USOP, Small and High-load-voltage Type
High-load-voltage
USOP Package with
High Load voltage
• Load voltage: 60 V, 75 V, 80 V, or 100 V
• G3VM-61PR1: Low C × R = 7 pF·Ω, COFF (standard) = 0.7 pF,
RoHS Compliant
Note: The actual product is marked differently from the
image shown here.
■Application Examples
• Semiconductor test equipment
• Communication equipment
• Test & measurement equipment
• Data loggers
(Unit : mm, Average)
USOP 4-pin
■Model Number Legend
1 2 3 4 5
103
1.65
Note: The actual product is marked differently
from the image shown here.
1. Load Voltage
6: 60 V
7: 75 V
8: 80 V
10: 100 V
2. Contact form
1: 1a (SPST-NO)
3. Package
P: USOP 4-pin
4. Additional functions
R: Low On-resistance
5. Other informations
When specifications overlap,
serial code is added in the
recorded order.
Package
Contact form
Terminals
Load voltage
(peak value) *
USOP4
1a
(SPST-NO)
Surface-mounting
Terminals
75 V
120 mA
400 mA
Tape cut packaging
Model
Minimum
package
quantity
G3VM-61PR1
Model
Minimum
package
quantity
G3VM-61PR1(TR05)
G3VM-61PR
G3VM-71PR
Tape packaging
G3VM-61PR(TR05)
1 pc.
G3VM-71PR(TR05)
120 mA
G3VM-81PR
G3VM-81PR(TR05)
100 V
100 mA
G3VM-101PR
G3VM-101PR(TR05)
500 pcs.
Certified Models with
Standards Certification
80 V
Small and Highload-voltage
60 V
Continuous
load current
(peak value) *
Low-output-capacitance
and Low-ON-resistance
■Ordering Information
Current-limiting
3.25
2.2
High-dielectricstrength
G3V M- @ @ @ @ @
2PA
Small and HighMulti-contact-pair High-current and
(2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength
RON (standard) = 10 Ω
■Package
General-purpose
MOS FET Relays
Introduction
G3VM-61PR@/71PR/81PR/101PR
Note: To order tape packaging for Relays with surface-mounting terminals, add "(TR05)" to the end of the model number.
Tape-cut USOPs are packaged without humidity resistance. Use manual soldering to mount them.
Refer to common precautions.
* The AC peak and DC value are given for the load voltage and continuous load current.
DIP
SOP
SSOP
USOP
VSON
G3VM-61PR@/71PR/81PR/101PR
181
Item
Symbol G3VM-61PR1 G3VM-61PR G3VM-71PR G3VM-81PR G3VM-101PR
High-load-voltage
Input
LED forward current
LED forward current reduction rate
Unit
IF
50
mA
ΔIF/°C
−0.5
mA/°C
LED reverse voltage
VR
5
V
Connection temperature
TJ
125
°C
Load voltage (AC peak/DC)
Output
General-purpose
Multi-contact-pair High-current and
Small and High(2a, 2b, and 1a1b) Low-ON-resistance dielectric-strength
VOFF
Continuous load current (AC peak/DC)
60
IO
120
75
400
ΔIO/°C
−1.2
−4
Pulse ON current
lop
360
1,200
Connection temperature
TJ
ON current reduction rate
80
100
V
120
100
mA
−1.2
−1
mA/°C
360
300
mA
125
°C
Dielectric strength between I/O (See note 1.)
VI-O
500
Vrms
Ambient operating temperature
Ta
−40 to +85
°C
Tstg
−40 to +125
°C
−
260
°C
Ambient storage temperature
Soldering temperature
Measurement conditions
Ta≥25°C
Ta≥25°C
t=100 ms, Duty=1/10
AC for 1 min
With no icing or condensation
10 s
Note: 1. The dielectric strength between the input and output was checked by applying voltage between all pins as a group on the LED side and all pins as a group on
the light-receiving side.
■Electrical Characteristics (Ta = 25°C)
Item
Current-limiting
Output
High-dielectricstrength
Low-output-capacitance
and Low-ON-resistance
Small and Highload-voltage
Symbol
G3VM-61PR1 G3VM-61PR G3VM-71PR G3VM-81PR G3VM-101PR Unit
Minimum
1.0
LED forward voltage
VF
Typical
1.15
Maximum
1.3
Reverse current
IR
Maximum
10
Capacitance between terminals
CT
Typical
Trigger LED forward current
IFT
Release LED forward current
IFC
Maximum resistance with output ON
RON
Current leakage when the relay is open
ILEAK
Capacitance between terminals
COFF
Capacitance between I/O terminals
CI-O
Insulation resistance between I/O terminals
RI-O
Turn-ON time
tON
Turn-OFF time
tOFF
Typical
15
1.0
0.5
Maximum
0.5
3
Minimum
0.1
Typical
10
Maximum
0.6
0.2
0.1
1
15
7
1.5
Maximum
1
12
14
0.2
Typical
0.7
20
30
5
6
Maximum
1.3
30
−
7
8
Typical
0.4
0.3
1000
Typical
108
Typical
0.4
IF=10 mA
VR=5 V
pF
V=0, f=1 MHz
mA
IO=100 mA
mA
IOFF=10 μA
0.4
Maximum
V
μA
8
0.02
0.04
0.3
0.14
Maximum
0.2
0.5
2
0.5
0.3
Typical
0.12
0.3
0.2
0.16
0.18
Maximum
0.2
0.5
1
0.2
0.3
Measurement conditions
Ω
G3VM-61PR : IF=5 mA,
Io=400 mA
Others : IF=5 mA,
Io=Continuous load current
ratings, t
很抱歉,暂时无法提供与“G3VM71PRTR05”相匹配的价格&库存,您可以联系我们找货