6EP41350GB000AY0

6EP41350GB000AY0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SITOP DC UPS1100 MODULE,24V/12 A

  • 数据手册
  • 价格&库存
6EP41350GB000AY0 数据手册
Data sheet 6EP4135-0GB00-0AY0 SITOP UPS1100/BATTERY MODULE/24V/12AH SITOP UPS1100 Battery module with warning not closed Lead batteries for SITOP DC-USV Modules; DC 24 V 12 Ah Charging current charging voltage end-of-charge voltage at DC ● at -10 °C recommended 28 V ● at 0 °C recommended 28 V ● at 10 °C recommended 27.8 V ● at 20 °C recommended 27.3 V ● at 30 °C recommended 26.8 V ● at 40 °C recommended 26.6 V ● at 50 °C recommended 26.3 V Output Rated current value Iout rated 40 A Permissible charging current, max. 3A Rated voltage Vout DC 24 V Safety Short-circuit protection Battery fuse 2x 25 A/32 V (solid-state circuitry blade-type fuse + support) design of the overload protection Valve control Status display LED green: Battery OK; LED flashing green: Error or warning; OFF: No communication Safety Protection class Class III Degree of protection (EN 60529) IP20 Approvals CE mark Yes UL/cUL (CSA) approval cURus-Recognized (UL 1778, CSA C22.2 No. 107.1), File E219627 Explosion protection IECEx Ex nA nC IIC T4 Gc; cCSAus (CSA C22.2 No. 213-M1987, ANSI/ISA-12.12.01-2013) Class I, Div. 2, Group ABCD, T4 Approvals Yes Marine approval DNV GL, ABS environmental conditions Operating data note 6EP41350GB000AY0 Page 1/2 For storage, mounting and operation of lead-acid batteries, the relevant DIN/VDE regulations or country-specific regulations (e.g. VDE 0510 Part 2/EN 50272-2) must be observed. You must ensure that the battery site is sufficiently ventilated. Possible sources of ignition must be at least 50 cm away. 12.18.2020 Subject to change without notice © Copyright Siemens ambient temperature ● during operation -15 ... +50 °C ● during transport -20 ... +50 °C ● during storage -20 ... +50 °C relative temporary capacity loss at 20 °C in a month typical 3% Service life service life of energy storage ● typical note capacity falls to 80 % of original capacity (according to EUROBAT) ● at 20 °C typical 4y ● at 30 °C typical 2y ● at 40 °C typical 1y ● at 50 °C typical 0.5 y ambient temperature during storage note Along with the storage and operating temperature, other factors such as the duration of the storage period and the charge status during storage have a decisive influence on the possible useful life. Batteries should therefore be stored as briefly as possible, always fully charged, and within the temperature range 0 to +20 °C. Mechanics Connection technology screw-type terminals Connection for power supply unit 1 screw terminal each for 0.5 ... 16 mm² for + BAT and - BAT type of electrical connection for control circuit and status message 1 screw terminal each for 0.14 ... 4 mm² product component included Accessories pack with solid-state circuitry fuse 25 A width of the enclosure 253 mm height of the enclosure 186 mm depth of the enclosure 110 mm installation width 253 mm Installation height 201 mm Weight, approx. 9.8 kg Installation can be screwed onto flat surface (keyhole mounting for hooking in to M4 screws) number of cells 12 Battery 12 A·h other information Specifications at rated input voltage and ambient temperature +25 °C (unless otherwise specified) 6EP41350GB000AY0 Page 2/2 12.18.2020 Subject to change without notice © Copyright Siemens
6EP41350GB000AY0 价格&库存

很抱歉,暂时无法提供与“6EP41350GB000AY0”相匹配的价格&库存,您可以联系我们找货

免费人工找货