VND600PEP-E
Double channel high side driver
Features
Type
RDS(on)
Ilim
VCC
VND600PEP-E
30mΩ (1)
25A
36V
1. Per each channel
PowerSSO-24
■
DC short circuit current: 25A
■
CMOS compatible inputs
■
Proportional load current sense
■
Undervoltage and overvoltage shutdown
■
Overvoltage clamp
■
Thermal shutdown
■
Current limitation
■
Very low standby power dissipation
■
Protection against: loss of ground and loss of
VCC
■
Reverse battery protection (see Application
schematic on page 13)
■
In compliance with the 2002/95/ec european
directive
Table 1.
Description
The VND600PEP-E is a monolithic device made
using STMicroelectronics VIPower™ M0-3
technology. It is intended for driving resistive or
inductive loads with one side connected to
ground. Active VCC pin voltage clamp protects the
device against low energy spikes (see ISO7637
transient compatibility table).
This device has two channels in high side
configuration; each channel has an analog sense
output on which the sensing current is
proportional (according to a known ratio) to the
corresponding load current. Built-in thermal shutdown and outputs current limitation protect the
chip from over temperature and short circuit.
Device turns off in case of ground pin
disconnection.
Device summary
Order codes
Package
PowerSSO-24
September 2013
Tube
Tape and reel
VND600PEP-E
VND600PEPTR-E
Doc ID 11248 Rev 7
1/26
www.st.com
1
Contents
VND600PEP-E
Contents
1
Block diagram and pin description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
2
Electrical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
3
2.1
Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2.2
Thermal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
2.3
Electrical characteristics . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Application information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
3.1
4
6
2/26
. . . . . . . . . . . . . . . . . . 13
3.1.1
Solution 1: resistor in the ground line (RGND only) . . . . . . . . . . . . . . . . 13
3.1.2
Solution 2: a diode (DGND) in the ground line . . . . . . . . . . . . . . . . . . . . 14
3.2
Load dump protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.3
Microcontroller I/Os protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
3.4
Electrical characteristics curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Package and PC board thermal data . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
4.1
5
GND protection network against reverse battery
PowerSSO-24 thermal data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Package and packing information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.1
ECOPACK® packages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.2
PowerSSO-24 mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
5.3
Packing information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Doc ID 11248 Rev 7
VND600PEP-E
List of tables
List of tables
Table 1.
Table 2.
Table 3.
Table 4.
Table 5.
Table 6.
Table 7.
Table 8.
Table 9.
Table 10.
Table 11.
Table 12.
Table 13.
Table 14.
Table 15.
Table 16.
Table 17.
Device summary . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1
Suggested connections for unused and not connected pins . . . . . . . . . . . . . . . . . . . . . . . . 5
Absolute maximum ratings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Thermal data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Power . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Switching (VCC =13V) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
VCC - output diode . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Logic input (channels 1, 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Current sense (9V≤VCC≤16V). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Protections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Truth table (per channel) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Electrical transient requirements (part 1/3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Electrical transient requirements (part 2/3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Electrical transient requirements (part 3/3) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Thermal parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
PowerSSO-24 mechanical data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Document revision history . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25
Doc ID 11248 Rev 7
3/26
List of figures
VND600PEP-E
List of figures
Figure 1.
Figure 2.
Figure 3.
Figure 4.
Figure 5.
Figure 6.
Figure 7.
Figure 8.
Figure 9.
Figure 10.
Figure 11.
Figure 12.
Figure 13.
Figure 14.
Figure 15.
Figure 16.
Figure 17.
Figure 18.
Figure 19.
Figure 20.
Figure 21.
Figure 22.
Figure 23.
Figure 24.
Figure 25.
Figure 26.
Figure 27.
Figure 28.
4/26
Block diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Configuration diagram (top view) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
Current and voltage conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Switching characteristics (resistive load RL=2.6) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Waveforms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Application schematic . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
IOUT/ISENSE versus IOUT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Off-state output current. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
High level input current . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Input clamp voltage. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Input high level voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Input low level voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Input hysteresis voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
Overvoltage shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
ILIM vs Tcase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Turn-on voltage slope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Turn-off voltage slope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
On-state resistance vs Tcase . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
On-state resistance vs VCC. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
PowerSSO-24 PC board. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Rthj-amb vs PCB copper area in open box free air condition . . . . . . . . . . . . . . . . . . . . . . . 18
Maximum turn-off current versus load inductance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Demagnetization . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
PowerSSO-24 thermal impedance junction ambient single pulse . . . . . . . . . . . . . . . . . . . 20
Thermal fitting model of a double channel HSD in PowerSSO-24 . . . . . . . . . . . . . . . . . . . 20
PowerSSO-24 package dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
PowerSSO-24 tube shipment (no suffix) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
PowerSSO-24 tape and reel shipment (suffix “TR”) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Doc ID 11248 Rev 7
VND600PEP-E
1
Block diagram and pin description
Block diagram and pin description
Figure 1.
Block diagram
Figure 2.
Configuration diagram (top view)
Table 2.
Suggested connections for unused and not connected pins
Connection / pin
Current sense
N.C.
Output
Input
X
X
X
X
Not allowed
Through 10 kΩ resistor
Floating
To ground
Through 1 kΩ resistor
Doc ID 11248 Rev 7
5/26
Electrical specifications
2
VND600PEP-E
Electrical specifications
Figure 3.
Current and voltage conventions
Note:
VFn = VCCn - VOUTn during reverse battery condition.
2.1
Absolute maximum ratings
Stressing the device above the rating listed in the “Absolute maximum ratings” table may
cause permanent damage to the device. These are stress ratings only and operation of the
device at these or any other conditions above those indicated in the operating sections of
this specification is not implied. Exposure to the conditions in table below for extended
periods may affect device reliability. Refer also to the STMicroelectronics SURE Program
and other relevant quality document.
Table 3.
Absolute maximum ratings
Symbol
Value
Unit
41
V
VCC
DC supply voltage
-VCC
Reverse supply voltage
-0.3
V
- IGND
DC reverse ground pin current
-200
mA
Internally limited
A
-21
A
+/-10
mA
-3
+15
V
V
IOUT
Output current
IR
Reverse output current
IIN
Input current
VCSENSE
6/26
Parameter
Current sense maximum voltage
Doc ID 11248 Rev 7
VND600PEP-E
Electrical specifications
Table 3.
Absolute maximum ratings (continued)
Symbol
Parameter
Value
Unit
VESD
Electrostatic discharge (human body model:
R=1.5KΩ; C=100pF)
– Input
– Current sense
– Output
– VCC
4000
2000
5000
5000
V
V
V
V
EMAX
Maximum switching energy (L=0.13mH;
RL=0Ω; Vbat=13.5V; Tjstart=150ºC; IL=40A)
146
mJ
Power dissipation at Tc=25°C
96
W
Internally limited
°C
Ptot
Tj
Junction operating temperature
Tc
Case operating temperature
-40 to 150
°C
Storage temperature
-55 to 150
°C
TSTG
2.2
Thermal data
Table 4.
Thermal data
Symbol
Parameter
Rthj-case
(1)
Thermal resistance junction-case (max)
Rthj-case
(2)
Thermal resistance junction-case (max)
Rthj-amb
Thermal resistance junction-ambient (max)
Value
Unit
1.8
°C/W
1.3
54(3)
°C/W
39(4)
°C/W
1. one channel ON
2.
two channels ON
3. When mounted on a standard single-sided FR-4 board with 0.5cm2 of Cu (at least 35μm thick).
4. When mounted on a standard single-sided FR-4 board with 8cm2 of Cu (at least 35μm thick).
2.3
Electrical characteristics
8V