0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
D4DS-K1

D4DS-K1

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    D4DS-K1

  • 数据手册
  • 价格&库存
D4DS-K1 数据手册
F502-EN2-04.book Seite 131 Dienstag, 26. Juli 2005 5:48 17 Safety-door Switch D4NS Multi-contact, Labor-saving, Environment-friendly, Next-generation Safety-door Switch • Lineup includes three contact models with 2NC/1NC and 3NC contact forms in addition to the previous contact forms 1NC/1NO, and 2NC. • M12-connector models are available, saving on labor and simplifying replacement. • Standardized gold-clad contacts provide high contact reliability. • Applicable to both standard loads and micro loads. • Free of lead, cadmium, and hexavalent chrome, reducing the burden on the environment. Model Number Structure Model Number Legend Operation Key D4NS-@@@ 1 2 3 1. Conduit/Connector size 1: Pg13.5 (1-conduit) 2: G1/2 (1-conduit) 3: 1/2-14NPT (1-conduit) 4: M20 (1-conduit) 5: Pg13.5 (2-conduit) 6: G1/2 (2-conduit) 7: 1/2-14NPT compatible (2-conduit model with M20 conduit size includes an M20-to-1/2-14NPT conversion adapter) 8: M20 (2-conduit) 9: M12 connector (1-conduit) 2. Built-in Switch A: 1NC/1NO (slow-action) B: 2NC (slow-action) C: 2NC/1NO (slow-action) D: 3NC (slow-action) E: 1NC/1NO (MBB contact) F: 2NC/1NO (MBB contact) 3. Head Mounting Direction F: Four mounting directions possible (Front-side mounting at shipping) D4DS-K@ 1 1. Operation Key Type 1: Horizontal mounting 2: Vertical mounting 3: Adjustable mounting (Horizontal) 5: Adjustable mounting (Horizontal/ Vertical) D4NS Switch Note: An order for the head part or the switch part alone cannot be accepted. The Operation Key is sold separately. D4NS G-131 F502-EN2-04.book Seite 132 Dienstag, 26. Juli 2005 5:48 17 Ordering Information List of Models Switches (Operation Keys are sold separately.) : Models with approved direct opening contacts. Type 1-conduit Contact configuration Slow-action 1NC/1NO 2NC 2NC/1NO 3NC Slow-action MBB contact 1NC/1NO 2NC/1NO 2-conduit Slow-action 1NC/1NO 2NC 2NC/1NO 3NC Slow-action MBB contact 1NC/1NO 2NC/1NO 1-conduit, with connector Slow-action Slow-action MBB contact 1NC/1NO Conduit opening/Connector Model Pg13.5 D4NS-1AF (note 3) G1/2 D4NS-2AF 1/2-14NPT D4NS-3AF M20 D4NS-4AF (note 3) Pg13.5 D4NS-1BF (note 3) G1/2 D4NS-2BF 1/2-14NPT D4NS-3BF M20 D4NS-4BF (note 3) Pg13.5 D4NS-1CF (note 3) G1/2 D4NS-2CF 1/2-14NPT D4NS-3CF M20 D4NS-4CF (note 3) Pg13.5 D4NS-1DF G1/2 D4NS-2DF 1/2-14NPT D4NS-3DF M20 D4NS-4DF (note 3) Pg13.5 D4NS-1EF G1/2 D4NS-2EF 1/2-14NPT D4NS-3EF M20 D4NS-4EF (note 3) Pg13.5 D4NS-1FF G1/2 D4NS-2FF 1/2-14NPT D4NS-3FF M20 D4NS-4FF (note 3) Pg13.5 D4NS-5AF G1/2 D4NS-6AF M20, includes M20-to-1/2-14NPT conversion adapter D4NS-7AF M20 D4NS-8AF Pg13.5 D4NS-5BF (note 3) G1/2 D4NS-6BF M20, includes M20-to-1/2-14NPT conversion adapter D4NS-7BF M20 D4NS-8BF (note 3) Pg13.5 D4NS-5CF G1/2 D4NS-6CF M20, includes M20-to-1/2-14NPT conversion adapter D4NS-7CF M20 D4NS-8CF (note 3) Pg13.5 D4NS-5DF G1/2 D4NS-6DF M20, includes M20-to-1/2-14NPT conversion adapter D4NS-7DF M20 D4NS-8DF Pg13.5 D4NS-5EF G1/2 D4NS-6EF M20, includes M20-to-1/2-14NPT conversion adapter D4NS-7EF M20 D4NS-8EF Pg13.5 D4NS-5FF G1/2 D4NS-6FF M20, includes M20-to-1/2-14NPT conversion adapter D4NS-7FF M20 D4NS-8FF M12 connector D4NS-9AF (note 3) 2NC D4NS-9BF (note 3) 1NC/1NO D4NS-9EF (note 3) Note: 1. The recommended models for equipment and machinery being exported to Europe are those with an M20 or Pg13.5 conduit sizes, and for North America, the recommended models are those with a 1/2-14NPT conduit sizes. 2. Resin is used as the material for the D4NS housing and head. Use the metal D4BS Safety-door Switch for applications requiring greater mechanical strength. 3. Prefered stock item G-132 Safety Sensors / Components F502-EN2-04.book Seite 133 Dienstag, 26. Juli 2005 5:48 17 Operation Keys Type Model Horizontal mounting D4DS-K1 Vertical mounting D4DS-K2 Adjustable mounting (Horizontal) D4DS-K3 Adjustable mounting (Horizontal/Vertical) D4DS-K5 Specifications Approved Standards Agency Standard TÜV Product Service EN60947-5-1 (approved direct opening) GS-ET-15 UL (See note.) UL508, CSA C22.2 No.14 File No. B0306 39656052 E76675 Note: Approval for CSA C22.2 No. 14 is authorized by the UL mark. Standards and EC Directives • Conforms to the following EC Directives: Machinery Directive Low Voltage Directive EN50047 EN1088 CCC (China Compulsory Certification) Mark Agency CQC Standard GB14048.5 File No. Under application Approved Standard Ratings TÜV (EN60947-5-1) Rated operating current (Ie) AC-15 3A DC-13 0.27 A Rated operating voltage (Ue) 240 V 250 V D4NS Utilization category Item Note: Use a 10-A fuse type gI or gG that conforms to IEC269 as a short-circuit protection device. This fuse is not built into the Switch. UL/CSA (UL508, CSA C22.2 No. 14) A300 Rated voltage 120 VAC 240 VAC D4NS Carry current Current Make 10 A Break 60 A 6A 30 A 3A Volt-amperes Make Break 7,200 VA 720 VA G-133 F502-EN2-04.book Seite 134 Dienstag, 26. Juli 2005 5:48 17 Characteristics Degree of protection (See note 3.) IP67 (EN60947-5-1) (This applies for the Switch only. The degree of protection for the key hole is IP00.) Durability (See note 4.) Mechanical 1,000,000 operations min. Electrical 500,000 operations min. for a resistive load of 3 A at 250 VAC (See note 5.) 300,000 operations min. for a resistive load of 10 A at 250 VAC Operating speed 0.05 to 0.5 m/s Operating frequency 30 operations/minute max. Direct opening force (See note 6.) 60 N min. Direct opening travel (See note 6.) 10 mm min. Contact resistance 25 mΩ max. Minimum applicable load (See note 7.) Resistive load of 1 mA at 5 VDC (N-level reference value) Rated insulation voltage (Ui) 300 V Protection against electric shock Class II (double insulation) Pollution degree (operating environment) 3 (EN60947-5-1) Impulse withstand voltage (EN60947-5-1) Between terminals of the same polarity 2.5 kV Between terminals of different polarities 4 kV Between other terminals and uncharged metallic parts 6 kV Insulation resistance 100 MΩ min. Contact gap 2 x 2 mm min Vibration resistance Malfunction 10 to 55 Hz, 0.75-mm single amplitude Shock resistance Destruction 1,000 m/s2 min. Malfunction 300 m/s2 min. Conditional short-circuit current 100 A (EN60947-5-1) Rated open thermal current (Ith) 10 A (EN60947-5-1) Ambient temperature Operating: -30° C to 70° C with no icing Ambient humidity Operating: 95% max. Weight Approx. 96 g (D4NS-1CF) Note: 1. The above values are initial values. 2. Once a contact has been used to switch a standard load, it cannot be used for a load of a smaller capacity. Doing so may result in roughening of the contact surface and contact reliability may be lost. 3. The degree of protection is tested using the method specified by the standard (EN60947-5-1). Confirm that sealing properties are sufficient for the operating conditions and environment beforehand. Although the switch box is protected from dust or water penetration, do not use the D4NS in places where foreign material may penetrate through the key hole on the head, otherwise Switch damage or malfunctioning may occur. 4. The durability is for an ambient temperature of 5° C to 35° C and an ambient humidity of 40% to 70%. For more details, consult your OMRON representative. 5. If the ambient temperature is greater than 35° C, do not pass the 3-A, 250-VAC load through more than 2 circuits. 6. These figures are minimum requirements for safe operation. 7. This value will vary with the switching frequency, environment, and reliability level. Confirm that correct operation is possible with the actual load beforehand. G-134 Safety Sensors / Components F502-EN2-04.book Seite 135 Dienstag, 26. Juli 2005 5:48 17 Nomenclature Structure D4NS-@A@, D4NS-@B@, D4NS-@E@ D4NS-@C@, D4NS-@D@, D4NS-@F@ Operation key hole Head The head can be mounted in four directions. Sealing properties The switch casing ensures IP67 (except the keyhole, which ensures IP00). Use the D4NS in places where the keyhole is free from oil, water, and metal chips. Terminal 11 Terminal 12 Terminal 31 (33) Terminal 32 (34) Terminal 11 Terminal 12 Terminal 21 Terminal 22 Terminal 31 (33) Terminal 32 (34) Note: The 2-conduit models have the same terminal arrangement. Contact Form (Diagrams Show State with Key Inserted) Contact 1NC/1NO Contact form 11 12 33 34 Operating pattern 11-12 33-34 ON Stroke Extraction completion position Operation Key insertion completion position D4NS-@B@ 2NC 11 12 31 32 11-12 31-32 D4NS-@D@ 2NC/1NO 3NC 11 12 Stroke 21 22 33 34 11 12 21 22 31 32 ON Stroke Extraction completion position Operation Key insertion completion position 11-12 21-22 31-32 ON Stroke Operation Key insertion completion position D4NS-@E@ 1NC/1NO MBB 11 12 33 34 2NC/1NO MBB 11 12 ON Stroke 21 22 33 34 Extraction completion position 11-12 21-22 33-34 Extraction completion position Only NC contacts 11-12 and 21-22 have an approved direct opening mechanism. The terminals 11-12, 21-22, and 33-34 can be used as unlike poles. Only NC contacts 11-12, 21-22, and 31-32 have an approved direct opening mechanism. Only NC contacts 11-12 have an approved direct opening mechanism. The terminals 11-12 and 33-34 can be used as unlike poles. ON Stroke Operation Key insertion completion position Only NC contacts 11-12 and 31-32 have an approved direct opening mechanism. The terminals 11-12 and 31-32 can be used as unlike poles. The terminals 11-12, 21-22, and 31-32 can be used as unlike poles. Extraction completion position 11-12 33-34 Operation Key insertion completion position D4NS-@F@ Extraction completion position 11-12 21-22 33-34 Only NC contacts 11-12 have an approved direct opening mechanism. The terminals 11-12 and 33-34 can be used as unlike poles. ON Operation Key insertion completion position D4NS-@C@ Remarks Only NC contacts 11-12 and 21-22 have an approved direct opening mechanism. The terminals 11-12, 21-22 and 33-34 can be used as unlike poles. Note: MBB (Make Before Break) contacts have an overlapping structure, so that before the normally closed contact (NC) opens, the normally open contact (NO) closes. D4NS G-135 D4NS Model D4NS-@A@ F502-EN2-04.book Seite 136 Dienstag, 26. Juli 2005 5:48 17 Dimensions/Operating Characteristics Note: All units are in millimeters unless otherwise indicated. Switches 1-conduit Models Head cap D4NS-1@F D4NS-2@F D4NS-3@F D4NS-4@F 7.5 30.6 15.5 30.2 15.3 Red 4.4 Operating characteristics D4NS-1@F D4NS-2@F D4NS-3@F D4NS-4@F Key insertion force Key extraction force 15 N max. 30 N max. 41 33.5 Pretravel (PT) 6±3 mm Total travel (TT) (28 mm) 2.5 Black 55 47±0.2 21.5 20±0.1 22±0.1 31.5 2.15±0.05R mounting holes 4+0.15 0 Two, depth: 5 dia. holes Direct opening force* Direct opening stroke* 60 N min. 10 mm min. * Always maintain the above operating characteristics for safe use. 14.2 30 22±0.2 31 2-conduit Models Head cap D4NS-5@F D4NS-6@F D4NS-7@F D4NS-8@F 7.5 31.5 30.6 42±0.1 40±0.1 30.2 15.3 Red 21.5 41 47 33.5 5.4 2.5 Key insertion force Key extraction force 15 N max. 30 N max. 9±0.2 Pretravel (PT) 6±3 mm Total travel (TT) (28 mm) 20.5 20±0.1 39±0.2 D4NS-5@F D4NS-6@F D4NS-7@F D4NS-8@F 15.5 4.4 Black Operating characteristics 25 dia. 22±0.1 Cap 42±0.2 56 max. 2.15±0.05R mounting holes 14.2 3 30 Two, 4+0.15 dia. holes 0 depth: 5 Direct opening force* Direct opening stroke* 60 N min. 10 mm min. * Always maintain the above operating characteristics for safe use. 1-conduit Connector Models Head cap D4NS-9@F 7.5 Red 30.6 15.5 30.2 15.3 4.4 Black Operating characteristics D4NS-9@F Key insertion force Key extraction force 15 N max. 30 N max. 41 33.5 Pretravel (PT) 6±3 mm Total travel (TT) (28 mm) 2.5 55 47±0.2 21.5 20±0.1 22±0.1 31.5 2.15±0.05R mounting holes Two, 4+0.15 dia. holes 0 depth: 5 Direct opening force* Direct opening stroke* 60 N min. 10 mm min. * Always maintain the above operating characteristics for safe use. (14) 22±0.2 31 M12 × 1 14.2 30 Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. G-136 Safety Sensors / Components F502-EN2-04.book Seite 137 Dienstag, 26. Juli 2005 5:48 17 Operation Keys Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. D4DS-K1 17.5 28 15 4 4.3 7 30 14 D4DS-K3 28 13 15 4.5 dia. 10.5 9 D4DS-K5 6 28 30 20.9 7 13 28 15° 43 7 30 55 8 dia. 24.6 22.5 4 15 2 4.3 56 9 dia. 2 6.3 D4DS-K2 40 20 Black Four, 2.15R 7 30 13 13 41 13 Four, 2.15R 18° Black 6.5 18 (7) With Operation Key Inserted (Relationship between Insertion Radius and Insertion Hole) Note: Unless otherwise specified, a tolerance of ±0.4 mm applies to all dimensions. D4NS-1@F + D4DS-K1 D4NS-1@F + D4DS-K2 44 to 46.5 Key insertion face 40 to 42.5 Key insertion face Red Horizontal key insertion radius R ≥ 200 (30.6) (15) Black (30.6) (15) Black Permissible difference in center lines between the Operation Key and key hole is ±1. Vertical key insertion radius R ≥ 200 (30.6) 44 to 46.5 Key insertion face (30.6) Vertical key insertion radius R ≥ 200 (33.5) (27.5) Permissible difference in center lines between the Operation Key and key hole is ±1. Permissible difference in center lines between the Operation Key and key hole is ±1. D4NS-1@F + D4DS-K3 D4NS-1@F + D4DS-K5 45 to 47.5 Key insertion face (30.6) Horizontal key insertion radius R ≥ 50 (40±0.15) Black Permissible difference in center lines between the Operation Key and key hole is ±1. (30.6) 45 to 47.5 Key insertion face Vertical key insertion radius R ≥ 200 (33.5) Permissible difference in center lines between the Operation Key and key hole is ±1. D4NS Permissible difference in center lines between the Operation Key and key hole is ±1. 40 to 42.5 Key insertion face (33.5) Red Horizontal key insertion radius R ≥ 200 Red 51.9 to 54.4 Key insertion face (30.6) (43±0.1) (41±0.1) Black Horizontal key insertion radius R ≥ 50 (30.6) 51.9 to 54.4 Key insertion face Permissible difference in center lines between the Operation Key and key hole is ±1. Vertical key insertion radius R ≥ 50 (33.5) Permissible difference in center lines between the Operation Key and key hole is ±1. G-137 D4NS Red F502-EN2-04.book Seite 138 Dienstag, 26. Juli 2005 5:48 17 Safety Precautions Refer to OMRON SAFETY COMPONENTS SERIES (Y106) for common precautions. CAUTION Do not dismount the operation key from the door intentionally and insert it to the switch with the door open. Machine may start operating and injury or death may be caused. 2. Mounting method • Mounting Screw Tightening Torque Loose mounting may result in malfunction. Fasten the screws to the specified torque. Terminal screw 0.6 to 0.8 N·m Cover clamping screw 0.5 to 0.7 N·m Do not use metal connector or conduit with this switch. The broken conduit hole may cause electrical shock hazard. Head clamping screw 0.5 to 0.6 N·m Operation Key clamping screw (See item 4) 2.4 to 2.8 N·m Precautions for Safe Use Body clamping screw (See item 4) 0.5 to 0.7 N·m Conduit mounting connection (see item 10,11), M12 changing adaptor 1.8 to 2.2 N·m Cap screw 1.3 to 1.7 N·m • Be careful not to drop your D4NS, or the switch will not fully exhibit its ability. • Do not disassemble or remodel your D4NS in any case, or the D4NS will not operate normally. • Do not use the switch where explosive gas, ignitable gas, or any other harmful gasses may be present. • Install operation key so that it will not hit the operator when the door is open. Injury may be caused. • Do not use the switch in the oil and in the water. IP67(EN60947-5-1) • Though the switch body is protected from the ingress of dust or water, avoid the ingress of foreign substance through the key hole on the head. Otherwise, wear in short time or break may be caused • Do not put the electric power when wiring. • Be sure to install a cover after the wiring. Do not put the electric power when opening a cover. • Connect the fuse to the switch in series to prevent it from short circuit damage. The value of the breaking current of the fuse must be increased to cover the rated current by 150 to 200%. When using the switch with EN rating, use 10 A fuse, type gI or gG that complies with IEC 60269. • Keep the electrical load below the rated value. • On the switching of general loads (250VAC/3A), do not operate two circuits or more at the same time. Otherwise, insulation performance may be degraded. • The durability of the switch is seriously affected by operating conditions. Evaluate the switch under actual working conditions before permanent installation. • Please mention in machine manufacturer's Instruction. Manual that the user must not repair nor maintain the switch and must contact machine manufacturer for them. • Do not use the switch as a stopper. Be sure to install a stopper as shown in the following illustration to prevent the edge of the operation key from inadvertently hitting the switch directly. Stopper 1.4 to 1.8 N·m (1/2-14NPT) • Switch, operation key • The switch and operation key will be fastened to specified torque in item 2 with M4 screws and washers. • Secured more by the studs like below picture 4-0.05/-0.15 dia., 4.8 max. height at the lower two which are inserted from back side of switch. (Operation key mounting hole) (Switch mounting holes) (1 conduit type) D4DS-K1/-K2 Two, M4 Two, M4 2.5 20 ±0.1 22±0.1 15 ±0.1 47±0.1 D4DS-K3 Two, M4 40 ±0.1 22±0.1 −0.05 4 −0.15 dia. height, 4.8 max. D4DS-K5 Two, M4 (2 conduits type) Two, M4 41±0.1 or, 43±0.1 2.5±0.1 5.35±0.1 39±0.1 20±0.1 22±0.1 40±0.1 42±0.1 42±0.1 4−0.05 −0.15 dia. height, 4.8 max. • Do not use the operation key other than dedicated OMRON's. Otherwise switch may be damaged. • Be sure that the operation key can be inserted properly to key hole with a tolerance of ± 1 mm. 3. Head direction The rotation of the switch head may be adjusted to any of the four directions by loosening the head clamping screws at the four corners of the head. 4. Securing of the door Operation Key Switch Precautions for Correct Use 1. Environment • The switch is intended for indoor use only. • Do not use your D4NS outdoor, or the switch will malfunction. • Do not use your D4NS in the atmosphere of hazardous gases (H2S, SO2, NH3, HNO3, CI2, etc.) or high temperature and humidity, or it will cause the imperfect closing of the contacts or the breakage thereof stemming from corrosion. • Do not use the switch under any of the conditions mentioned below. • Frequent temperature range. • High humidity or dew condensation may be generated. • Where the switch is subject to severe vibration. • Where the metal dust, oil, or chemical is sprayed inside the door. If the operation key is pulled in the opening direction due to a force caused by vibration, by the door weight, or by a cushion attached to the door. The closed door must be secured with a hook or by similar means. Set zone (0.5 to 3 mm) Operation Key 5. Wiring • When connect with insulation tubes and terminals, connect the terminals as shown in the following figure and wire without overriding to the case and the cover. Adequate conductor size is AWG 20 to 18 (0.5 to 0.75 mm2). Wire leads as shown in the following figure. Otherwise, the switch cover does not fit. • Where thinner is applied. G-138 Safety Sensors / Components F502-EN2-04.book Seite 139 Dienstag, 26. Juli 2005 5:48 17 8. Conduit opening (1 conduit type) AB A B 11 12 21 22 D E 33 34 F Use the connectors recommended in clause 9 and tighten the connector with specified torque in clause 2. An excessive torque will bring a case breakage. D C F E C 42 mm 33 mm 28 mm Apply sealing tape between connector and conduit opening so that the enclosure will conform to IP67. Tolerance ±2 mm Use a cable with a suitable diameter for the connector. (2 conduits type) ECA B 11 12 Left hand 9. Recommendation of connector ECA BD F C D 21 22 42 mm E For unused conduit opening, apply a conduit cap provided and tighten it to specified torque in clause 2. BD F Right hand 42 mm 28 mm F 33 34 28 mm Tolerance ±2 mm Tolerance ±2 mm • Do not push the ring connector and the likes into the opening between the parts in order to prevent the case from being broken and deformed. • Use terminals having the thickness of 0.5 mm or less to avoid the contact between the terminal and the switch case inside. The below listed the terminals have thickness of 0.5 mm or less. Manufacture Type J.S.T. Wire size FV0.5-3.7 (F type) AWG22 to 20 V0.5-3.7 (straight type) Use the connector with thread section of 9 mm long or less. In the case of the connector with longer thread section, protruded part may interfere with the other parts inside the body. Use below listed connector to secure IP67. Size G1/2 Manufacture LAPP Ohm Denki Type ST-PF1/2 5380-1002 OA-W1609 7.0 to 9.0 mm OA-W1611 9.0 to 11.0 mm LAPP S-13.5 5301-5030 6.0 to 12.0 mm M20 LAPP ST-M20 × 1.5 5311-1020 7.0 to 13.0 mm 1/2-14NPT LAPP ST-NPT1/2 5301-6030 6.0 to 12.0 mm M12 LAPP ST-M12 × 1.5 5301-1000 3.5 to 7.0 mm HEYCO Terminal screw t: dz dia.: D dia.: B: L: F: I: l 0.5 mm 3.7 mm 2.9 mm 6.6 mm 19 mm D 7.7 mm 8.0 mm F Crimp terminal Incorrect dz HEYCO is an American manufacturer. • The following show a safety contact and an auxiliary contact for 3 contacts and 2 contacts types. (Screw terminal type) D4NS-@CF (2NC/1NO) D4NS-@FF (2NC/1NO (MBB)) 11 12 11 12 21 22 21 22 31 32 33 34 D4NS-@BF (2NC) D4NS-@AF (1NC/1NO) D4NS-@FF (1NC/1NO (MBB)) 11 12 11 12 31 32 33 34 D4NS-9BF (2NC) (Connector type) 1 2 4 3 LAPP is a German manufacturer. Ohm Denki is a Japanese manufacturer. 6. Contact arrangement D4NS-@DF (3NC) 4.3 to 11.9 mm When use LAPP's products, use together with a seal packing which is sold separately (Type names, JPK-16, GP-13.5, GPM20. GPM12 is for M12 connector) and tighten with proper tightening torque. B Correct 6.0 to 12.0 mm Pg13.5 J.S.T is a Japanese manufacturer. L Adequate cable Diameter 1 (11) 2 (12) 3 (31) 4 (32) D4NS-9AF (1NC/1NO) D4NS-9EF (1NC/1NO (MBB)) 1 (11) 2 (12) 3 (33) 4 (34) Pin No. (Terminal No.) Suitable socket is Type XS2F (OMRON). Before using the 2 conduit type 1/2-14NPT connector, attach the appended changing adapter to the switch, and wind the seal tape about the joint of the adapter and switch. When use M12 conduit type, connect the above listed connector, after tightened the M12 changing adaptor to the switch. The M12 changing adaptor is enclosed with the packing. 10. Storage Do not keep the switch in dusty, humid place and any place where gas may be present for example H2S, SO2, NH3, HNO3, Cl2. 11. Others • Do not impose excessive force on the key top while the operation key is inserted into the switch body or drop the switch with the operation key inserted to avoid the deformation of the key or the breakage of the switch body. • Confirm that the seal rubber has no abnormality and then use it. If the seal rubber is displaced or floated, or if foreign matters adhere to the seal rubber, the seal rubber will lose its sealing capability. • Do not use any screw other than correct one, or the sealing capability of the seal rubber will deteriorate. • Please do a regular check in premeditation for this switch. 7. Socket tightening (connector type) Do not use any tools, such as pliers, otherwise the socket connector may become damaged. Connect the socket connector to the connector threads of the D4NS. Then firmly turn the socket connector by hand so that the connector threaded portion will be completely covered by the socket connector so that space will be almost 0. Make sure, however, that the socket connector is tightened securely, otherwise the rated degree of protection of the D4NS may not be maintained. Furthermore, the socket connector may be loosened by vibration. D4NS G-139 D4NS A F502-EN2-04.book Seite 140 Dienstag, 26. Juli 2005 5:48 17 Production Termination Following the release of the D4NS, production of the D4DS will be terminated. Date of Production Termination List of Recommended Substitute Products Switch Production of the D4DS Series will be terminated in July 2006. Date of Substitute Product Release D4DS product Recommended substitute product D4DS-15FS D4NS-1AF D4DS-25FS D4NS-2AF D4DS-35FS D4NS-3AF Product Replacement D4DS-55FS D4NS-5AF 1. Dimensions The D4DS and D4NS have basically the same structure, and use the same mounting method, Operation Keys, mounting hole and Operation Key insertion positions. The multi-contact structure and the extra 4 mm in length, however, are different. 2. Terminal Numbers For the 2-contact model, the terminals 21, 22, 23, and 24 on the D4DS are 31, 32, 33, and 34 on the D4NS. 3. Recommended Terminals If the recommended terminals are not used, the Switch may not be compatible. Make sure that the Switch is compatible with the terminals. D4DS-65FS D4NS-6AF D4DS-1AFS D4NS-1BF D4DS-2AFS D4NS-2BF D4DS-3AFS D4NS-3BF D4DS-5AFS D4NS-5BF D4DS-6AFS D4NS-6BF Sale of the D4NS Series commenced in July 2003. Comparison of the D4DS and Substitute Products Model D4NS-@ Switch color Very similar Dimensions Very similar Wiring/connection Significantly different Mounting method Very similar Ratings/performance Very similar Operating characteristics Operation Key • • • • D4DS-K1 D4DS-K2 D4DS-K3 D4DS-K5 All of the above Operation Keys can be used with the D4NS. Very similar Operating method Completely compatible Dimensions (Unit: mm) Discontinued Models (1-conduit D4DS) Replacement products (1-conduit D4NS) Head cap 7.5 30 × 30 30.6 15.5 30.2 15.3 4.4 41 33.5 Two, 4+0.15 dia. holes 0 depth: 5 2.15±0.05R mounting holes 2.5 55 47±0.2 21.5 20±0.1 22±0.1 31.5 2.15±0.05R mounting holes 14.2 30 22±0.2 31 Discontinued Model (2-conduit D4DS) Replacement products (2-conduit D4NS) Head cap 15.3 4.4 7.5 7.5 31.5 30.5 21.5 42±0.1 40±0.1 30 × 30 4.4 41 33.5 5.4 21.5 15.5 4.4 2.5 9±0.2 41 19 33.5 5.4 2.5 9±0.2 25 dia. 22±0.1 42±0.2 50 56 max. Cap 2.15±0.05R mounting holes 14.2 30 3 47 39±0.2 20±0.1 22±0.1 20.5 25 dia. Cap Two, 4+0.15 dia. holes 0 depth: 5 42±0.2 56 max. G-140 31.5 30.6 42±0.1 40±0.1 30.2 15.3 15.5 15.3 ±0.2 20±0.1 43 39 Two, 4+0.15 dia. holes 0 depth: 5 2.15±0.05R mounting holes 3 14.2 30 Two, 4+0.15 dia. holes 0 depth: 5 Safety Sensors / Components F502-EN2-04.book Seite 141 Dienstag, 26. Juli 2005 5:48 17 !WARNING This catalog is a guide to help customers select the proper safety product. Observe the following items when choosing products, select the right product for your device or equipment, and develop a safety-related system to fully utilize the product's functions. Setting up a risk assessment system The items listed in this catalog must be used properly in terms of product location as well as product performance and functionality. Part of the process of selecting and using these products should include the introduction and development of a risk assessment system early in the design development stage to help identify potential dangers in your equipment that will optimize safety product selection. A badly designed risk assessment system often results in poor choices when it comes to safety products. • Related international standard: ISO 14121 "Principles of risk assessment." Safety policy When developing a safety system for the devices and equipment that use safety products, make every effort to understand and conform to the entire series of international and industrial standards available, such as the examples given below. • Related international standards: ISO/DIS 12100 "Basic concepts, general principles for design" IEC 61508 "Functional safety of electrical/electronic/programmable electronic safety-related systems." Role of safety products Safety products have functions and mechanisms that ensure safety as defined by standards. These functions and mechanisms are designed to attain their full potential within safety-related systems. Make sure you fully understand all functions and mechanisms, and use that understanding to develop systems that will ensure optimal usage. • Related international standard: ISO 14119 "Interlocking devices associated with guards- Principles for design and selection." Installing safety products Make sure that properly educated and trained engineers are selected to develop your safety-related system and to install safety products in devices and equipment. • Related international standards: ISO/DIS 12100 "Basic Concepts, general principles for design." IEC 61508 "Functional safety of electrical/electronic/programmable electronic safety-related systems." Observing laws and regulations Safety products should conform to pertinent laws, regulations and standards, but make sure that they are used in accordance with the laws, regulations and standards of the country where the devices and equipment incorporating these products are distributed. • Related international standard: IEC 60204 "Electrical equipment of machines." Observing usage precautions Carefully read the specifications and precautions listed in this catalog for your product as well as all items in the Operating Manual packed with the product to learn usage procedures that will optimize your choice. Any deviation from precautions will lead to unexpected device or equipment failure not anticipated by safety-related systems or fire originating from equipment failure. Transferring devices and equipment When transferring devices and equipment, be sure to keep one copy of the Operating Manual and pack another copy with the device or equipment so the person receiving it will have no problem operating it. D4NS • Related international standards: ISO/DIS 12100 "Basic concepts, general principles for design" IEC 61508 "Functional safety of electrical/electronic/programmable electronic safety-related systems." D4NS G-141 F502-EN2-04.book Seite 142 Dienstag, 26. Juli 2005 5:48 17 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. C128-E2-03-X G-142 In the interest of product improvement, specifications are subject to change without notice. Safety Sensors / Components
D4DS-K1 价格&库存

很抱歉,暂时无法提供与“D4DS-K1”相匹配的价格&库存,您可以联系我们找货

免费人工找货
D4DS-K1
    •  国内价格
    • 1+13.99730

    库存:10