0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
6ES75225FF000AB0

6ES75225FF000AB0

  • 厂商:

    SIEMENS

  • 封装:

  • 描述:

    DQ 8X230VAC/2A ST (TRIAC)

  • 数据手册
  • 价格&库存
6ES75225FF000AB0 数据手册
Data sheet 6ES7522-5FF00-0AB0 SIMATIC S7-1500, digital output module DQ 8x230 V AC/2 A ST; TRIAC; 8 channels in groups of 1; 2 A per group; Substitute value: Front connector (screw terminals or push-in) to be ordered separately General information Product type designation DQ 8x230 V AC/2A ST (triac) HW functional status FS01 Firmware version ● FW update possible Yes Product function ● I&M data Yes; I&M0 to I&M3 ● Isochronous mode No ● Prioritized startup Yes Engineering with ● STEP 7 TIA Portal configurable/integrated from version V12 / V12 ● STEP 7 configurable/integrated from version V5.5 SP3 / - ● PROFIBUS from GSD version/GSD revision V1.0 / V5.1 ● PROFINET from GSD version/GSD revision V2.3 / - Operating mode ● DQ Yes ● DQ with energy-saving function No ● PWM No ● Oversampling No ● MSO Yes Output voltage Rated value (AC) 230 V; 120/230 V AC, 50/60 Hz Power Power available from the backplane bus 0.9 W Power loss Power loss, typ. 10.8 W Digital outputs Type of digital output Triac Number of digital outputs 8 Current-sourcing Yes Digital outputs, parameterizable Yes Short-circuit protection No ● built-in fuse 6.3 A melting fuse, slow-blow Switching capacity of the outputs ● with resistive load, max. 6ES75225FF000AB0 Page 1/2 2A 1.20.2021 Subject to change without notice © Copyright Siemens ● on lamp load, max. 50 W Output voltage ● for signal "1", min. L1 (-1.5 V) at maximum output current; L1 (-8.5 V) at minimum output current Output current ● for signal "1" rated value 2A ● for signal "1" permissible range, min. 10 mA ● for signal "1" permissible range, max. 15 A; max. 1 AC cycle ● for signal "0" residual current, max. 2 mA Output delay with resistive load ● "0" to "1", max. 1 AC cycle ● "1" to "0", max. 1 AC cycle Parallel switching of two outputs ● for logic links No ● for uprating No ● for redundant control of a load Yes Switching frequency ● with resistive load, max. 10 Hz ● with inductive load, max. 0.5 Hz ● on lamp load, max. 1 Hz Total current of the outputs ● Current per channel, max. 2 A; see additional description in the manual ● Current per group, max. 2 A; see additional description in the manual ● Current per module, max. 10 A; see additional description in the manual Cable length ● shielded, max. 1 000 m ● unshielded, max. 600 m Interrupts/diagnostics/status information Diagnostics function No Substitute values connectable Yes Alarms ● Diagnostic alarm No ● Maintenance interrupt No Diagnoses ● Monitoring the supply voltage No ● Wire-break No ● Short-circuit No Diagnostics indication LED ● RUN LED Yes; green LED ● ERROR LED Yes; red LED ● Monitoring of the supply voltage (PWR-LED) No ● Channel status display Yes; green LED ● for channel diagnostics No ● for module diagnostics Yes; red LED Potential separation Potential separation channels ● between the channels Yes ● between the channels, in groups of 1 ● between the channels and backplane bus Yes ● Between the channels and load voltage L1 Yes Permissible potential difference between different circuits 250 V AC between the channels and the backplane bus; 500 V AC between the channels Isolation Isolation tested with 3 100 V DC Standards, approvals, certificates Suitable for safety functions No Ambient conditions 6ES75225FF000AB0 Page 2/3 1.20.2021 Subject to change without notice © Copyright Siemens Ambient temperature during operation ● horizontal installation, min. 0 °C ● horizontal installation, max. 60 °C ● vertical installation, min. 0 °C ● vertical installation, max. 40 °C Dimensions Width 35 mm Height 147 mm Depth 129 mm Weights Weight, approx. 290 g last modified: 1/16/2021 6ES75225FF000AB0 Page 3/3 1.20.2021 Subject to change without notice © Copyright Siemens
6ES75225FF000AB0 价格&库存

很抱歉,暂时无法提供与“6ES75225FF000AB0”相匹配的价格&库存,您可以联系我们找货

免费人工找货