 7.6
2
65 max.
8
65 max.
M5 (length: 12)
Allen-head bolt
M5 (length: 16)
Allen-head bolt
1.4
1.5
VCTF cable, 0.75 mm2,
4 conductor Finishing O.D.: 7.6
2
1.4
1.5
34
34
Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions.
Operating
characteristics
Model
Operating force
Release force
Pretravel
Overtravel
Movement Differential
OF
RF
PT
OT
MD
D4C-@@27-P
D4C-@@29-P *
5.69 N
1.47 N
25°
40°
3°
5.69 N
1.47 N
25°
40°
3°
max.
min.
max.
min.
max.
* Operation characteristics for the D4C-@@27-P and D4C- @@29-P are for a lever length of 38 mm.
Safety Precautions
Refer to Safety Precautions for All Limit Switches.
Precautions for Correct Use
Handling
Operating Environment
• Seal material may deteriorate if a Switch is used outdoor or where
subject to special cutting oils, solvents, or chemicals. Always
appraise performance under actual application conditions and set
suitable maintenance and replacement periods.
• Install Switches where they will not be directly subject to cutting
chips, dust, or dirt. The Actuator and Switch must also be protected
from the accumulation of cutting chips or sludge.
Not Suitable
The bottom of the Switch at the cable outlet is resin-molded. Secure
the cable at a point 5 cm from the Switch bottom to prevent exertion
of excess force on the cable.
When bending the cable, provide a bending radius of 45 mm min. so
as not to damage the cable insulation or sheath. Excessive bending
may cause fire or leakage current.
Suitable
• Constantly subjecting a Switch to vibration or shock can result in
wear, which can lead to contact interference with contacts,
operation failure, reduced durability, and other problems.
Excessive vibration or shock can lead to false contact operation or
damage. Install Switches in locations not subject to shock and
vibration and in orientations that will not produce resonance.
• The Switches have physical contacts. Using them in environments
containing silicon gas will result in the formation of silicon oxide
(SiO2) due to arc energy. If silicon oxide accumulates on the
contacts, contact interference can occur. If silicon oil, silicon filling
agents, silicon cables, or other silicon products are present near the
Switch, suppress arcing with contact protective circuits (surge
killers) or remove the source of silicon gas.
Bending radius
(R45 mm min.)
Secure
here
5 cm
Connections
• Be sure to connect a fuse with a breaking current 1.5 to 2 times
larger than the rated current to the Limit Switch in series in order to
protect the Limit Switch from damage due to short-circuiting.
• When using the Limit Switch for the EN ratings, use the gI or gG 10A fuse.
13
D4C
Operation
Mounting
• Operation method, shapes of cam and dog, operating frequency,
and overtravel have a significant effect on the service life and
precision of a Limit Switch. For this reason, the dog angle must be
30° max., the surface roughness of the dog must be 6.3 S min. and
hardness must be Hv 400 to 500.
• To allow the plunger-type actuator to travel properly, adjust the dog
and cam to the proper setting positions. The proper position is
where the plunger groove fits the bushing top.
• A maximum of 6 Switches may be group-mounted. In this case, pay
attention to the mounting direction so that the convex part of the
group-mounting guide on one Switch fits into the concave part of
the guide on the other Switch as shown in the figure below. For
group mounting, the mounting panel must have a thickness (t) of
6 mm min.
Group Mounting
Mounting panel
16 mm
Group-mounting guide
(Front: convex
Rear: concave)
Dog
Bushing top
Groove
2.8 mm
Group-mounting guide
(Front: convex Rear: concave)
2.8 mm
• To allow the roller lever-type actuator to travel properly, adjust the
dog and cam so that the arrow head is positioned between the two
convex markers as shown below.
Mounting Holes
Correct
Not correct
Correct
Convex
markers
Indicator
• Indicator-equipped switch has contacts and indicator in parallel.
When contacts are open, leakage current flows through the
indicator circuit and may cause load's malfunction.
Please check the load's OFF current before use the indicatorequipped switch.
Two, 5.2-dia. or M5 screw holes
25±0.1
• Use a Switch with a rubber cap when using the plunger type in an
environment where malfunction is possible due to environmental
conditions such as dust or cutting chips which may not allow
resetting.
• Do not expose the Switch to water exceeding 70°C or use it in
steam.
• When the D4C is used in a circuit of a device to be exported to
Europe, classified as Overvoltage Class III as specified in IEC664,
provide a contact protection circuit.
• Tighten each screw to a torque according to the following table.
No.
Type
Appropriate tightening torque*
1
M5 Allen-head bolt
4.90 to 5.88 N·m
2
M3.5 head mounting screw
0.78 to 0.88 N·m
3
M5 Allen-head bolt
4.90 to 5.88 N·m
* By removing the two screws from
the head, the head direction can
be rotated 180°. After changing the
head direction, re-tighten to the
torque specified above. Be careful
not to allow any foreign substance
to enter the Switch.
Micro-load Models (D4C-4, -5, -6)
Micro-load models
can be used for
switching in the range
shown below.
Voltage (V)
Arrow head
Not correct
t
• If the mounting panel is warped or has protruding parts, a
malfunction may result. Make sure that the mounting panel is not
warped and has even surfaces.
5 mW
800 mW
0.16 mA
30
26 mA
24
Switching
range for
micro-load
models
Switching
range for
standardload
models
12
5
Switching
not possible
in this range
1 mA
100 mA 160 mA
0
0.1
1
10
100
1,000
Current (mA)
14
Read and Understand This Catalog
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or
comments.
Warranty and Limitations of Liability
WARRANTY
OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified)
from date of sale by OMRON.
OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR
FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS
DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER
WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS
IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT
LIABILITY.
In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted.
IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS
OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT
SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
Application Considerations
SUITABILITY FOR USE
OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's
application or use of the products.
At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the
products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product,
machine, system, or other application or use.
The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible
uses of the products, nor is it intended to imply that the uses listed may be suitable for the products:
Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog.
Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles,
safety equipment, and installations subject to separate industry or government regulations.
Systems, machines, and equipment that could present a risk to life or property.
Please know and observe all prohibitions of use applicable to the products.
NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE
SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND
INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM.
PROGRAMMABLE PRODUCTS
OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof.
Disclaimers
CHANGE IN SPECIFICATIONS
Product specifications and accessories may be changed at any time based on improvements and other reasons.
It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made.
However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or
establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual
specifications of purchased products.
DIMENSIONS AND WEIGHTS
Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
PERFORMANCE DATA
Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the
result of OMRON’s test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON
Warranty and Limitations of Liability.
ERRORS AND OMISSIONS
The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical,
typographical, or proofreading errors, or omissions.
2012.9
In the interest of product improvement, specifications are subject to change without notice.