0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SMART1000LCD

SMART1000LCD

  • 厂商:

    TRIPPLITE

  • 封装:

    -

  • 描述:

    UPS 1000VA 8OUT LCD DISP USB

  • 数据手册
  • 价格&库存
SMART1000LCD 数据手册
1000 Eaton Boulevard Cleveland, OH 44122 United States SmartPro LCD 120V 1000VA 500W LineInteractive UPS, AVR, Tower, USB, TEL/DSL/Coax Protection, 8 Outlets MODEL NUMBER: SMART1000LCD Highlights ● Supports a basic desktop PC up to 60 min. during power outage ● Features 8 protected outlets—4 battery-protected, 4 surge-only ● Offers automatic voltage regulation (AVR) ● LCD screen reports real-time UPS and power status ● Plugs into any NEMA 5-15R socket Package Includes Provides reliable 1000VA/500W power protection for your desktop computer, network workstation, audio/video components or media center. Protects against surges, line noise, blackouts and brownouts. Description The SMART1000LCD SmartPro LCD 120V, 1000VA/500W Line-Interactive Uninterruptible Power Supply provides battery backup and AC power protection against blackouts, brownouts, power surges and line noise that can damage electronics or destroy data. Ideal for backing up your desktop computer or audio/visual components, this line-interactive UPS switches to battery backup mode in milliseconds to keep your connected equipment running long enough to save files and shut down safely with no data loss. While all eight NEMA 5-15R outlets protect against surges, four outlets also provide up to 3 hours of UPS battery support for a DVR component, 60 minutes of support for a basic desktop PC and LCD monitor, and 10 minutes of support at half load (250W). Automatic voltage regulation (AVR) corrects undervoltages as low as 89V without using any battery power. EMI/RFI noise filtering improves your equipment's performance and prevents damage. A 1038joule surge suppression rating protects your equipment from harmful power surges. Space-saving NEMA 5-15P plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socket and allows furniture to be placed flush against the wall. Large rotatable LCD screen with dimmer shows real-time input voltage, overload, AVR and battery statuses at a glance. With Tripp Lite's free PowerAlert software (available via free web download), the SMART1000LCD enables safe unattended system shutdown and file saves in case of a prolonged power failure. Features Reliable Battery Backup ● Provides 1000VA/500W high-performance power protection for desktop computers, audio/video components, media centers and other electronics ● Supports basic desktop computer and LCD monitor up to 60 minutes or single DVR components up to 3 hours during power outage ● Supports 50% load (250W) up to 10 minutes and full load (500W) up to 3 minutes ● 97% full-load efficiency rating saves money in energy costs ● Audible alarm indicates loss of utility power or low battery Optimized Outlets 1/6 ● SMART1000LCD SmartPro LCD 120V 1000VA/500W LineInteractive UPS ● USB cable ● Telephone cord ● Owner’s Manual 1000 Eaton Boulevard Cleveland, OH 44122 United States ● 4 NEMA 5-15R outlets deliver battery backup for devices that require constant power ● All 8 outlets protect against surges or spikes that can harm equipment or data Automatic Voltage Regulation (AVR) ● Corrects undervoltages as low as 89V with a 14% boost without drawing battery backup power Rotatable LCD Status Screen ● Large LCD screen shows real-time input voltage, overload, AVR and battery statuses ● Rotates for easy viewing in both horizontal and vertical installations ● Dimmer switch controls brightness level AC Line, Coaxial and Tel/DSL Surge Suppression ● Surge suppression rating of 1038 joules protects connected equipment and data from harmful power surges ● Tel/DSL RJ11 jacks and included cord protect standard dialup/DSL phone connection ● 2.2 Hz coaxial jacks protect CATV, broadband cable internet, satellite or broadcast antenna connections EMI/RFI Line Noise Filtering ● Removes electromagnetic and radio frequency interference that can disrupt or damage your equipment's performance USB Communication Port and Free PowerAlert Software ● HID-compliant USB port integrates with built-in power management and auto-shutdown of Windows and Mac OS X ● Works with Tripp Lite PowerAlert software available as free web download from tripplite.eaton.com/products/power-alert, to enable safe, unattended system shutdown and file saves during prolonged power failure Flexible Installation Options ● Space-saving NEMA 5-15P right-angle plug with 6-ft. (1.83 m) cord connects to any NEMA 5-15R socket ● Adapts to vertical or horizontal installation without special hardware Specifications OVERVIEW UPC Code 037332124999 UPS Type Line-Interactive INPUT Input Phase Single-Phase Rated input current (Maximum Load) 12A Nominal Input Voltage(s) Supported 120V AC UPS Input Connection Type 5-15P; Right-Angled 2/6 1000 Eaton Boulevard Cleveland, OH 44122 United States UPS Input Cord Length (ft.) 6 UPS Input Cord Length (m) 1.8 Recommended Electrical Service 15A 120V OUTPUT Output Capacity (VA) 1000 Output Capacity (kVA) 1 Output Capacity (Watts) 500 Output Capacity (kW) 0.5 Nominal Voltage Details 115v nominal output in battery mode Frequency Compatibility 60 Hz Output Voltage Regulation (Battery Mode) +/- 5% UPS Output Receptacles (Surge Suppression Only) 4 UPS outlets, 4 surge-only outlets Hot-Swap PDU options PDUB15 (2U / 8 5-15R outlets) Output AC Waveform (AC Mode) Sine wave Output AC Waveform (Battery Mode) PWM sine wave Nominal Output Voltage(s) Supported 110V; 115V; 120V Output Receptacles (8) 5-15R Individually Controllable Load Banks No BATTERY Battery Type Valve Regulated Lead Acid (VRLA) Runtime Full Load (min.) 3 min. (500W) Runtime Half Load (min.) 10 min. (250W) Expandable Runtime No DC System Voltage (VDC) 12 Battery Recharge Rate (Included Batteries) Less than 16 hours from 10% to 90% Battery Access Battery access door Internal UPS Replacement Battery Cartridge  RBC51  Battery Replacement Description Hot-swappable, user replaceable batteries VOLTAGE REGULATION Voltage Regulation Description Automatic voltage regulation (AVR) maintains line power operation with input voltage as low as 89 3/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Undervoltage Correction Input voltages between 89 and 104 are boosted by 14% USER INTERFACE, ALERTS & CONTROLS Front Panel LCD Display Backlighted LCD screen indicates input voltage, 5-bar battery charge level, overload, AVR, on battery and replace battery status; LCD screen rotates for rack/tower viewing Switches 2 Switches control off/on power status and alarm-cancel/self-test operation; dimmer switch controls LCD brightness Alarm Cancel Operation Power-fail alarm can be silenced using alarm-cancel switch; once silenced, alarm will re-sound to indicate lowbattery status Audible Alarm Audible alarm indicates power-failure and low-battery status; alarm can be disabled using PowerAlert software LED Indicators Front panel LCD display SURGE / NOISE SUPPRESSION UPS AC Suppression Joule Rating 1038 UPS AC Suppression Response Time Instantaneous UPS Dataline Suppression 1 line TEL/DSL (1 in / 1 out); Coax jacks (1 set) EMI / RFI AC Noise Suppression Yes PHYSICAL Primary Form Factor Tower Installation Form Factors Supported with Included Accessories Tower; Ultra-compact desktop Primary UPS Depth (mm) 184 Primary UPS Height (mm) 301 Primary UPS Width (mm) 93 Shipping Dimensions (hwd / in.) 15.40 x 4.80 x 10.60 Shipping Dimensions (hwd / cm) 39.12 x 12.19 x 26.92 Shipping Weight (lbs.) 16.70 Shipping Weight (kg) 7.57 UPS Housing Material ABS UPS Power Module Dimensions (hwd, cm) 30.07 x 9.30 x 18.39 UPS Power Module Dimensions (hwd, in.) 11.84 x 3.66 x 7.24 UPS Power Module Weight (kg) 7.05 UPS Power Module Weight (lbs.) 15.55 Unit Weight (lbs.) 14.9000 Unit Weight (kg) 6.76 ENVIRONMENTAL 4/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Operating Temperature Range 32° to 104°F (0° to 40°C) Storage Temperature Range 5° to 122°F (-15° to 50°C) Relative Humidity 0 to 95%, non-condensing AC Mode BTU / Hr. (Full Load) 61 Battery Mode BTU / Hr. (Full Load) 510 AC Mode Efficiency Rating (100% Load) 97% COMMUNICATIONS PowerAlert Software For local monitoring via the UPS’s built-in USB port, download PowerAlert software at https://tripplite.eaton.com/products/power-alert Communications Cable USB cable included WatchDog Compatibility Supports Watchdog application, OS and hard-reboot restart options for remote applications Network UPS Tools (NUT) Compatibility NUT compatible. See a full list of NUT compatible Tripp Lite UPS systems at https://networkupstools.org/stablehcl.html?manufacturer=Tripp%20Lite Network Management Card Description Network management not supported Communications Interface USB (HID enabled) LINE / BATTERY TRANSFER Transfer Time 3 milliseconds Low Voltage Transfer to Battery Power (Setpoint) 89 High Voltage Transfer to Battery Power (Setpoint) 139 FEATURES & SPECIFICATIONS Cold Start (Startup in Battery Mode During a Power Failure) Cold-start operation supported High Availability UPS Features Automatic Voltage Regulation (AVR); Hot swappable batteries; Surge/noise protection Green Energy-Saving Features Greater than 95% efficiency - GREEN UPS STANDARDS & COMPLIANCE Product Certifications CSA (Canada); NOM (Mexico); UL 1778 Product Compliance RoHS; FCC Part 15 Class B (USA) WARRANTY & SUPPORT Product Warranty Period (U.S. & Canada) 3-year limited warranty Product Warranty Period (Latin America) 3-year limited warranty Product Warranty Period (International) 2-year limited warranty 5/6 1000 Eaton Boulevard Cleveland, OH 44122 United States Product Warranty Period (Mexico) 3-year limited warranty Connected Equipment Insurance (U.S., Canada & Puerto Rico) $250,000 Ultimate Lifetime Insurance  © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are the property of their respective owners. 6/6
SMART1000LCD 价格&库存

很抱歉,暂时无法提供与“SMART1000LCD”相匹配的价格&库存,您可以联系我们找货

免费人工找货
SMART1000LCD
    •  国内价格
    • 1+1809.89797

    库存:0