FDR25-0

FDR25-0

  • 厂商:

    HUMIREL(泰科)

  • 封装:

    -

  • 描述:

    CABLESTRANDEDMC

  • 数据手册
  • 价格&库存
FDR25-0 数据手册
SPECIFICATION: THIS ISSUE: Amendment 1, Issue 1 DATE: Raychem Wire and Cable 501 Oakside Avenue, Redwood City, CA 94063-3800 WCD 3304 9 October 2007 REPLACES: None PAGE: 1 of 2 SPECIFICATION FOR RADIATION-CROSSLINKED, HIGH FLEXIBILITY, FLUID RESISTANT POLYESTER BLEND JACKETED MULTICONDUCTOR CABLES This amendment forms a part of Raychem Specification WCD 3304, Issue 1, dated 31 May 1991. PAGE 6 Para 3.6.2.1 Configuration, delete and substitute the following: "3.6.2.1 Configuration The required number of components as specified in the applicable specification sheet shall be cabled together with a left-hand lay. For cables having multiple layers, the outer layer shall be left-hand and the inner layer or layers may be either right-hand or left-hand lay. The lay length of the components in the outer layer shall be not less than eight nor more than sixteen times the outside diameter of the cable bundle." PAGE 7 Para 3.6.8 Jacket Flaws, delete 2nd sentence and substitute the following: "Jacket flaws testing shall be performed during the final winding of the cable on shipment spools or reels using a voltage of 3.0 kV (rms) at a frequency of 50 Hz, 60 Hz, or 3 kHz. PAGE 17 Para 4.6.12.2 Voltage Withstand (Post-Environmental), delete and substitute the following: "4.6.12.2 Voltage Withstand (Post-Environmental) Voltage withstand (post-environmental) tests on the outer jacket shall be performed after the specified conditioning. The finished cable shall be immersed in a 5-percent, by weight, solution of sodium chloride in water at room temperature for at least one hour and, while the cable is still immersed, a voltage of 2.5 kV (rms) shall be applied for 1 minute between all the conductors and shields, tied together, and the water bath which shall be grounded." Para 4.6.13.1 "4.6.13.1 Procedure I, delete and substitute the following: Procedure I A length of cable, sufficient to produce a measured weight to at least 3 significant figures, shall be weighed and converted to the weight per unit length shown on the applicable specification sheet." © 2007 Tyco Electronics Corporation. All rights reserved. NOTE: ANY PRINTED COPY OF THIS DOCUMENT IS AN UNCONTROLLED COPY. Page 2 of 2 SPECIFICATION WCD 3304, AMENDMENT 1, ISSUE 1 PAGE 18 Para 5.1.3 Delete entirely. Add the following paragraph: "5.2 LABELING REQUIREMENTS All spools and reels shall be identified with the following information: Manufacturer's Part Number Lot Number Quantity in Feet (or Meters) Name of Manufacturer" © 2007 Tyco Electronics Corporation. All rights reserved. NOTE: ANY PRINTED COPY OF THIS DOCUMENT IS AN UNCONTROLLED COPY.
FDR25-0 价格&库存

很抱歉,暂时无法提供与“FDR25-0”相匹配的价格&库存,您可以联系我们找货

免费人工找货