• Single and Multiple Outputs
• Wide Range AC Input
• Low Profile, Industry Standard Footprint
• Global Safety Agency Compliance
• RoHS Compliant
Key Market Segments & Applications
Video/Audio Routers
Datacom
Point of Sale
Test and Measurement
LED Signs and Lighting
ZP40 & 60 Series
2" x 4" 40W to 60W
AC-DC Power Supplies
ZP40 & 60 Features and Benefits
Features
Benefits
• Industry Standard Footprint
• Up to 88% efficiency
• Broad Product Range
• Meets EN61000-4 Immunity
Specifications
ITEMS
Input Voltage range
Inrush Current (132/265VAC)
Input Current (115/230VAC)
Temperature Coefficient
Voltage Accuracy
Minimum Load
Load Regulation
(1)
Line Regulation
(2)
Ripple & Noise
(3)(4)
Short Circuit Protection
Overvoltage Protection
Hold Up Time (Typ)
LED Indicator
Operating Temperature
Storage Temperature
Humidity (non condensing)
Cooling
Withstand Voltage
Isolation Resistance
Vibration (non operating)
Shock
Safety Agency Approvals
(6)
Conducted & Radiated EMI (5)
Immunity
Weight (Typ)
Size (WxLxH)
Warranty
Notes:
• Available to Second Source
• Less System Heating
• Optimization of Power Supply to System
• Greater Reliability
MODEL
A
A
A
mV
V
ms
-
g
mm
yrs
ZPS40
ZPS60
ZPD40
ZPT40
90 - 264VAC (47 - 440Hz) or 120 - 370VDC
25 / 50 (cold start)
1.6 / 1.0
±0.05%/°C
±1%
V1: ±3%, V2: ±4%, V3: ±3%
None
V1: 0.4A, V2: 0.2A
±1%
V1: ±3%, V2: ±5%, V3: ±1%
±0.5%
V1: ±1%, V2: ±2%, V3: ±1%
1% or 50mV whichever is greater
Continuous - hiccup mode
Typically 110-130% of nominal
8ms at 115VAC input
Green LED = OK
None
0 to +70°C with derating
-20 to +85°C
10 - 95% RH
Convection
Input to Ground 1.5kVAC, Input to Output 3kVAC, Output to Ground 500VAC for 1 min.
>100MΩ at 25°C & 70%RH, Output to Ground 500VDC
23.52m/s2 (10 - 55Hz: constant sweep 1 min X, Y, Z for 1 hour)
< 196.1 m/s2 (20G)
IEC/UL/CSA/EN62368-1, 60950-1, CE Mark
EN55022-B, FCC Class B
EN61000-4-2,-3,-4,-5,-6,-8
180g
101.6 X 50.8 X 30.48 (including underside components )
2
(1) ZPD, ZPT for a 60% to 100% or 100% to 60% change in load
(2) ZPT40-3512N V2: ±3%, ZPS/ZPD40: 100-240VAC
(5) ZPD/2PT models may require additional external filtering to meet conducted Class B
ZP40 & 60 Series
(3) Measured with 0.1µF ceramic & 10µF electrolytic at 20MHz BW
(4) ZPT40-3512N, V1 & V2 100mV
(6) Consult Sales Office for use under DC Input conditions
1
M ode l Se l e c tor
Dual
Single Output
Model
ZPS40-3R3
ZPS60-3R3
ZPS40-5
ZPS60-5
ZPS40-9
ZPS60-9
ZPS40-12
ZPS60-12
ZPS40-15
ZPS60-15
ZPS40-24
ZPS60-24
ZPS40-28
ZPS60-28
ZPS40-30
ZPS60-30
ZPS40-36
ZPS60-36
ZPS40-48
ZPS60-48
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
ZPD40-512 (7)
V1
V2
V1
V2
ZPD40-524 (7)
ZPT40-5125N (7)
ZPT40-51212N (7)
Triple Output
ZPT40-51515N
(7)
ZPT40-52412N (7)
ZPT40-5245N (7)
ZPT40-52412P (7)
ZPT40-3512N (7)
Notes:
V1
V2
V3
V1
V2
V3
V1
V2
V3
V1
V2
V3
V1
V2
V3
V1
V2
V3
V1
V2
V3
Output
Voltage (V)
3.3
3.3
5.0
5.0
9.0
9.0
12.0
12.0
15.0
15.0
24.0
24.0
28.0
28.0
30.0
30.0
36.0
36.0
48.0
48.0
+5.0
+12.0
+5.0
+24.0
+5.0
+12.0
-5.0
+5.0
+12.0
-12.0
+5.0
+15.0
-15.0
+5.0
+24.0
-12.0
+5.0
+24.0
-5.0
+5.0
+24.0
+12.0
+3.3
+5.0
-12.0