Data sheet
6EP1437-3BA10
SITOP PSU8200 24 V/40 A
SITOP PSU8200 24 V/40 A Stabilized power supply Input: 400-500 V
3 AC Output: 24 V DC/40 A !!! Phased-out product !!! Successor:
6EP3437-8SB00-0AY0
Input
Input
3-phase AC
Rated voltage value Vin rated
400 ... 500 V
Voltage range AC
320 ... 575 V
Wide-range input
Yes
Mains buffering
at Vin = 400 V
Mains buffering at Iout rated, min.
15 ms; at Vin = 400 V
Rated line frequency 1
50 Hz
Rated line frequency 2
60 Hz
Rated line range
47 ... 63 Hz
Input current
● at rated input voltage 400 V
2.6 A
● at rated input voltage 500 V
2.1 A
Switch-on current limiting (+25 °C), max.
56 A
I²t, max.
2.24 A²·s
Built-in incoming fuse
none
Protection in the mains power input (IEC 898)
Required: 3-pole connected miniature circuit breaker 10 ... 16 A
characteristic C or circuit breaker 3RV2011-1DA10 (setting 3 A) or
3RV2711-1DD10 (UL 489)
6EP1437-3BA10
Page 1/4
04/15/2020
Subject to change without notice
© Copyright Siemens
Output
Output
Controlled, isolated DC voltage
Rated voltage Vout DC
24 V
Total tolerance, static ±
3 %
Static mains compensation, approx.
0.1 %
Static load balancing, approx.
0.2 %
Residual ripple peak-peak, max.
100 mV
Spikes peak-peak, max. (bandwidth: 20 MHz)
200 mV
Adjustment range
24 ... 28.8 V
Product function Output voltage adjustable
Yes
Output voltage setting
via potentiometer; max. 960 W
Status display
Green LED for 24 V OK
Signaling
Relay contact (NO contact, rating 60 V DC/ 0.3 A) for "24 V OK"
On/off behavior
No overshoot of Vout (soft start)
Startup delay, max.
2.5 s
Voltage increase time of the output voltage maximum
500 ms
Rated current value Iout rated
40 A
Current range
0 ... 40 A
● Note
Supplied active power typical
+60 ... +70 °C: Derating 3.75%/K
960 W
Short-term overload current
● at short-circuit during operation typical
120 A
Duration of overloading capability for excess current
● at short-circuit during operation
25 ms
Constant overload current
● on short-circuiting during the start-up typical
44 A
Parallel switching for enhanced performance
Yes; switchable characteristic
Numbers of parallel switchable units for enhanced
performance
2
Efficiency
Efficiency at Vout rated, Iout rated, approx.
92 %
Power loss at Vout rated, Iout rated, approx.
83 W
Closed-loop control
Dynamic mains compensation (Vin rated ±15 %),
max.
1 %
Dynamic load smoothing (Iout: 50/100/50 %), Uout ±
typ.
3 %
Setting time maximum
10 ms
Protection and monitoring
Output overvoltage protection
< 35 V
Current limitation, typ.
44 A
Property of the output Short-circuit proof
Yes
6EP1437-3BA10
Page 2/4
04/15/2020
Subject to change without notice
© Copyright Siemens
Short-circuit protection
Alternatively, constant current characteristic approx. 44 A or
latching shutdown
Enduring short circuit current RMS value
● typical
44 A
Overcurrent overload capability in normal operation
overload capability 150 % Iout rated up to 5 s/min
Overload/short-circuit indicator
LED yellow for "overload", LED red for "latching shutdown"
Safety
Primary/secondary isolation
Yes
Galvanic isolation
Safety extra-low output voltage Uout acc. to EN 60950-1 and EN
50178
Protection class
Class I
Leakage current
● maximum
Degree of protection (EN 60529)
3.5 mA
IP20
Approvals
CE mark
Yes
UL/cUL (CSA) approval
cULus-Listed (UL 508, CSA C22.2 No. 107.1), File E197259,
cCSAus (CSA C22.2 No. 60950-1, UL 60950-1)
Explosion protection
IECEx Ex nA nC IIC T4 Gc; ATEX (EX) II 3G Ex nA nC IIC T4 Gc;
cCSAus (CSA C22.2 No. 213, ANSI/ISA-12.12.01) Class I, Div. 2,
Group ABCD, T4
FM approval
-
CB approval
Yes
Marine approval
ABS, DNV GL
EMC
Emitted interference
EN 55022 Class B
Supply harmonics limitation
EN 61000-3-2
Noise immunity
EN 61000-6-2
environmental conditions
Ambient temperature
● during operation
— Note
-25 ... +70 °C
With natural convection; startup tested starting from -40 °C
nominal voltage
● during transport
-40 ... +85 °C
● during storage
-40 ... +85 °C
Humidity class according to EN 60721
Climate class 3K3, 5 … 95% no condensation
Mechanics
Connection technology
screw-type terminals
Connections
● Supply input
L1, L2, L3, PE: 1 screw terminal each for 0.2 ... 4 mm² singlecore/finely stranded
● Output
+, -: 2 screw terminals each for 0.33 ... 10 mm²
6EP1437-3BA10
Page 3/4
04/15/2020
Subject to change without notice
© Copyright Siemens
● Auxiliary
13, 14 (alarm signal): 1 screw terminal each for 0.14 ... 1.5 mm²
Width of the enclosure
150 mm
Height of the enclosure
125 mm
Depth of the enclosure
150 mm
Required spacing
● top
50 mm
● bottom
50 mm
● left
0 mm
● right
0 mm
Weight, approx.
3.4 kg
Product feature of the enclosure housing for side-byside mounting
Yes
Installation
Snaps onto DIN rail EN 60715 35x15
Electrical accessories
Buffer module
Mechanical accessories
Device identification label 20 mm × 7 mm, TI-grey 3RT29001SB20
MTBF at 40 °C
885 739 h
Other information
Specifications at rated input voltage and ambient temperature +25
°C (unless otherwise specified)
6EP1437-3BA10
Page 4/4
04/15/2020
Subject to change without notice
© Copyright Siemens
很抱歉,暂时无法提供与“6EP1437-3BA10”相匹配的价格&库存,您可以联系我们找货
免费人工找货