Motor Protection Circuit Breaker J7MN ) MPCB system • Rotary and switch types • Rated operational current 32 A, 63 A and 100 A • Switching capacity up to 100 kA/400 V • Fixed short-circuit release = 13 x Iu • Overload release adjustable 0.65 - 1 x Iu • Motor protection CLASS 10 • Fulfill all needed standards Options • ON/OFF indication • Trip alarm/indication • Undervoltage release • Shunt release • Three phase busbar system • Moulded plastic enclosures • Door coupling rotary mechanisms • Insulated Link modules Ordering Information ■ Model Number Legend 1. Motor Protection Circuit Breaker 1) Motor Protection Circuit Breaker J7MN-##-### 1 2 3 2) Type/range 3) Setting range 2. Options for MPCB J77MN-##-### 1 2 3 1) 2) 3) Options MPCB Auxiliary contacts T: Trip indicator U: Undervoltage release S: Shuntrelease DC: Door-coupling HU: DIN-rail adaptors V: Link modules PF: Enclosure Other specifications 3. Busbars, line side terminals and shrouds 1) Options MPCB J75-###-### 1 2 3 2) CPM: Busbars BTC: Line side TA: Shrouds 3) Other specifications Motor Protection Circuit Breaker J7MN 1 ■ System overview Motor Protection Circuit Breaker Rated Current In Suitable for motors 3~400 V A J7MN-3P J7MN-3R J7MN-6R J7MN-9R 2 Setting range Thermal Overload Release Instantaneous Short Circuit Release Type kW A 0.16 - 0.10 - 0.16 2.1 100 J7MN-3P-E16 0.25 0.06 0.16 - 0.25 3.3 100 J7MN-3P-E25 0.4 0.09 0.25 - 0.4 5.2 100 J7MN-3P-E4 0.63 0.18 0.4 0.63 8.2 100 J7MN-3P-E63 1 0.25 0.63 - 1 13 100 J7MN-3P-1 1.6 0.55 1 - 1.6 20.8 100 J7MN-3P-1E6 2.5 0.75 1.6 - 2.5 32.5 100 J7MN-3P-2E5 4 1.5 2.5 - 4 52 100 J7MN-3P-4 6 2.2 4 - 6 78 100 J7MN-3P-6 8 3 5 - 8 104 100 J7MN-3P-8 10 4 6 - 10 130 50 J7MN-3P-10 13 5.5 9 - 13 169 50 J7MN-3P-13 17 7.5 11 - 17 221 20 J7MN-3P-17 22 7.5 14 - 22 286 15 J7MN-3P-22 - A Short Circuit Breaking Capacity at 3~400 V kA (Icu) 26 11 18 - 26 338 15 J7MN-3P-26 32 15 22 - 32 416 15 J7MN-3P-32 0.16 - 0.10 - 0.16 2.1 100 J7MN-3R-E16 0.25 0.06 0.16 - 0.25 3.3 100 J7MN-3R-E25 0.4 0.09 0.25 - 0.4 5.2 100 J7MN-3R-E4 0.63 0.18 0.4 0.63 8.2 100 J7MN-3R-E63 1 0.25 0.63 - 1 13 100 J7MN-3R-1 1.6 0.55 1 - 1.6 20.8 100 J7MN-3R-1E6 2.5 0.75 1.6 - 2.5 32.5 100 J7MN-3R-2E5 4 1.5 2.5 - 4 52 100 J7MN-3R-4 6 2.2 4 - 6 78 100 J7MN-3R-6 8 3 5 - 8 104 100 J7MN-3R-8 10 4 6 - 10 130 100 J7MN-3R-10 13 5.5 9 - 13 169 100 J7MN-3R-13 17 7.5 11 - 17 221 50 J7MN-3R-17 22 7.5 14 - 22 286 50 J7MN-3R-22 - 26 11 18 - 26 338 50 J7MN-3R-26 32 15 22 - 32 416 50 J7MN-3R-32 26 12.5 18 - 26 338 50 J7MN-6R-26 32 15 22 - 32 416 50 J7MN-6R-32 40 18.5 28 - 40 520 50 J7MN-6R-40 50 22 34 - 50 650 50 J7MN-6R-50 63 30 45 - 63 819 50 J7MN-6R-63 63 30 45 - 63 819 50 J7MN-9R-63 75 37 55 - 75 975 50 J7MN-9R-75 90 45 70 - 90 1170 50 J7MN-9R-90 100 - 80 - 100 1300 50 J7MN-9R-100 Motor Protection Circuit Breaker J7MN Accessories Description Mounting Max. per Contacts place MPCB Rated Operating Current AC15 24 V NO Transverse Auxiliary Side Auxiliary Any Trip Alarm Short circuit Trip Alarm Undervoltage Release Shunt Release Contact block Contact block Front Left hand side 1 1 NC AC1 240 V A 240 V A A 1 1 3 2 5 J77MN-11F 2 - 3 2 5 J77MN-20F - 2 3 2 5 J77MN-02F 1 1 6 4 10 J77MN-11S 2 - 6 4 10 J77MN-20S - 2 6 4 10 J77MN-02S Signalling switch suitable for J7MN-3 Left hand side 1 1 1 6 4 10 J77MN-TA-11S Signalling switch suitable for J7MN-6 & J7MN-9 Left hand side 1 1 1 6 4 10 J77MN-TB-11S Signalling switch Left hand side 1 1 1 6 4 10 J77MN-T-11S Description Mounting Max. per Rated voltages place MPCB Type Trips the circuit-breaker when Right hand 1 the voltage is interrupted. Pre- side vents the motor from being restarted accidentally when the voltage is restored, suitable for EMERGENCY STOP acc. to VDE 0113 24 V 50 Hz, 28 V 60 Hz J77MN-U-24 110 - 127 V 50 Hz, 120 V 60 Hz J77MN-U-110 220 - 230 V 50 Hz, 240 - 260 V 60 Hz J77MN-U-230 240 V 50 Hz, 277 V 60 Hz J77MN-U-240 380 - 400 V 50 Hz, 440 - 460 V 60 Hz J77MN-U-400 415 - 440 V 50 Hz, 460 - 480 V 60 Hz J77MN-U-415 Trips the circuit-breaker when the release coil energized. 24 V 50 Hz, 28 V 60 Hz J77MN-S-24 110 - 127 V 50 Hz, 120 V 60 Hz J77MN-S-110 220 - 230 V 50 Hz, 240 - 260 V 60 Hz J77MN-S-230 240 V 50 Hz, 277 V 60 Hz J77MN-S-240 380 - 400 V 50 Hz, 440 - 460 V 60 Hz J77MN-S-400 415 - 440 V 50 Hz, 460 - 480 V 60 Hz J77MN-S-415 Right hand 1 side Description Enclosure Type Type Plastic enclose with rotary operating mechanism, lockable space for aux. contact + release, IP65 J77MN-PF-3R Enclose with rotary operating mechanism yellow - red, lock space for aux. contact + release, IP65 J77MN-PFC-3R Motor Protection Circuit Breaker J7MN 3 Description Door-coupling rotary mechanism IP65; black/grey The door locking device prevents accidental opening of the cubicle door in the ON position of the circuit-breaker. The OFF position can be locked with up to 3 padlocks Applicable MPCBs J7MN-3R J7MN-6R J7MN-9R Door-coupling rotary mechanism IP65; red/yellow J7MN-3R J7MN-6R J7MN-9R Link modules Shaft length Type 115 mm J77MN-DC-3R-115-B 315 mm J77MN-DC-3R-315-B 115 mm J77MN-DC-6R-115-B 315 mm J77MN-DC-6R-315-B 115 mm J77MN-DC-9R-115-B 315 mm J77MN-DC-9R-315-B 115 mm J77MN-DC-3R-115-RY 315 mm J77MN-DC-3R-315-RY 115 mm J77MN-DC-6R-115-RY 315 mm J77MN-DC-6R-315-RY 115 mm J77MN-DC-9R-115-RY 315 mm J77MN-DC-9R-315-RY Description Type Mechanical and electrical connection between Mini Motor Contactor J7KNA Motor Protection Circuit Breaker and Contactor. Motor Contactor J7KN Up-to max. 32 A. Motor Contactor J7KNG J77MN-VKA-3 Electrical connection between Motor Protection Up-to 32 A Circuit Breaker and Contactor. Up-to 63 A J77MN-VD-3 J77MN-VKN-3 J77MN-VKG-3 J77MN-VD-6 J77MN-VDG-6 Up-to 100 A DIN-rail adaptors For J7MN-3 and J7KN(G)-10 up-to For mechanical fixing of circuit-breaker and contactor. With two moveable DIN-rail clips for J7KN(G)-40 easy mounting & replacing. Can be connected to one 35W x 15H mm DIN-rail or two 35W x 7.5H mm DIN-rails. J77MN-VD-9 J77MN-HU-3 For J7MN-6 and J7KN(G)-24 up-to J77MN-HU-6 For mechanical fixing of circuit-breaker and contactor. Can be connected to one 35W x 15H J7KNG-40 and/or J7KN-62 mm DIN-rail or two 35W x 7.5H mm DIN-rails. For J7MN-9 and J7KN-50 up-to J7KN- J77MN-HU-9 74 Scale cover sealable for covering the current setting scale (1 bag with 10 units) J77MN-K Push-in lugs for screwing the circuit-breaker onto mounting plates. 2 units required (1 bag with 20 units) J77MN-L Insulation barriers Up to 600 V acc.UL 489 for increased distances and clearances acc. to UL Type "E“ 4 pcs per device (2 pcs on each side) (pack 2 units) J77MN-TB100 4 Motor Protection Circuit Breaker J7MN Insulated 3-Phase Busbar System IP20 Description Connection type 3-phase busbars; modular spacing = 45 mm Spade Version Type J77MN-CPM-3-45-2S 1 J77MN-CPM-3-45-3S for 4 units 1 J77MN-CPM-3-45-4S for 5 units 1 J77MN-CPM-3-45-5S Spade Line side terminal 3-pole, connection from above; conductor cross-section solid or stranded 6-25 mm² with end sleeve 4-16 mm² acc. IEC/EN 60947-1, J7MN-3P; 60947-2, 60947-4-1 J7MN-3R and VDE 0660 1 J77MN-BTC-63-SE Spade Line side terminal 3-pole, connection from above; conductor cross-section solid or stranded 6-25 mm² with end sleeve 4-16 mm² up to 600V acc. UL 489 J7MN-3P; J7MN-3R 1 J77MN-BTC-63-SEV J7MN-3P; J7MN-3R 1 J77MN-TA-63S J7MN-3P; J7MN-3R 1 J77MN-CPM-3-45-2 1 J77MN-CPM-3-45-3 for 4 units 1 J77MN-CPM-3-45-4 for 5 units 1 J77MN-CPM-3-45-5 1 J77MN-CPM-3-54-2 1 J77MN-CPM-3-54-3 for 4 units 1 J77MN-CPM-3-54-4 for 5 units 1 J77MN-CPM-3-54-5 Pin Line side terminal 3-pole, connection from above; conductor cross-section solid or stranded 6-25 mm² with end sleeve 4-16 mm² acc. IEC/EN 60947-1, J7MN-3P; 60947-2, 60947-4-1 J7MN-3R and VDE 0660 1 J77MN-BTC-63-E Pin Line side terminal 3-pole, connection from above; conductor cross-section solid or stranded 6-25 mm² with end sleeve 4-16 mm² up to 600V acc. UL 489 J7MN-3P; J7MN-3R 1 J77MN-BTC-63-EV J7MN-3P; J7MN-3R 1 J77MN-TA-63 J7MN-6P; J7MN-6R 1 J77MN-CPM-6-55-2 for 3 units Shrouds for unused terminals on busbar system Spade 3-phase busbars; modular spacing = 45 mm Pin for 2 units for 3 units Pin for 2 units for 3 units Shrouds for unused terminals on busbar system Pin 3-phase busbars; modular spacing = 55 mm Pin for 2 units J7MN-3P; J7MN-3R Pack pcs 1 3-phase busbars; modular spacing = 54 mm for 2 units For Units (MPCB) J7MN-3P; J7MN-3R Motor Protection Circuit Breaker J7MN 5 ■ Components for Fuseless Load Feeders, DIN-rail Mounting Type of coordination „1“ 3 × 415 V 10 kA (other conditions on request) Motor Contactor Link-module DIN-rail adaptor Circuit-breaker 3~400 V up to …KW Range Model Model Range J7KNA-09 J77MN-VKA Not needed J7MN-3P / J7MN-3R J7KN-10D J77MN-VKN-3 J7KNG-10-xx D J77MN-VKG-3 J7KNA-12 J77MN-VKA Not needed J7MN-3P / J7MN-3R J7KN-14D J77MN-VKN-3 J7KNG-14-xx D J77MN-VKG-3 Not Needed J7MN-3P / J7MN-3R Not Needed J7MN-3P / J7MN-3R 4 5.5 7.5 11 15 J77MN-VKN-3 J7KNG-18-xx D J77MN-VKG-3 J7KN-22D J77MN-VKN-3 J7KNG-22-xx D J77MN-VKG-3 J7KN(G)-24 J77MN-VD-3 J77MN-HU-3 J7KN-24 J77MN-VD-6 J77MN-HU-6 J7KNG-24 J77MN-VDG-6 J7MN-6R J7KN(G)-32 J77MN-VD-3 J77MN-HU-3 J7MN-3P / J7MN-3R J7KN-32 J77MN-VD-6 J77MN-HU-6 J7MN-6R J7KNG-32 J77MN-VDG-6 J7KN-40 J77MN-VD-6 J77MN-HU-6 J7MN-6R J7KNG-40 J77MN-VDG-6 22 J7KN-50 J77MN-VD-6 J77MN-HU-6 J7MN-6R 30 J7KN-62 J77MN-VD-6 J77MN-HU-6 J7MN-6R J7KN-62 J77MN-VD-9 J77MN-HU-9 J7MN-9R 37 J7KN-74 J77MN-VD-9 J77MN-HU-9 J7MN-9R 45 J7KN-90 Not available Not available J7MN-9R 55 J7KN-115 Not available Not available J7MN-9R 18.5 6 J7KN-18D Motor Protection Circuit Breaker J7MN Specifications ■ Engineering data and Characteristics Technical Data according to IEC/EN 60947-1, 60947-2, 60947-4-1 and VDE 0660 If the short-circuit current exceeds the rated short-circuit breaking capacity of the circuit-breaker specified in the tables at the installation point, a back-up fuse is to be used. The maximum rated current for the back-up fuse is specified in the tables. These fuses are only suitable for the short-circuit-currents as indicated on the fuses. This table shows the rated ultimate short-circuit breaking capacity Icu and the rated service short-circuit breaking capacity Ics of the J7MN circuit-breakers with different operational voltages as a function of the rated current In of the circuit-breakers. The circuit-breakers can be fed at the top or bottom supply terminals without any reduction of the rated data. Circuitbreaker Rated current In up to AC 240V*1 Icu Type A J7MN-3P 0.16 to 0.63 J7MN-3R J7MN-6R J7MN-9R -*1 *2 *3 Ics up to AC 400V*1 up to AC 415V*2 max. Icu fuse*3 (gL/gG) up to AC 440V*1 up to AC 460V*2 Icu max. fuse*3 (gL/gG) Ics Ics up to AC 500V*1 up to AC 525V*2 max. Icu fuse*3 (gL/gG) Ics up to AC 690V*1 max. Icu fuse*3 (gL/gG) Ics max. fuse*3 (gL/gG) kA kA A kA kA A kA kA A kA kA A kA kA A 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 -- 1 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 -- 1.6 100 100 -- 100 100 -- 100 100 -- 100 100 -- 3 3 20 2.5 100 100 -- 100 100 -- 100 100 -- 50 100 -- 3 3 35 4 100 100 -- 100 100 -- 100 38 50 15 38 50 3 3 40 6 100 100 -- 100 100 -- 50 11 50 10 11 40 3 3 50 8 100 100 -- 100 100 -- 15 11 63 10 8 40 3 3 63 10 100 100 -- 50 38 80 15 11 63 6 8 63 3 3 63 13 100 100 -- 50 38 80 10 8 80 6 5 63 3 3 63 17 50 38 -- 20 15 100 10 8 80 6 5 80 3 3 63 22 40 30 125 15 11 100 8 6 100 6 5 80 3 3 63 26 40 30 125 15 11 100 8 6 100 6 5 80 3 3 63 32 30 22 125 15 11 100 6 4 100 5 4 80 3 3 63 0.16 to 1.0 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 -- 1.6 100 100 -- 100 100 -- 100 100 -- 100 100 -- 100 100 -- 2.5 100 100 -- 100 100 -- 100 100 -- 100 100 -- 8 8 35 4 100 100 -- 100 100 -- 100 100 -- 100 100 -- 8 8 40 6 100 100 -- 100 100 -- 100 100 -- 100 100 -- 6 6 50 8 100 100 -- 100 100 -- 50 38 80 50 38 63 6 6 63 10 100 100 -- 100 100 -- 50 38 80 50 38 80 6 6 63 13 100 100 -- 100 100 -- 50 38 80 42 32 80 6 6 63 17 100 100 -- 50 38 100 20 15 80 10 8 80 4 4 63 22 100 100 -- 50 38 125 20 15 100 10 8 80 4 4 63 26 100 100 -- 50 38 125 20 15 100 10 8 80 4 4 63 32 100 100 -- 50 38 125 20 15 100 10 8 80 4 4 63 26 100 100 -- 50 50 125 35 27 125 12 9 100 5 5 80 32 100 100 -- 50 50 125 35 27 125 10 8 100 5 5 80 40 100 100 -- 50 50 160 35 27 125 10 8 100 5 5 80 50 100 100 -- 50 50 160 35 27 125 10 8 100 5 5 80 63 100 100 -- 50 50 160 35 27 160 10 8 100 5 5 80 63 100 100 -- 50 38 160 40 30 160 12 9 100 6 5 80 75 100 100 -- 50 38 160 40 30 160 8 6 125 5 4 100 90 100 100 -- 50 38 160 40 30 160 8 6 125 5 4 125 100 100 100 -- 50 38 160 40 30 160 8 6 125 5 4 125 No back-up fuse required 10% overvoltage 5% overvoltage Back up fuse required if short-circuit current at installation point > Icu Motor Protection Circuit Breaker J7MN 7 Technical Data according to IEC/EN 60947-1, 60947-2, 60947-4-1 and VDE 0660 Main Circuit Type J7MN-3P J7MN-3R J7MN-6R Number of poles J7MN-9R 3 Max. rated current Inmax (=max. rated operational current Ie) Permissible ambient temperature 32 A 32 A Storage/transport 63 A 100 A -50 to +80°C Operation -20 to +60°C Storage/transport -58 to +176°F Operation -4 to +140°F 690 V*1 Rated insulation voltage Ui Rated impulse withstand voltage Uimp 1000 V*2 6 kV 8 kV Rated operational voltage Ue 690 V Rated frequency 50/60 Hz Utilization category IEC 60 947-2 (circuit-breaker) A IEC 60 947-4-1 (motor starter) AC3 Class acc. to IEC 60 947-4-1 Power loss Pv per circuit-breaker In -> up to 4 A dependent on rated current In In -> 6 up to 26 A 10 9.8 W - 8W - (upper setting range) In -> 32 A R per conducting path = P/I² × 3 In -> 26 up to 63 A - - 12.6 W - In -> up to 63 A W - - - 11.9 W In -> 75 up to 100 A - - - 15 W Shock resistance 3.9 W - acc. to IEC 68 Part 2-27 25 g Degree of protection acc. to IEC 60 529 Shock hazard protection acc. to DIN VDE 0106 Part 100 IP 20 Weight safe against finger touch 0.32 kg Temperature compensation 0.36 kg acc. to IEC 60 947-4-1 1 kg 2.2 kg -20 to +60°C Mechanical endurance operating cycles 100,000 50,000 Electrical endurance operating cycles 100,000 25,000 Max. operating frequency per hour (motor starts) 1/h 25 *1 Suitable at 690 V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 6 kV. *2 Suitable at 1000 V for: earthed-neutral systems, overvoltage category I to IV, pollution degree 3 (standard-industry): Uimp = 8 kV. Data for other conditions on request. Conductor cross-sections for main circuit Type J7MN-3 J7MN-6 J7MN-9 Screw type, terminal type Pz2 Pz2 4 mm hexagon socket screw Tightening torque 0.8 to 2.5 Nm 3 to 4.5 Nm 4 to 6 Nm 7 to 22 lb-in 26 to 39 lb-in 35 to 53 lb-in 1 x (1 to 10) mm² 1 x (0.75 to 35) mm² 1 x (2.5 to 70) mm² 2 x (1 to 6) mm² 2 x (0.75 to 25) mm² 2 x (2.5 to 50) mm² 1 x (18 to 8) AWG 1 x (18 to 2) AWG 1 x (12 to 2/0) AWG 2 x (12 to 1/0) AWG Conductor cross-sections solid stranded flexible 8 2 x (18 to 10) AWG 2 x (18 to 4) AWG 1 x (1 to 6) mm² 1 x (0.75 to 35) mm² 1 x (2.5 to 70) mm² 2 x (1 to 6) mm² 2 x (0.75 to 25) mm² 2 x (2.5 to 50) mm² 1 x (18 to 10) AWG 1 x (18 to 2) AWG 1 x (12 to 2/0) AWG 2 x (18 to 10) AWG 2 x (18 to 4) AWG 2 x (12 to 1/0) AWG 1 x (1 to 6) mm² 1 x (0.75 to 25) mm² 1 x (2.5 to 50) mm² 2 x (0.75 to 4) mm² 2 x (0.75 to 16) mm² 2 x (2.5 to 35) mm² 1 x (18 to 10) AWG 1 x (18 to 4) AWG 1 x (12 to 1/0) AWG 2 x (18 to 10) AWG 2 x (18 to 6) AWG 2 x (10 to 2) AWG Motor Protection Circuit Breaker J7MN Auxiliary switches Aux. Type Switching capacity Control voltage J77MN-11F/20F/02F & J7MN-T(A/B) Rated operational voltage Front transverse auxiliary switch with 1 Rated operational current NO + 1 NC, 2 NO, 2 NC J77MN-11S/20S/02S Lateral auxiliary switch with 1 NO + 1 NC, 2 NO, 2 NC & two signalling switches with 1 NO + 1 NC J77MN-U Undervoltage release 24 VAC 240 VAC Ie/AC-15 3A 2A 5A Ie/AC-12 Ith 5A Rated operational voltage Ue L/R 200 ms 24 VDC 220 VDC Rated operational current Ie/DC-13 1A 0.1 A Rated operational voltage Ue 24 VAC 240 VAC Rated operational current Ie/AC-15 6A 4A Ie/AC-12 Ith 10 A Rated operational voltage Ue L/R 200 ms 24 VDC 220 VDC Rated operational current Ie/DC-13 2A 0.25 A Power consumption during pick-up 8.5 VA / 6 W uninterrupted duty 3 VA / 1.2 W Response voltage J77MN-S Shunt release Ue Power consumption Response voltage trip 0.7 to 0.35 × Us (V) pick-up 0.85 to 1.1 × Us (V) during pick-up 8.5 VA / 6 W uninterrupted duty 3 VA / 1.2 W trip 0.7 to 1.1 × Us (V) Short-circuit protection for auxiliary and control circuits Fuse gL/gG 10 A Miniature circuit breaker C-characteristic Conductor cross-sections for auxiliary and control circuits 6A Screw-type Pz2 solid 1 x (0.5 to 2.5) / 2x (0.5 to 2.5) mm² flexible 1 x (0.5 to 4) / 2 x (0.75 to 2.5) mm² solid AWG 1 x (20 to 14) / 2 x (20 to 14) AWG flexible AWG 1 x (20 to 10) / 2 x (18 to 14) AWG Time/Current characteristic Minute Ir=10.4, ..., 15.6 X In Second Operation time Second Operation time Minute Hour J7MN-6R & J7MN-9R Hour J7MN-3P & J7MN-3R Reflex tripping: t5 ms Time Ir=10.4, ..., 15.6 X In Reflex tripping: t5 ms Time Multiple of set current × Ie Multiple of set current × Ie I The curve shows the mean operating current at an ambient temperature of 20°C starting from cold. II The tripping characteristic of electromagnetic overcurrent releases (short-circuit releases) The tripping characteristic of the inverse-time delayed overload releases apply for DC and AC with a frequency of 0 to 400 Hz. At operating temperature, the tripping times of the thermal releases are reduced to approximately 25 %. The characteristic shown here is a schematic representation of circuit-breakers for all ranges. Current limiting characteristics and I²t characteristics are available on request. Motor Protection Circuit Breaker J7MN 9 Permissible ratings of devices approved for North America Circuit breakers J7MN as „Manual Motor Starter“ If used as „Manual Motor Starter“ the circuit breaker is always operated in combination with a short circuit device. For use with approbated fuses or circuit breakers according to UL489 or CSA22.2 No. 5 only. The sizes are selected according to National Electrical Code (UL), or Canadian Electrical Code (CSA) J7MN-3 Rated operational current Max. short-circuit current Ie J7MN-3P 240 V 0.16 0.25 0.4 0.63 100 100 100 100 1 1.6 2.5 4 6 8 10 13 17 22 26 32 A 100 100 100 100 100 100 50 50 40 30 30 20 kA 7.5 kA 480 V 50 50 50 50 50 50 50 50 25 25 10 10 10 10 7.5 600 V 10 10 10 10 10 10 10 5 5 5 5 5 5 5 5 5 kA J7MN-3R 240 V 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 kA 480 V 50 50 50 50 50 50 50 50 50 50 50 50 30 30 30 30 kA 600 V 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 kA 115 V - - - - - - - 1 /8 1 /4 1 /3 1 1 /2 1 1 1 /2 2 2 HP 230 V - - - - - 1 /2 1 1 1 /2 2 3 3 5 5 HP 71/2 HP Motor load 1-phase Motor load 3-phase 1 /10 1 /6 1 /3 3 /2 200 V - - - - - - 1 /2 /4 1 2 2 3 3 5 7 1 /2 230 V - - - - - 1 /3 1 /2 1 1 1 /2 2 3 3 5 7 1 /2 7 1 /2 10 HP 460V - - - - 1 /2 3 /4 1 2 3 5 5 7 1 /2 10 15 15 20 HP 1 600V Max. rated fuse Max. breaker size - - - - /2 1 1 1 /2 3 5 5 10 10 15 20 20 1 1 1 1 3 6 10 15 20 30 40 50 60 80 100 125 A 15 15 15 15 15 15 15 15 20 30 40 50 60 80 100 125 A J7MN-6R Rated operational current Ie Max. short-circuit current J7MN-9R 26 32 40 50 63 63 75 90 100 A 240 V 100 100 100 100 100 100 100 100 100 kA 480 V 50 50 50 50 50 25 25 25 25 kA 600 V 10 10 10 10 10 10 10 10 10 kA Motor load 1-phase 115 V 2 3 3 5 5 5 7 1 /2 10 10 HP 230 V 5 5 7 1 /2 10 15 15 15 20 20 HP Motor load 3-phase 230 V 10 10 15 15 20 25 25 30 40 HP 460V 20 25 30 401/2 50 50 60 75 75 HP 100 HP 600V 30 HP 25 30 40 50 60 60 75 100 Max. rated fuse 100 125 150 200 250 250 300 350 400 A Max. breaker size 100 125 150 200 250 250 300 350 400 A Circuit breakers J7MN as "Combination Motor Controller Type E" and " Suitable for Group Installation" J7MN-9R are approved to UL 508 in combination with the insulation barriers J7MN-TB100. According to CSA these terminal blocks can be omitted when the device is used as "Combination Motor Controller Type E“. Acc to UL508 demands a line-side 1 inch air and 2 inch creepage distance for „Combination Motor Controller Type E“ is necessary. Therefore circuit breaker J7MN-3R is approved to UL 508 in combination with the Terminal block J75-BTC-25-EC. Circuit-breakers J7MN-3R + J75-BTC-25-EC Rated operational current Ie 0.16 0.25 0.4 0.63 1 1.6 2.5 4 6 8 10 13 17 22 26 32 A Max. short-circuit current 240 V 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 100 kA 480 V 50 50 50 50 50 50 50 50 50 50 50 50 30 30 30 30 kA 600 V 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 kA 115 V - - - - - - - 1 /8 1 /4 1 /3 1 1 /2 1 1 1 /2 2 2 HP 230 V - - - - - 1 /2 1 1 1 /2 2 3 3 5 5 HP 71/2 HP Motor load 1-phase Motor load 3-phase 10 /10 1 /6 1 /3 3 200 V - - - - - - 1 /2 /4 1 2 2 3 3 5 7 1 /2 230 V - - - - - 1 /3 1 /2 1 1 1 /2 2 3 3 5 7 1 /2 7 1 /2 10 HP 460V - - - - 1 /2 3 /4 1 2 3 5 5 7 1 /2 10 15 15 20 HP 1 /2 1 1 1 /2 3 5 5 10 10 15 20 20 500 500 500 500 500 500 500 500 500 500 500 600V Max. rated fuse or breaker 1 /2 - - - - 500 500 500 500 Motor Protection Circuit Breaker J7MN 30 HP 500 A J7MN-6R Rated operational current Ie Max. short-circuit current J7MN-9R + J77MN-TB100 26 32 40 50 63 63 75 90 100 A 240 V 100 100 100 100 100 100 100 100 100 kA 480 V 50 50 50 50 50 40 40 40 40 kA 600 V 10 10 10 10 10 10 10 10 10 kA Motor load 1-phase 115 V 2 3 3 5 5 5 7 1 /2 10 10 HP 230 V 5 5 7 1 /2 10 15 15 15 20 20 HP Motor load 3-phase 230 V 10 10 15 15 20 25 25 30 40 HP 460V 20 25 30 40 50 50 60 75 75 HP 60 60 75 100 100 HP 600V Max. rated fuse or breaker 25 30 40 50 600 600 600 600 600 1,000 1,000 1,000 1,000 A Combination Motor Controller Type E Ratings of auxiliary switches and alarm switches Lateral auxiliary switch with J77MN-xxS and signalling switch J77MN-T Transversal auxiliary switch with J77MN-xxF Breaking capacity A600 A300 AC Q300 R300 DC Descriptions Releases Circuit-breakers J7MN are equipped with bimetallic-based, inversetime delayed overload releases and with instantaneous overcurrent releases (electromagnetic short-circuit releases). The overload releases can be set in accordance with the load current. The overcurrent releases are permanently set to a value 13 times the rated current and thus enable trouble-free start-up of motors. The scale cover can be sealed to prevent unauthorized adjustments to the set current. Operating mechanisms Circuit-breakers J7MN-3P are actuated via a rocker operating mechanism and circuit-breakers J7MN-3R, J7MN-6R and J7MN-9R via a rotary operating mechanism. An electrical signal can be output, at all Circuit-breakers, via a signalling switch to indicate that the Circuitbreaker has tripped. All operating mechanisms can be locked in the 0 position with a padlock (shackle diameter 3.5 to 4.5 mm). The J7MN Circuit-breakers fulfil the isolation characteristics specified in IEC 60947-2. Operating conditions premature tripping due to phase failure sensitivity, the three conducting paths must always be uniformly loaded. The conducting paths must be connected in series in the case of single-phase loads. Short-circuit protection The short-circuit releases of J7MN circuit-breakers disconnect the faulty load feeder from the system in the event of a short circuit and thus prevent any further damage from being caused. Circuit-breakers with a short-circuit breaking capacity of 50 kA or 100 kA at a voltage of 400 V AC are practically short-circuit-proof at this voltage, as higher short-circuit currents are not usually encountered at the installation point. Back-up fuses are only necessary if the short-circuit current at the installation point exceeds the rated ultimate short-circuit breaking capacity of the circuit-breakers. Motor protection The tripping characteristics of J7MN circuit-breakers are designed mainly to protect three-phase induction motors. The circuit-breakers are therefore also referred to as Manual Motor Starters. The current of the motor to be protected is set with the aid of the scale. Line protection Circuit-breakers J7MN are suitable for use in any climate. They are designed for operation in enclosed rooms under normal conditions (e. g. no dust, corrosive vapours or harmful gases). Suitable enclosures must be provided for installation in dusty or damp rooms. Circuit-breakers J7MN can also be fed from below. In order to prevent J7MN Circuit-breakers for motor protection are also suitable for line protection. The J7MN Circuit-breakers fulfil the isolation conditions of IEC 60 947-3 as well as the additional test conditions for circuitbreakers with isolation characteristics specified in IEC 60947-2. Taking IEC 60 204-1 into consideration, they can thus be implemented as main and EMERGENCY STOP switches. Door-coupling rotary operating mechanism do not fulfil the isolation characteristics. Wiring diagrams Circuit breakers Traverse Aux. Contact blocks J7MN J77MN-11F Alarm Switch J77MN-T-11S J77MN-TA-11S/ J77MN-TB-11S J77MN-20F Aux. Contact Block (side mounted) J77MN-02F J77MN-11S Undervoltage Release Shunt Release J77MN-U-... J77MN-S-... J77MN-20S Motor Protection Circuit Breaker J77MN-02S J7MN 11 Dimensions Circuit-breaker J7MN-3P Height of arcing spaces (clearance from earthed parts ) at Ue (V) 240 415 460 525 mm 20 20 20 20 690 20 inch 0.8 0.8 0.8 0.8 0.8 Circuit-breaker J7MN-3R Height of arcing spaces (clearance from earthed parts ) at Ue (V) 240 415 460 525 690 mm 30 30 30 30 50 inch 1.18 1.2 1.18 1.18 2 Circuit-breaker J7MN-6R Height of arcing spaces (clearance from earthed parts ) at Ue (V) 240 415 460 525 690 mm 50 50 50 50 50 inch 2 2 2 2 2 Circuit-breaker J7MN-9R Height of arcing spaces (clearance from earthed parts ) at Ue (V) All 12 1) 2) 3) 4) 5) Side aux. contact Magnetic trip alarm Shunt or undervoltage release of arcing Transverse aux. contact 35 mm DIN-rail acc. to EN 50022 Motor Protection Circuit Breaker J7MN 240 415 460 525 690 mm 50 70 70 110 150 inch 2 2¾ 2¾ 4,33 6 3P/3R 6) Push-in Lugs for screw mounting 3R/6R/9R 7) Handle lock in OFF-position ( 5 mm) 9R 8) 4 mm hexagon socket screw 9) 70 mm DIN-rail acc. to EN 50023 Enclosure J77MN-PF Door-coupling rotary operating mechanism J77MN-DC Type A J77MN-DC-3R-115-B 149-210 J77MN-DC-3R-115-RY 149-210 J77MN-DC-3R-315-B 149-410 J77MN-DC-3R-315-RY 149-410 Type A J77MN-DC-6R-115-B 194-255 J77MN-DC-6R-115-RY 194-255 J77MN-DC-6R-315-B 194-455 J77MN-DC-6R-315-RY 194-455 Type A J77MN-DC-9R-115-B 220-282 J77MN-DC-9R-115-RY 220-282 J77MN-DC-9R-315-B 220-482 J77MN-DC-9R-315-RY 220-482 Motor Protection Circuit Breaker J7MN 13 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. J08E-EN-03B 14 In the interest of product improvement, specifications are subject to change without notice. Motor Protection Circuit Breaker J7MN
J77MN11S 价格&库存

很抱歉,暂时无法提供与“J77MN11S”相匹配的价格&库存,您可以联系我们找货

免费人工找货