G3VM-61H1
MOS FET Relays
MOS FET Relays Designed for Switching
Minute Signals and Analog Signals.
• Continuous load current of 400 mA.
RoHS compliant
Note: The actual product is marked differently from the
image shown here.
■ Application Examples
■ Terminal Arrangement/Internal Connections
6
• Semiconductor test equipment
5
4
• Test & Measurement equipment
OMRON logo
• Communication equipment
Model name
932
Pin 1 mark
• Data loggers
1
LOT.No.
3
2
Note: The actual product is marked differently from the image shown here.
■ List of Models
Package type
Contact form
SOP6
1a
(SPST-NO)
Load voltage
(peak value) *
Terminals
Surface-mounting Terminals
60 V
Model
Minimum package quantity
Number per tube Number per tape and reel
G3VM-61H1
G3VM-61H1 (TR)
75
-
-
2,500
* The AC peak and DC value are given for the load voltage.
■ Absolute Maximum Ratings (Ta = 25°C)
Output
Input
Item
LED forward current
Repetitive peak LED forward current
LED forward current reduction rate
LED reverse voltage
Connection temperature
Load voltage (AC peak/DC)
Connection A
Continuous
Connection B
load current
Connection C
Connection A
ON current
reduction
Connection B
rate
Connection C
Connection temperature
Dielectric strength between
I/O (See note 1.)
Ambient operating temperature
Ambient storage temperature
Soldering temperature
Symbol
IF
IFP
∆IF/°C
VR
TJ
VOFF
Rating
50
1
−0.5
5
125
60
400
400
800
−4.0
−4.0
−8.0
125
Unit
mA
A
mA/°C
V
°C
V
VI-O
1500
Vrms
Ta
Tstg
-
−40 to +85
−55 to +125
260
°C
°C
°C
IO
∆IO/°C
TJ
mA
mA/°C
Measurement conditions
100 µs pulses, 100 pps
Ta ≥ 25°C
Note: 1. The dielectric strength between the input and output was
checked by applying voltage between all pins as a group on
the LED side and all pins as a group on the light-receiving side.
Connection Diagram
Connection A
Connection A: AC peak/DC
Connection B and C: DC
Ta ≥ 25°C
Connection B
°C
AC for 1 min
With no icing or condensation
With no icing or condensation
10 s
Connection C
1
6
Load
2
5
3
4
or AC
DC
1
6
2
5
3
4
1
6
2
5
3
4
■ Electrical Characteristics (Ta = 25°C)
Output
Input
Item
Symbol Minimum Typical Maximum
LED forward voltage
VF
1.0
1.15
1.3
Reverse current
IR
10
Capacity between terminals
CT
30
Trigger LED forward current
IFT
1.6
3
Connection A
1
2
Maximum
resistance
Connection B
RON
0.5
1
with output ON Connection C
0.25
Current leakage when the relay is open
ILEAK
1.0
Capacity between terminals
Coff
130
Capacity between I/O terminals
CI-O
0.8
Insulation resistance between I/O terminals
RI-O
1000
Turn-ON time
tON
0.8
2.0
Turn-OFF time
tOFF
0.1
0.5
1
Unit
V
µA
pF
mA
Ω
Ω
Ω
µA
pF
pF
MΩ
ms
ms
Measurement conditions
IF = 10 mA
VR = 5 V
V = 0, f = 1 MHz
Note: 2. Turn-ON and Turn-OFF Times
IO = 400 mA
IF 1
6 RL
VDD
IF = 5 mA, IO = 400 mA
VOUT
2
4
IF = 5 mA, IO = 400 mA
IF = 5 mA, IO = 800 mA
VOFF = 60 V
V = 0, f = 1 MHz
IF
f = 1 MHz, VS = 0 V
VI-O = 500 VDC, ROH ≤ 60 %
90%
VOUT
10%
IF = 5 mA, RL = 200 Ω,
t ON
t OFF
VDD = 20 V (See note 2.)
Load
DC
Load
DC
G3VM-61H1
MOS FET Relays
■ Recommended Operating Conditions
Use the G3VM under the following conditions so that the Relay will operate properly.
Item
Symbol
Minimum
Typical
Maximum
Load voltage (AC peak/DC)
VDD
-
-
48
Unit
V
Operating LED forward current
IF
5
7.5
25
mA
Continuous load current (AC peak/DC)
IO
-
-
400
mA
Ambient operating temperature
Ta
−20
-
65
°C
■ Engineering Data
LED forward current vs. Ambient
temperature
Continuous load current vs. Ambient
temperature
80
60
40
1200
1000
Connection C
800
600
Connection A and B
20
20
40
60
80
100
0
20
40
80
100
0.6
120
On-state resistance vs. Ambient
temperature
IF = 5 mA
200
0
-200
IO = 400 mA
IF = 5 mA
4
Connection A
3
2
0.2
0.4
0
20
On-state voltage VON (V)
Turn ON, Turn OFF time vs. LED
forward current
Turn ON, Turn OFF time tON, tOFF (µs)
Ta = 25°C
VDD = 20 V
RL = 200 Ω
1000
500
300
tOFF
100
60
80
3
2
1
-20
0
tON
1000
300
tOFF
100
30
40
60
80
100
Ambient temperature Ta (°C)
Current leakage vs. Ambient
temperature
ILEAK - Ta
30
VOFF = 60 V
10
3
1
0.3
VDD = 20 V
IF = 5 mA
10
50
20
RL = 200 Ω
30
30
4
100
3000
tON
10
1.8
IO = 400 mA
t < 1s
Connection A
tON, tOFF - Ta
3000
5
5
Ambient temperature Ta (°C)
tON, tOFF - IF
50
40
Turn ON, Turn OFF time vs. Ambient
temperature
5000
1.6
0
-20
0.6
Current leakage ILEAK (nA)
0
1.4
IFT - Ta
5
0
-600
3
1.2
Trigger LED forward current vs.
Ambient temperature
1
-400
1
1
LED forward voltage VF (V)
Trigger LED forward current IFT (mA)
Ta = 25°C
-0.2
0.8
RON - Ta
On-state resistance RON (Ω)
Continuous load current IO (mA)
60
Ambient temperature Ta (°C)
Connection A
-0.4
3
0.1
-20
IO - VON
-0.6
10
0.3
120
600
400
30
200
Ambient temperature Ta (°C)
Continuous load current vs. On-state
voltage
Ta = 25°C
1
0
0
-20
100
400
0
Turn ON, Turn OFF time tON, tOFF (µs)
IF - VF
LED forward current IF (mA)
IO - Ta
100
Continuous load current IO (mA)
LED forward current IF (mA)
IF - Ta
LED forward current vs. LED forward
voltage
100
300
0.1
-20
0
LED forward current IF (mA)
20
40
60
80
100
Ambient temperature Ta (°C)
-20
0
20
40
60
80
100
Ambient temperature Ta (°C)
■ Safety Precautions
• Refer to "Common Precautions" for all G3VM models.
2
Appearance/Dimensions
SOP6 type
■ Appearance
SOP (Small Outline Package)
SOP6
OMRON logo
Model name
932
Pin 1 mark
LOT.No.
Note: The actual product is marked differently from the image shown here.
■ Dimensions
(Unit: mm)
Surface-mounting Terminals
Actual Mounting Pad
Dimensions
Weight: 0.13 g
4.4±0.25
(Recommended Value, TOP VIEW)
2.1 max.
6.3±0.25
6 to 6.3
1.2
0.15
0.8
2.54±0.25
0.1±0.1
0.4±0.1
Note: The actual product is marked differently from the image shown here.
0.6±0.3
7.0±0.4
2.54
2.54
• Application examples provided in this document are for reference only. In actual applications, confirm equipment functions and safety before using the product.
• Consult your OMRON representative before using the product under conditions which are not described in the manual or applying the product to nuclear control systems, railroad
systems, aviation systems, vehicles, combustion systems, medical equipment, amusement machines, safety equipment, and other systems or equipment that may have a serious
influence on lives and property if used improperly. Make sure that the ratings and performance characteristics of the product provide a margin of safety for the system or
equipment, and be sure to provide the system or equipment with double safety mechanisms.
Note: Do not use this document to operate the Unit.
OMRON Corporation
ELECTRONIC AND MECHANICAL COMPONENTS COMPANY
Contact: www.omron.com/ecb
Cat. No. K156-E1-01
0412(0412)(O)
很抱歉,暂时无法提供与“G3VM-61H1(TR)”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格
- 2500+14.34886
- 5000+13.39228
- 7500+13.04439
- 12500+12.71421
- 25000+12.40019
- 62500+12.10142
- 125000+11.81672