0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
7KM2112-0BA00-3AA0

7KM2112-0BA00-3AA0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    SIEMENS - 7KM2112-0BA00-3AA0 - Digital Panel Meter, Power / Energy Monitoring, Sentron PAC3200, DIN9...

  • 数据手册
  • 价格&库存
7KM2112-0BA00-3AA0 数据手册
Data sheet 7KM2112-0BA00-3AA0 SENTRON, measuring instrument, 7KM PAC3200, LCD, L-L: 690 V, L-N: 400 V, 5 A, 3-phase, Modbus TCP, optionally Modbus RTU / PROFINET / PROFIBUS, apparent / active / reactive energy, class 0.5 according to IEC61557-12 or Class 0.5S according to IEC6205322, wide voltage range power supply unit, AC/DC, screw terminal Model Product brand name SENTRON Product designation 7KM PAC3200 Design of the product basic Product type designation Measuring instrument Type of measured value detection complete Design of the power supply Wide-range power supply General technical data Cutout width 92 mm Cutout height 92 mm Size of Power Monitoring Device / company-specific size 96 Operating mode for measured value detection ● automatic line frequency detection Yes ● set at 50 Hz No ● set to 60 Hz No Pulse duration ● initial value 30 ms ● Full-scale value 500 ms 7KM2112-0BA00-3AA0 Page 1/9 06/15/2018 Subject to change without notice © Copyright Siemens Voltage curve Sinusoidal or distorted Measurable line frequency / initial value 45 Hz Measurable line frequency / Full-scale value 65 Hz Measuring procedure / for voltage measurement RMS MTBF 185.8 y Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750 P Supply voltage Supply voltage frequency / rated value ● minimum 65 Hz ● maximum 45 Hz Type of voltage / of the supply voltage AC/DC Measuring category / for supply voltage CATIII Apparent power consumption ● with expansion module / maximum 8 V·A ● without expansion module / typical 6 V·A Relative symmetrical tolerance / of the supply voltage 10 % Protection class Protection class IP ● on the front IP65 ● Rear side IP20 Operating resource protection class / when installed II Electricity Measurable current / 2 / at AC / Rated value 5 A Suitability Suitability for operation Installation in stationary control panels in closed rooms Adjustable time period / minimum 10 ms Product function Product function ● reactive power measurement Yes ● frequency measurement Yes ● pulse measurement Yes ● voltage measurement Yes ● Current measurement Yes ● active power measurement Yes Display and operation Design of the display LCD Number of keys 4 Color / of the background of the display white 7KM2112-0BA00-3AA0 Page 2/9 06/15/2018 Subject to change without notice © Copyright Siemens National language / on the display screen / is supported ger, en, fr, spa, ita, por, tur, chi Horizontal image resolution 128 Vertical screen resolution 96 Refresh time / on display ● minimum 0.33 s ● maximum 3 s Communication Refresh time / at the interface ● minimum 0.33 s ● maximum 1 s Number of interfaces / acc. to Fast Ethernet 1 Design of cable / connectable / Twisted pair Yes Protocol ● at the Ethernet interface / is supported MODBUS TCP ● is supported Modbus TCP Transfer rate ● minimum 10 000 kbit/s ● maximum 10 000 kbit/s Fault limits Reference condition / for metering accuracy Acc. to IEC62053-22 and IEC62053-23 Formula for relative total measurement inaccuracy ● for measured variable reactive energy Class 2 according to IEC61557-12 and/or IEC62053-23 ● for measured variable output +/- 0,5 % ● for measured variable output factor +/- 0,5 % ● for measured variable voltage +/- 0,3 % ● for measured variable current +/- 0,2 % ● for measured variable active energy Cl. 0.5 acc. to... IEC62053-22 Inputs Outputs Input voltage / at digital input ● initial value for signal-recognition 13 V ● at DC / rated value 24 V ● Full-scale value for signal recognition 8 V Number of digital outputs 1 Number of digital inputs 1 Digital output version switching or pulse output function Input current / at digital input ● for signal 7 mA Output current ● at digital output / with signal / maximum 0.2 mA ● at digital output / for signal / maximum 27 mA 7KM2112-0BA00-3AA0 Page 3/9 06/15/2018 Subject to change without notice © Copyright Siemens ● at the digital outputs / at DC / maximum 100 mA Output delay / at digital output ● for signal to / maximum 5 ms ● for signal to / maximum 5 ms Operating voltage / as output voltage / at DC / maximum permissible 30 V Property of the output / Short-circuit proof Yes Input delay time / at digital input ● for signal to / maximum 5 ms ● for signal to / maximum 5 ms Internal resistance / at the digital outputs 55 Ω Measuring category / for digital signals CATII Switching frequency / at digital output / maximum 17 Hz Transfer rate ● 1 / for fast Ethernet 10 Mbit/s Measuring inputs Outer conductors and neutral conductors internal 1.05 MΩ resistance / for voltage measurement Measurable supply voltage ● between (PE)N and L / at AC / minimum 40 V ● between (PE)N and L / at AC / maximum 480 V ● between (PE)N and L / at AC / maximum rated value 400 V ● between the outer conductors / at AC / minimum 70 V ● between the outer conductors / at AC / maximum 831 V ● between the outer conductors / at AC / maximum rated value 690 V Voltage measuring range extension / with external voltage transformers Yes Current measuring range extension / with external current transformers Yes Measuring category / for voltage measurement CATIII Supply voltage / between the outer conductors / at AC / maximum permissible 831 V Consumed active power / for current measurement / per phase 115 mW Continuous current / at AC / maximum permissible 10 A Measuring category / for current measurement CATIII Zero-point suppression / for current measurement 0,1 ... 10 % Relative measurable current / at AC ● minimum 1 % ● maximum 120 % 7KM2112-0BA00-3AA0 Page 4/9 06/15/2018 Subject to change without notice © Copyright Siemens Measuring procedure / for current measurement TRMS Measurable current / 1 / at AC / Rated value 1 A Connections Type of connectable conductor cross-sections ● at the digital inputs / at AWG conductors / solid 2x 24 ... 18 ● at the digital inputs / solid 1x (0.2 ... 2.5 mm²), 2x (0.2 ... 1.0 mm²) ● at the digital inputs / finely stranded / with core end processing 1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²) ● at the digital outputs / at AWG conductors / solid 2x 24 ... 18 ● at the digital outputs / solid 1x (0.2 ... 2.5 mm²), 2x (0.2 ... 1.0 mm²) ● at the digital outputs / finely stranded / with core end processing 1x (0.25 ... 2.5 mm²), 2x (0.25 ... 1.0 mm²) ● at the inputs for supply voltage / at AWG conductors / solid 2x 20 to 14 ● at the inputs for supply voltage / solid 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) ● at the inputs for supply voltage / finely stranded / with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) ● at the measurement inputs for voltage / at AWG conductors / solid 2x 20 to 14 ● at the measurement inputs for voltage / solid 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) ● at the measurement inputs for voltage / finely stranded / with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) ● at the measurement inputs for current / at AWG conductors / solid 2x 20 to 14 ● at the measurement inputs for current / solid 1x (0.5 ... 4 mm²), 2x (0.5 ... 2.5 mm²) ● at the measurement inputs for current / finely stranded / with core end processing 1x (0.5 ... 2.5 mm²), 2x (0.5 ... 1.5 mm²) Type of electrical connection ● at the measurement inputs for voltage screw-type terminals ● of the fast Ethernet interface RJ45 (8P8C) Mechanical Design Height 96 mm Height / of the display 54 mm Width 96 mm Width ● of the display 72 mm Depth 56 mm Mounting position vertical Installation depth 51 mm Mounting type / panel mounting Yes Net weight 451 g 7KM2112-0BA00-3AA0 Page 5/9 06/15/2018 Subject to change without notice © Copyright Siemens Environmental conditions Installation altitude / at height above sea level / maximum 2 000 m Standard ● for EMC for industrial sector IEC 61000-6-2 respectively IEC 61326-1:2005, table 2 ● for EMC against unloading IEC 61000-4-2: 2001-04 ● for EMC against high frequency fields IEC 61000-4-3: 2006-02 ● for EMC against conducted LF disturbance variables (industry) IEC 61000-6-4, Group 1 Klasse A / CISPR11 Gruppe 1 Klasse A FCC Part 15 Subpart B Class A ● for EMC against conducted disturbance variables via HF fields IEC 61000-4-6: 2001-12 ● for EMC against magnetic fields with power engineering frequencies IEC 61000-4-8: 2001-03 ● for EMC against quick, transient electrical disturbances IEC 61000-4-4: 2005-07 ● for EMC against voltage drops and interruptions IEC 61000-4-11: 2004-03 ● for EMC against surge voltages IEC 61000-4-5: 2001-12 ● for free fall IEC 60068-2-32: 1975 ● for pulse emitter according to IEC62053-31 ● for cyclic, environmental damp heat check IEC 60068-2-30 ● for environmental coldness check IEC 60068-2-1 ● for environmental dry heat check IEC 60068-2-2 Relative humidity / at 25 °C / without condensation / during operation ● minimum 5 % ● maximum 95 % Ambient temperature ● during operation / minimum -10 °C ● during operation / maximum 55 °C ● during storage / minimum -25 °C ● during storage / maximum 70 °C Certificates Certificate of suitability ● as EC declaration of conformity IEC 61010-1: 2001 (2nd Ed.) with Corr. 1, EN 61010-1: 2001 (2nd Ed.) and DIN EN 61010-1:2002 with "Berichtigung 1" ● as approval for Canada UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04 ● as approval for USA UL 61010-1, 2nd Ed. CAN/CSA-C22.2 NO. 61010-1-04 Reference code / acc. to DIN EN 61346-2 7KM2112-0BA00-3AA0 Page 6/9 P 06/15/2018 Subject to change without notice © Copyright Siemens General Product Approval Declaration of Conformity other Confirmation Metrological Approval Further information Information- and Downloadcenter (Catalogs, Brochures,…) http://www.siemens.com/lowvoltage/catalogs Industry Mall (Online ordering system) https://mall.industry.siemens.com/mall/en/en/Catalog/product?mlfb=7KM2112-0BA00-3AA0 Service&Support (Manuals, Certificates, Characteristics, FAQs,...) https://support.industry.siemens.com/cs/ww/en/ps/7KM2112-0BA00-3AA0 Image database (product images, 2D dimension drawings, 3D models, device circuit diagrams, ...) http://www.automation.siemens.com/bilddb/cax_en.aspx?mlfb=7KM2112-0BA00-3AA0 CAx-Online-Generator http://www.siemens.com/cax Tender specifications http://www.siemens.com/specifications 7KM2112-0BA00-3AA0 Page 7/9 06/15/2018 Subject to change without notice © Copyright Siemens POWER SENTRON ZUR SCHALTTA UC: UE: IE: SCHRAUB X/1A MAX.6 110-34 MESS OD M -X2 V1 V2 V3 VN L/+ N/- -X4 FE DI- DI+ DO- DO+ LAN -P -X1 IL1/k IL1/l IL2/k IL2/l IL3/k -X3 IL3/l POWER SENTRON PANEL FOR VAUX: VIN: AMPIN: COMPRES MAX.6 MEAS 110 MO X/1 M POWER SENTRON ZUR SCHALTTA UC: UE: IE: SCHRAUB X/1A MAX.6 110-34 MESS OD M -X2 V1 V2 V3 VN L/+ N/- -X4 FE DI- DI+ DO- DO+ LAN -P -X1 IL1/k IL1/l IL2/k IL2/l IL3/k -X3 IL3/l POWER SENTRON PANEL FOR VAUX: VIN: AMPIN: COMPRES MAX.6 MEAS 110 MO X/1 M 7KM2112-0BA00-3AA0 Page 8/9 06/15/2018 Subject to change without notice © Copyright Siemens 7KM2112-0BA00-3AA0 Page 9/9 06/15/2018 Subject to change without notice © Copyright Siemens
7KM2112-0BA00-3AA0 价格&库存

很抱歉,暂时无法提供与“7KM2112-0BA00-3AA0”相匹配的价格&库存,您可以联系我们找货

免费人工找货