74LV04ATPWJ

74LV04ATPWJ

  • 厂商:

    NXP(恩智浦)

  • 封装:

    TSSOP14_5X4.4MM

  • 描述:

    74LV04AT - HEX INVERTER

  • 数据手册
  • 价格&库存
74LV04ATPWJ 数据手册
74LV04AT Hex inverter Rev. 1 — 18 May 2017 1 Product data sheet General description The 74LV04AT is a hex inverter with TTL inputs. Designed to operate over a VCC range from 4.5 V to 5.5 V, the inputs are TTL compatible, which allows the device to be used to translate from 3.3 V to 5 V. Schmitt-trigger action at all inputs makes the circuit tolerant of slower input rise and fall times. This device is fully specified for partial Power-down applications using IOFF. The IOFF circuitry disables the output, preventing the damaging backflow current through the device when it is powered down. 2 Features and benefits • • • • • • • • • Direct interface with TTL levels Supply voltage range from 4.5 V to 5.5 V Typical tpd of 3.3 ns at 5 V Typical VOL(p) < 0.8 V at VCC = 5 V, Tamb = 25 °C Typical VOH(v) > 2.3 V at VCC = 5 V, Tamb = 25 °C Supports mixed-mode voltage operation on all ports IOFF circuitry provides partial Power-down mode operation Latch-up performance exceeds 250 mA per JESD 78 Class II ESD protection: – HBM ANSI/ESDA/JEDEC JS-001 Class 2 exceeds 3 kV – MM JESD22-A115-A exceeds 150 V – CDM JESD22-C101E exceeds 2 kV • Specified from -40 °C to +85 °C and from -40 °C to +125 °C 3 Ordering information Table 1. Ordering information Type number Package 74LV04ATPW Temperature range Name Description Version -40 °C to +125 °C TSSOP14 plastic thin shrink small outline package; 14 leads; body width 4.4 mm SOT402-1 74LV04AT Nexperia Hex inverter 4 Functional diagram 1 1 1 1A 1Y 2 3 2A 2Y 4 1 3 3A 3Y 6 9 4A 4Y 8 11 5A 5Y 10 13 6A 6Y 12 5 6 1 9 8 1 11 10 1 13 mna342 Figure 1. Logic symbol 4 1 5 5 2 12 A mna343 Y mna341 Figure 2. IEC logic symbol Figure 3. Logic diagram for one gate Pinning information 5.1 Pinning 1A 1 14 VCC 1Y 2 13 6A 2A 3 2Y 4 3A 5 10 5Y 3Y 6 9 4A GND 7 8 4Y 12 6Y 04 11 5A 001aac441 Figure 4. Pin configuration TSSOP20 5.2 Pin description Table 2. Pin description Symbol Pin Description 1A, 2A, 3A, 4A, 5A, 6A 1, 3, 5, 9, 11, 13 data input 1Y, 2Y, 3Y, 4Y, 5Y, 6Y 2, 4, 6, 8, 10, 12 data output GND 7 ground (0 V) VCC 14 supply voltage 74LV04AT Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 © Nexperia B.V. 2017. All rights reserved. 2 / 12 74LV04AT Nexperia Hex inverter 6 Functional description Table 3. Function table [1] Input nA Output nY L H H L [1] H = HIGH voltage level; L = LOW voltage level 7 Limiting values Table 4. Limiting values In accordance with the Absolute Maximum Rating System (IEC 60134). Voltages are referenced to GND (ground = 0 V). Symbol Parameter VCC supply voltage VI Conditions output voltage active mode Max Unit -0.5 +7.0 V [1] -0.5 +7.0 V [2] [3] -0.5 VCC + 0.5 V [2] -0.5 +7.0 V input voltage VO Min power-down or 3-state mode IIK input clamping current VI < 0 V -20 - mA IOK output clamping current VO < 0 V -50 - mA IO output current VO = 0 V to VCC - ±35 mA ICC supply current - 70 mA IGND ground current -70 - mA Tstg storage temperature -65 +150 °C - 500 mW Ptot [1] [2] [3] [4] total power dissipation Tamb = -40 °C to +125 °C [4] The minimum input voltage ratings may be exceeded if the input current ratings are observed. The output voltage ratings may be exceeded if the output current ratings are observed. This value is limited to 7.0 V maximum. For TSSOP14 packages: above 60 °C derate linearly with 5.5 mW/K. 8 Recommended operating conditions Table 5. Recommended operating conditions Voltages are referenced to GND (ground = 0 V). Symbol Parameter VCC supply voltage VI input voltage VO output voltage Conditions Tamb ambient temperature Δt/ΔV input transition rise and fall rate 74LV04AT Product data sheet Min Max 4.5 5.5 V 0 5.5 V active mode 0 VCC V power-down or 3-state mode 0 5.5 V -40 +125 °C - 20 VCC = 5.0 V ± 0.5 V All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 Unit ns/V © Nexperia B.V. 2017. All rights reserved. 3 / 12 74LV04AT Nexperia Hex inverter 9 Static characteristics Table 6. Static characteristics Voltages are referenced to GND (ground = 0 V). Symbol Parameter Conditions 25 °C -40 °C to +85 °C Min Typ Max -40 °C to +125 °C Unit Min Max Min Max VIH HIGH-level VCC = 4.5 V to 5.5 V input voltage 2 - - 2 - 2 - V VIL LOW-level VCC = 4.5 V to 5.5 V input voltage - - 0.8 - 0.8 - 0.8 V VOH HIGH-level output voltage VI = VIH or VIL; VCC = 4.5 V IO = -50 μA 4.4 - - 4.4 - 4.4 - V IO = -12 mA 3.8 - - 3.8 - 3.8 - V LOW-level output voltage VI = VIH or VIL; VCC = 4.5 V IO = 50 μA - - 0.1 - 0.1 - 0.1 V IO = 12mA - - 0.55 - 0.55 - 0.55 V IOFF power-off leakage current VI or VO = GND to 5.5 V; VCC = 0 V - - 0.5 - 5 - 5 μA II input leakage current VI = VCC or GND; VCC = 0 V to 5.5 V - - ±0.1 - ±1 - ±1 μA ICC supply current VI = VCC or GND; IO = 0 A; VCC = 5.5 V - - 2 - 20 - 20 μA ΔICC additional supply current per input pin; VI = 3.4 V; other pins at VCC or GND; IO = 0 A; VCC = 5.5 V - - 1.35 - 1.5 - 1.5 mA VOL 74LV04AT Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 © Nexperia B.V. 2017. All rights reserved. 4 / 12 74LV04AT Nexperia Hex inverter 10 Dynamic characteristics Table 7. Dynamic characteristics GND = 0 V. For test circuit see Figure 6. Symbol Parameter Conditions 25 °C [1] Min Typ tpd propagation delay nA to nY; see Figure 5 -40 °C to +85 °C -40 °C to +125 °C Unit Max Min Max Min Max [2] VCC = 4.5 V to 5.5 V CL = 15 pF - 3.3 6.3 1 7.3 1 8.1 ns CL = 50 pF - 5.1 7.7 1 8.8 1 10.4 ns CI input VI = VCC or GND; capacitance VCC = 5 V - 2 6 - 6 - 6 pF CO output VO = VCC or GND; capacitance VCC = 5 V - 5 - - - - - pF CPD power per buffer; CL = 50 pF; dissipation f = 10 MHz; capacitance VI = GND to VCC - 9 - - - - - pF [1] [2] [3] [3] Typical values are measured at Tamb = 25 °C and VCC = 5 V. tpd is the same as tPLH and tPHL. CPD is used to determine the dynamic power dissipation (PD in μW). 2 2 PD = CPD x VCC x fi x N + ∑(CL x VCC x fo) where: fi = input frequency in MHz; fo = output frequency in MHz; CL = output load capacitance in pF; VCC = supply voltage in V; N = number of inputs switching; 2 ∑(CL x VCC x fo) = sum of the outputs. Table 8. Noise characteristics GND = 0 V. For test circuit see Figure 6. Symbol Parameter Conditions Tamb = 25 °C Unit Min Typ Max VCC = 5 V; CL = 50 pF VOL(p) LOW-level output voltage (peak) - 0.2 0.8 V VOL(v) LOW-level output voltage (valley) -0.8 -0.3 - V VOH(v) HIGH-level output voltage (valley) - 4.5 - V VIH(AC) AC HIGH-level input voltage (dynamic) 2 - - V VIL(AC) AC LOW-level input voltage (dynamic) - - 0.8 V 74LV04AT Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 © Nexperia B.V. 2017. All rights reserved. 5 / 12 74LV04AT Nexperia Hex inverter 10.1 Waveforms and test circuit VI VM nA input VM GND t PHL t PLH VOH VM nY output VM VOL mna344 Measurement points are given in Table 9. VOL and VOH are typical voltage output levels that occur with the output load. Figure 5. Propagation delay input (An) to output (Yn) Table 9. Measurement points Input Output VM VM VX VY 1.5 V 0.5VCC VOL + 0.3 V VOH - 0.3 V 74LV04AT Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 © Nexperia B.V. 2017. All rights reserved. 6 / 12 74LV04AT Nexperia Hex inverter VI negative pulse tW 90 % VM 0V VI positive pulse 0V VM 10 % tf tr tr tf 90 % VM VM 10 % tW VCC VI G DUT VCC VO RL RT S1 open CL 001aad983 Test data is given in Table 10. Definitions test circuit: RT = Termination resistance should be equal to output impedance Zo of the pulse generator CL = Load capacitance including jig and probe capacitance RL = Load resistance S1 = Test selection switch Figure 6. Test circuit for measuring switching times Table 10. Test data Input VI Load tr, tf GND to 3.0 V 3.0 ns 74LV04AT Product data sheet S1 position CL RL tPHL, tPLH tPZH, tPHZ tPZL, tPLZ 15 pF, 50 pF 1 kΩ open GND VCC All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 © Nexperia B.V. 2017. All rights reserved. 7 / 12 74LV04AT Nexperia Hex inverter 11 Package outline TSSOP14: plastic thin shrink small outline package; 14 leads; body width 4.4 mm D SOT402-1 E A X c y HE v M A Z 8 14 Q A2 pin 1 index (A 3 ) A1 A θ Lp 1 L 7 detail X w M bp e 0 2.5 5 mm scale DIMENSIONS (mm are the original dimensions) UNIT A max. A1 A2 A3 bp c D (1) E (2) e HE L Lp Q v w y Z (1) θ mm 1.1 0.15 0.05 0.95 0.80 0.25 0.30 0.19 0.2 0.1 5.1 4.9 4.5 4.3 0.65 6.6 6.2 1 0.75 0.50 0.4 0.3 0.2 0.13 0.1 0.72 0.38 8o 0o Notes 1. Plastic or metal protrusions of 0.15 mm maximum per side are not included. 2. Plastic interlead protrusions of 0.25 mm maximum per side are not included. OUTLINE VERSION SOT402-1 REFERENCES IEC JEDEC JEITA EUROPEAN PROJECTION ISSUE DATE 99-12-27 03-02-18 MO-153 Figure 7. Package outline SOT402-1 (TSSOP14) 74LV04AT Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 © Nexperia B.V. 2017. All rights reserved. 8 / 12 74LV04AT Nexperia Hex inverter 12 Abbreviations Table 11. Abbreviations Acronym Description CDM Charge Device Model DUT Device Under Test ESD ElectroStatic Discharge HBM Human Body Model MM Machine Model TTL Transistor-Transistor Logic 13 Revision history Table 12. Revision history Document ID Release date Data sheet status Change notice Supersedes 74LV04AT v.1 20170518 Product data sheet - - 74LV04AT Product data sheet All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 © Nexperia B.V. 2017. All rights reserved. 9 / 12 74LV04AT Nexperia Hex inverter 14 Legal information 14.1 Data sheet status Document status [1][2] Product status [3] Definition Objective [short] data sheet Development This document contains data from the objective specification for product development. Preliminary [short] data sheet Qualification This document contains data from the preliminary specification. Product [short] data sheet Production This document contains the product specification. [1] [2] [3] Please consult the most recently issued document before initiating or completing a design. The term 'short data sheet' is explained in section "Definitions". The product status of device(s) described in this document may have changed since this document was published and may differ in case of multiple devices. The latest product status information is available on the Internet at URL http://www.nexperia.com. 14.2 Definitions Draft — The document is a draft version only. The content is still under internal review and subject to formal approval, which may result in modifications or additions. Nexperia does not give any representations or warranties as to the accuracy or completeness of information included herein and shall have no liability for the consequences of use of such information. Short data sheet — A short data sheet is an extract from a full data sheet with the same product type number(s) and title. A short data sheet is intended for quick reference only and should not be relied upon to contain detailed and full information. For detailed and full information see the relevant full data sheet, which is available on request via the local Nexperia sales office. In case of any inconsistency or conflict with the short data sheet, the full data sheet shall prevail. Product specification — The information and data provided in a Product data sheet shall define the specification of the product as agreed between Nexperia and its customer, unless Nexperia and customer have explicitly agreed otherwise in writing. In no event however, shall an agreement be valid in which the Nexperia product is deemed to offer functions and qualities beyond those described in the Product data sheet. 14.3 Disclaimers Limited warranty and liability — Information in this document is believed to be accurate and reliable. However, Nexperia does not give any representations or warranties, expressed or implied, as to the accuracy or completeness of such information and shall have no liability for the consequences of use of such information. Nexperia takes no responsibility for the content in this document if provided by an information source outside of Nexperia. In no event shall Nexperia be liable for any indirect, incidental, punitive, special or consequential damages (including - without limitation lost profits, lost savings, business interruption, costs related to the removal or replacement of any products or rework charges) whether or not such damages are based on tort (including negligence), warranty, breach of contract or any other legal theory. Notwithstanding any damages that customer might incur for any reason whatsoever, Nexperia's aggregate and cumulative liability towards customer for the products described herein shall be limited in accordance with the Terms and conditions of commercial sale of Nexperia. Right to make changes — Nexperia reserves the right to make changes to information published in this document, including without limitation specifications and product descriptions, at any time and without notice. This document supersedes and replaces all information supplied prior to the publication hereof. Suitability for use — Nexperia products are not designed, authorized or warranted to be suitable for use in life support, life-critical or safety-critical 74LV04AT Product data sheet systems or equipment, nor in applications where failure or malfunction of an Nexperia product can reasonably be expected to result in personal injury, death or severe property or environmental damage. Nexperia and its suppliers accept no liability for inclusion and/or use of Nexperia products in such equipment or applications and therefore such inclusion and/or use is at the customer’s own risk. Applications — Applications that are described herein for any of these products are for illustrative purposes only. Nexperia makes no representation or warranty that such applications will be suitable for the specified use without further testing or modification. Customers are responsible for the design and operation of their applications and products using Nexperia products, and Nexperia accepts no liability for any assistance with applications or customer product design. It is customer’s sole responsibility to determine whether the Nexperia product is suitable and fit for the customer’s applications and products planned, as well as for the planned application and use of customer’s third party customer(s). Customers should provide appropriate design and operating safeguards to minimize the risks associated with their applications and products. Nexperia does not accept any liability related to any default, damage, costs or problem which is based on any weakness or default in the customer’s applications or products, or the application or use by customer’s third party customer(s). Customer is responsible for doing all necessary testing for the customer’s applications and products using Nexperia products in order to avoid a default of the applications and the products or of the application or use by customer’s third party customer(s). Nexperia does not accept any liability in this respect. Limiting values — Stress above one or more limiting values (as defined in the Absolute Maximum Ratings System of IEC 60134) will cause permanent damage to the device. Limiting values are stress ratings only and (proper) operation of the device at these or any other conditions above those given in the Recommended operating conditions section (if present) or the Characteristics sections of this document is not warranted. Constant or repeated exposure to limiting values will permanently and irreversibly affect the quality and reliability of the device. Terms and conditions of commercial sale — Nexperia products are sold subject to the general terms and conditions of commercial sale, as published at http://www.nexperia.com/profile/terms, unless otherwise agreed in a valid written individual agreement. In case an individual agreement is concluded only the terms and conditions of the respective agreement shall apply. Nexperia hereby expressly objects to applying the customer’s general terms and conditions with regard to the purchase of Nexperia products by customer. No offer to sell or license — Nothing in this document may be interpreted or construed as an offer to sell products that is open for acceptance or the grant, conveyance or implication of any license under any copyrights, patents or other industrial or intellectual property rights. Export control — This document as well as the item(s) described herein may be subject to export control regulations. Export might require a prior authorization from competent authorities. All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 © Nexperia B.V. 2017. All rights reserved. 10 / 12 74LV04AT Nexperia Hex inverter Non-automotive qualified products — Unless this data sheet expressly states that this specific Nexperia product is automotive qualified, the product is not suitable for automotive use. It is neither qualified nor tested in accordance with automotive testing or application requirements. Nexperia accepts no liability for inclusion and/or use of non-automotive qualified products in automotive equipment or applications. In the event that customer uses the product for design-in and use in automotive applications to automotive specifications and standards, customer (a) shall use the product without Nexperia's warranty of the product for such automotive applications, use and specifications, and (b) whenever customer uses the product for automotive applications beyond Nexperia's specifications such use shall be solely at customer’s own risk, and (c) customer fully indemnifies Nexperia for any liability, damages or failed product claims resulting from customer 74LV04AT Product data sheet design and use of the product for automotive applications beyond Nexperia's standard warranty and Nexperia's product specifications. Translations — A non-English (translated) version of a document is for reference only. The English version shall prevail in case of any discrepancy between the translated and English versions. 14.4 Trademarks Notice: All referenced brands, product names, service names and trademarks are the property of their respective owners. All information provided in this document is subject to legal disclaimers. Rev. 1 — 18 May 2017 © Nexperia B.V. 2017. All rights reserved. 11 / 12 74LV04AT Nexperia Hex inverter Contents 1 2 3 4 5 5.1 5.2 6 7 8 9 10 10.1 11 12 13 14 General description ............................................ 1 Features and benefits .........................................1 Ordering information .......................................... 1 Functional diagram ............................................. 2 Pinning information ............................................ 2 Pinning ............................................................... 2 Pin description ................................................... 2 Functional description ........................................3 Limiting values .................................................... 3 Recommended operating conditions ................ 3 Static characteristics .......................................... 4 Dynamic characteristics .....................................5 Waveforms and test circuit ................................ 6 Package outline ...................................................8 Abbreviations ...................................................... 9 Revision history .................................................. 9 Legal information .............................................. 10 Please be aware that important notices concerning this document and the product(s) described herein, have been included in section 'Legal information'. © Nexperia B.V. 2017. All rights reserved. For more information, please visit: http://www.nexperia.com For sales office addresses, please send an email to: salesaddresses@nexperia.com Date of release: 18 May 2017 Document identifier: 74LV04AT
74LV04ATPWJ 价格&库存

很抱歉,暂时无法提供与“74LV04ATPWJ”相匹配的价格&库存,您可以联系我们找货

免费人工找货